146 resultados para Analytical validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to develop and validate simple, accurate and precise spectroscopic methods (multicomponent, dual wavelength and simultaneous equations) for the simultaneous estimation and dissolution testing of ofloxacin and ornidazole tablet dosage forms. The medium of dissolution used was 900 ml of 0.01N HCl, using a paddle apparatus at a stirring rate of 50 rpm. The drug release was evaluated by developed and validated spectroscopic methods. Ofloxacin and ornidazole showed 293.4 and 319.6nm as λmax in 0.01N HCl. The methods were validated to meet requirements for a global regulatory filing. The validation included linearity, precision and accuracy. In addition, recovery studies and dissolution studies of three different tablets were compared and the results obtained show no significant difference among products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combination of two low-cost classical procedures based on titrimetric techniques is presented for the determination of pyridoxine hydrochloride in pharmaceuticals samples. Initially some experiments were carried out aiming to determine both pKa1 and pKa2 values, being those compared to values of literature and theoretical procedures. Commercial samples containing pyridoxine hydrochloride were electrochemically analysed by exploiting their acid-base and precipitation reactions. Potentiometric titrations accomplished the reaction between the ionizable hydrogens present in pyridoxine hydrochloride, being NaOH used as titrant; while the conductimetric method was based on the chemical precipitation between the chloride of pyridoxine hydrochloride molecule and Ag+ ions from de silver nitrate, changing the conductivity of the solution. Both methods were applied to the same commercial samples leading to concordant results when compared by statistical tests (95 and 98% confidence levels). Recoveries ranging from 99.0 to 108.1% were observed, showing no significant interference on the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most warning systems for plant disease control are based on Vinho, in Bento Gonçalves - RS, during the growing seasons 2000/ weather models dependent on the relationships between leaf wetness 01, 2002/03 and 2003/2004, using the grape cultivar Isabel. The duration and mean air temperature in this period considering the conventional system used by local growers was compared with the target disease intensity. For the development of a warning system to new warning system by using different cumulative daily disease severity control grapevine downy mildew, the equation generated by Lalancette values (CDDSV) as the criterion to schedule fungicide application and et al. (7) was used. This equation was employed to elaborate a critical reapplication. In experiments conducted in 2003/04, CDDSV of 12 - period table and program a computerized device, which records, though 14 showed promising to schedule the first spraying and the interval electronic sensors, leaf wetness duration, mean temperature in this between fungicide applications, reducing by 37.5% the number of period and automatically calculates the daily value of probability of applications and maintaining the same control efficiency in leaves infection occurrence. The system was validated at Embrapa Uva e and bunches, similarly to the conventional system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scarcity of long-term series of sediment-related variables has led watershed managers to apply mathematical models to simulate sediment fluxes. Due to the high efforts for installation and maintenance of sedimentological gauges, tracers have been pointed out as an alternative to validate soil redistribution modelling. In this study, the 137Cs technique was used to assess the WASA-SED model performance at the Benguê watershed (933 km²), in the Brazilian semiarid. Qualitatively, good agreement was found among the 137Cs technique and the WASA-SED model results. Nonetheless, quantitatively great differences, up to two orders of magnitude, were found between the two methods. Among the uncertainties inherent to the 137Cs technique, definition of the reference inventory seems to be a major source of imprecision. In addition, estimations of water and sediment fluxes with mathematical models usually also present high uncertainty, contributing to the quantitative differences of the soil redistribution estimates with the two methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiation balance is the fraction of incident solar radiation upon earth surface which is available to be used in several natural processes, such as biological metabolism, water loss by vegetated surfaces, variation of temperature in farming systems and organic decomposition. The present study aimed to assess and validate the performance of two estimation models for Rn in Ponta Grossa city, Paraná State, Brazil. To this end, during the period of 04/01/2008 to 04/30/2011, from radiometric data collected by an automatic weather station set at the Experimental Station, of the State University of Ponta Grossa. We performed a linear regression study by confrontation between measurements made through radiometric balance and Rn estimates obtained from Brunt classical method, and the proposed method. Both models showed excellent performance and were confirmed by the statistical parameters applied. However, the alternative method has the advantage of requiring only global solar radiation values, temperature, and relative humidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To develop and validate an instrument for measuring the acquisition of technical skills in conducting operations of increasing difficulty for use in General Surgery Residency (GSR) programs. Methods: we built a surgical skills assessment tool containing 11 operations in increasing levels of difficulty. For instrument validation we used the face validaity method. Through an electronic survey tool (Survey MonKey(r)) we sent a questionnaire to Full and Emeritus members of the Brazilian College of Surgeons - CBC - all bearers of the CBC Specialist Title. Results: Of the 307 questionnaires sent we received 100 responses. For the analysis of the data collected we used the Cronbach's alpha test. We observed that, in general, the overall alpha presented with values near or greater than 0.70, meaning good consistency to assess their points of interest. Conclusion: