203 resultados para tablet formulations


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to discuss some selected applications of square wave voltammetry published in the last five years. The applications focused here cover several electroanalytical fields such as: determination of pesticides; molecules with biological activity; metals and other environmental pollutants. Special attention is given to the work developed in the Grupo de Materiais Eletroquímicos e Métodos Eletroanalíticos - IQSC - USP concerning the utilization of square wave voltammetry, with different kinds of electrodes, for the determination of pesticides in natural waters and active principles in pharmaceutical formulations. The new methodology is simple, fast and sensitive when compared with the traditional ones such as chromatography and spectrophotometry. The satisfactory results obtained provide alternative procedures for the quality control of drugs and the monitoring of pesticides in natural environments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) or octogen is a white crystalline substance which occurs in four polymorphous forms. It is used in a wide variety of military and industrial formulations owing to its suitable properties. Researchers have demonstrated the usefulness of this energetic material in explosive components. In the present work we apply differential scanning calorimetry (DSC) to measure the a ® d solid-solid phase transition energy of HMX. The results obtained by Kissinger's and Ozawa's methods were 487 and 495 kJ/mol, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new computer program has been developed to help the users of force methods for magnetic moment determination. It provides a user-friendly interface for the calculation of corrected magnetic susceptibilities of paramagnetic materials and enables the user to simulate a number of chemical formulations for the sample under study. The program is written in the Perl scripting language and runs on a Unix platform.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coffee is a product consumed all around the world, Brazil being the biggest exporter. However, little is known about the difference in composition of the different brands in terms of bioactive substances. In the present study, ten of the most consumed brands of coffee in Rio de Janeiro were analyzed. Caffeine contents, trigonelline and total chlorogenic acid varied from 0.8 g/100g to 1.4 g/100g; 0.2 g/100g to 0.5 g/100g and from 3.5 g kg-1 to 15.9 g kg-1, respectively. The large heterogeneity observed in the amounts of the bioactive compounds can be attributed to different formulations of the various brands, as well as to different roasting conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple flow injection procedure was developed for determining dipyrone (1-phenyl-2,3-dimethyl-4-methylaminomethano-5-pyrazolone sodium, metamizol, analgin) in pharmaceutical formulations. The determination is based on the reduction of Ag+ ions to Ag0 by dipyrone. A colloidal suspension of Ag0 produced was transported by carrier solution (0.01 mol L-1 NaOH) and turbidimetrically detected at 425 nm. The analytical curve for dipyrone was linear in the range from 5.0 x 10-4 to 2.5 x 10-3 mol L-1 with a correlation coefficient of 0.9990. The detection limit was 1.3 x 10-4 mol L-1 (3sigmaB/slope). The relative standard deviation for ten successive measurements was 1.8% and an analytical frequency of 45 h-1 was obtained. The recovery values from three samples ranged from 96.0 to 102%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An indirect flow injection spectrophotometric procedure is proposed for the determination of N-acetyl-L-cysteine in pharmaceutical formulations. In this system, ferroin ([Fe(II)-(fen)2]2+) in excess, with a strong absorption at 500 nm, is oxidized by cerium(IV) yielding cerium(III) and [Fe(III)-(fen)2]3+ (colorless), thus producing a baseline. When N-acetyl-L-cysteine solution is introduced into the flow injection system, it reacts with cerium(IV) increasing the analytical signal in proportion to the drug concentration. Under optimal experimental conditions, the linearity of the analytical curve for N-acetyl-L-cysteine ranged from 6.5x10-6 to 1.3x10-4 mol L-1. The detection limit was 5.0x10-6 mol L-1and recoveries between 98.0 and 106% were obtained. The sampling frequency was 60 determinations per hour and the RSD was smaller than 1.4% for 2.2x10-5 mol L-1 N-acetyl-L-cysteine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A CPC (Compound Parabolic Concentrator) reactor was projected and constructed aiming to promote the degradation of the organic matter present in considerable volumes of aqueous effluents, under the action of solar radiation. The essays were done using a model effluent which consists of a mixture of fragments of a sodium salt of lignosulphonic acid possessing a mean molecular weigth of 52,000 Daltons, and a real effluent, from a chip board industry. The volume of effluent in each test was about 50 L. The tests involved heterogeneous (TiO2 P25 Degussa and formulations made from the association of TiO2 with a photosensitiser), and homogeneous (thermal and photochemical Fenton reactions) catalysis of the effluents. The results demonstrate the viability of application of this kind of reactor even when the load of organic pollutants is high.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of liquid chromatography-mass spectrometric (LC-MS) techniques in the last few decades has made possible the analysis of trace amounts of analytes from complex matrices. With LC, the analytes of interest can be separated from each other as well as from the interfering matrix, after which they can be reliably identified thanks to the sensitivity and specificity of MS. LC-MS has become an irreplaceable tool for many applications, ranging from the analysis of proteins or pharmaceuticals in biological fluids to the analysis of toxic substances in environmental samples. In different segments of Brazilian Industry mass spectrometry has an important role, e.g. in the pharmaceutical industry in the development of generic formulations, contributing to the growth of Industry and social inclusion. However, the Brazilian chemists until this moment don't have an effective role in this new segment of the analytical chemistry in Brazil. The present paper shows the actual scenario for mass spectrometry in the pharmaceutical industry, emphasizing the need of a revision of graduation courses to attend the needs of this growing market.