213 resultados para bico rotativo padrão de deposição
Resumo:
In a tropical coastal area. During 6 months the composition of rain samples collected simultaneously over 24h with an open collector and with an automatic opened collector (KFA - J¸lich Type) at 500m of the Atlantic coastline of Salvador were compared. All average concentrations were higher for the "total" samples than for the "wet only" samples, except for hydrogen ions, nitrate and ammonium.
Resumo:
Cadmium UPD on Au was studied by voltammetric and microgravimetric measurements. In the oxide formation/reduction potential region, a mass increasing/decreasing of 32 ng cm-2 was associated to incorporation/elimination of one oxygen per active site. The modifications promoted in the voltammetric and mass profiles by 10-5 M Cd(ClO4)2 are restricted to potentials more negative than 0.4 V. After a 120 s potential delay at 0.05 V, the positive sweep reveals an anodic peak with charge of 40 muC cm-2 and mass decrease of 22 ng cm-2, associated to Cd ads dissolution. Sulphate or chloride was added to the solution without significant influence, due to the low coverage with Cd or anions.
Resumo:
Simultaneous electrolytic deposition is proposed for minimization of Cu2+ and Pb2+ interferences on automated determination of Cd2+ by the Malachite Green-iodide reaction. During electrolysis of sample in a cell with two Pt electrodes and a medium adjusted to 5% (v/v) HNO3 + 0.1% (v/v) H2SO4 + 0.5 mol L-1 NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. With 60 s electrolysis time and 0.25 A current, Pb2+ and Cu2+ levels up to 50 and 250 mg L-1 respectively, can be tolerated without interference. With on-line extraction of Cd2+ in anionic resin minicolumn, calibration graph in the 5.00 - 50.0 µg Cd L-1 range is obtained, corresponding to twenty measurements per hour, 0.7 mg Malachite Green and 500 mg KI and 5 mL sample consumed per determination. Results of the determination of Cd in certified reference materials, vegetables and tap water were in agreement with certified values and with those obtained by GFAAS at 95% confidence level. The detection limit is 0.23 µg Cd L-1 and the RSD for typical samples containing 13.0 µg Cd L-1 was 3.85 % (n= 12).
Resumo:
In this work two procedures were proposed for analytical curves construction using a single standard solution employing a flow injection system with solid phase spectrophotometric detection (FI-SPS). A flow cell contends the chromogenic reagent 1-(2-tiazolylazo)-2-naphtol was positioned on the optical path. The first procedure was based on controlled concentration of analyte on solid phase and the relations between absorbance and the total volume of injected allowed the calculation of analyte concentration. The second procedure was developed employing controlled dispersion/retention in flow system where analyte concentration was obtained by exploiting the relation between transient signals of samples and single standard solution at equivalent reading time. The procedures were successfully applied for zinc determination in synthetic solutions with good precision and accuracy at 95% confidence level.
Resumo:
In this work we show how to build a piece of equipment for depositing thin films by the dip-coating process, using inexpensive components easily found on the market. This equipment allows us to control the dipping and pulling velocity at which the substrate is put in the film precursor solution, two very important parameters for obtain thin films. This article discusses the construction of the mechanical and electric parts of the equipment, a simple method to interface it to a computer and the development of the software to control the dip-coating parameters.
Resumo:
The hydrated sodium salt of EDTA, Na2H2Y·2H2O, cannot be used as a primary standard for titrations due to uncertainties in the water content. An alkalimetric titration of the homogenized solid in the presence of a small excess of BaCl2·2H2O allows one to titrate quantitatively the released two hydrogen cations with end-point indication by phenolphthalein or potentiometry. This leads one to calculate the average molar mass of the reagent and its water content, allowing to use it to prepare EDTA standard solutions. One titrated sample led to the formula Na2H2Y·1.876 H2O, and 370.01 g.mol-1 for the average molar mass.
Resumo:
The osseointegrated titanium implants are reliable and safe alternatives to treatments for long periods of time. For surface modification, thermal aspersion of TiO2 was used. The samples with and without TiO2 were treated with NaOH and SBF in order to obtain a layer of HA. Characterization was done by SEM and FTIR. The images of HA obtained by SEM show a uniform morphology and a porous structure with spherical particles. The IR spectra show that the surface of Ticp/ TiO2 is more favorable for the HA deposit, as can be seen by the increase of the crystalline structure and the very intense and defined bands of the OH group of HA that is verified about 3571 and 630 cm-1. Thus the Ticp/ TiO2 surface presents a satisfactory nucleation of HA when compared to Ticp.
Resumo:
A method for ester content determination in soybean methyl biodiesel was studied, using ethyl oleate as internal standard. A biodiesel sample was analyzed and had its purity estimated as 92.8%. Method accuracy was evaluated by comparison with the result obtained via EN14103, with a relative difference of 0.1%. Repetitivity and intermediate precision were estimated as 2 and 1.5%, respectively.
