68 resultados para 3D FIBER DEPOSITION

em Scielo Saúde Pública - SP


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Chronic obstructive pulmonary disease (COPD) is associated with inflammatory cell reactions, tissue destruction and lung remodeling. Many signaling pathways for these phenomena are still to be identified. We developed a mouse model of COPD to evaluate some pathophysiological mechanisms acting during the initial stage of the disease. Forty-seven 6- to 8-week-old female C57/BL6 mice (approximately 22 g) were exposed for 2 months to cigarette smoke and/or residual oil fly ash (ROFA), a concentrate of air pollution. We measured lung mechanics, airspace enlargement, airway wall thickness, epithelial cell profile, elastic and collagen fiber deposition, and by immunohistochemistry transforming growth factor-β1 (TGF-β1), macrophage elastase (MMP12), neutrophils and macrophages. We observed regional airspace enlargements near terminal bronchioles associated with the exposure to smoke or ROFA. There were also increases in airway resistance and thickening of airway walls in animals exposed to smoke. In the epithelium, we noted a decrease in the ciliated cell area of animals exposed to smoke and an increase in the total cell area associated with exposure to both smoke and ROFA. There was also an increase in the expression of TGF-β1 both in the airways and parenchyma of animals exposed to smoke. However, we could not detect inflammatory cell recruitment, increases in MMP12 or elastic and collagen fiber deposition. After 2 months of exposure to cigarette smoke and/or ROFA, mice developed regional airspace enlargements and airway epithelium remodeling, although no inflammation or increases in fiber deposition were detected. Some of these phenomena may have been mediated by TGF-β1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate age related changes of the elastic fiber system in the interfoveolar ligament, we studied the deep inguinal ring from 33 male cadavers aged from stillborn to 76 years. Selective and alternated staining methods for elastic fibers were performed to differentiate oxytalan, elaunin, and mature elastic fibers. We confirmed quantitative changes of the elastic fiber system with aging. There was a significant and progressive reduction of the oxytalan fibers (responsible for tissue resistance) and a significant increment in the mature elastic and elaunin fibers (responsible for tissue elasticity). Furthermore, there were structural changes in the thickness, shortness and curling of these mature elastic fibers. These changes induced loss of the elastic fiber function and loss of the interfoveolar ligament compliance. These factors predispose individuals to the development of indirect inguinal hernias that frequently emerge in adults and aged individuals, especially above the fifth decade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: O ecocardiograma tridimensional em tempo real (ECO 3D) e a tomografia computadorizada ultra-rápida (CT) são dois novos métodos de análise da fração de ejeção e dos volumes do VE. OBJETIVO: Comparar as medidas da FEVE e dos volumes do VE aferidos pelo ECO 3D e pela CT ultra-rápida. MÉTODOS: Foram estudados pelo ECO 3D e pela CT ultra-rápida de 64 cortes, 39 pacientes consecutivos (27 homens, média etária de 57±12 anos). Foram analisados: FEVE e volumes do VE. Análise estatística: coeficiente de correlação (r: Pearson), teste de Bland & Altman, teste de regressão linear, 95 % IC, p<0,05. RESULTADOS: Medidas do ECO 3D: a FEVE variou de 56,1 a 78,6 (65,5±5,58)%; volume diastólico final variou de 49,6 a 178,2 (87±27,8)ml; volume sistólico final variou de 11,4 a 78 (33,1±13,6)ml. Medidas da CT: a FEVE variou de 53 a 86 (67,8±7,78)%; volume diastólico final variou de 51 a 186 (106,5±30,3) ml; volume sistólico final variou de 7 a 72 (35,5±13,4)ml. As correlações entre ECO 3D e CT foram: FEVE (r: 0,7888, p<0,0001, 95% IC 0,6301 a 0,8843); volume diastólico final (r: 0,7695, p<0,0001, 95% IC 0,5995 a 0,8730); volume sistólico final (r: 0,8119, p<0,0001, 95% IC 0,6673 a 0,8975). CONCLUSÃO: Nesta série, foi observada boa correlação entre as medidas da FEVE e entre os volumes ventriculares aferidos pelo ECO3D e pela CT ultra-rápida de 64 