108 resultados para Vacuum-tubes.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In many engineering applications, compliant piping systems conveying liquids are subjected to inelastic deformations due to severe pressure surges such as plastic tubes in modern water supply transmission lines and metallic pipings in nuclear power plants. In these cases the design of such systems may require an adequate modeling of the interactions between the fluid dynamics and the inelastic structural pipe motions. The reliability of the prediction of fluid-pipe behavior depends mainly on the adequacy of the constitutive equations employed in the analysis. In this paper it is proposed a systematic and general approach to consistently incorporate different kinds of inelastic behaviors of the pipe material in a fluid-structure interaction analysis. The main feature of the constitutive equations considered in this work is that a very simple numerical technique can be used for solving the coupled equations describing the dynamics of the fluid and pipe wall. Numerical examples concerning the analysis of polyethylene and stainless steel pipe networks are presented to illustrate the versatility of the proposed approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work analyzes an active fuzzy logic control system in a Rijke type pulse combustor. During the system development, a study of the existing types of control for pulse combustion was carried out and a simulation model was implemented to be used with the package Matlab and Simulink. Blocks which were not available in the simulator library were developed. A fuzzy controller was developed and its membership functions and inference rules were established. The obtained simulation showed that fuzzy logic is viable in the control of combustion instabilities. The obtained results indicated that the control system responded to pulses in an efficient and desirable way. It was verified that the system needed approximately 0.2 s to increase the tube internal pressure from 30 to 90 mbar, with an assumed total delay of 2 ms. The effects of delay variation were studied. Convergence was always obtained and general performance was not affected by the delay. The controller sends a pressure signal in phase with the Rijke tube internal pressure signal, through the speakers, when an increase the oscillations pressure amplitude is desired. On the other hand, when a decrease of the tube internal pressure amplitude is desired, the controller sends a signal 180º out of phase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this work was to determine the coefficients of sorption and desorption of picloram in Ultisol (PVA) and Oxisol (LVA), displaying different physical and chemical characteristics. Samples of soil were collected at the 0 20 cm depth in degraded pasture areas in Viçosa-MG. Firstly, the equilibrium time between the herbicide in solution and the herbicide which was sorbed in the soil was determined by the Batch Equilibrium method. The time required was 24 hours. Sorption and desorption studies were carried out under controlled laboratory conditions; the sorption evaluation consisted in adding 10.0 mL of herbicide solutions at different concentrations to tubes containing 2.00 g of soil, with vertical rotary agitation being maintained during the pre-determined equilibrium time. After centrifugation, supernatant extract cleaning and filtration, herbicide concentration was determined by high performance liquid chromatography (HPLC) with UV detection at 254 nm. Desorption was evaluated using the samples in the tubes after the sorption tests. The Freundlich model was used for interpretation of the sorption process. Ultisol showed higher adsorption coefficient (Kf a) compared with Oxisol, which may be attributed to the lower pH of the soil and its higher organic matter content. Desorption process occurred in both soils; the LVA allowed greater release of the previously sorbed molecules.