169 resultados para analytical parameters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess topical delivery studies of glycoalkaloids, an analytical method by HPLC-UV was developed and validated for the determination of solasonine (SN) and solamargine (SM) in different skin layers, as well as in a topical formulation. The method was linear within the ranges 0.86 to 990.00 µg/mL for SN and 1.74 to 1000.00 µg/mL for SM (r = 0.9996). Moreover, the recoveries for both glycoalkaloids were higher than 88.94 and 93.23% from skin samples and topical formulation, respectively. The method developed is reliable and suitable for topical delivery skin studies and for determining the content of SN and SM in topical formulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use and characterization of the first Certified Reference Material (CRM) of Brazilian coal for analytical quality control are presented. All results were determined within the limits of repeatability and reproducibility allowed under the standards. Notable among the characterization parameters was the mineral matter content (45.39%) obtained by an alternative procedure showing a low relative error (-2.1%) compared to the standard technique (low ashing temperature). The possible expanded application of this CRM application in national laboratories, beyond the certificated and reference parameters, has advantages such as lower cost and easy availability, but round robin tests must be performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the inherent limitations of the analytical methods of measurement, environmental exposure data often present observations described as below a certain detection limit, also called left-censored data. Censored data directly interferes in almost all types of statistical analyzes, including descriptive parameters, hypothesis testing, confidence intervals, correlations and regressions. In this work, we investigated the performance of the main classes of methods from major publications available in the literature, considering their advantages and limitations. Some criteria for selecting the best method of dealing with censored data are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A statistical mixture-design technique was used to study the effects of different solvents and their mixtures on the yield, total polyphenol content, and antioxidant capacity of the crude extracts from the bark of Schinus terebinthifolius Raddi (Anacardiaceae). The experimental results and their response-surface models showed that ternary mixtures with equal portions of all the three solvents (water, ethanol and acetone) were better than the binary mixtures in generating crude extracts with the highest yield (22.04 ± 0.48%), total polyphenol content (29.39 ± 0.39%), and antioxidant capacity (6.38 ± 0.21). An analytical method was developed and validated for the determination of total polyphenols in the extracts. Optimal conditions for the various parameters in this analytical method, namely, the time for the chromophoric reaction to stabilize, wavelength of the absorption maxima to be monitored, the reference standard and the concentration of sodium carbonate were determined to be 5 min, 780 nm, pyrogallol, and 14.06% w v-1, respectively. UV-Vis spectrophotometric monitoring of the reaction under these conditions proved the method to be linear, specific, precise, accurate, reproducible, robust, and easy to perform.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conventional curriculum of Analytical Chemistry undergraduate courses emphasizes the introduction of techniques, methods and procedures used for instrumental analysis. All these concepts must be integrated into a sound conceptual framework to allow students to make appropriate decisions. Method calibration is one of the most critical parameters that has to be grasped since most analytical techniques depend on it for quantitative analysis. The conceptual understanding of calibration is not trivial for undergraduate students. External calibration is widely discussed during instrumental analysis courses. However, the understanding of the limitations of external calibration to correct some systematic errors is not directly derived from laboratory examples. The conceptual understanding of other calibration methods (standard addition, matrix matching, and internal standard) is imperative. The aim of this work is to present a simple experiment using grains (beans, corn and chickpeas) to explore different types of calibration methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The constant evolution of science and the growing demand for new technologies have led to new techniques in instrumentation that can improve detection, separation, resolution, and peak capacity. Comprehensive two-dimensional liquid chromatography (LC×LC) is presented as a powerful tool in complex sample analyses. During an analysis, a sample is subjected to two independent separation mechanisms that are combined, resulting in increased resolving power. For appropriate application of LC×LC, understanding the influence of parameters that require optimization is necessary. The main purpose of optimization is to predict the combination of stationary phases, separation conditions, and instrumental requirements to obtain the best separation