50 resultados para Analytes
em Scielo Saúde Pública - SP
Resumo:
The objectives of this study were to evaluate the residues of the insecticide carbosulfan and its carbofuran metabolites and 3-hydroxy-carbofuran in orange compartments (whole fruit, bagasse and juice) and comparison between the residual levels found in fruits with the maximum residue level and the safety interval established by the Brazilian legislation. Two field experiments were carried out, both with the following treatments: a-check; b-one application of 10 g of carbosulfan . 100 L-1 of water; c-one application with twice the rate applied in treatment b; d-four applications with the same rate applied in treatment b. Samples were taken at (-1), zero, 1, 3, 7, 14, 21 and 28 days after the last or unique application. The quantitative determinations were done by gas chromatography technique, using a nitrogen-phosphorus detector. The carbosulfan metabolism to its carbofuran metabolite was rapid (3 days), being both analytes concentrated in the bagasse (peel + flavedo + albedo). However, the metabolism of carbofuran to 3-hydroxy-carbofuran was of low intensity or this metabolite was quickly dissipated. Carbosulfan residues and its metabolites did not penetrate into the fruit, thus not contaminating the juice. The use of the pesticide was adequate, with respect to fruit consumption, in relation to the Brazilian legislation.
Resumo:
The ability of enzymes to function in aquo-restricted media (commonly reported as non-aqueous media) has greatly enlarged the applications in numerous fields. The development of biosensors was also benefited with this area, expanding their applications toward many previously inaccessible analytes, enlarging significantly the scope of applications. In this review, some basic factors that influence biocatalytical reactions in aquo-restricted media is discussed. Attention is focused on the development, advantages and analytical applications of biosensors in non-aqueous media. Recent examples and relevant applications of their use are presented.
Resumo:
In this work the contamination, by organochlorinated, of a drinking water source located in the region of Viçosa, MG, was evaluated. The identification and quantification of the analytes was carried out using a gas-chromatograph equipped with an electron capture detector after liquid-liquid extraction and concentration. Four insecticides, Aldrin, Epoxy heptachloride, Endrin and op'- DDT were detected in concentrations that are higher than the safety limits established in the Brazilian legislation.
Resumo:
The sequential extraction procedure proposed by Tessier and total digestion were applied for the analysis of sediment samples from Tubarão River. The recoveries were between 93.5 and 102.5% for Cu and 99.2 and 111% for Pb. The precision was tipically better than 6% for Cu and 3% for Pb. Comparison of the values obtained for the total digest with the sum of the extracted fractions showed that there were no significant losses in the extraction steps so that the method can be used for the monitoring availability and mobility of these analytes. According to ten points of sampling, was possible to determined the average of labiles phases (fractions 1 and 4) for Pb and Cu: 33.70% and 18.18%, respectively; and the inert phases (fraction 5- residual): 66.30% for Pb and 81.82% for Cu.
Resumo:
This article describes the current status of several analytical methodologies using vegetal tissue and crude extracts as enzymatic source. In this divulgation paper the obtention of vegetal crude extract and/or tissue and selected enzymatic procedures are presented emphasizing its characteristics and peculiarities. Examples of many biosensors and/or flow injection procedures using vegetal tissues or crude extracts for the determination of many analytes, such as amines, ascorbic acid, ethanol, glutamate, hydrogen peroxide, oxalic acid, pectins, phenolic compounds and urea of biologic, environmental, food, pharmaceutical and industrial interests are also given and discussed.
Resumo:
This paper is a translation from IUPAC nomenclature document by K. Danzer and L. A. Currie (Pure Appl. Chem., 1998, 70(4), 993-1014). Its goal is to establish an uniform and meaningful approach to terminology (in Portuguese), notation, and formulation for calibation in analytical chemistry. In this first part, general fundamentals of calibration are presented, namely for both relationships of qualitative and quantitative variables (relations between variables characterizing certain types analytes of the measured function on the other hand and between variables characterizing the amount or concentration of the chemical species and the intensities of the measured signals, on the other hand). On this basis, the fundamentals of the common single component calibration (Univariate Calibration) which models the relationship y = f(x) between the signal intensities y and the amounts or concentrations x of the analyte under given conditions are represented. Additional papers will be prepared dealing with extensive relationships between several intensities and analyte contents, namely with multivariate calibrations and with optimization and experimental design.
Resumo:
This paper describes the development of a methodology for solid phase extraction (SPE) and pre-concentration of nitrosamines from aqueous samples using granular activated charcoal as stationary phase. micelar electrokinetic capillary Chromatography (MEKC) was used for the separation and identification of the nitrosamines in the extracts. Using a sample with 50 µg l-1 of each nitrosamines standards (dimethylnitrosamine, DMN; diethylnitrosamine, DEN; N-nitrosopyrrolidine, NPYR; N-nitrosopiperidine, NPIP; N-nitrosomorpholine, NMOR), the methodology showed a range of recuperation from 29 to 107% with a linear zone between 10 and 500 µg l-1. The developed methodology can be applicable to the determination of these analytes in different aqueous samples.
