165 resultados para Capture ELISA
Resumo:
Phlebotomine sand flies are often captured with human bait and/or light traps, either with or without an animal bait. More recently, synthetic attractants have been used as bait in traps to improve the capture of phlebotomine sand flies as well as other insects of medical and veterinary importance. The aim of the present study was to evaluate the effects of the kairomone 1-octen-3-ol (octenol) and the synthetic human odor BG-Mesh LureTM (BGML - lactic acid, caproic acid and ammonia) baited in modified CDC light traps on the capture of phlebotomine sand flies. The experiments followed the 5x5 Latin square design. Among the species caught, Lutzomyia intermedia apparently presented a dose-dependent response to octenol. The response obtained with the BGML, alone or in combination with octenol (5 mg/h), indicated some degree of attractiveness of these baits to different phlebotomine sand fly species. Octenol seems to be more attractive to L. intermedia than to Lutzomyia longipalpis, while the BGML presented a higher success in capturing L. longipalpis. When the components of the BGML were used separately, there was no increase in catching the female of L. intermedia. Apparently, there was no synergistic effect between the octenol and the BGML. In conclusion, the octenol and the BGML were demonstrated to be possible baits to attract some phlebotomine sand fly species.
Resumo:
In this report, the efficiency of Adultrap under field conditions is compared to a CDC backpack aspirator and to MosquiTRAP. An urban dengue-endemic area of Rio de Janeiro was selected to evaluate the efficiency of mosquito traps in capturing Aedes aegypti females. Adultrap and aspirator captured similar numbers of Ae. aegypti females, with the former showing high specificity to gravid individuals (93.6%). A subsequent mark-release-recapture experiment was conducted to evaluate Adultrap and MosquiTRAP efficiency concomitantly. With a 6.34% recapture rate, MosquiTRAP captured a higher mean number of female Ae. aegypti per trap than Adultrap (Ç2 = 14.26; df = 1; p < 0,05). However, some MosquiTRAPs (28.12%) contained immature Ae. aegypti after 18 days of exposure in the field and could be pointed as an oviposition site for female mosquitoes. Both trapping methods, designed to collect gravid Ae. aegypti females, seem to be efficient, reliable and may aid routine Ae. aegypti surveillance.
Resumo:
Significant advances were made in the diagnosis of filariasis in the 1990s with the emergence of three new alternative tools: ultrasound and tests to detect circulating antigen using two monoclonal antibodies, Og4C3 and AD12-ICT-card. This study aimed to identify which of these methods is the most sensitive for diagnosis of infection. A total of 256 individuals, all male and carrying microfilariae (1-15,679 MF/mL), diagnosed by nocturnal venous blood samples, were tested by all three techniques. The tests for circulating filarial antigen concurred 100% and correctly identified 246/256 (96.69%) of the positive individuals, while ultrasound detected only 186/256 (73.44%). Of the circulating antigen tests, ICT-card was the most convenient method for identification of Wuchereria bancrofti carriers. It was easy to perform, practical and quick.
Resumo:
Toxoplasma gondii causes posterior uveitis and the specific diagnosis is based on clinical criteria. The presence of anti-T. gondii secretory IgA (sIgA) antibodies in patients' tears has been reported and an association was found between ocular toxoplasmosis and the anti-T. gondii sIgA isotype in Brazilian patients. The purpose of this study was to provide an objective validation of the published ELISA test for determining the presence of anti-T. gondii sIgA in the tears of individuals with ocular toxoplasmosis. Tears from 156 patients with active posterior uveitis were analysed; 82 of them presented characteristics of ocular toxoplasmosis (standard lesion) and 74 patients presented uveitis due to other aetiologies. Cases of active posterior uveitis were considered standard when a new inflammatory focus satellite to old retinochoroidal scars was observed. The determination of anti-T. gondii sIgA was made using an ELISA test with crude tachyzoite antigenic extracts. Tears were collected without previous stimulation. Detection of sIgA showed 65.9% sensitivity (95% CI = 54.5-74.4), 71.6% specificity (95% CI = 59.8-81.2), a positive predictive value of 72% (95% CI = 60.3-81.5) and a negative predictive value of 65.4% (95% CI = 54.0-75.4). sIgA reactivity was higher in the tears of patients with active posterior uveitis due to T. gondii (p < 0.05). The test is useful for differentiating active posterior uveitis due to toxoplasmosis from uveitis caused by other diseases.
Resumo:
We assessed the risk classification of dengue fever based on the capture of Aedes aegypti adults using MosquiTRAP, a type of sticky trap, in comparison with traditional larval infestation indices. A total of 27 MosquiTRAPs were installed, with one trap per block, and were inspected weekly between November 2008-February 2009. Infestation baseline data were obtained from a survey conducted prior to trap installation. The index generated by MosquiTRAP and house index (HI) classified the area "in alert situation". The set for risk of dengue occurrence proposed by the use of MosquiTRAP classify areas in the same way of the traditional HI.