cortes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A terapia de ressincronização cardíaca consiste em tratamento promissor para pacientes com insuficiência cardíaca grave, porém cerca de 30% dos pacientes não apresentam melhora clínica com este tratamento. Por outro lado, aproximadamente 10% dos pacientes submetidos a essa terapia podem apresentar hiper resposta, e a ecocardiografia tridimensional pode oferecer uma opção interessante para a seleção e avaliação de tratamento desses pacientes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: A ecocardiografia consiste em método muito útil para seleção e avaliação de resposta à terapia de ressincronização cardíaca (TRC). O eco 3D já tem seu papel estabelecido na avaliação dos volumes ventriculares e fração de ejeção ventricular esquerda (FEVE) com excelente correlação de resultados quando comparado à RNM. OBJETIVO: Comparar a avaliação dos volumes ventriculares (VDVE, VSVE), FEVE e massa do VE antes e após a TRC pela ecocardiografia bi (Eco 2D) e tridimensional (Eco 3D). MÉTODOS: Foram avaliados 24 pacientes com IC CFIII ou IV (NYHA), ritmo sinusal QRS > 150 ms, em vigência de terapêutica otimizada para IC submetidos a TRC. Foram realizados eletrocardiograma (ECG), avaliação clínica, Eco 2D e 3D antes, três e seis meses após a TRC. A comparação entre as técnicas foi realizada utilizando-se a correlação de Pearson (r). RESULTADOS: No momento basal, a correlação entre os métodos foi de 0,96 para avaliação do VDVE, 0,95 para avaliação do VSVE, 0,87 para FEVE, e 0,72 para massa do VE. Após três meses da TRC, a correlação entre os métodos para análise do VDVE foi de 0,96, 0,95 para VSVE, 0,95 para FEVE, e 0,77 para massa do VE. Após seis meses da TRC, a correlação entre o Eco 2D e 3D para análise do VDVE foi de 0,98, 0,91 para VSVE, 0,96 para FEVE, e 0,85 para massa do VE. CONCLUSÃO: Neste estudo foi observada redução dos VDVE,VSVE, além de melhora da FEVE após a TRC. Houve excelente correlação entre o Eco 2D e o 3D para avaliação dos volumes ventriculares e FEVE, e boa correlação entre os métodos para avaliação da massa ventricular esquerda antes e após a TRC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: Remodelamento ventricular esquerdo (RVE) após IAM caracteriza fator de mau prognóstico. Há pouca informação na literatura sobre o RVE analisado com ecocardiografia tridimensional (ECO 3D) OBJETIVO: Analisar com ECO 3D as modificações geométricas e volumétricas do ventrículo esquerdo (VE) seis meses após IAM em pacientes submetidos a tratamento primário percutâneo. MÉTODOS: Estudo prospectivo com ECO 3D de 21 indivíduos (16 homens, 56 ± 12 anos), acometidos por IAM com elevação do segmento ST. Foi feita a análise morfofuncional (VE) com ECO 3D (volumes, FEVE, índice de esfericidade 3D) até sete dias e seis meses após o IAM. RVE foi considerado para aumento > 15% do volume diastólico final do VE (VDFVE) após seis meses do IAM, comparado ao VDFVE até sete dias do evento. RESULTADOS: Oito (38%) pacientes apresentaram RVE. Medidas ecocardiográficas (n = 21 pacientes): I- até sete dias do IAM: 1- VDFVE: 92,3 ± 22,3 mL; 2- FEVE: 0,51 ± 0,01; 3- índice de esfericidade: 0,38 ± 0,05; II- após seis meses: 1- VDFVE: 107,3 ± 26,8 mL; 2- FEVE: 0,59 ± 0,01; 3- índice de esfericidade: 0,31 ± 0,05. Coeficiente de correlação (r) entre índice de esfericidade até sete dias do IAM e VDFVE aos seis meses (n = 8) após o IAM: r: 0,74, p = 0,0007; (r) entre índice de esfericidade após seis meses do IAM e VDFVE aos seis meses do IAM: r: 0,85, p < 0,0001. CONCLUSÃO: Nesta série, foi observado RVE em 38% dos pacientes seis meses após IAM. O índice de esfericidade tridimensional foi associado à ocorrência de RVE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Histology is the gold standard for diagnosing acute rejection and hepatitis C recurrence after liver transplantation. However, differential diagnosis between the two can be difficult. We evaluated the role of C4d staining and quantification of hepatitis C virus (HCV) RNA levels in liver tissue. This was a retrospective study of 98 liver biopsy samples divided into four groups by histological diagnosis: acute rejection in patients undergoing liver transplant for hepatitis C (RejHCV+), HCV recurrence in patients undergoing liver transplant for