176 resultados para carga líquida
Resumo:
This study optimized and validated the liquid-liquid extraction technique with partition at low temperature (LLE-PLT) for identification and quantification of four pesticides (chlorpyrifos, λ-cyhalothrin, permethrin, bifenthrin) in water samples. Analyses were performed by HPLC-UV. The technique was efficient for pesticide recovery with extraction exceeding 86%. Chromatographic response was linear for the four compounds in the 10-45 µg L-1 range, with correlation coefficients greater than 0.99. Limits of detection and quantitation were less than 3.5 µg L-1 and equal to 10 µg L-1, respectively. The proposed method was applied to 29 water samples from the Jaíba Project in northern Minas Gerais.
Resumo:
A multiresidue method using HPLC/DAD for the determination of fourteen pesticides in water based on SPE, using SDVB (styrene divynilbenzene copolymer) as adsorbent was validated. Recoveries from 61 to 120%, relative standard deviation between 2 and 15% and detection limits from 0.07 to 0.75 µg L-1 were obtained. It was applied to 66 surface water samples collected in a degraded area at the headwaters of São Lourenço river, Mato Grosso, Brazil. Eight pesticides were detected in concentrations ranging from 0.15 to 35.25 µg L-1. Considering ecotoxicological data, carbendazim and carbofuran may represent a risk to aquatic organisms. These results draw attention to the contamination of this vulnerable degraded area.
Resumo:
This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.
Resumo:
This work describes three C8-stationary phases for high performance liquid chromatography based on silica metallized with ZrO2, TiO2 or Al2O3 layers, having poly(methyloctylsiloxane) immobilized onto their surfaces. The stationary phases were characterized using XRF, XAS, FTIR, SEM and elemental analysis to determine the physical characteristics of the oxide and polysiloxane layers formed on the surfaces and chromatographically to evaluate the separation parameters. The results show the changes on the silica surface and allowed proposing a structure for the oxide layer, being observed tetrahedral and octahedral structures, what is completely new in the literature. The formation of a homogeneous layer of metallic oxide (TiO2 and ZrO2) was observed on the silica. The C8-titanized and C8-aluminized stationary phases presented good chromatographic performances, with good values of asymmetry and efficiency. All stationary phase presented few loss of the polymeric layer after the HPLC, indicating that this layer is well attached on the metalized support.
Resumo:
Blooms of cyanobacteria represent a public health risk due to their cyanotoxins such as microcystins. Liquid chromatography techniques to separate and quantify microcystins invariably use acetonitrile as the organic component of the mobile phase. The price and availability of acetonitrile together with its elevated toxicity encourage the validation of acetonitrile-free methods of microcystin analysis. In this work, methanol was employed as the organic solvent of the mobile phase and the validation method was performed with different environmental water samples. The method showed limits of detection between 0.17 and 0.25 µg/L and of quantification between 0.55 and 0.82 µg/L for the microcystin variants: -RR, -YR, -LR, -LA.
Resumo:
Validation of a rapid method for the determination of ascorbic, citric, fumaric and tartaric acids in stored pulp fruit and its application as a quality parameter was performed. The validation parameters showed that for the four evaluated acids, the method presented low limits of detection (LOD) and quantification (LOQ), indicating good precision and accuracy, thus representing an important tool for quality assessment of stored fruit pulp. The results showed that the concentration of organic acids generally decreased with longer storage time in the fruit pulp under study. Amongst all the organic acids under investigation, ascorbic proved the least stable.
Resumo:
The aim of this work was to develop and validate an analytical method for the quantification of tioconazole in polymeric nanocapsule suspensions by high performance liquid chromatography with UV detection. The analysis was performed with a mobile phase composed of methanol:water (80:20) and 0.18% ammonium hydroxide; RP-18 column and UV detection at 219 nm. The method proved to be linear in the concentration range of 5-50 µg mL-1 (r = 0.9999), specific, precise (repeatability RSD = 1.42%, intermediate precision RSD = 1.17%), accurate (98 - 102%) and robust (RSD < 2.0%). In conclusion, a simple and rapid method was validated proving suitable for quantification of tioconazole in polymeric nanocapsules.
