156 resultados para SPRAY-DRYING TECHNIQUE
Resumo:
This study defined the main adjuvant characteristics that may influence or help to understand drift formation process in the agricultural spraying. It was evaluated 33 aqueous solutions from combinations of various adjuvants and concentrations. Then, drifting was quantified by means of wind tunnel; and variables such as percentage of droplets smaller than 50 μm (V50), 100 μm (V100), diameter of mean volume (DMV), droplet diameter composing 10% of the sprayed volume (DV0.1), viscosity, density and surface tension. Assays were performed in triplicate, using Teejet XR8003 flat fan nozzles at 200 kPa (medium size droplets). Spray solutions were stained with Brilliant Blue Dye at 0.6% (m/ v). DMV, V100, viscosity cause most influence on drift hazardous. Adjuvant characteristics and respective methods of evaluation have applicability in drift risk by agricultural spray adjuvants.
Resumo:
ABSTRACT Surfactant use in spray solutions has a major advantage of reducing droplet surface tension and increasing deposition. We aimed to evaluate droplet deposition on cattail plants (Typha subulata) using food coloring (Brilliant Blue - FD & C-1) as marker added to spray solution at two different growth stages: vegetative (4 leaves) and flowering (5 leaves). The treatments were arranged in a completely randomized design with four replications and five plants per plot (16.2-L tanks). Treatments consisted of adding into spray solutions Brilliant Blue alone (control), Brilliant Blue + 0.5% v/v Aterbane and Brilliant Blue + 0.01% v/v Silwet. Spraying was performed by a pressurized CO2 sprayer at 220 kPa using two Teejet XR 8002 nozzles at a spray volume of 200 L ha-1. We observed that surfactant addition provided uniform deposition of spray solution on T. subulata plants at both growth stages compared to treatments without surfactant. However, this product has not increased spray deposits on cattail leaves at both stages.
Resumo:
ABSTRACT This paper aimed at investigating the knowledge level of people working on pesticide spraying activities concerning spray adjuvant properties, as well as collecting information on disposal locations for residues from internal spray tank cleaning, and finally the understanding of pesticide spray drift occurrence in the state of Mato Grosso, Brazil. The information was gathered through a questionnaire answered by participants of a rural extension program in application technology located in nineteen grain and fiber producing regions of Mato Grosso state. Among the mentioned adjuvants, 49.0% belonged to the mineral oil class and 17.9% of participants did not know the functions performed by such products. In addition, 58.5% of the participants discarded residues into the field. Among the participants who answered the question about spray drift occurrence causes, 54.1% indicated problems relating to inadequate weather conditions. In conclusion, there is a lack of knowledge on adjuvant functions, besides of inappropriate residue disposal in the state of Mato Grosso. Spray drift was referred as a problem; however, most of participants were not able to discuss the causes of these losses.
Resumo:
OBJECTIVE: To standardize a technique for ventilating rat fetuses with Congenital Diaphragmatic Hernia (CDH) using a volume-controlled ventilator.METHODS: Pregnant rats were divided into the following groups: a) control (C); b) exposed to nitrofen with CDH (CDH); and c) exposed to nitrofen without CDH (N-). Fetuses of the three groups were randomly divided into the subgroups ventilated (V) and non-ventilated (N-V). Fetuses were collected on day 21.5 of gestation, weighed and ventilated for 30 minutes using a volume-controlled ventilator. Then the lungs were collected for histological study. We evaluated: body weight (BW), total lung weight (TLW), left lung weight (LLW), ratios TLW / BW and LLW / BW, morphological histology of the airways and causes of failures of ventilation.RESULTS: BW, TLW, LLW, TLW / BW and LLW / BW were higher in C compared with N- (p <0.05) and CDH (p <0.05), but no differences were found between the subgroups V and N-V (p> 0.05). The morphology of the pulmonary airways showed hypoplasia in groups N- and CDH, with no difference between V and N-V (p <0.05). The C and N- groups could be successfully ventilated using a tidal volume of 75 ìl, but the failure of ventilation in the CDH group decreased only when ventilated with 50 ìl.CONCLUSION: Volume ventilation is possible in rats with CDH for a short period and does not alter fetal or lung morphology.