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adsorptive stripping voltammetry carried out in a homogeneous ternary solvent composed of N,N-dimethylformamide, water and ethanol, with alpha-benzoinoxime (alphaBO) as the complexing agent for Mo(VI) and a 0.5 mol L-1 acetic acid - sodium acetate buffer as supporting electrolyte was successfully used for the determination of molybdenum in polyvitamin-polymineral tablets. Tablet samples were analyzed and the results were compared with those obtained both by graphite furnace atomic absorption and by recovery tests, with good correlations, indicating that this may be considered as an alternative procedure for routine determination of Mo(VI) in pharmaceutical samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The quality of the gasoline utilized for fueling internal combustion engines with spark ignition is directly affected by the gasoline's properties. Thus, the fuel's properties must be in perfect equilibrium to allow the engine to perform optimally, not only insofar as fuel consumption is concerned, but also in order to reduce the emission of pollutants. Vapor pressure and vaporization enthalpy are important properties of a gasoline determining the fuel's behavior under different operating conditions in internal combustion engines. The study reported here involved the development of a device to determine the vapor pressure and the vaporization enthalpy of formulations containing volumes of 5, 15 and 25% of ethanol in four base gasolines (G1, G2, G3 and G4). The chemical composition of these gasolines was determined using a gas chromatographer equipped with a flame ionization detector (FID).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

2,2',4,4',6,6'-hexanitrostilbene (HNS) is a very important high explosive that is used in a range of military, aerospace and industrial formulations owing to its suitable properties. It is an insensitive and thermaly stable explosive that can be produced from 2,4,6-trinitrotoluene (TNT). This paper shows the characterization of synthesized HNS by different techniques, such as elementary analysis, differential scanning calorimetry (DSC), thermogravimetric analysis (TG), Fourier transform infrared spectroscopy (FT-IR) and through the determination of the heat of combustion in a calorimeter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influences of the spray-drying parameters and the type of nanoparticles (nanocapsules or nanospheres) on the characteristics of nanoparticle-coated diclofenac-loaded microparticles were investigated by using a factorial design 3². Gastrointestinal tolerance following oral administration in rats was evaluated. Formulations were selected considering the best yields, the best encapsulation efficiencies and the lowest water contents, presenting surfaces completely coated by nanostructures and a decrease in the surface areas in relation to the uncoated core. In vitro drug release demonstrated the influence of the nanoparticle-coating on the dissolution profiles of diclofenac. Nanocapsule-coated microparticles presented a protective effect on the gastrointestinal mucosa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The environmental impact of detergents and other consumer products is behind the continued interest in the chemistry of the surfactants used. Of these, linear alkylbenzene sulfonates (LASs) are most widely employed in detergent formulations. The precursors to LASs are linear alkylbenzenes (LABs). There is also interest in the chemistry of these hydrocarbons, because they are usually present in commercial LASs (due to incomplete sulfonation), or form as one of their degradation products. Additionally, they may be employed as molecular tracers of domestic waste in the aquatic environment. The following aspects are covered in the present review: The chemistry of surfactants, in particular LAS; environmental impact of the production of LAS; environmental and toxicological effects of LAS; mechanisms of removal of LAS in the environment, and methods for monitoring LAS and LAB, the latter in domestic wastes. Classical and novel analytical methods employed for the determination of LAS and LAB are discussed in detail, and a brief comment on detergents in Brazil is given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection turbidimetric procedure exploiting merging zones is proposed for determining homatropine methylbromide (HMB) in pharmaceutical preparations. The determination is based on the precipitation reaction of homatropine methylbromide with AgNO3 solution to form a precipitate, which was measured at 410 nm. The analytical curve was linear in the HMB concentration range from 8.0x10-4 to 1.7x10-3 mol L-1, with a detection limit of 9.5x10-5 mol L-1. The recoveries ranged from 94.9 to 104 %, the sampling frequency was 75 h-1 and relative standard deviations were smaller than 2.0 % for solutions containing 1.2x10-3 and 1.5x10-3 mol L-1 HMB (n=10). The results obtained for commercial formulations using the FIA procedure were in good agreement with those obtained by using a comparative method (r= 0.9983).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple method was proposed for determination of paracetamol and ibuprofen in tablets, based on UV measurements and partial least squares. The procedure was performed at pH 10.5, in the concentration ranges 3.00-15.00 µg ml-1 (paracetamol) and 2.40-12.00 µg ml-1 (ibuprofen). The model was able to predict paracetamol and ibuprofen in synthetic mixtures with root mean squares errors of prediction of 0.12 and 0.17 µg ml-1, respectively. Figures of merit (sensitivity, limit of detection and precision) were also estimated. The results achieved for the determination of these drugs in pharmaceutical formulations were in agreement with label claims and verified by HPLC.