245 resultados para column article
Resumo:
In this study, different solutions to extract vitamin C were tested. High-performance liquid chromatography was chosen and the conditions were based on isocratic elution in reverse phase column. Dehydroascorbic acid was determined indirectly after its reduction using dithiothreitol. The use of metaphosphoric acid to stabilize the vitamin C was shown to be required and it was necessary to neutralize the pH of the extract to apply dithiothreitol. The average recovery was 90% in collard and tomato samples. The presence of oil did not interfere in extraction and the methodology can be used to analyze stir fried vegetables.
Resumo:
This work was aimed on optimization of the matrix solid-phase dispersion (MSPD) technique using gas chromatography for analyzing residues of chlorpyriphos, λ-cyhalothrin, cypermethrin and deltamethrin in tomatoes. The results showed that silica was more efficient for the clean up of extracts, but florisil provided the highest recovery rates. A 2³ complete factorial design was carried out to evaluate the absorbent/sample ratio, presence of co-column (silica) and ultrasonic bath on the extraction rate. The percentage of extraction of the pesticides chlorpyriphos, λ-cyhalothrin, cypermethrin and deltamethrin were 64.7, 88.3, 99.2 and 89.2%, respectively, with relative standard deviations below 5%.
Resumo:
Herein, we report the concentration of ethyl carbamate (EC) and copper in 380 samples of sugar-cane spirit and 45 samples of manioc spirit as determined by GC-MS and FAAS respectively. The cyanide content determined spectrophotometrically is reported for the manioc spirit. Sugar cane spirit produced by alembic distillation (70,0 µg L-1) shown a lower content of EC than samples produced by column distillation (270 µg L-1). No simple correlation between the content of EC and copper for sugar cane spirit as well among the concentration of EC, copper, and cyanide for manioc spirit could be observed.
Resumo:
A high performance liquid chromatography (HPLC) method has been developed for a rapid determination of nimesulide in dissolution studies. Nimesulide was analyzed using 5 µm Lichrospher® RP-18 column (125 x 4 mm i.d.) and mobile phase acetonitrile: phosphate buffer pH=6.0 (55:45) at a flow-rate of 1.0 mL min-1. Detection was carried out at 300 nm at 25 ºC. The method was applied to analysis of nimesulide in in vitro release studies and showed a rapid and efficient analytical alternative for evaluation of dissolution profile of nimesulide.
Resumo:
The objective of this study was to investigate biosurfactant production in solid state by Aspergillus fumigatus in fixed-bed column bioreactors using substrate based on agricultural residues. Without a supplementary carbon source the highest emulsifying activity (EA) was 11.17 emulsifying units (EU) g-1 of substrate at an aeration rate of 148 mL h-1g-1 but in the presence of diesel oil the highest EA value was 9.99 EU g-1 at an aeration rate of 119 mL h-1g-1 of substrate while supplementation with soya oil resulted in only 8.47 EU g-1 of substrate at an aeration rate of 119 mL h-1g-1.
Resumo:
One hundred fifteen cachaça samples derived from distillation in copper stills (73) or in stainless steels (42) were analyzed for thirty five itens by chromatography and inductively coupled plasma optical emission spectrometry. The analytical data were treated through Factor Analysis (FA), Partial Least Square Discriminant Analysis (PLS-DA) and Quadratic Discriminant Analysis (QDA). The FA explained 66.0% of the database variance. PLS-DA showed that it is possible to distinguish between the two groups of cachaças with 52.8% of the database variance. QDA was used to build up a classification model using acetaldehyde, ethyl carbamate, isobutyl alcohol, benzaldehyde, acetic acid and formaldehyde as chemical descriptors. The model presented 91.7% of accuracy on predicting the apparatus in which unknown samples were distilled.
Resumo:
This paper presents the fundamental principles, instrumentation and selected applications of comprehensive two-dimensional gas chromatography (GC × GC). In this technique, introduced in 1991, two capillary columns are coupled and proper modulating interfaces continuously collect the eluate from the first column, transferring it to the second column. The result is a geometric increment in the chromatographic resolution, ensuring separation of extremely complex mixtures in time periods shorter or comparable to those of analysis using conventional gas chromatography and with better detectabilities and sensitivities.
Resumo:
Capillary electrochromatography (CEC) is a separation technique in which the mobile phase flow is based on the application of a voltage across a packed capillary, which generates an electroosmotic flow that transports the analytes along the capillary toward the detector. As it combines the separation mechanisms of high-performance liquid chromatography (HPLC) and of capillary electrophoresis (CE), CEC can be considered a hybrid of HPLC and CE. This review presents some fundamental aspects of CEC and is focused on the instrumental advances of the technique, such as column technology, operation modes and detection systems, presenting recent papers on these topics and some applications and perspectives about CEC.
