391 resultados para Laboratory diagnosis
Resumo:
Scorpion stings in Brazil are important not only because of their incidence but also for their potential ability to induce severe, and often fatal, clinical situations, especially among children. In this report we present the clinical and laboratory data of 4 patients victims of scorpion stings by T. serrulatus, who developed heart failure and pulmonary edema, with 3 of them dying within 24 hours of the sting. Anatomopathologic study of these patients revealed diffuse areas of myocardiocytolysis in addition to pulmonary edema. The surviving child presented enzymatic, electrocardiographic and echocardiographic changes compatible with severe cardiac involvement, which were reversed within 5 days. These findings reinforce the need for continuous monitoring of patients with severe scorpion envenoming during the hours immediately following the sting.
Resumo:
In Brazil, more than 500,000 new cases of malaria were notified in 1992. Plasmodium falciparum and P.vivax are the responsible species for 99.3% of the cases. For adequate treatment, precoce diagnosis is necessary. In this work, we present the results of the traditional Plasmodia detection method, thick blood film (TBF), and the results of alternative methods: Immunofluorescence assay (IFA) with polyclonal antibody and Quantitative Buffy Coat method (QBC)® in a well defined population groups. The analysis were done in relation to the presence or absence of malaria clinical symptoms. Also different classes of immunoglobulins anti-P.falciparum were quantified for the global analysis of the results, mainly in the discrepant results. We concluded that alternative methods are more sensitive than TBF and that the association of epidemiological, clinical and laboratory findings is necessary to define the presence of malaria.
Resumo:
Hydatid disease in tropical areas poses a serious diagnostic problem due to the high frequence of cross-reactivity with other endemic helminthic infections. The enzyme-linked-immunosorbent assay (ELISA) and the double diffusion arc 5 showed respectively a sensitivity of 73% and 57% and a specificity of 84-95% and 100%. However, the specificity of ELISA was greatly increased by using ovine serum and phosphorylcholine in the diluent buffer. The hydatic antigen obtained from ovine cyst fluid showed three main protein bands of 64,58 and 30 KDa using SDS PAGE and immunoblotting. Sera from patients with onchocerciasis, cysticercosis, toxocariasis and Strongyloides infection cross-reacted with the 64 and 58 KDa bands by immunoblotting. However, none of the analyzed sera recognized the 30 KDa band, that seems to be specific in this assay. The immunoblotting showed a sensitivity of 80% and a specificity of 100% when used to recognize the 30 KDa band.
Resumo:
The 4-year study (1987-1990) covered the major clinical-epidemiological characteristics of pneumonia in children as diagnosed at the emergency service of the Children's Hospital, as well as etiologies, and factors involved in the most severe cases. Etiology was determined in 47.7% of the 541 pneumonia cases, involving 283 pathogens of which 38.6% were viruses and 12.6% bacteria. Viral and mixed etiologies were more frequent in children under 12 months of age. Bacteria predominated in ages between 6 and 23 months. Among the viruses, respiratory syncytial virus predominated (66%). The bacterial pneumonias accounted for 12.2% of the recognized etiologies. The most important bacterial agents were S. pneumoniae (64%) and H. influenzae (19%). H. influenzae and mixed infections had a relevant participation during the 1988 season, pointing to annual variations in the relative participation of pathogens and its possible implication in severity of diseases. Correlation of severity and increased percentage of etiological diagnosis was assessed: patients with respiratory rates over 70 rpm, or pleural effusion and/or extensive pulmonary parenchyma compromise yielded higher positive laboratory results. Various individual and family risk factors were recognized when comparing pneumonia children with healthy controls.
Resumo:
In order to improve the diagnosis of human leptospirosis, we standardized the dot-ELISA for the search of specific IgM antibodies in saliva. Saliva and serum samples were collected simultaneously from 20 patients with the icterohemorrhagic form of the disease, from 10 patients with other pathologies and from 5 negative controls. Leptospires of serovars icterohaemorrhagiae, canicola, hebdomadis, brasiliensis and cynopteri grown in EMJH medium and mixed together in equal volumes, were used as antigen at individual protein concentration of 0.2 µg/µl. In the solid phase of the test we used polyester fabric impregnated with N-methylolacrylamide resin. The antigen volume for each test was 1µl, the saliva volume was 8 µl, and the volume of peroxidase-labelled anti-human IgM conjugate was 30 µl. A visual reading was taken after development in freshly prepared chromogen solution. In contrast to the classic nitrocellulose membrane support, the fabric support is easy to obtain and to handle. Saliva can be collected directly onto the support, a fact that facilitates the method and reduces the expenses and risks related to blood processing.
Resumo:
A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.
Resumo:
A Dot enzyme-linked immunosorbent assay (Dot-ELISA) was standardized and evaluated for the serodiagnosis of human toxoplasmosis. Out of 538 serum samples tested by the immunofluorescence test for toxoplasmosis (IFAT-IgG) as reference test, 183 (34%) were positive at cut off 1:16 and 192 (36%) were positive for Dot-ELISA-IgG at cut-off 1:256. For Dot-ELISA, co-positivity was 0.94, co-negativity 0.94 and concordance 0.88 in relation to IFAT-IgG. These results suggest the usefulness of Dot-ELISA (cut-off titer of 1:256) for the serodiagnosis of human toxoplasmosis. The main advantage of this technique is simplicity, positive test can be visually identified (colored precipitate). It does not require a special equipment and it can be used as a qualitative test to screen large numbers of samples or as a quantitative assay to determine end-point titration of individual sera.