performance. This review discusses theoretical, intrumental, and chemometric aspects of LC×LC and focuses on its applications in foods. It aims to provide a clear understanding of the aspects that can be used as strategies in the optimization of this analytical method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractThis work describes the development of a biosensor based on the tyrosinase enzyme (Tyr) for the determination of phenol (PHEN) in laboratory effluent samples derived from ammoniacal nitrogen analysis of the water samples from the Muquém dam in the city of Cariús, CE, using square-wave voltammetry (SWV). The electrode modification consisted of the immobilization of gold nanoparticles, multi-walled carbon nanotubes, cobalt phthalocyanine, and Tyr on a glassy carbon electrode. The electrolyte, pH, enzyme quantity, and voltammetric parameters were optimized to detect PHEN. The analytical curves presented a linear range from 4.97 × 10-6 mol L-1 to 6.10 × 10-5 mol L-1, and the detection limit (DL) and quantitation limit (QL) values were 4.81 × 10-6 mol L-1 and 4.97 × 10-6mol L-1, respectively. The repetition of measurements with the same biosensor and repetition for three other prepared biosensors exhibited a relative standard deviation (RSD) of 5.50 and 1.75%, respectively. The percentage recovery of PHEN in effluent samples varied from 86.40 to 105.04%. The stability of the biosensor was evaluated (at 21 days) with satisfactory results, showing 97.86% of the initial response. Moreover, the DL and recovery percentages agreed with the established values from CONAMA and ABNT, respectively. Thus, the electrode configuration developed seems a promising tool in the detection and quantification of PHEN in complex samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liquid chromatography is often used for the determination of pesticide multiresidues in foods. In Brazil, the strawberry crop is an example of a food with high levels of irregularities because of the application of pesticides. This is a major concern from the perspective of food safety, environmental protection, and certification for food export. The purpose of this study is to evaluate and compare chromatographic separation and detection methods in relation to a newly developed and validated method using ultra high performance liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS) for the analytical determination of pesticides in strawberries. The comparisons were based on evaluations of the analysis time, consumption of the solvent in the mobile phase, injection volume, detectability, matrix effect, and recovery. The results showed that the LC–MS/MS and UHPLC–MS/MS techniques were both extremely efficient at analyzing pesticide residues with different physico-chemical parameters that were present at low concentrations in a complex matrix. The UHPLC separation method provided better chromatographic performance and productivity, which contributed favorably to routine analytical determinations. Detection by MS/MS had better detectability and selectivity compared with the diode array detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound as a metrology tool has many applications in health care, industrial, and chemical analyses. Ultrasonic techniques are rapid, low-cost, non-invasive, and highly repeatable. Although ultrasound can be used to measure emulsions, no effort had been made thus far to optimize its sensitivity for metrological analysis. In this work, a technique for analyzing oil in water was validated. The wave velocity and attenuation were chosen as the ultrasonic parameters. The technique was implemented in the boundary region established by law for effluents from industrial plants involved with biofuel manufacturing. A technical effort of this study was to establish stable emulsions in concentrations close to the desired limit of study. The phase behaviours of pseudo-ternary oil, sodium chloride, and sodium lauryl sulphate were studied. The composition in the widest region of the diagram allowed for the formation of a stable emulsion, from which the ultrasound measurement was carried out. An analytical curve was obtained using ultrasonic attenuation to determine the content of oils and greases in wastewater ranging 15–240 ppm. The speed of sound did not appear to be an applicable parameter for this application. The technique was demonstrated to be an important alternative solution for the continuous monitoring of wastewater with regard to oil concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microencapsulation of palm oil may be a mechanism for protecting and promoting the controlled release of its bioactive compounds. To optimize the microencapsulation process, it is necessary to accurately quantify the palm oil present both external and internal to the microcapsules. In this study, we developed and validated a spectrophotometric method to determine the microencapsulation efficiency of palm oil by complex coacervation. We used gelatin and gum arabic (1:1) as wall material in a 5% concentration (w/v) and palm oil in the same concentration. The coacervates were obtained at pH 4.0 ± 0.01, decanted for 24 h, frozen (−40 ºC), and lyophilized for 72 h. Morphological analyzes were then performed. We standardized the extraction of the external palm oil through five successive washes with an organic solvent. We then explored the best method for rupturing the microcapsules. After successive extractions with hexane, we determined the amount of palm oil contained in the microcapsules using a spectrophotometer. The proposed method was shown to be of low cost, fast, and easy to implement. In addition, in the validation step, we confirmed the method to be safe and reliable, as it proved to be specific, accurate, precise, and robust.