145 resultados para Ames assay
em Scielo Saúde Pública - SP
Resumo:
The mutagenic activities of 16 anti-parasite drugs were screened by the Simultest in both qualitative (spot test) and quantitative (plate incorporation) assays with a Salmonella typhimurium pool composed by the indicator strains TA97, TA 98, TA100 and TA102. Four anti Chagas' disease drugs (nifurtimox, benznidazole, CL 64,855, and MK 436) and two anti-amebae drugs (metronidazole and tinidazole) gave positive results in qualitative tests and incorporation of rat liver microsomes did not alter the results. Comparative dose response curves of the mutagenic activities of CL 64,855, metronidazole and benznidazole obtained by the simultest and by individual Salmonella indicator strains demonstrated that both approachs have similar sensitivities. The results corroborate the validity of the Simultest, as a simplified, fast and economic version of the Ames test in preliminary screening of potential mutagenic drugs.
Resumo:
The nitroimidazole-tiadiazole derivative CL 64,855 (2-amino-5-(1-methyl-5-nitro-2-imidazolyl)-1,3,4-thiadiazole, a potent anti-trypanosomal drug, was assayed in a short-term bacterial mutagenicity test with Salmonella typhimurium strains TA 98, TA 100 and TA 102. Results indicate that CL 64,855 is a potent frameshift mutagen detected by strains TA 98 and TA 102. CL 64,855 was able to revert the indicators strains at concentrations as low as 0.1 µg/plate. Metabolic activation experiments with rat liver microsomal fractions did not increase the mutagenic action of Cl 64,855.
Resumo:
The Authors describe an anti-Leishmania IgA-ELISA assay in mucocutaneous leishmaniasis. Increased titers were found in leishmaniasis patients, mainly in the first and second year of infection and in deep mycoses patients showing either mucosal involvement or widespread disease.
Resumo:
An Immunoperoxidase technique for identification of leptospires in formalin fixed, paraffin embedded kidney sections is presented, using peroxidase-antiperoxidase complex. The anti-leptospiral antibody was raised in rabbit. Possible applications of this technique are discussed.
Resumo:
In order to define an accurate assay for anti-adenovirus antibody detection, a recently developed ELISA was compared with IFA and CF. On 58 sera, the ELISA was more sensitive than both CF and IFA, which showed relative sensitivities of 63% and 94%, respectively. It was not possible to determine the exact specificity of the tests because of the lack of a gold standard. Furthermore, the ELISA was used to define the prevalence of adenovirus antibodies in 116 infants between 1 and 24 months old (mean 7.28). The data showed that maternal antibodies waned by the age of 5 to 6 months and that more than 80% of the children had been infected by adenoviruses by the age of 10 months.
Resumo:
An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.
Resumo:
Diagnostic performance indexes of sensitivity, specificity, positive predictive value and efficiency were determined for dot-ELISA and IgG-ELISA tests in 340 leishmaniasis sera. Sensitivity of the dot-ELISA was significantly lower than IgG-ELISA's; the two tests had indexes of specificity and positive predictive value of the same magnitude. Seventy-eight sera gave a negative dot-ELISA test result and a positive IgG-ELISA test result. When sera were classified according to different criteria as how to interpret this diversity, the kappa statistic did not corroborate the classification indicating that the two tests display a substantial strength of agreement. The results presented indicate that performance indexes accrued in a survey where variables arc well known may be extrapolated to other population studies if the disease presents itself as highly prevalent (due to a selection bias or not) and may be expected to discriminate a disease status among test positives.
Resumo:
We have evaluated the sensitivity of the classical blood subinoculation method, modified through cyclophosphamide treatment of transferred mice, for the detection of occult parasitaemias in Trypanosoma cruzi chronically infected mice. Besides its simplicity, the method was shown to be highly sensitive for both the "chronic" phase parasites (99% of chronic cases were shown to harbour occult parasitaemias) and for the acute phase parasites (T. cruzi could be detected in 53.8% of animals transferred with one Y strain parasite and in 20% of animals transferred with one CL strain parasite). Using acute phase bloodforms, the assay proved to be more sensitive than conventional subinoculation when dealing with the CL, but not the Y strain of the parasite. With the help of this parasite detection tool, we have studied during a one year period, the evolution of subpatent parasitaemias in a group of mice which survived through chemotherapy from lethal acute phase of T. cruzi infection. Cyclophosphamide transfer assay revealed occult parasitaemias in 100% of the chronic animals, nevertheless, continuous and discontinuous patterns of positivity were observed.