Resumo:
The levels of total of IgG, IgG1, IgG2, IgG3 and IgG4 were evaluated in 54 patients with chronic paracoccidioidomycosis (PCM) before, during and after treatment using an enzyme-linked immunosorbent assay with Mexo and recombinant Pb27 (rPb27) as the antigens. Mexo was effective in distinguishing PCM patients from individuals in the negative control group (NC) based on total IgG and rPb27 performed worse than Mexo when these two groups were compared. IgG1, IgG2, IgG3 and IgG4 could not be used to clearly distinguish PCM patients from those in the NC group using either antigen. There was no clear relationship between antibody levels and the period of treatment. The majority of patients presented with decreased antibody levels during treatment, with no statistically significant differences among the different periods of treatment. Only IgG4 presented a negative correlation between its levels and clinical improvement during treatment. In total, 65% of untreated PCM patients showed reactivity against IgG4 when the Mexo antigen was used and this reactivity decreased over the course of treatment. There was a tendency towards decreasing antibody levels during treatment, but these antibody levels did not necessarily clear after the treatment was stopped. Mexo was useful for PCM diagnosis using total IgG; however, more studies are necessary before this antigen can be used in measuring the levels of total IgG and its subclasses for monitoring patients during treatment.
Resumo:
The aim of this work was to evaluate a dot-enzyme-linked immunosorbent assay (dot-ELISA) using excretory-secretory antigens from the larval stages of Toxocara canis for the diagnosis of toxocariasis. A secondary aim was to establish the optimal conditions for its use in an area with a high prevalence of human T. canis infection. The dot-ELISA test was standardised using different concentrations of the antigen fixed on nitrocellulose paper strips and increasing dilutions of the serum and conjugate. Both the dot-ELISA and standard ELISA methods were tested in parallel with the same batch of sera from controls and from individuals living in the problem area. The best results were obtained with 1.33 µg/mL of antigen, dilutions of 1/80 for the samples and controls and a dilution of 1/5,000 for the anti-human IgG-peroxidase conjugate. All steps of the procedure were performed at room temperature. The coincidence between ELISA and dot-ELISA was 85% and the kappa index was 0.72. The dot-ELISA test described here is rapid, easy to perform and does not require expensive equipment. Thus, this test is suitable for the serological diagnosis of human T. canis infection in field surveys and in the primary health care centres of endemic regions.
Resumo:
The detection of anti-hepatitis A virus (HAV) antibody levels by diagnostic kits in the convalescent period of disease generally use immunoglobulin G (IgG), which is expensive. An alternative to IgG is immunoglobulin Y (IgY), an immunoglobulin antibody encountered in birds and reptiles. The aim of this study was to develop a competitive immunoenzymatic assay to measure total anti-HAV antibody levels using anti-HAV IgY as the capture and conjugated immunoglobulins. For this purpose, anti-HAV IgY was conjugated to horseradish peroxidase (HRP) and the optimal dilution of HRP-conjugated antibodies was evaluated to establish the competitive immuneenzymatic assay. The results obtained from our "in-house" assay were plotted on a receiver operator curve, which showed a sensitivity of 95% and a specificity of 98.8%, demonstrating that a competitive anti-HAV IgY immunoenzymatic assay developed "in house" could be used as an alternative to commercial assays that utilise IgG.
Resumo:
ELISA in situ can be used to titrate hepatitis A virus (HAV) particles and real-time polymerase chain reaction (RT-PCR) has been shown to be a fast method to quantify the HAV genome. Precise quantification of viral concentration is necessary to distinguish between infectious and non-infectious particles. The purpose of this study was to compare cell culture and RT-PCR quantification results and determine whether HAV genome quantification can be correlated with infectivity. For this purpose, three stocks of undiluted, five-fold diluted and 10-fold diluted HAV were prepared to inoculate cells in a 96-well plate. Monolayers were then incubated for seven, 10 and 14 days and the correlation between the ELISA in situ and RT-PCR results was evaluated. At 10 days post-incubation, the highest viral load was observed in all stocks of HAV via RT-PCR (10(5) copies/mL) (p = 0.0002), while ELISA revealed the highest quantity of particles after 14 days (optical density = 0.24, p < 0.001). At seven days post-infection, there was a significant statistical correlation between the results of the two methods, indicating equivalents titres of particles and HAV genome during this period of infection. The results reported here indicate that the duration of growth of HAV in cell culture must be taken into account to correlate genome quantification with infectivity.
Resumo:
Although the human-landing catch (HLC) method is the most effective for collecting anthropophilic anophelines, it has been increasingly abandoned, primarily for ethical considerations. The objective of the present study was to develop a new trap for the collection of Anopheles darlingi . The initial trials were conducted using the BG-Sentinel trap as a standard for further trap development based on colour, airflow direction and illumination. The performance of the trap was then compared with those of the CDC, Fay-Prince, counterflow geometry trap (CFG) and HLC. All trials were conducted outdoors between 06:00 pm-08:00 pm. Female specimens of An. darlingi were dissected to determine their parity. A total of 8,334 anophelines were captured, of which 4,945 were identified as An. darlingi . The best trap configuration was an all-white version, with an upward airflow and no required light source. This configuration was subsequently named BG-Malaria (BGM). The BGM captured significantly more anophelines than any of the other traps tested and was similar to HLC with respect to the number and parity of anophelines. The BGM trap can be used as an alternative to HLC for collecting anophelines.