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some aspects of the application of electrochemical impedance spectroscopy to studies of solid electrode / solution interface, in the absence of faradaic processes, are analysed. In order to perform this analysis, gold electrodes with (111) and (210) crystallographic orientations in an aqueous solution containing 10 mmol dm-3 KF, as supporting electrolyte, and a pyridine concentration varying from 0.01 to 4.6 mmol dm-3, were used. The experimental data was analysed by using EQUIVCRT software, which utilises non-linear least squares routines, attributing to the solid electrode / solution interface behaviour described by an equivalent circuit with a resistance in series with a constant phase element. The results of this fitting procedure were analysed by the dependence on the electrode potential on two parameters: the pre-exponential factor, Y0, and the exponent n f, related with the phase angle shift. By this analysis it was possible to observe that the pyridine adsorption is strongly affected by the crystallographic orientation of the electrode surface and that the extent of deviation from ideal capacitive behaviour is mainly of interfacial origin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and alternative method for the spectrophotometric determination of chromium(III) based on the formation of chromium(III)/azide complexes was established by investigating a new band in the ultraviolet region. The best experimental conditions for the analytical determination of this metallic ion were: ligand and perchloric acid analytical concentration = 493 and 12.0 mmol L-1, respectively; aqueous medium; T = 25.0 ºC; contact time = 1 hour. The maximum molar absorptivity coefficient occurred at 287 nm (average 1.481 ± 0.008 ´ 10(4) L mol-1 cm-1), leading to the determination of metal ion concentrations one hundred times lower than the ones formerly determined in the visible region. The system obeys Beer's Law and is suitable for chromium determination in the 0.702-2.81 mg L-1 concentration range (15-65% T, 1.00 cm-width quartz cells). Analytical applications of the current method were tested with a nutritional supplement containing chromium. Results were compared with those obtained with atomic absorption spectrometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stability constant (log beta) and thermodynamic parameters of Cd2+ complexes with sulfonamide and cephapirin were determined by Polarographic technique at pH = 7.30 ± 0.01 and µ = 1.0 M KNO3 at 250°C. The sulfonamides were sulfadiazine, sulfisoxazole, sulfamethaxazole, sulfamethazine, sulfathiazole, sulfacetamide and sulfanilamide used as primary ligands and cephapirin as secondary ligand. Cd2+ formed 1:1:1, 1:2:1 and 1:1:2 complexes. The nature of electrode processes were reversible and diffusion controlled. The stability constants and thermodynamic parameters (deltaG, deltaH and deltaS) were determined. The formation of the metal complexes has been found to be spontaneous, exothermic in nature, and entropically unfavourable at higher temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A quantitative analysis is made on the correlation ship of thermodynamic property, i.e., standard enthalpy of formation (ΔH fº) with Kier's molecular connectivity index(¹Xv),vander waal's volume (Vw) electrotopological state index (E) and refractotopological state index (R) in gaseous state of alkanes. The regression analysis reveals a significant linear correlation of standard enthalpy of formation (ΔH fº) with ¹Xv, Vw, E and R. The equations obtained by regression analysis may be used to estimate standard enthalpy of formation (ΔH fº) of alkanes in gaseous state.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combination of two low-cost classical procedures based on titrimetric techniques is presented for the determination of pyridoxine hydrochloride in pharmaceuticals samples. Initially some experiments were carried out aiming to determine both pKa1 and pKa2 values, being those compared to values of literature and theoretical procedures. Commercial samples containing pyridoxine hydrochloride were electrochemically analysed by exploiting their acid-base and precipitation reactions. Potentiometric titrations accomplished the reaction between the ionizable hydrogens present in pyridoxine hydrochloride, being NaOH used as titrant; while the conductimetric method was based on the chemical precipitation between the chloride of pyridoxine hydrochloride molecule and Ag+ ions from de silver nitrate, changing the conductivity of the solution. Both methods were applied to the same commercial samples leading to concordant results when compared by statistical tests (95 and 98% confidence levels). Recoveries ranging from 99.0 to 108.1% were observed, showing no significant interference on the results.