6 resultados para Aneroid sphygmomanometer
em Scielo Saúde Pública - SP
Resumo:
PURPOSE: To find out the prevalence of hypertension in employees of the Hospital and relate it to social demographic variables. METHODS: Blood pressure measurement was performed with a mercury sphygmomanometer, using an appropriate cuff size for arm circumference, weight, and height in a population sample of 864 individuals out of the 9,905 employees of a University General Hospital stratified by gender, age, and job position. RESULTS: Hypertension prevalence was 26% (62% of these reported being aware of their hypertension and 38% were unaware but had systolic/diastolic blood pressures of >140 and/or >90 mm Hg at the moment of the measurement). Of those who were aware of having hypertension, 51% were found to be hypertensive at the moment of the measurement. The prevalence was found to be 17%, 23%, and 29% (P <.05) in physicians, nursing staff, and "others", respectively. The univariate analysis showed a significant odds ratio for the male gender, age >50 years, work unit being the Institute of Radiology and the Administration Building, educational level
Resumo:
OBJECTIVE: To evaluate the sphygmomanometers calibration accuracy and the physical conditions of the cuff-bladder, bulb, pump, and valve. METHODS: Sixty hundred and forty five aneroid sphygmomanometers were evaluated, 521 used in private practice and 124 used in hospitals. Aneroid manometers were tested against a properly calibrated mercury manometer and were considered calibrated when the error was <=3mm Hg. The physical conditions of the cuffs-bladder, bulb, pump, and valve were also evaluated. RESULTS: Of the aneroid sphygmomanometers tested, 51% of those used in private practice and 56% of those used in hospitals were found to be not accurately calibrated. Of these, the magnitude of inaccuracy ranged from 4 to 8mm Hg in 70% and 51% of the devices, respectively. The problems found in the cuffs - bladders, bulbs, pumps, and valves of the private practice and hospital devices were bladder damage (34% vs. 21%, respectively), holes/leaks in the bulbs (22% vs. 4%, respectively), and rubber aging (15% vs. 12%, respectively). Of the devices tested, 72% revealed at least one problem interfering with blood pressure measurement accuracy. CONCLUSION: Most of the manometers evaluated, whether used in private practice or in hospitals, were found to be inaccurate and unreliable, and their use may jeopardize the diagnosis and treatment of arterial hypertension.
Resumo:
OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.
Resumo:
Background:Systemic hypertension is highly prevalent and an important risk factor for cardiovascular events. Blood pressure control in hypertensive patients enrolled in the Hiperdia Program, a program of the Single Health System for the follow-up and monitoring of hypertensive patients, is still far below the desired level.Objective:To describe the epidemiological profile and to assess blood pressure control of patients enrolled in Hiperdia, in the city of Novo Hamburgo (State of Rio Grande do Sul, Brazil).Methods:Cross-sectional study with a stratified cluster random sample, including 383 adults enrolled in the Hiperdia Program of the 15 Basic Health Units of the city of Porto Alegre, conducted between 2010 and 2011. Controlled blood pressure was defined as ≤140 mmHg × 90 mmHg. The hypertensive patients were interviewed and their blood pressure was measured using a calibrated aneroid device. Prevalence ratios (PR) with 95% confidence interval, Wald's χ2 test, and simple and multiple Poisson regression were used in the statistical analysis.Results:The mean age was 63 ± 10 years, and most of the patients were females belonging to social class C, with a low level of education, a sedentary lifestyle, and family history positive for systemic hypertension. Diabetes mellitus (DM) was observed in 31%; adherence to the antihypertensive treatment in 54.3%; and 33.7% had their blood pressure controlled. DM was strongly associated with inadequate BP control, with only 15.7% of the diabetics showing BP considered as controlled.Conclusion:Even for hypertensive patients enrolled in the Hiperdia Program, BP control is not satisfactorily reached or sustained. Diabetic hypertensive patients show the most inappropriate BP control.
Resumo:
The reasons for the inconsistent association between salt consumption and blood pressure levels observed in within-society surveys are not known. A total of 157 normotensive subjects aged 18 to 35 years, selected at random in a cross-sectional population-based survey, answered a structured questionnaire. They were classified as strongly predisposed to hypertension when two or more first-degree relatives had a diagnosis of hypertension. Anthropometric parameters were obtained and sitting blood pressure was determined with aneroid sphygmomanometers. Sodium and potassium excretion was measured by flame spectrophotometry in an overnight urine sample. A positive correlation between blood pressure and urinary sodium excretion was detected only in the group of individuals strongly predisposed to hypertension, both for systolic blood pressure (r = 0.51, P<0.01) and diastolic blood pressure (r = 0.50, P<0.01). In a covariance analysis, after controlling for age, skin color and body mass index, individuals strongly predisposed to hypertension who excreted amounts of sodium above the median of the entire sample had higher systolic and diastolic blood pressure than subjects classified into the remaining conditions. The influence of familial predisposition to hypertension on the association between salt intake and blood pressure may be an additional explanation for the weak association between urinary sodium excretion and blood pressure observed in within-population studies, since it can influence the association between salt consumption and blood pressure in some but not all inhabitants.
Resumo:
The progressive behavior of the blood pressure of term newborns during the first week of life was assessed by the simultaneous use of oscillometric and Doppler methods. A total of 174 term neonates born at the Municipal Hospital Odilon Behrens in Belo Horizonte, from March 1996 to February 1997, were prospectively assessed. The oscillometric and Doppler ultrasonic methods were simultaneously used for four consecutive recordings obtained at 12 ± 6, 24 ± 6 and 72 ± 24 h and on the 7th ± 1 day of life. The combined use of the two methods simplified the procedure, with automatic cuff inflation and deflation, and speed was properly controlled with an automatic pressure monitor. The procedure was performed using a Y-connection to the mercury sphygmomanometer, with blood pressure being recorded with an automatic device and systolic blood pressure being measured simultaneously by Doppler ultrasound. The newborns were awake, not crying and in the supine position. A statistically significant increase in systolic and diastolic blood pressure was observed between the first and second, and the third and fourth measurements by Doppler and oscillometric methods. No significant correlation between birth weight, length, ponderal index and blood pressure was observed. The technique used represents a simpler and more accurate procedure for blood pressure measurement.