Resumo:
The authors present the four-arm single docking full robotic surgery to treat low rectal cancer. The eight main operative steps are: 1- patient positioning; 2- trocars set-up and robot docking; 3- sigmoid colon, left colon and splenic flexure mobilization (lateral-to-medial approach); 4-Inferior mesenteric artery and vein ligation (medial-to-lateral approach); 5- total mesorectum excision and preservation of hypogastric and pelvic autonomic nerves (sacral dissection, lateral dissection, pelvic dissection); 6- division of the rectum using an endo roticulator stapler for the laparoscopic performance of a double-stapled coloanal anastomosis (type I tumor); 7- intersphincteric resection, extraction of the specimen through the anus and lateral-to-end hand sewn coloanal anastomosis (type II tumor); 8- cylindric abdominoperineal resection, with transabdominal section of the levator muscles (type IV tumor). The techniques employed were safe and have presented low rates of complication and no mortality.
Resumo:
The authors describe a surgical technique which allows, without increasing costs, to perform laparoscopic cholecystectomy with a single incision, without using specific materials and with better surgical ergonomics. The technique consists of a longitudinal umbilical incision, navel detachment, use of a permanent 10mm trocar and two clamps directly and bilaterally through the aponeurosis without the use of 5mm trocars, transcutaneous gallbladder repair with straight needle cotton suture, ligation with unabsorbable suture and umbilical incision for the specimen extraction. The presented technique enables the procedure with conventional and permanent materials, improving surgical ergonomics, with safety and aesthetic advantages.
Resumo:
Objective: To assess the application of aponeurotic sling by a modified technique with direct visualization of needles in patients with stress urinary incontinence. Methods: we applied the Kings Health Questionnaire (KHQ) for quality of life, gynecological examination, urinalysis I and urine culture approximately seven days prior to the urodynamic study (UDS) and the one-hour PAD test in patients undergoing making aponeurotic sling with its passing through the retropubic route with direct visualization of the needle, PAD test and King's Helth Questionnaire before and after surgery. Results: The mean age was 50.6 years, BMI of 28 and Leak Pressure (LP) 58,5cm H2O; 89% were Caucasian. Forty-six of them were monitored for three and six months, 43 for 12 months. The objective cure rate at 12 months postoperatively was approximately 93.5%. In evaluating quality of life, we observed a significant improvement in 12 months postoperatively compared with the preoperative period. There was no no urethral/bladder injury. As adverse results, we had one persistent urinary retention (2.3%), who was submitted to urethrolysis, currently without incontinence. Conclusion: The proposed procedure is safe as for the risk of bladder or urethral injuries, promoting significant improvement in quality of life and objective cure.
Resumo:
OBJETIVO: determinar a eficácia do spray de lidocaína a 10% aplicado no colo uterino antes da execução da histeroscopia diagnóstica para reduzir a dor e o desconforto causados pelo exame. MÉTODOS: Participaram do estudo 261 pacientes atendidas consecutivamente, entre março de 2004 e março de 2005. As pacientes foram randomizadas para dois grupos: um grupo recebendo aplicação tópica do spray de lidocaína (grupo lidocaína) e outro não recebendo nenhuma medicação antes do procedimento (grupo controle). Trinta miligramas de lidocaína spray a 10% foram aplicados na superfície do colo uterino, sendo a histeroscopia iniciada cinco minutos depois. Imediatamente após o final do procedimento a paciente respondeu um questionário sobre dor e quantificou a intensidade da dor, em centímetros, usando uma escala analógica visual não graduada. Os testes t não pareado, Mann-Whitney e chi2 foram aplicados na análise estatística, com nível de significância de 0,05. RESULTADOS: não houve diferença entre os grupos quanto à idade, paridade ou porcentagem de pacientes na menacme ou menopausa, ou quanto à indicação do procedimento e os achados histeroscópicos. Uma biópsia foi realizada em 57 das 132 pacientes no grupo lidocaína, e em 48 das 129 do grupo controle (p=0,96). O escore médio de dor foi 4,3±2,9 no grupo lidocaína, e 3,9±2,5 no grupo controle (p=0,2). Diferença no escore médio de dor foi observada somente na comparação entre pacientes na menacme e menopausa recebendo ou não a lidocaína spray, com p=0,01 e 0,04, respectivamente. CONCLUSÕES: o uso da lidocaína spray durante a histeroscopia diagnóstica não minimiza o desconforto e a dor das pacientes, e não deve ser utilizada.
