128 resultados para Sensitivity and specificity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rickettsia Anaplasma marginale is considered the main agent of bovine anaplasmosis. Due the nonspecific clinical signs of the anaplasmosis, the diagnosis of infection depends of laboratory confirmation. In recent years, molecular diagnostic methods have been used to detect A. marginale in cattle. However, the existence of a large number of assays of different sensitivity and cost makes the choice of an appropriate test difficult. In the present study, a real-time Polymerase Chain Reaction (PCR) based on the msp5 target gene was quantitatively assessed and compared to an end point PCR. Both reactions were subjected to sensitivity and specificity evaluation using plasmid DNA and samples from cattle experimentally infected with A. marginale. A comparative field trial of the tests was carried out using samples of cattle from a stable enzootic area for A. marginale. The real-time PCR showed a higher sensitivity than the end point PCR. This reaction (i.e. real-time PCR) was able to detect one copy of the msp5 gene in 100 ηg of plasmidial DNA, and more than 80% of its results were positive among experimentally infected animals seven days after infection. In addition, based on in silico analysis, the real-time PCR evaluated in the present study appears to be useful for the detection of A. ovis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: This study aimed to evaluate the efficacy of detection of anti-Aspergillus fumigatus antibodies in captive penguins by double radial agar gel immunodiffusion (AGID) for the aspergillosis diagnosis. We included 134 Magellanic penguins (Spheniscus magellanicus) in rehabilitation at the Center for Recovery of Marine Animals (CRAM / FURG). All of them were monitored by AGID weekly until its final destination (death or release), totalizing 660 serum samples studied. All animals were clinically accompanied and post-mortem examinations was performed in penguins that died during the studied period. A total of 28% (37/134) of the penguins died, 89.2% (33/37) due to aspergillosis, 11% (4/37) by other causes and 97 were released. From the 33 animals with proven aspergillosis, 21 presented anti- A. fumigatus antibodies by AGID, being the average interval between death and positive AGID 16.4 days. Twelve animals with negative serology died of aspergillosis. The sensitivity and specificity rates were 63.6% and 95% respectively, and the positive and negative predictive values were 80.7% and 88.9% respectively. These data demonstrate that the serological monitoring for detection of antibodies by AGID can be an important tool for the diagnosis of aspergillosis in penguins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated the accuracy of a 2nd generation ELISA to detect Helicobacter pylori infection in adults from a developing country in view of variations in sensitivity and specificity reported for different populations. We studied 97 non-consecutive patients who underwent endoscopy for evaluation of dispeptic symptoms. The presence of H. pylori was determined in antral biopsy specimens by culture, by the preformed urease test and in carbolfuchsin-stained smears. Patients were considered to be H. pylori positive if at least two of the three tests presented a positive result or if the culture was positive, and negative if the three tests were negative. Sixty-five adults (31 with peptic ulcer) were H. pylori positive and 32 adults were H. pylori negative. Antibodies were detected by Cobas Core anti-H. pylori EIA in 62 of 65 H. pylori-positive adults and in none of the negative adults. The sensitivity, specificity and positive and negative predictive values of the test were 95.4, 100, 100 and 91.4%, respectively. The Cobas Core anti-H. pylori EIA presented high sensitivity and specificity when employed for a population in Brazil, permitting the use of the test both to confirm the clinical diagnosis and to perform epidemiologic surveys.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to compare the sensitivity and specificity of V3 enzyme immunoassay (solid phase EIA and EIA inhibition) and restriction fragment length polymorphism (RFLP) with the DNA sequencing "gold standard" to identify the Brazilian HIV-1 variants of subtype B and B"-GWGR. Peripheral blood mononuclear cells were collected from 61 HIV-1-infected individuals attending a clinic in São Paulo. Proviral DNA was amplified and sequentially cleaved with the Fok I restriction enzyme. Plasma samples were submitted to a V3-loop biotinylated synthetic peptide EIA. Direct partial DNA sequencing of the env gene was performed on all samples. Based on EIA results, the sensitivity for detecting B-GPGR was 70%, compared to 64% for the Brazilian variant B"-GWGR while, the specificity of B-GPGR detection was 85%, compared to 88% for GWGR. The assessment of RFLP revealed 68% sensitivity and 94% specificity for the B-GPGR strain compared to 84 and 90% for the B"-GWGR variant. Moreover, direct DNA sequencing was able to detect different base sequences corresponding to amino acid sequences at the tip of the V3 loop in 22 patients. These results show a similar performance of V3 serology and RLFP in identifying the Brazilian variant GWGR. However, V3 peptide serology may give indeterminate results. Therefore, we suggest that V3 serology be used instead of DNA sequencing where resources are limited. Samples giving indeterminate results by V3 peptide serology should be analyzed by direct DNA sequencing to distinguish between B-GPGR and the Brazilian variant B"-GWGR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present