The evaluation instrument built was validated and can be used as a method of assessment of technical skill acquisition in the General Surgery Residency programs in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work is to describe the design and the implementation of an experiment to study the dynamics and the active control of a slewing multi-link flexible structure. The experimental apparatus was designed to be representative of a flexible space structure such as a satellite with multiple flexible appendages. In this study we describe the design procedures, the analog and digital instrumentation, the analytical modeling together with model validation studies carried out through experimental modal testing and parametric system identification studies in the frequency domain. Preliminary results of a simple positional control where the sensor and the actuator are positioned physically at the same point is also described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In two-phase miniature and microchannel flows, the meniscus shape must be considered due to effects that are affected by condensation and/or evaporation and coupled with the transport phenomena in the thin film on the microchannel wall, when capillary forces drive the working fluid. This investigation presents an analytical model for microchannel condensers with a porous boundary, where capillary forces pump the fluid. Methanol was selected as the working fluid. Very low liquid Reynolds numbers were obtained (Re~6), but very high Nusselt numbers (Nu~150) could be found due to the channel size (1.5 mm) and the presence of the porous boundary. The meniscus calculation provided consistent results for the vapor interface temperature and pressure, as well as the meniscus curvature. The obtained results show that microchannel condensers with a porous boundary can be used for heat dissipation with reduced heat transfer area and very high heat dissipation capabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the problems that slows the development of off-line programming is the low static and dynamic positioning accuracy of robots. Robot calibration improves the positioning accuracy and can also be used as a diagnostic tool in robot production and maintenance. A large number of robot measurement systems are now available commercially. Yet, there is a dearth of systems that are portable, accurate and low cost. In this work a measurement system that can fill this gap in local calibration is presented. The measurement system consists of a single CCD camera mounted on the robot tool flange with a wide angle lens, and uses space resection models to measure the end-effector pose relative to a world coordinate system, considering radial distortions. Scale factors and image center are obtained with innovative techniques, making use of a multiview approach. The target plate consists of a grid of white dots impressed on a black photographic paper, and mounted on the sides of a 90-degree angle plate. Results show that the achieved average accuracy varies from 0.2mm to 0.4mm, at distances from the target from 600mm to 1000mm respectively, with different camera orientations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to optimize and validate the solid-liquid extraction (ESL) technique for determination of picloram residues in soil samples. At the optimization stage, the optimal conditions for extraction of soil samples were determined using univariate analysis. Ratio soil/solution extraction, type and time of agitation, ionic strength and pH of extraction solution were evaluated. Based on the optimized parameters, the following method of extraction and analysis of picloram was developed: weigh 2.00 g of soil dried and sieved through a sieve mesh of 2.0 mm pore, add 20.0 mL of KCl concentration of 0.5 mol L-1, shake the bottle in the vortex for 10 seconds to form suspension and adjust to pH 7.00, with alkaline KOH 0.1 mol L-1. Homogenate the system in a shaker system for 60 minutes and then let it stand for 10 minutes. The bottles are centrifuged for 10 minutes at 3,500 rpm. After the settlement of the soil particles and cleaning of the supernatant extract, an aliquot is withdrawn and analyzed by high performance liquid chromatography. The optimized method was validated by determining the selectivity, linearity, detection and quantification limits, precision and accuracy. The ESL methodology was efficient for analysis of residues of the pesticides studied, with percentages of recovery above 90%. The limits of detection and quantification were 20.0 and 66.0 mg kg-1 soil for the PVA, and 40.0 and 132.0 mg kg-1 soil for the VLA. The coefficients of variation (CV) were equal to 2.32 and 2.69 for PVA and TH soils, respectively. The methodology resulted in low organic solvent consumption and cleaner extracts, as well as no purification steps for chromatographic analysis were required. The parameters evaluated in the validation process indicated that the ESL methodology is efficient for the extraction of picloram residues in soils, with low limits of detection and quantification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to validate the transit-time technique for long-term measurements of iliac and renal blood flow in rats. Flow measured with ultrasonic probes was confirmed ex vivo using excised arteries perfused at varying flow rates. An implanted 1-mm probe reproduced with accuracy different patterns of flow relative to pressure in freely moving rats and accurately quantitated the resting iliac flow value (on average 10.43 ± 0.99 ml/min or 2.78 ± 0.3 ml min-1 100 g body weight-1). The measurements were stable over an experimental period of one week but were affected by probe size (resting flows were underestimated by 57% with a 2-mm probe when compared with a 1-mm probe) and by anesthesia (in the same rats, iliac flow was reduced by 50-60% when compared to the conscious state). Instantaneous changes of iliac and renal flow during exercise and recovery were accurately measured by the transit-time technique. Iliac flow increased instantaneously at the beginning of mild exercise (from 12.03 ± 1.06 to 25.55 ± 3.89 ml/min at 15 s) and showed a smaller increase when exercise intensity increased further, reaching a plateau of 38.43 ± 1.92 ml/min at the 4th min of moderate exercise intensity. In contrast, exercise-induced reduction of renal flow was smaller and slower, with 18% and 25% decreases at mild and moderate exercise intensities. Our data indicate that transit-time flowmetry is a reliable method for long-term and continuous measurements of regional blood flow at rest and can be used to quantitate the dynamic flow changes that characterize exercise and recovery