Resumo:
The Shadow Moiré fringe patterns are level lines of equal depth generated by interference between a master grid and its shadow projected on the surface. In simplistic approach, the minimum error is about the order of the master grid pitch, that is, always larger than 0,1 mm, resulting in an experimental technique of low precision. The use of a phase shift increases the accuracy of the Shadow Moiré technique. The current work uses the phase shifting method to determine the surfaces three-dimensional shape using isothamic fringe patterns and digital image processing. The current study presents the method and applies it to images obtained by simulation for error evaluation, as well as to a buckled plate, obtaining excellent results. The method hands itself particularly useful to decrease the errors in the interpretation of the Moiré fringes that can adversely affect the calculations of displacements in pieces containing many concave and convex regions in relatively small areas.
Resumo:
The irrigation is a technique developed to supply the hydric needs of the plants. The use of the water should be optimized so that the culture just has enough for its growth, avoiding waste. The objective of this work was to characterize the behavior of capacitive sensors of humidity to monitor the moisture in the soils. In first instance, it was appraised sensors with dielectric built of synthetic pomes stone (Rd = 0,4 and Rd = 0,8) and of soil samples (Rd = 0,8 and Rd = 1,0), being the Rd parameter a geometric factor that relates the distance between the capacitor plates with radius of the plates. For the calibration, the sensors were installed in PVC recipient of cylindrical shape, filled with soil. The set (sensor and soil) was humidified by capillary effect and submitted by a natural drying very slowly. The parameter readings were taken daily, which allowed obtain the curves relating the humidity percentage, expressed in terms of dry weight, with the output voltage fort the sensor. The experiments were performed in sand soil and in dark red latossolo. The obtained results allowed to infer that the behavior of the sensor has a specific feature for each type of soil, being, therefore, necessary to develop a own calibration curve for the sensor, when used in soil with specific characteristic.
Resumo:
The formal calibration procedure of a phase fraction meter is based on registering the outputs resulting from imposed phase fractions at known flow regimes. This can be straightforwardly done in laboratory conditions, but is rarely the case in industrial conditions, and particularly for on-site applications. Thus, there is a clear need for less restrictive calibration methods regarding to the prior knowledge of the complete set of inlet conditions. A new procedure is proposed in this work for the on-site construction of the calibration curve from total flown mass values of the homogeneous dispersed phase. The solution is obtained by minimizing a convenient error functional, assembled with data from redundant tests to handle the intrinsic ill-conditioned nature of the problem. Numerical simulations performed for increasing error levels demonstrate that acceptable calibration curves can be reconstructed, even from total mass measured within a precision of up to 2%. Consequently, the method can readily be applied, especially in on-site calibration problems in which classical procedures fail due to the impossibility of having a strict control of all the input/output parameters.
Resumo:
The Amplified Fragment Length Polymorphism (AFLP) technique was used to access genetic diversity between three domestic and nine wild proso millet biotypes from the United States and Canada. Eight primer combinations detected 39 polymorphic DNA fragments, with the genetic distance estimates among biotypes ranging from 0.02 to 0.04. Colorado-Weld County black seeded and Wyoming-Platte County were the most distinct biotypes according to the dissimilarity level. A UPGMA cluster analysis revealed two distinct groups of proso millet without any geographic association. Six weed biotypes exhibiting some characters of cultivated plants were grouped together with domesticated biotypes of proso millet while the three typical wild phenotypes were clearly clustered into another group according to AFLP markers.