Resumo:
In this work, a TPR (Temperature Programmed Reduction) system is used as a powerful tool to monitor carbon nanotubes production during CVD (Chemical Vapour Deposition), The experiments were carried out using catalyst precursors based on Fe-Mo supported on Al2O3 and methane as carbon source. As methane reacts on the Fe metal surface, carbon is deposited and H2 is produced. TPR is very sensitive to the presence of H2 and affords information on the temperature where catalyst is active to form different forms of carbon, the reaction kinetics, the catalyst deactivation and carbon yields.
Resumo:
This work reports on the SERS activity of a nanostructured substrate that was obtained by electrodepositing gold over a template consisting of polystyrene microspheres. This substrate displayed superior SERS performance for the detection of 4-merctaptopyridine as compared to a conventional roughened Au electrode. In order to investigate the substrate capability for the detection at low concentration limits, a series of Rhodamine 6G (1 nM) spectra were registered. Our spectral dynamics data is in agreement with single-molecule behavior, showing that the control over the substrate morphology is crucial to enable the production of highly reproducible and sensitive SERS substrates.
Resumo:
Two sampling points were chosen and forty samples were collected between January and December 2006 at Alto Sorocaba basin. The rainwater pH varied from 5.46 to 6.36 (Ibiúna) and 5.26 to 6.81 (Itupararanga), being Ca2+ the main ion responsible for controlling the rainwater pH. The ionic concentrations decreased in the following order: Ca2 +>Na+> Mg2+>K+ for cations and SO4(2-)>HCO3->NO 3->Cl- >PO4(3-) for anions. The annual atmospheric deposition appeared to be controlled mostly by following sources: mining activities and cement factories (Ca2+ and HCO3-), natural soil dust (Na+, Mg2+ and HCO3-), fossil fuel burning (SO4(2-)) and agriculture activities (K+, NO3- and PO4(3-)).
Resumo:
This paper presents a quality assurance and quality control protocol in order to ensure the reliability of analytical results for the determination of acid volatile sulfides in environmental samples by potentiometry. The monitoring of the ion selective sensor readings must be realized continually and particularly in this situation where the analyte is susceptible to transformation and volatilization. Potentiometry with the standard addition was presented as a rapid, accurate, precise, feasible as well as a low cost technique. Concentrations of the analyte in the range of 0.49 to 1.02 mg L-1 were tested with percentage recoveries varying from 89 to 113%.
Resumo:
The aim of this review is to take a look at Cold War era nuclear tests signatures found in Brazilian coastal sediments. Both137Cs and 240+239Pu signatures have been documented in mangrove, coastal mudflats and continental shelf sediments, associated with above ground nuclear tests beginning in the 1950's. The dates associated to the anthropogenic radionuclide signatures 137Cs and 240+239Pu along sediment columns are confirmed by 210Pb geochronology in many of the studies highlighted in this review. The results outlined in this review characterize the extent to which nuclear fallout products reach the Brazilian coast in quantities sufficient for detection, allowing the use of these radioisotopes as geochronometers.
Resumo:
This work studies the influence of the film deposition process on light emission performance and on threshold voltage of OLEDs, with architecture glass/ITO/PEDOT:PSS/PVK/Alq3/Al. The commercial PVK was dissolved in different solvents such as: chloroform, tetrahydrofuran, 1,2,4-trichlorobenzene and trimethylpentane. OLEDs were characterized by current-voltage and revealed a significant influence of the solvents, although all devices emitted green electroluminescence. A difference in threshold voltage up to 10 V was observed among OLEDs prepared from different solvents. The 1,2,4-trichlorobenzene showed best performance, presenting lowest treshold voltage (≈ 6 V), followed by tetrahydrofuran (≈ 8 V), trimethylpentane (≈ 14 V) and chloroform (≈ 16 V).
Resumo:
A obtenção de genótipos resistentes à brusone é uma das maiores dificuldades para os programas de melhoramento genético de arroz (Oryza sativa) devido à variabilidade do fungo Pyricularia grisea. Esta diversidade do fungo tem sido caracterizada por meio de marcadores moleculares de DNA e pela virulência de isolados do patógeno demonstrada em genótipos de arroz com diferentes genes de resistência à brusone. Os marcadores moleculares permitem identificar isolados de P. grisea em grupos geneticamente relacionados denominados de linhagens e as linhas isogênicas em grupos com padrões de virulência iguais ou muito similares. Assim, este trabalho foi realizado com os objetivos de verificar os padrões moleculares e de virulência de isolados de P. grisea do Rio Grande do Sul. O DNA de 51 isolados monospóricos de P. grisea obtidos do Rio Grande do Sul foi utilizado em reações de PCR com os oligonucleotídeos iniciadores baseados na seqüência repetitiva Pot2. Os mesmos isolados também foram utilizados para inocular plantas de seis linhas isogênicas de arroz. A análise estatística indicou a ocorrência de seis linhagens e sete grupos de virulência. A ocorrência de isolados que causam reações de compatibilidade em linhas isogênicas que contêm o alelo Pi-1 foi maior do que aquelas que possuem o alelo Pi-2. As reações de compatibilidade na linha isogênica C 101 A51 caracterizaram-se pela baixa severidade, em geral, avaliadas como sendo de nota 4. Não foi verificada uma relação direta entre os padrões moleculares e de virulência dos isolados avaliados.