Resumo:
Carbamazepine, phenobarbital and phenytoin were determined in dried blood spots (DBS) by high performance liquid chromatography, after extraction of 8 mm DBS using a mixture of acetonitrile and methanol. Analytes were separated by reversed-phase chromatography, with a run time of 17 minutes. Intra-assay and inter-assay precisions were in the 5.3 to 8.4% and 3.3 to 5.2% ranges, respectively. Accuracy was in the 98.8 to 104.3% range. The method had sensitivity to detect all analytes at levels below minimum therapeutic concentrations. The analytes were stable at 4 ºC and room temperature for up to 12 days and at 45 ºC for 9 days. The method was applied to 14 paired clinical samples of blood serum and DBS.
Resumo:
The constant evolution of science and the growing demand for new technologies have led to new techniques in instrumentation that can improve detection, separation, resolution, and peak capacity. Comprehensive two-dimensional liquid chromatography (LC×LC) is presented as a powerful tool in complex sample analyses. During an analysis, a sample is subjected to two independent separation mechanisms that are combined, resulting in increased resolving power. For appropriate application of LC×LC, understanding the influence of parameters that require optimization is necessary. The main purpose of optimization is to predict the combination of stationary phases, separation conditions, and instrumental requirements to obtain the best separation performance. This review discusses theoretical, intrumental, and chemometric aspects of LC×LC and focuses on its applications in foods. It aims to provide a clear understanding of the aspects that can be used as strategies in the optimization of this analytical method.
Resumo:
Liquid chromatography is often used for the determination of pesticide multiresidues in foods. In Brazil, the strawberry crop is an example of a food with high levels of irregularities because of the application of pesticides. This is a major concern from the perspective of food safety, environmental protection, and certification for food export. The purpose of this study is to evaluate and compare chromatographic separation and detection methods in relation to a newly developed and validated method using ultra high performance liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS) for the analytical determination of pesticides in strawberries. The comparisons were based on evaluations of the analysis time, consumption of the solvent in the mobile phase, injection volume, detectability, matrix effect, and recovery. The results showed that the LC–MS/MS and UHPLC–MS/MS techniques were both extremely efficient at analyzing pesticide residues with different physico-chemical parameters that were present at low concentrations in a complex matrix. The UHPLC separation method provided better chromatographic performance and productivity, which contributed favorably to routine analytical determinations. Detection by MS/MS had better detectability and selectivity compared with the diode array detector.
Resumo:
O objetivo deste trabalho foi propor um método rápido e sensível para a determinação simultânea de catecolaminas (noradrenalina e adrenalina) em amostras de órgãos reprodutores de ratos machos por Cromatografia Líquida de Alta Eficiência com Detecção Eletroquímica. O método envolveu a injeção direta do extrato ácido da amostra de tecido em uma coluna cromatográfica com superfície interna de fase (HSA-C18), empregando a fase móvel foi composta por solução de ácido metanosulfônico a 0.013mol L-1 (pH = 3.0): acetonitrila (96:4v/v), 0,033g ácido heptanosulfônico e 0,01g EDTA. A detecção dos analitos foi obtida, através de um detector eletroquímico L-ECD-6-A-Shimadzu com potencial em 85mV. A extração das catecolaminas foi utilizado ácido perclórico a 0,4 mol L-1. A extração do analito resultou em valores de recuperação entre 56% e 114%, e coeficiente de variação entre 3,8% a 23%. O limite de quantificação do método ficou entre 0,008 e 0,030 ng mg-1 para a noradrenalina, e 0,009 e 0,051 ng mg-1 para a adrenalina. Em conclusão, o método analítico foi validado e aplicado com desempenho às amostras reais de tecidos biológicos de ratos, permitindo a determinação de baixas concentrações das catecolaminas estudadas. O método apresentou várias vantagens: rapidez, alta precisão, boa seletividade e, ainda, não requer o pré-tratamento da amostra.