Resumo:
The action of herbicides that affect the integrity of cell membranes and cause leakage, like PPO-inhibitors, can be detected by measuring the electric conductivity (EC) of a solution in which the plant tissue target is incubated in the presence of herbicide. The objectives of this work were to confirm PPO resistance in a new Euphorbia heterophylla (EPHHL) biotype, and to compare the electrolyte leakage from R and S to PPO-inhibitors biotypes, using two different methods of incubation in a solution containing herbicides. One experiment was carried in greenhouse and three in laboratory, with a completely randomized design. In the greenhouse experiment, four biotypes of EPHHL were sprayed with seven rates of fomesafen to confirm resistance in suspected biotypes. Leaf disks from R and S EPHHL biotypes in the second and the third experiments and entire leaves in the fourth experiment were incubated in a solution containing PPO-inhibitors to subsequently determine EC of solution. The study confirmed the resistance to PPO-inhibitors in two EPHHL biotypes. There were no significant differences between S and R biotypes in the experiments with the incubation of leaf disks, but incubation of entire leaves of EPHHL S biotype showed higher EC when in a solution with fomesafen, in comparison to the R biotype. The results of this work are an indirect evidence that resistance to PPO-inhibitors is related to lower absorption of herbicide by the shoots and also to some kind of mechanism to cope with oxidative stress.
Resumo:
The objective of this study was to optimize and validate the solid-liquid extraction (ESL) technique for determination of picloram residues in soil samples. At the optimization stage, the optimal conditions for extraction of soil samples were determined using univariate analysis. Ratio soil/solution extraction, type and time of agitation, ionic strength and pH of extraction solution were evaluated. Based on the optimized parameters, the following method of extraction and analysis of picloram was developed: weigh 2.00 g of soil dried and sieved through a sieve mesh of 2.0 mm pore, add 20.0 mL of KCl concentration of 0.5 mol L-1, shake the bottle in the vortex for 10 seconds to form suspension and adjust to pH 7.00, with alkaline KOH 0.1 mol L-1. Homogenate the system in a shaker system for 60 minutes and then let it stand for 10 minutes. The bottles are centrifuged for 10 minutes at 3,500 rpm. After the settlement of the soil particles and cleaning of the supernatant extract, an aliquot is withdrawn and analyzed by high performance liquid chromatography. The optimized method was validated by determining the selectivity, linearity, detection and quantification limits, precision and accuracy. The ESL methodology was efficient for analysis of residues of the pesticides studied, with percentages of recovery above 90%. The limits of detection and quantification were 20.0 and 66.0 mg kg-1 soil for the PVA, and 40.0 and 132.0 mg kg-1 soil for the VLA. The coefficients of variation (CV) were equal to 2.32 and 2.69 for PVA and TH soils, respectively. The methodology resulted in low organic solvent consumption and cleaner extracts, as well as no purification steps for chromatographic analysis were required. The parameters evaluated in the validation process indicated that the ESL methodology is efficient for the extraction of picloram residues in soils, with low limits of detection and quantification.
Resumo:
There is little information about the selectivity of herbicides in physic nut (Jatropha curcas) in Brazil. Therefore, this study aimed to evaluate the selectivity of different doses and mixtures of paraquat and diuron in direted-spray applications in physic nut plants in greenhouse conditions. The study used a randomized block design, with five replicates. The treatments were: paraquat (200 and 600 g ha-1), diuron (1,000 and 2,000 g ha-1), paraquat + diuron (200 + 1,000 g ha-1), paraquat + diuron (200 + 2,000 g ha-1), paraquat + diuron (600 + 1,000 g ha-1), paraquat + diuron (600 + 2,000 g ha-1) and a control (no application). Directed-spray application was performed at 70 days after sowing by the lower third of the plants. The treatments of diuron and paraquat + diuron mixtures affected the growth and photosynthetic activity of physic nut plants, injuries being more pronounced at doses of diuron of 2,000 g ha‑1, while the isolated application of paraquat at doses of 200 and 600 g ha-1 showed good selectivity potential for physic nut plants.