cross-sectional, population-based study was designed to evaluate the performance of the FEV1/FEV6 ratio for the detection of airway-obstructed subjects compared to the FEV1/FVC <0.70 fixed ratio test, as well as the lower limit of normality (LLN) for 1000 subjects ³40 years of age in the metropolitan area of São Paulo, SP, Brazil. After the exclusion of 37 (3.7%) spirometries, a total of 963 pre-bronchodilator (BD) and 918 post-BD curves were constructed. The majority of the post-BD curves (93.1%) were of very good quality and achieved grade A (762 curves) or B (93 curves). The FEV1/FEV6 and FEV1/FVC ratios were highly correlated (r² = 0.92, P < 0.000). Two receiver operator characteristic curves were constructed in order to express the imbalance between the sensitivity and specificity of the FEV1/FEV6 ratio compared to two FEV1/FVC cut-off points for airway obstruction: equal to 70 (area under the curve = 0.98, P < 0.0001) and the LLN (area under the curve = 0.97, P < 0.0001), in the post-BD curves. According to an FEV1/FVC <0.70, the cut-off point for the FEV1/FEV6 ratio with the highest sum for sensitivity and specificity was 0.75. The FEV1/FEV6 ratio can be considered to be a good alternative to the FEV1/FVC ratio for the diagnosis of airway obstruction, both using a fixed cut-off point or below the LLN as reference. The FEV1/FEV6 ratio has the additional advantage of being an easier maneuver for the subjects and for the lung function technicians, providing a higher reproducibility than traditional spirometry maneuvers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our objective was to determine whether anthropometric measurements of the midarm (MA) could identify subjects with whole body fat-free mass (FFM) depletion. Fifty-five patients (31% females; age: 64.6 ± 9.3 years) with mild/very severe chronic obstructive pulmonary disease (COPD), 18 smokers without COPD (39% females; age: 49.0 ± 7.3 years) and 23 never smoked controls (57% females; age: 48.2 ± 9.6 years) were evaluated. Spirometry, muscle strength and MA circumference were measured. MA muscle area was estimated by anthropometry and MA cross-sectional area by computerized tomography (CT) scan. Bioelectrical impedance was used as the reference method for FFM. MA circumference and MA muscle area correlated with FFM and biceps and triceps strength. Receiver operating characteristic curve analysis showed that MA circumference and MA muscle area cut-off points presented sensitivity and specificity >82% to discriminate FFM-depleted subjects. CT scan measurements did not provide improved sensitivity or specificity. For all groups, there was no significant statistical difference between MA muscle area [35.2 (29.3-45.0) cm²] and MA cross-sectional area values [36.4 (28.5-43.3) cm²] and the linear correlation coefficient between tests was r = 0.77 (P < 0.001). However, Bland-Altman plots revealed wide 95% limits of agreement (-14.7 to 15.0 cm²) between anthropometric and CT scan measurements. Anthropometric MA measurements may provide useful information for identifying subjects with whole body FFM depletion. This is a low-cost technique and can be used in a wider patient population to identify those likely to benefit from a complete body composition evaluation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Milkborne transmission of Shiga toxin- producing Escherichia coli (STEC) has raised considerable concern due to recent outbreaks worldwide and poses a threat to public health. The aim of this study was to develop a sensitive and specific multiplex PCR assay to detect the presence of STEC in bovine raw milk. To identify E. coli (ATCC 25922) contamination, the gene uspA was used, and PCR sensitivity and specificity were accessed by testing diluted samples ranging from 2 to 2.0 × 10(6) CFU/mL. To detect STEC, the stx1 and stx2 genes were selected as targets. After reaction standardization, the multiplex assay was tested in raw milk collected from 101 cows on dairy farms. PCR assay for E. coli detection had a specificity of 100% and sensitivity of 79% (P<0.0001), with a lower detection limit of 2 CFU/mL. Multiplex PCR assay had 100% sensitivity for E. coli positive raw milk samples, and 31.1% were contaminated with STEC, 28.3% of stx2, and 1.9% of stx1. The multiplex PCR assay described in the present study can be employed to identify and screen E. coli harboring stx1 and stx2 genes in raw milk on dairy farms and in industries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PCR-based technique for GMO detection is the most reliable choice because of its high sensitivity and specificity. As a candidate of the European Union, Turkey must comply with the rules for launching into the market, traceability, and labeling of GMOs as established by EU legislation. Therefore, the objective of this study is to assess soybean products in the Turkish market to verify compliance with legislation using qualitative Polymerase Chain Reaction (PCR) assay to detect the presence of GM soybean and to quantify its amount of GM soybean in the samples tested positive using real-time PCR. DNA extracted by the modified CTAB method was properly used for PCR amplification of food materials. The amplification of a 118 bp DNA fragment of the lectin gene from soybean by PCR was successfully achieved in all samples. The GMO screening was based on the detection of 35S promoter and NOS terminator sequences. The GM positive samples were subjected to detection of Roundup ReadyTM soybean (RR) using quantitative real-time PCR. It was found that 100% of the tested food samples contained less than 0.1 per cent of EPSPS gene.