Resumo:
An immunoprecipitation technique, ELIEDA (enzyme-linked-immuno-electro-diffusion assay), was evaluated for the diagnosis of Schistosoma mansoni infection with low worm burden. One hundred of serum samples from patients excreting less than 600 eggs per gram of feces (epg), with unrelated diseases and clinically healthy subjects were studied. In patients with egg counts higher than 200 epg, the sensitivities of IgM and IgG ELIEDA were 1.000 and 0.923, respectively, not differing from other Serologic techniques, such as indirect hemaglutination (IHAT), immunofluorescence (IFT) tests and immuno-electrodiffusion assay (IEDA). However in patients with low egg counts (< 100 epg), the IgG ELIEDA provided better results (0.821) than IgM ELIEDA (0.679), showing sensitivity that did not differ from that of IgG IFT (0.929), but lower than that of IgM IFT (0.964). However, its sensivity was higher than that found with IHAT (0.607) and IEDA (0.536). The specificity of IgG ELIEDA was comparable to that of other techniques. The data indicate that IgG ELIEDA might be useful for the diagnosis of slight S. mansoni infections, and the cellulose acetate membrane strips can be stored for further retrospective studies.
Resumo:
In order to evaluate the role of the determination of adenosine deaminase activity (ADA) in ascitic fluid for the diagnosis of tuberculosis, 44 patients were studied. Based on biochemical, cytological, histopathological and microbiological tests, the patients were divided into 5 groups: G1 - tuberculous ascites (n = 8); G2 - malignant ascites (n = 13); G3 - spontaneous bacterial peritonitis (n = 6); G4 - pancreatic ascites (n = 2); G5 - miscelaneous ascites (n = 15). ADA concentration were significantly higher in G1 (133.50 ± 24.74 U/l) compared to the other groups (G2 = 41.85 ± 52.07 U/l; G3 = 10.63 ± 5.87 U/l; G4 = 18.00 ± 7.07 U/l; G5 = 11.23 ± 7.66 U/l). At a cut-off value of >31 U/l, the sensitivity, specificity and positive and negative preditive values were 100%, 92%, 72% and 100%, respectively. ADA concentrations as high as in tuberculous ascites were only found in two malignant ascites caused by lymphoma. We conclude that ADA determination in ascitic fluid is a useful and reliable screening test for diagnosing tuberculous ascites. Values of ADA higher than 31 U/l indicate more invasive methods to confirm the diagnosis of tuberculosis.
Resumo:
In the absence of heart failure or cardiogenic shock, cardiac involvement diagnosis in icteric leptospirosis is possible on the basis of abnormal electrocardiograms. As metabolic and electrolytic disorders are frequently seen during acute leptospirosis infection, they may be responsible for some electrocardiograms changes. We conducted a study to assess if creatine phosphokinase isoenzyme determinations are useful in selecting patients with a high cardiac involvement suspicion. Sixty-nine patients were studied prospectively. Ten patients out of 16 with cardiac involvement and 25 without had high CK-MB levels (p>0.05), although mean values of abnormal CK-MB levels were higher in the group with cardiac involvement (p<0.05). Our analysis indicates that serum CK-MB determination does not provide a specific indicator of myocardial involvement in the course of icteric leptospirosis.
Resumo:
Amebiasis continues to be of epidemiological importance in underdeveloped countries. Clinical diagnosis and epidemiological setting in a region are based on the fecal microscopic identification of cysts or trophozoites. This procedure requires well trained personnel, is laborious, of low sensitivity and frequently yields false-positives results. The present study was designed to develop an immuno-enzymatic fecal 96 kDa antigen capture test (COPROELISA-Eh) more sensitive and specific than microscopic diagnosis of amebiasis. Triplicates of 177 stool samples processed by the formol-ether concentration method, were defined as positive or negative by three experienced microscopic observers. Another aliquot was submitted to the antigen capture test by a monoclonal antibody against a specific membrane antigen of pathogenic strains of Entamoeba histolytica. Optical densities were interpreted as positive when they exceeded the mean value of negative samples plus two standard deviations. COPROELISA-Eh showed a 94.4% sensitivity, 98.3% specificity, 96.2% positive predictive value and 97.6% negative predictive value for the detection of E. histolytica in feces. COPROELISA-Eh is more sensitive and specific than microscopic examination, does not require specially trained personnel and allows the simultaneous processing of a large number of samples.
Resumo:
Colonization of the colon and rectum by intestinal spirochetes is detected for the first time in Brazil in 4 of 282 (1.41%) patients who had undergone sigmoidoscopy and/or colonoscopy with a histopathological diagnosis of chronic non specific-colitis. This frequency is probably understimated, since surgically obtained specimens were not considered in the present study. Histopathological diagnosis was performed using routine stains like hematoxylin-eosin which showed the typical, of 3-µm thick hematoxyphilic fringe on the brush border of the surface epithelium, and by silver stains like the Warthin-Starry stain. Immunohistochemical procedures using two, polyclonal, primary antibodies, one against Treponema pallidum and the other against Leptospira interrogans serovar copenhageni serogroup Icterohaemorrhagiae cross-reacted with spirochetal antigen/s producing a marked contrast of the fringe over the colonic epithelium, preserving the spiral-shaped morphology of the parasite. In one case with marked diarrhea, immunohistochemistry detected spirochetal antigen/s within a cell in an intestinal crypt, thus demonstrating that the infection can be more widely disseminated than suspected using routine stains. Immunohistochemical procedures, thus, greatly facilitate the histological diagnosis of intestinal spirochetosis and may contribute to a better understanding of the pathogenesis of the disease. Transmission and scanning electron microscopy performed in one case showed that the spirochete closely resembled the species designated as Brachyspira aalborgi.