169 resultados para analytical parameters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Few articles deal with lead and strontium isotopic analysis of water samples. The aim of this study was to define the chemical procedures for Pb and Sr isotopic analyses of groundwater samples from an urban sedimentary aquifer. Thirty lead and fourteen strontium isotopic analyses were performed to test different analytical procedures. Pb and Sr isotopic ratios as well as Sr concentration did not vary using different chemical procedures. However, the Pb concentrations were very dependent on the different procedures. Therefore, the choice of the best analytical procedure was based on the Pb results, which indicated a higher reproducibility from samples that had been filtered and acidified before the evaporation, had their residues totally dissolved, and were purified by ion chromatography using the Biorad® column. Our results showed no changes in Pb ratios with the storage time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work the separation of the chiral anesthetic compounds ketamine and bupivacaine was development using two chiral stationary phases (CSP). Ketamine enantiomers were well separate in the polysaccharide-based CSP (microcrystalline cellulose triacetate - MCTA) while bupivacaine in the tartardiamide-based CSP (Kromasil CHI-TBB). In both cases, the effect of temperature was investigated under analytical conditions. An improvement in the separation performance with temperature was observed. Thermodynamic parameters were evaluated by the van't Hoff plot. We concluded that enthalpic effects controlled the retention in these chiral columns. The enantiomers of ketamine and bupivacaine were separated under overloaded conditions with a good performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a validation of an analytical procedure for the analysis of petroleum hydrocarbons in marine sediment samples. The proposed protocol is able to measure n-alkanes and polycyclic aromatic hydrocarbons (PAH) in samples at concentrations as low as 30 ng/g, with a precision better than 15% for most of analytes. The extraction efficiency of fortified sediments varied from 65.1 to 105.6% and 59.7 to 97.8%, for n-alkanes and PAH in the ranges: C16 - C32 and fluoranthene - benzo(a)pyrene, respectively. The analytical protocol was applied to determine petroleum hydrocarbons in sediments collected from a marine coastal zone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A binary sampling flow analysis system equipped with gas diffusion cell was developed for NH4+ and/or NH2Cl determination in wastewater and disinfection products samples based on the Berthelot reaction of the NH2Cl diffused through the semi-permeable PTFE membrane. The effect of the analytical conditions related to the reaction and flow parameters were evaluated and N-NH4+ and N-NH2Cl were determined in concentration ranges from 0.17 to 5 mg L-1 and from 0.5 to 14.5 mg L-1, respectively. Limits of detection (3σ) of 50 and 140 µg L-1 for N-NH4+ and N-NH2Cl were calculated, respectively, and RSD of 5 and 2% were calculated for 10 consecutive determinations of N-NH4+ (1 and 3 mg L-1) and N-NH2Cl (3 and 9 mg L-1), respectively with 30 determinations h-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validation of an analytical procedure must be certified through the determination of parameters known as figures of merit. For first order data, the acuracy, precision, robustness and bias is similar to the methods of univariate calibration. Linearity, sensitivity, signal to noise ratio, adjustment, selectivity and confidence intervals need different approaches, specific for multivariate data. Selectivity and signal to noise ratio are more critical and they only can be estimated by means of the calculation of the net analyte signal. In second order calibration, some differentes approaches are necessary due to data structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The establishment of quality standards for biodiesel was a key step to win the confidence of the market and the automotive industry, thus ensuring the success of the new fuel. In this review are presented standard methods and other analytical methods suggested for analysis of biodiesel. The methods of analysis were divided into groups according to information that may be provided on the contaminants from the raw material of the production process, the molecular structures of biodiesel and its degradation during storage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validation of analytical methods is an important step in quality control. The main objective of this study is to propose an HPLC experiment to verify the parameters of validation of chromatographic methods, based on green chemistry principles, which can be used in experimental courses of chemistry and related areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Energy Value (EV) corresponds to the sum of the energetic contributions from food macronutrients (proteins, carbohydrates and fats) and is required on the labels of pre-packaged foods. The determinations of these parameters are based on distinct analytical procedures, each one being time-consuming, laborious and producing residues. This work presents multivariate models to determine the EV contents of industrialized foods for human consumption by using X-ray fluorescence spectra of samples with known parameters, determined through conventional methods. The proposed method is an alternative to conventional analytical methods and does not require any reagent, given the demands of the "green chemistry".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method by liquid chromatography has been proposed and validated to study the apparent solubility of ibuprofen in biorelevant dissolution media. The main properties of the studied media were pH values of 5.0 and 6.5 and the presence or absence of some natural surfactant agents. The parameters evaluated were specificity, linearity, precision, accuracy, and detection and quantification limits, as well as the drug stability under the analysis conditions. The developed method was useful to determine the apparent solubility of this drug as a function of temperature and surfactants concentration to demonstrate the validity of the Biopharmaceutics Classification System.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the introduction of GC there has been an ongoing interest in reducing time of analysis resulting in new terms and definitions such as ultra fast gas chromatography (UF-GC). One of the most used definitions describes UF-GC as a technique that combines the employment of short narrow bore column with very fast temperature programming rates producing chromatographic peaks in the range of 50 ms and allowing separations times in 1-2 min or less. This paper summarizes the analytical approaches, the main parameters involved and the instrumentation towards UF-GC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is here discussed the development of a low cost analytical instrument with capacity for metals determination using atomic emission measurements in an electrothermal atomization system with a tungsten coil atomizer. The main goal was to show a new frontier for using this atomizer and to demonstrate that the simple instrumental arrangement here proposed has potential for portability and for solving analytical tasks related to metals determination. Atomic emission of calcium was selected for the adjustment of instrumental parameters and to evaluate the main characteristics of the lab-built instrument. Cobalt was determined in medicines and one alloy to demonstrate its feasibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the establishment of dissolution test conditions for 75 mg cinnarizine capsules using a multivariate approach. A 2³ full factorial design was carried out to achieve the best conditions and HCl 0.1 mol L-1 as dissolution medium, basket as apparatus at 100 rpm and collect time at 30 min were considered adequate. The quantification was carried out by spectrophotometry at 251 nm. Both dissolution procedure and analytical method were validated and all parameters were within the acceptable limits. Since there is no official monograph for this pharmaceutical product, this dissolution test could be applied for quality control routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tibolone is a synthetic steroid used for prevention of bone loss and treatment of menopause symptoms. This article describes the development and validation of an analytical method to quantify tibolone in capsules using high performance liquid chromatography with UV detection. After chromatography conditions are established the validation parameters evaluated were specificity, linearity, precision, accuracy, detection and quantification limits and robustness. The method developed is effective to analyze tibolone in capsules, being able to be used in quality control laboratory routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ursolic acid is a natural molecule that presents several pharmacological properties. In this work, an analytical method by RP-HPLC has been developed and validated for quantification of this drug in the solid dispersions, using PEG 6000 and Poloxamer 407 as polymers. The method was specific, linear in the range of 1.0-50.0 µg mL-1 (r<0.99), precise (CV < 5% for both inter- and intra-assays), accurate (maximum deviation of ± 13%), and robust to the parameters evaluated. This method has proved to be simple and useful for ursolic acid determination in solid dispersions, enabling its determination in pharmaceutical dosage form.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work consists of the development and validation of analytical method for evaluation of glycyrrhizic acid, salicylic acid, and caffeine in chitosan-alginate nanoparticles by high performance liquid chromatography. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The methods were applied to nanoparticles suspensions containing the drugs and were able to determine the entrapment efficiency successfully. The best entrapment efficiency was achieved with the glycyrrhizic acid (95.4%).