Resumo:
This paper presents a new way for the construction of silver electrodes utilizing recordable CDs. The new electrodes were explored for the quantification of chloride (by potentiometry/FIA), cyanide (by amperometry/FIA) and for lead analysis (by square wave voltammetry). For the flowing measurements, a digital multimeter, connected to a microcomputer (via RS 232 interface) was used to collect directly the potential signal (for Cl- measurements) or to take the output signal from a potentiostat (for CN- measurements). The square wave voltammetry analysis was performed in a commercial instrument. The results shown good performance of the new electrodes and the detection limit (s/n = 3) attained for these three analytes were: 0.2, 50, and 200 µg L-1 for Pb2+, Cl-, and CN- respectively.
Resumo:
The basic principles of UV irradiation as sample pre-treatment step and its potential for inorganic analysis are illustrated and discussed through significant examples from the literature. Not only does this overview cover the classical applications of this technique in the decomposition of organic matter in electroanalysis, but it also presents recent trends, including the increasing interest in employing UV irradiation in flow analytical systems, successful attempts to enhance its effectiveness and the coupling with chromatographic and spectroscopic methodologies. Furthermore, a number of relevant cases of UV-driven derivatization reactions involving photo-sensitive inorganic species are presented, showing some convenient options to perform fast and reliable determination of inorganic and organic analytes.
Resumo:
The atomization behavior of Au, Ag, Bi, Cd, Pb, and Sn from pyrolitic graphite coating (L'vov platform) with the use Pd and Mg solutions, and zirconium coated platform with the analytes in nitric acid 0.2% v/v and in ethanol was investigated. In ethanol medium, the sensitivity gain was three-fold for Bi and Cd using Zr as modifier. Without modifier, the ethanol medium is appropriate only for Au and Cd. In nitric acid medium, the Zr coated platform elevates sensitivity at least two-fold for Bi and Cd. The method was applied to the determination of Ag, Au and Bi of certified steel samples, after on-line preconcentration, sorption on a minicolumn filled with C-18 bonded to silica gel and elution with ethanol. The concentrations obtained agreed with the recommended values.
Resumo:
The development of liquid chromatography-mass spectrometric (LC-MS) techniques in the last few decades has made possible the analysis of trace amounts of analytes from complex matrices. With LC, the analytes of interest can be separated from each other as well as from the interfering matrix, after which they can be reliably identified thanks to the sensitivity and specificity of MS. LC-MS has become an irreplaceable tool for many applications, ranging from the analysis of proteins or pharmaceuticals in biological fluids to the analysis of toxic substances in environmental samples. In different segments of Brazilian Industry mass spectrometry has an important role, e.g. in the pharmaceutical industry in the development of generic formulations, contributing to the growth of Industry and social inclusion. However, the Brazilian chemists until this moment don't have an effective role in this new segment of the analytical chemistry in Brazil. The present paper shows the actual scenario for mass spectrometry in the pharmaceutical industry, emphasizing the need of a revision of graduation courses to attend the needs of this growing market.
Resumo:
A series of bovine serum albumin-immobilized supports have been prepared and used as restricted access media (RAM) columns. Restricted-access supports combine size-exclusion of proteins and other high-molar-mass matrix components with the simultaneous enrichment of low-molar mass analytes. These characteristics were chromatographically evaluated for the columns. The RAM-BSA (Bovine Serum Albumin) columns showed excellent performance for exclusion of human plasma protein with good retention capacity for a series of acidic, basic, and neutral drugs.
Resumo:
A solid phase extraction procedure using Amberlite XAD-1180/Pyrocatechol violet (PV) chelating resin for the determination of iron and lead ions in various environmental samples was established. The procedure is based on the sorption of lead(II) and iron(III) ions onto the resin at pH 9, followed by elution with 1 mol/L HNO3 and determination by flame atomic absorption spectrometry. The influence of alkaline, earth alkaline and some transition metals, as interferents, are discussed. The recoveries for the spiked analytes were greater than 95%. The detection limits for lead and iron by FAAS were 0.37 µg/L and 0.20 µg/L, respectively. Validation of the method described here was performed by using three certified reference materials (SRM 1515 Apple Leaves, SRM 2711 Montana Soil and NRCC-SLRS-4 Riverine Water). The procedure was successfully applied to natural waters and human hair.
Resumo:
Inductively Coupled Plasma Optical Emission Spectrometry was used to determine Ca, Mg, Mn, Fe, Zn and Cu in samples of processed and natural coconut water. The sample preparation consisted in a filtration step followed by a dilution. The analysis was made employing optimized instrumental parameters and the results were evaluated using methods of Pattern Recognition. The data showed common concentration values for the analytes present in processed and natural samples. Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) indicated that the samples of different kinds were statistically different when the concentrations of all the analytes were considered simultaneously.
Resumo:
The development of an array of chemically-responsive dyes on a porous membrane and in its use as a general sensor for odors and volatile organic compounds (VOCs) is reviewed. These colorimetric sensor arrays (CSA) act as an "optoelectronic nose" by using an array of multiple dyes whose color changes are based on the full range of intermolecular interactions. The CSA is digitally imaged before and after exposure and the resulting difference map provides a digital fingerprint for any VOC or mixture of odorants. The result is an enormous increase in discriminatory power among odorants compared to prior electronic nose technologies. For the detection of biologically important analytes, including amines, carboxylic acids, and thiols, high sensitivities (ppbv) have been demonstrated. The array is essentially non-responsive to changes in humidity due to the hydrophobicity of the dyes and membrane.