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to translate the Roland-Morris (RM) questionnaire into Brazilian-Portuguese and adapt and validate it. First 3 English teachers independently translated the original questionnaire into Brazilian-Portuguese and a consensus version was generated. Later, 3 other translators, blind to the original questionnaire, performed a back translation. This version was then compared with the original English questionnaire. Discrepancies were discussed and solved by a panel of 3 rheumatologists and the final Brazilian version was established (Brazil-RM). This version was then pretested on 30 chronic low back pain patients consecutively selected from the spine disorders outpatient clinic. In addition to the traditional clinical outcome measures, the Brazil-RM, a 6-point pain scale (from no pain to unbearable pain), and its numerical pain rating scale (PS) (0 to 5) and a visual analog scale (VAS) (0 to 10) were administered twice by one interviewer (1 week apart) and once by one independent interviewer. Spearman's correlation coefficient (SCC) and intraclass correlation coefficient (ICC) were computed to assess test-retest and interobserver reliability. Cross-sectional construct validity was evaluated using the SCC. In the pretesting session, all questions were well understood by the patients. The mean time of questionnaire administration was 4 min and 53 s. The SCC and ICC were 0.88 (P<0.01) and 0.94, respectively, for the test-retest reliability and 0.86 (P<0.01) and 0.95, respectively, for interobserver reliability. The correlation coefficient was 0.80 (P<0.01) between the PS and Brazil-RM score and 0.79 (P<0.01) between the VAS and Brazil-RM score. We conclude that the Brazil-RM was successfully translated and adapted for application to Brazilian patients, with satisfactory reliability and cross-sectional construct validity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The phonological loop is a component of the working memory system specifically involved in the processing and manipulation of limited amounts of information of a sound-based phonological nature. Phonological memory can be assessed by the Children's Test of Nonword Repetition (CNRep) in English speakers but not in Portuguese speakers due to phonotactic differences between the two languages. The objectives of the present study were: 1) to develop the Brazilian Children's Test of Pseudoword Repetition (BCPR), a Portuguese version of the CNRep, and 2) to validate the BCPR by correlation with the Auditory Digit Span Test from the Stanford-Binet Intelligence Scale. The BCPR and Digit Span were assessed in 182 children aged 4-10 years, 84 from Minas Gerais State (42 from a rural region) and 98 from the city of São Paulo. There are subject age and word length effects causing repetition accuracy to decline as a function of the number of syllables of the pseudowords. Correlations between BCPR and Digit Span forward (r = 0.50; P <= 0.01) and backward (r = 0.43; P <= 0.01) were found, and partial correlation indicated that higher BCPR scores were associated with higher Digit Span scores. BCPR appears to depend more on schooling, while Digit Span was more related to development. The results demonstrate that the BCPR is a reliable measure of phonological working memory, similar to the CNRep.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to translate the Kidney Disease Quality of Life - Short Form (KDQOL-SF™1.3) questionnaire into Portuguese to adapt it culturally and validate it for the Brazilian population. The KDQOL-SF was translated into Portuguese and back-translated twice into English. Patient difficulties in understanding the questionnaire were evaluated by a panel of experts and solved. Measurement properties such as reliability and validity were determined by applying the questionnaire to 94 end-stage renal disease patients on chronic dialysis. The Nottingham Health Profile Questionnaire, the Karnofsky Performance Scale and the Kidney Disease Questionnaire were administered to test validity. Some activities included in the original instrument were considered to be incompatible with the activities usually performed by the Brazilian population and were replaced. The mean scores for the 19 components of the KDQOL-SF questionnaire in Portuguese ranged from 22 to 91. The components "Social support" and "Dialysis staff encouragement" had the highest scores (86.7 and 90.8, respectively). The test-retest reliability and the inter-observer reliability of the instrument were evaluated by the intraclass correlation coefficient. The coefficients for both reliability tests were statistically significant for all scales of the KDQOL-SF (P < 0.001), ranging from 0.492 to 0.936 for test-retest reliability and from 0.337 to 0.994 for inter-observer reliability. The Cronbach's alpha coefficient was higher than 0.80 for most of components. The Portuguese version of the KDQOL-SF questionnaire proved to be valid and reliable for the evaluation of quality of life of Brazilian patients with end-stage renal disease on chronic dialysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to investigate the psychometric properties and cross-cultural validity of the Beck Depression Inventory (BDI) among ethnic Chinese living in the city of São Paulo, Brazil. The study was conducted on 208 community individuals. Reliability and discriminant analysis were used to test the psychometric properties and validity of the BDI. Principal component analysis was performed to assess the BDI's factor structure for the total sample and by gender. The mean BDI score was lower (6.74, SD = 5.98) than observed in Western counterparts and showed no gender difference, good internal consistency (Cronbach's alpha 0.82), and high discrimination of depressive symptoms (75-100%). Factor analysis extracted two factors for the total sample and each gender: cognitive-affective dimension and somatic dimension. We conclude that depressive symptoms can be reliably assessed by the BDI in the Brazilian Chinese population, with a validity comparable to that for international studies. Indeed, cultural and measurement biases might have influenced the response of Chinese subjects.