Resumo:
The dot-enzyme-linked immunosorbent assay (dot-ELISA) was standardized using somatic (S) and excretory-secretory (ES) antigens of Toxocara-canis for the detection of specific antibodies in 22 serum samples from children aged 1 to 15 years, with clinical signs of toxocariasis. Fourteen serum samples from apparently normal individuals and 28 sera from patients with other pathologies were used as controls. All samples were used before and after absorption with Ascaris suum extract. When the results were evaluated in comparison with ELISA, the two tests were found to have similar sensitivity, but dot-ELISA was found to be more specific in the presence of the two antigens studied. Dot-ELISA proved to be effective for the diagnosis of human toxocariasis, presenting advantages in terms of yield, stability, time and ease of execution and low cost.
Resumo:
An Enzyme-linked immunosorbent assay ELISA was evaluated for the detection of IgA antibodies in the human leptospirosis. The assay proved to be sensitive and specific when compared with the ELISA-IgM, in the examinated serum samples. The results found suggest that IgA antibodies became positive later in leptospirosis, and will can be an evolutive indicator in the development of the disease
Resumo:
A new serological test, the gelatin particle agglutination test (GPAT), was used for the serodiagnosis of schistosomiasis mansoni. This technique showed the sensitivity (90.6%) and specificity (97.8%) close to those of enzyme-linked immunosorbent assay. The GPAT can be easily and rapidly performed without specialized equipment, by using lyophilized antigen-coated gelatin particles. The test also seems to be useful for mass screening of Schistosoma infection in field conditions.
Resumo:
A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.
Resumo:
The sensitivity and specificity of an enzyme-linked immunosorbent assay (ELISA) for the detection of circulating antigens from toxic components of Tityus serrulatus scorpion venom was determined in patients stung by T. serrulatus before antivenom administration. Thirty-seven patients were classified as mild cases and 19 as moderate or severe cases. The control absorbance in the venom assay was provided by serum samples from 100 individuals of same socioeconomic group and geographical area who had never been stung by scorpions or treated with horse antisera. The negative cutoff value (mean + 2 SD) corresponded to a venom concentration of 4.8 ng/ml. Three out of the 100 normal sera were positive, resulting in a specificity of 97%. The sensitivity of the ELISA when all cases of scorpion sting were included was 39.3%. When mild cases were excluded, the sensitivity increased to 94.7%. This study showed that this ELISA can be used for the detection of circulating venom toxic antigens in patients with systemic manifestations following. T. serrulatus sting but cannot be used for clinical studies in mild cases of envenoming since the test does not discriminate mild cases from control patients.
Resumo:
A Dot enzyme-linked immunosorbent assay (Dot-ELISA) was standardized and evaluated for the serodiagnosis of human toxoplasmosis. Out of 538 serum samples tested by the immunofluorescence test for toxoplasmosis (IFAT-IgG) as reference test, 183 (34%) were positive at cut off 1:16 and 192 (36%) were positive for Dot-ELISA-IgG at cut-off 1:256. For Dot-ELISA, co-positivity was 0.94, co-negativity 0.94 and concordance 0.88 in relation to IFAT-IgG. These results suggest the usefulness of Dot-ELISA (cut-off titer of 1:256) for the serodiagnosis of human toxoplasmosis. The main advantage of this technique is simplicity, positive test can be visually identified (colored precipitate). It does not require a special equipment and it can be used as a qualitative test to screen large numbers of samples or as a quantitative assay to determine end-point titration of individual sera.
Resumo:
An immunoprecipitation technique, ELIEDA (enzyme-linked-immuno-electro-diffusion assay), was evaluated for the diagnosis of Schistosoma mansoni infection with low worm burden. One hundred of serum samples from patients excreting less than 600 eggs per gram of feces (epg), with unrelated diseases and clinically healthy subjects were studied. In patients with egg counts higher than 200 epg, the sensitivities of IgM and IgG ELIEDA were 1.000 and 0.923, respectively, not differing from other Serologic techniques, such as indirect hemaglutination (IHAT), immunofluorescence (IFT) tests and immuno-electrodiffusion assay (IEDA). However in patients with low egg counts (< 100 epg), the IgG ELIEDA provided better results (0.821) than IgM ELIEDA (0.679), showing sensitivity that did not differ from that of IgG IFT (0.929), but lower than that of IgM IFT (0.964). However, its sensivity was higher than that found with IHAT (0.607) and IEDA (0.536). The specificity of IgG ELIEDA was comparable to that of other techniques. The data indicate that IgG ELIEDA might be useful for the diagnosis of slight S. mansoni infections, and the cellulose acetate membrane strips can be stored for further retrospective studies.