Resumo:
In several countries, surveillance of insect vectors is accomplished with automatic traps. This study addressed the performance of Mosquito Magnet® Independence (MMI) in comparison with those of CDC with CO2 and lactic acid (CDC-A) and CDC light trap (CDC-LT). The collection sites were in a rural region located in a fragment of secondary tropical Atlantic rainforest, southeastern Brazil. Limatus durhami and Limatus flavisetosus were the dominant species in the MMI, whereas Ochlerotatus scapularis was most abundant in CDC-A. Culex ribeirensis and Culex sacchettae were dominant species in the CDC-LT. Comparisons among traps were based on diversity indices. Results from the diversity analyses showed that the MMI captured a higher abundance of mosquitoes and that the species richness estimated with it was higher than with CDC-LT. Contrasting, difference between MMI and CDC-A was not statistically significant. Consequently, the latter trap seems to be both an alternative for the MMI and complementary to it for ecological studies and entomological surveillance.
Resumo:
In a recent issue of Memórias do Instituto Oswaldo Cruz, published in Rio de Janeiro in February 2014 (109: 87-92), Adami et al. have published a survey reporting Mansonella parasite prevalence in the Amazon Region. This report makes a useful contribution to the existing knowledge of filarial parasite distribution within the Amazon area, parasite prevalence rates in relation to age and occupation and provides observations on the possible clinical impact of Mansonella ozzardi. Their publication also provides an account of what appears to be a novel ELISA that has recently been used in the Simuliidae and Onchocerciasis Laboratory of the Oswaldo Cruz Institute, Rio de Janeiro, Brazil. We are concerned that the publication of this ELISA may have created an excessively positive impression of the effectiveness of the onchocerciasis recrudescence serological surveillance tools that are presently available for use in the Amazonia onchocerciasis focus. In this letter we have, thus, sought to highlight some of the limitations of this ELISA and suggest how continuing insecurities concerning the detection of antibodies to Onchocerca volvulus within the Amazonia onchocerciasis focus might be minimised.
Resumo:
Orchid bees are increasingly applied on Neotropical biomonitoring and bioindication studies due to the relative easiness of sampling and identification when compared to other bee groups. A considerable number of orchid bee community studies have been adopting baited traps as a sampling method, especially for replication purposes. However, the trap attributes are variable, and hitherto no evaluation of different designs was carried out. Here, five attributes of baited traps were tested: trap volume, number of entrance holes, presence of landing platform, kind of landing platform, and fixation content. We use Mann-Whitney tests to access differences in richness and abundance capture rates for each trap design. We found that volume, number of entrance holes, and fixation content do not influence orchid bees capture. However, the design without landing platforms had a significantly higher capture rate for richness when compared with sanded landing platforms. On the other hand, analyzing the kind of landing platform, we detected a significantly higher richness and abundance for the trap with landing platforms glued with sand. Despite the fact that the effects of different designs tested here were very punctual, we consider that results from samples taken with different baited trap designs are comparable. Some adjustments on trap design can be done according to the particularities of future studies.
Resumo:
The objective of this work was to evaluate the use of a low-cost trap to capture Cerambycidae in different seasons in planted forests in Brazil. Thirty polyethylene-terephthalate trap bottles per hectare were used, disposed at every 50 m. The traps were red painted and contained glass flasks with a mixture of ethanol, methanol and benzaldehyde. There were soap and water at the trap bottom. The traps were checked biweekly for beetle presence. Sampling time required one minute per sample, and traps were easy to use. Total sampling cost, including materials and labor, was US$ 13.46 per sample. Six Cerambycidae species were captured along the dry and rainy seasons.
Resumo:
The objective of this work was to evaluate the field attractiveness of Thyanta perditor synthetic sex pheromone-baited traps, its attractivity to other stink bug species, and the response of T. perditor to a geometric isomer of the sex pheromone. Two-liter transparent plastic bottles traps were baited with rubber septa impregnated with the treatments: 1 mg of methyl-(2E,4Z,6Z)-decatrienoate [(2E,4Z,6Z)-10:COOMe], the male sex pheromone of T. perditor; 1 mg of (2E,4Z,6Z)-10:COOMe protected from sunlight in standard PVC plumbing pipe; 1 mg of its geometric isomer [(2E,4E,6Z)-10:COOMe]; and traps with rubber septa impregnated with hexane (control). The experiment was carried out in field during the soybean reproductive stages. Traps were monitored weekly, and the captures were compared to the population density estimated by the sampling cloth and visual inspection monitoring techniques. Traps baited with the sex pheromone, protected or not, were more effective in capturing T. perditor than traps baited with the isomer or the hexane. Thyanta perditor sex pheromone showed cross-attraction to other stink bug species, such as Euschistus heros, Edessa meditabunda, Piezodorus guildinii and Nezara viridula. Pheromone-baited traps can be used in population monitoring and to identify the relative composition of stink bug guilds.