300 resultados para Detecção pseudo-heteródina


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and efficient method for the analysis of histamine in wines using HPLC with fluorescence detection after derivatization was developed and validated. The method LOD and LOQ values were 0.25 and 0.50 mg L-1 respectively. The repeatability and intermediary precision for the instrument and for the method presented RSD values of 3.7 and 2.9%, and 6.0 and 5.6%, respectively. The recoveries were 95.5 and 89.9% for the fortification levels of 2 and 10 mg L-1. The method was applied to determine the histamine content in Cabernet Sauvignon wines, which presented values between 1.2 and 5.7 mg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NMR is a valuable screening tool for the binding of ligands to proteins providing structural information on both protein and ligands and is thus largely applied to drug-discovery. Among the recent NMR techniques to probe weak binding protein-ligand complexes we have critically evaluated the advantages and disadvantages of STD (Saturation Transfer Difference), WaterLOGSY (Water Ligand Observation with Gradient Spectroscopy), NOE pumping and DOSY-NOESY (Diffusion-Ordered NOESY) using a mixture of BSA (bovine serum albumin) plus salicylic acid, caffeine, citric acid, adipic acid and D-glucose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The difference between the actual ECN 42 triacylglyceride content in vegetable oils, obtained by HPLC analysis, and the theoretical value calculated from the fatty acid composition was applied to detect the addition of seed oils with high contents of linoleic acid to olive oils commercialized in Brazil. The results indicate that samples analyzed were probably adulterated with low commercial value seed oils, rich in linoleic acid, like soybean, sunflower or corn.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study assessed heavy metal concentrations in the tissue samples of Corbiculafluminea, by ICP-OES. In the tissues, average levels of 23.99 µg/g of Cu, 144.21 µg/g of Zn, 0.71 µg/g of Cd, 7.10 µg/g of Cr and 2.41 µg/g of Pb were detected ahowing that this last value is high and above the ANVISA reference (2.00 µg/g) for fish and other products. The results suggest that natural processes occuring in the Ribeira de Iguape River are not sufficient for purification so that metals remain in the water and can accumulate in the trophic chain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detection of anionic species is a field which is currently attracting increasing interest. Research is carried out not only to gain a better understanding of biological events that anions participate in, but also to ascertain the potential contribution of the anionic chemosensors to the qualitative and quantitative analysis of species of interest in the areas of industry, medicine, the environment, and chemistry. This review summarizes several aspects related to the main strategies used in anion sensing. Each strategy discussed is illustrated with its potential applications citing recent examples. The prospects for their use in several areas are also described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development and validation of simple and selective analytical method for determination of 3.4-methylenedioxymethamphetamine (MDMA) in Ecstasy tablets, using high performance liquid chromatography with fluorescence detection. Analysis was performed in a reversed phase column (LiChrospher 100 C18, 150 x 4.6 mm, 5 µm), isocratic elution with phosphate buffer 25 mmol/L pH 3.0 and acetonitrile (95:5, v/v). The method presents adequate linearity, selectivity, precision and accuracy. MDMA concentration in analyzed tablets showed a remarkable variability (from 8.5 to 59.5 mg/tablet) although the tablet weights were uniform, indicating poor manufacturing control thus imposing additional health risks to the users.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis at microenvironments, like single cells or in minute volumes (nL), is an area of great interest for analytical and biological sciences. Measurements at these experimental conditions demand analytical tools (microelectrodes) capable of monitoring with rapid response, good resolution and minimal perturbation of the system. The major drawbacks in producing these microscopic electrodes have been largely overcome, principally due to the development of new fabrication methods. In this review, these procedures are described with emphasis to those devoted to the construction of microelectrodes for application in microenvironments. Examples of our efforts to use these devices as effective electrochemical sensors are also addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical chemical sensors with detection in the near and mid infrared region are reviewed. Fundamental concepts of infrared spectroscopy and optical chemical sensors are briefly described, before presenting some aspects on optical chemical sensors, such as synthesis of NIR and IR reagents, preparation of new materials as well as application in determinations of species of biological, industrial and environmental importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxocarbons ions are cyclic compounds presenting unusual electronic and vibrational properties. These molecules anions possess a high symmetry and degree of electronic delocalization, characteristics that have been discussed in several structural and spectroscopic investigations. Compounds in which one or more of the carbonyl oxygen atoms are replaced by other atoms or groups are called pseudo-oxocarbons. Compounds formed by substitution of the carbonyl groups by nitrogen groups former a new class named squaraines. Specificity the dicyanomethylene groups are interesting because of the possibility of further extension of the electronic delocalization and a new coordination site. These molecules also present interesting coordination properties which make these systems potentially useful in crystal engineering research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of the Fenton's reagent process has been investigated for the remediation of a Brazilian soil contaminated by diesel. Laboratory experiments were conducted in batch experiments. Slurries, consisting of 10 g of diesel-contaminated soil and 30 mL of Fenton's Reagent (0.41 mol L-1 H(2)0(2) and 0.18 mol L-1 FeSO4). The experiments were monitored during 24, 48 and 72 h. The efficiency of the Fenton treatment was dependent on the time of contact between soil and Fenton's reagents and matrix characteristics, probably iron content. Data suggested that no iron addition is needed for the application of Fenton-like treatment for the remediation of diesel-contaminated iron rich soils after 72 h reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the development of a home-made capillary electrophoresis (CE) system based on the capacitively coupled contactless conductivity detection (C4D) for the separation of the metallic species Zn2+, Cr3+, Pb2+, Cd2+, Co2+, Cu2+, Ni2+ e Tl+. A background electrolyte composed of MES/Histidine 0,02 mol L-1 (pH 5.0) was optimized for the separation of the metallic species by using organic solvents and complexing agents as additives. The system allowed the determination of the metallic species using MES/Histidine 0,02 mol L-1 and methanol 5% (pH 5.0) as a background electrolyte, 15 kV separation voltage and hydrodynamic injection by gravity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of chloramphenicol residues in goat milk can cause toxic effects in the population. The present work consists of the optimization and validation of analytical methodology for determination of chloramphenicol residues in goat milk by GC/ECD. The extraction was made with ethyl acetate and the clean-up with SPE-C18. The identification was made by comparison of retention time and GC/MS, and the quantification by external standard. The method was selective, linearity (0.998), precise (5.8-13.4%), exact (69.87-73.71%) and robust. The LOD and LOQ of method were 0.030 and 0.10 μg/kg, respectively. The method was efficiently for analysis of chloramphenicol in goat milk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method based on high-performance liquid chromatography with electrochemical detection has been developed and applied to the determination of Solvent blue 14 (SA-14) and Solvent red 24 (SV-24) in fuel samples. The dyes were better separated on C18 column, using a mobile phase composed of acetonitrile and ammonium acetate (90:10, v/v). Detection was carried out at an oxidation potential of +0.85V. The detector response was linear at concentration range of 7.50×10-8 - 1.50×10-6 mol L-1 (r = 0.997) for SA-14 and SV-24, respectively. The method was used to quantify these dyes in fuels samples with satisfactory accuracy and precision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple ultra-performance liquid chromatographic method for the simultaneous determination of sildenafil citrate and tadalafil was developed and validated. Sample preparation was dissolution in methanol, followed by centrifugation and dilution (1:10) with methanol. Analysis was performed in an Acquity® UPLC system with Acquity® BEH C18 column (2.1 x 50 mm, with 1.7 μm particles). The elution was isocratic with phosphate buffer pH 2.3 and acetonitrile (65:35, v/v) at a flow rate of 0.7 mL/min. The method presented adequate specificity, linearity, precision and accuracy and allowed the determination of the drugs in seized forensic samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We optimized a method for the determination of three main folate isoforms in leafy vegetables. Analysis was carried out by HPLC, using gradient of elution and fluorescence detection. Limits of quantification were 2 ng/mL; 2 ng/mL and 28 ng/mL for tetrahydrofolate (THF), 5-methyltetrahydrofolate (5-MTHF) and 5-formyltetrahydrofolate (5-FTHF), respectively. Recovery rates of THF, 5-MTHF and 5-FTHF varied from 87.86 to 100.64%; 88.12-94.22% and 89.82-106.69%, respectively. Test of repeatability showed relative standard deviation for peak areas lower than 10%. Tests for linearity showed high coefficients of determination. The results showed advances in folates extraction and analysis in raw and cooked leafy vegetables.