Resumo:
The aim of this work was to develop and validate an analytical methodology for determination of artemisinin used as antimalaric. The method was based on high performace liquid chromatography, using a CN column with mobile phase composed of methanol : H2O 50:50 (V/V). The results showed that the method presented linearity from 50 to 1500 µg/mL. It was considered selective, accurate, precise according to the specific resolution from ANVISA, the Brazilian regulatory agency.
Resumo:
This paper describes the development and validation of simple and selective analytical method for determination of 3.4-methylenedioxymethamphetamine (MDMA) in Ecstasy tablets, using high performance liquid chromatography with fluorescence detection. Analysis was performed in a reversed phase column (LiChrospher 100 C18, 150 x 4.6 mm, 5 µm), isocratic elution with phosphate buffer 25 mmol/L pH 3.0 and acetonitrile (95:5, v/v). The method presents adequate linearity, selectivity, precision and accuracy. MDMA concentration in analyzed tablets showed a remarkable variability (from 8.5 to 59.5 mg/tablet) although the tablet weights were uniform, indicating poor manufacturing control thus imposing additional health risks to the users.
Resumo:
The lack of accuracy of a chromatographic method can be associated with the matrix effect. This effect is observed in pesticide quantification by gas chromatography when the chromatographic signals of standards prepared in solvents are compared with those of the analyte in extracts of complex matrices. In the competition between the matrix components and the pesticides for the active sites of the liner, a larger amount of pesticides is transferred to the column, giving apparent extractions above 100%. In this work, we discuss factors that contribute to the matrix effect and present some attempts to overcome the problem.
Resumo:
The carrot leaf dehydration conditions in air circulation oven were optimized through response surface methodology (RSM) for minimizing the degradation of polyunsaturated fatty acids, particularly alpha-linolenic (LNA, 18:3n-3). The optimized leaf drying time and temperature were 43 h and 70 ºC, respectively. The fatty acids (FA) were investigated using gas chromatography equipped with a flame ionization detector and fused silica capillary column; FA were identified with standards and based on equivalent-chain-length. LNA and other FA were quantified against C21:0 internal standard. After dehydration, the amount of LNA, quantified in mg/100 g dry matter of dehydrated carrot leaves, were 984 mg.
Resumo:
An alternative methodology for analysis of acetaminophen (Ace), phenylephrine (Phe) and carbinoxamine (Car) in tablets by ion-pair reversed phase high performance liquid chromatography was validated. The pharmaceutical preparations were analyzed by using a C18 column (5 μm, 300 mm, 3.9 mm) and mobile phase consisting of 60% methanol and 40% potassium monobasic phosphate aqueous solution (62.46 mmol L-1) added with 1 mL phosphoric acid, 0.50 mL triethylamine and 0.25 g sodium lauryl sulfate. Isocratic analysis was performed under direct UV detection at 220 nm for Phe and Car and at 300 nm for Ace within 5 min.
Resumo:
Fixed-bed column studies were undertaken to evaluate the performance of a commercial Brazilian activated carbon in removing Pb(II) from aqueous environment. Breakthrough points were found out for the metal adsorption by varying different operating parameters like feed concentrations (10 and 20 mg L-1) and bed heights (0.5, 1.5 and 2.8 cm). A good agreement was observed between the experimental data and the values predicted by the bed depth service time (BDST) model. Regeneration of the exhausted columns was possible with HCl, and the adsorption capacity was maintained after three adsorption-desorption cycles.
Resumo:
A gas chromatographic method has been developed for the assay of fluvastatin sodium (FLU). FLU was silylated with N,O-bis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 90 ºC for 30 min and analysed in a DB-1 column by capillary gas chromatograph with a flame ionization detector. The method was validated. The assay was linear over the concentration range at 10.0 to 50.0 µg mL-1. The limit of detection and the limit of quantitation were 1.0 and 3.0 µg mL-1, respectively. The recoveries of FLU derivatives were in the range of 99.25-99.80%. In inter-day and intra-day analysis, the values of relative standard deviation (%) and the relative mean error (%) were found between 0.20-0.80% and -0.20-0.75%, respectively. The developed method was succesfully applied to analyze the FLU content in tablet formulation. The results were statistically compared with those obtained by the official method, and no significant difference was found between the two methods. Therefore, it can be recommended for the quality control assay of FLU in pharmaceutical industry.