hepatitis C (HCVTx+), acute rejection in patients undergoing liver transplant for reasons other than hepatitis C and chronic hepatitis C not transplanted (HCVTx-). All samples were submitted for immunohistochemical staining for C4d and HCV RNA quantification. Immunoexpression of C4d was observed in the portal vessels and was highest in the HCVTx- group. There was no difference in C4d expression between the RejHCV+ and HCVTx+ groups. However, tissue HCV RNA levels were higher in the HCVTx+ group samples than in the RejHCV+ group samples. Additionally, there was a significant correlation between tissue and serum levels of HCV RNA. The quantification of HCV RNA in liver tissue might prove to be an efficient diagnostic test for the recurrence of HCV infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Particle size distribution (PSD) in the soil profile is strongly related to erosion, deposition, and physical and chemical processes. Water cycling and plant growth are also affected by PSD. Material sedimented upstream of the dam constructions formed large areas of deposited farmland (DF) soils on the Chinese Loess Plateau (CLP), which has been the site of the most severe soil erosion in the world. Two DFs without tillage on the CLP were chosen to study the combined effect of erosion and check dams on PSD. Eighty-eight layers (each 10 cm thick) of filled deposited farmland (FDF) soils and 22 layers of silting deposited farmland (SDF) soils of each studied soil profile were collected and 932 soil samples were investigated using laser granulometry. The particle sizes were stratified in both DFs based on soil properties and erosion resistance. The obtained results of clay and silt fractions showed similar horizontal distribution, indicating parallel characteristics of erosion and deposition processes. Fine sand represented the largest fraction, suggesting the preferential detachment of this fraction. The most erodible range of particle sizes was 0.25-0.5 mm, followed by 0.2-0.25 mm in the studied soil profiles. The correlation between particle size and soil water contents tended to increase with increasing water contents in FDF. Due to the abundant shallow groundwater, the relationship between particle size and soil water content in SDF was lost. Further studies on PSD in the DF area are needed to enhance the conservation management of soil and water resources in this region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this work was to compare two methods to estimate the deposition of pesticide applied by aerial spraying. Hundred and fifty pieces of water sensitive paper were distributed over an area of 50 m length by 75 m width for sampling droplets sprayed by an aircraft calibrated to apply a spray volume of 32 L/ha. The samples were analysed by visual microscopic method using NG 2 Porton graticule and by an image analyser computer program. The results reached by visual microscopic method were the following: volume median diameter, 398±62 mum; number median diameter, 159±22 mum; droplet density, 22.5±7.0 droplets/cm² and estimated deposited volume, 22.2±9.4 L/ha. The respective ones reached with the computer program were: 402±58 mum, 161±32 mum, 21.9±7.5 droplets/cm² and 21.9±9.2 L/ha. Graphs of the spatial distribution of droplet density and deposited spray volume on the area were produced by the computer program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to evaluate the effect of tannin sources and levels in rations, on the productive performance and body lipid deposition of Nile tilapias (Oreochromis niloticus) during the finishing phase. Three hundred and forty-two fishes were distributed in 18 tanks. Rations were prepared using corn, sorghum varieties, with low and high tannin content, and tannic acid at 0.08, 0.34, and 0.60%. Weight gain, apparent feed conversion and protein efficiency rate were not influenced by the treatments. The highest body lipid deposition was observed for the tannic acid treatment (14.39%), while the diet containing sorghum with high tannin content yielded leaner body (12.01%) than that of sorghum with low tannin content (13.31%). Diets containing sorghum provided lower levels of visceral fat. Rations with tannin contents did not harm the productive performance of Nile tilapia.