Resumo:
Esta pesquisa teve como objetivos a avaliar da carga de trabalho físico exigida em operações de produção de mudas em viveiros que abastecem os canteiros ornamentais do Distrito Federal e classificar as atividades desenvolvidas no viveiro, conforme a sua exigência física, propondo uma reorganização ergonômica para melhoria dos níveis de segurança, saúde, bem-estar e satisfação dos trabalhadores. A carga de trabalho físico foi avaliada por intermédio do levantamento da freqüência cardíaca durante a jornada de trabalho nas diversas fases do ciclo de trabalho, segundo a metodologia proposta por Apud (1997), nas atividades de enchimento dos recipientes plásticos com substrato, abastecimento da carreta com os recipientes plásticos, encanteiramento, plantio de mudas e expedição. Com base nos dados coletados, foram calculadas as médias das freqüências cardíacas das cinco etapas analisadas. De acordo com os resultados obtidos, a freqüência cardíaca média das etapas foi de 97,96 bpm para a fase de enchimento dos recipientes, de 111,7 bpm para o abastecimento da carreta, de 126,26 bpm para o encanteiramento, de 90,75 bpm para o plantio das mudas nos recipientes e de 115,01 bpm para a expedição. A atividade de encanteiramento ultrapassou a carga cardiovascular máxima de 40%, sendo necessário, portanto, um repouso de 12,8 min por hora trabalhada durante a jornada de trabalho. A maior exigência física no trabalho foi verificada nos trabalhadores que exercem a função de encanteiramento (trabalho físico pesado), seguido do abastecimento da carreta e expedição (ambos moderadamente pesados). As atividades de enchimento dos recipientes e plantio das mudas nos recipientes tiveram a exigência física classificada como leve.
Resumo:
Este estudo teve como objetivo principal avaliar a carga de trabalho físico e a análise biomecânica de 20 trabalhadores da carbonização em fornos tipo "rabo-quente", localizados no Norte do Estado de Minas Gerais. Para análise da freqüência cardíaca, foi utilizado o sistema Polar Eletro Oy da Finlândia. O tempo consumido pelos trabalhadores por atividade foi avaliado através do método de cronometagem individual e a análise biomecânica, realizada por programa computacional desenvolvido pela Universidade de Michigan. Os resultados evidenciaram que a carga cardiovascular exigida para a realização da atividade era de 44,5% e classificada como moderadamente pesada. A operação que mais consumia tempo de trabalho era a vedação. Havia risco de compressão no disco vertebral L5 - S1 na operação de carga, durante as fases de levantamento da rede e remoção de tora.
Resumo:
A operação de baldeio florestal está relacionada ao uso de máquinas, as quais trafegam numa mesma linha várias vezes ou aleatoriamente, o que pode causar compactação do solo, alterando o meio onde o sistema radicular se desenvolve e reduzindo a produtividade. Além do número de passadas, a carga de madeira transportada pode afetar a compactação do solo quando as pressões aplicadas pelas máquinas excederem a capacidade de suporte de carga desse solo. Os objetivos deste estudo foram: a) propor modelo de capacidade de suporte de carga para Latossolo Vermelho-Amarelo no Município de Santa Maria de Itabira, MG, em razão da pressão de pré-consolidação e da umidade; e b) determinar, com o uso deste modelo, o efeito da intensidade de tráfego e da carga de Forwarder sobre a estrutura do solo. Para a obtenção dos modelos de capacidade de suporte de carga, 20 amostras indeformadas de solo foram coletadas nas profundidades de 0-3 e 10-13 cm no local onde não houve tráfego. Foram também coletadas 10 amostras indeformadas em cada profundidade, onde o Forwarder trafegou duas, quatro e oito vezes e no local onde o Forwarder trafegou quatro vezes com 1/3 (3 m³), 2/3 (6 m³) e 3/3 (9 m³) de sua carga. As amostras indeformadas foram utilizadas nos ensaios de compressão uniaxial. Determinaram-se também a textura, o teor de matéria orgânica e a densidade de partículas e densidade dos solos. O modelo de capacidade de suporte de carga do LVA é expresso pela equação s p = 10(2,71 - 1,36 U). Todas as intensidades de tráfego causaram compactação no solo nas duas profundidades estudadas, sendo quatro passadas as que causaram maior compactação do solo, e, à medida que a carga do Forwarder aumentou, a compactação do solo também aumentou nas duas profundidades.