112 resultados para Plasma diagnostic
Resumo:
Many patients with Chagas disease live in remote communities that lack both equipment and trained personnel to perform a diagnosis by conventional serology (CS). Thus, reliable tests suitable for use under difficult conditions are required. In this study, we evaluated the ability of personnel with and without laboratory skills to perform immunochromatographic (IC) tests to detect Chagas disease at a primary health care centre (PHCC). We examined whole blood samples from 241 patients and serum samples from 238 patients. Then, we calculated the percentage of overall agreement (POA) between the two groups of operators for the sensitivity (S), specificity (Sp) and positive (PPV) and negative (NPV) predictive values of IC tests compared to CS tests. We also evaluated the level of agreement between ELISAs and indirect haemagglutination (IHA) tests. The readings of the IC test results showed 100% agreement (POA = 1). The IC test on whole blood showed the following values: S = 87.3%; Sp = 98.8%; PPV = 96.9% and NPV = 95.9%. Additionally, the IC test on serum displayed the following results: S = 95.7%; Sp = 100%; PPV = 100% and NPV = 98.2%. Using whole blood, the agreement with ELISA was 96.3% and the agreement with IHA was 94.1%. Using serum, the agreement with ELISA was 97.8% and the agreement with IHA was 96.6%. The IC test performance with serum samples was excellent and demonstrated its usefulness in a PHCC with minimal equipment. If the IC test S value and NPV with whole blood are improved, then this test could also be used in areas lacking laboratories or specialised personnel.
Resumo:
Orally transmitted Chagas disease has become a matter of concern due to outbreaks reported in four Latin American countries. Although several mechanisms for orally transmitted Chagas disease transmission have been proposed, food and beverages contaminated with whole infected triatomines or their faeces, which contain metacyclic trypomastigotes of Trypanosoma cruzi, seems to be the primary vehicle. In 2007, the first recognised outbreak of orally transmitted Chagas disease occurred in Venezuela and largest recorded outbreak at that time. Since then, 10 outbreaks (four in Caracas) with 249 cases (73.5% children) and 4% mortality have occurred. The absence of contact with the vector and of traditional cutaneous and Romana’s signs, together with a florid spectrum of clinical manifestations during the acute phase, confuse the diagnosis of orally transmitted Chagas disease with other infectious diseases. The simultaneous detection of IgG and IgM by ELISA and the search for parasites in all individuals at risk have been valuable diagnostic tools for detecting acute cases. Follow-up studies regarding the microepidemics primarily affecting children has resulted in 70% infection persistence six years after anti-parasitic treatment. Panstrongylus geniculatushas been the incriminating vector in most cases. As a food-borne disease, this entity requires epidemiological, clinical, diagnostic and therapeutic approaches that differ from those approaches used for traditional direct or cutaneous vector transmission.
Resumo:
There is insufficient evidence of the usefulness of dengue diagnostic tests under routine conditions. We sought to analyse how physicians are using dengue diagnostics to inform research and development. Subjects attending 14 health institutions in an endemic area of Colombia with either a clinical diagnosis of dengue or for whom a dengue test was ordered were included in the study. Patterns of test-use are described herein. Factors associated with the ordering of dengue diagnostic tests were identified using contingency tables, nonparametric tests and logistic regression. A total of 778 subjects were diagnosed with dengue by the treating physician, of whom 386 (49.5%) were tested for dengue. Another 491 dengue tests were ordered in subjects whose primary diagnosis was not dengue. Severe dengue classification [odds ratio (OR) 2.2; 95% confidence interval (CI) 1.1-4.5], emergency consultation (OR 1.9; 95% CI 1.4-2.5) and month of the year (OR 3.1; 95% CI 1.7-5.5) were independently associated with ordering of dengue tests. Dengue tests were used both to rule in and rule out diagnosis. The latter use is not justified by the sensitivity of current rapid dengue diagnostic tests. Ordering of dengue tests appear to depend on a combination of factors, including physician and institutional preferences, as well as other patient and epidemiological factors.
Resumo:
Leprosy inflammatory episodes [type 1 (T1R) and type 2 (T2R) reactions] represent the major cause of irreversible nerve damage. Leprosy serology is known to be influenced by the patient’s bacterial index (BI) with higher positivity in multibacillary patients (MB) and specific multidrug therapy (MDT) reduces antibody production. This study evaluated by ELISA antibody responses to leprosy Infectious Disease Research Institute diagnostic-1 (LID-1) fusion protein and phenolic glycolipid I (PGL-I) in 100 paired serum samples of 50 MB patients collected in the presence/absence of reactions and in nonreactional patients before/after MDT. Patients who presented T2R had a median BI of 3+, while MB patients with T1R and nonreactional patients had median BI of 2.5+ (p > 0.05). Anti-LID-1 and anti-PGL-I antibodies declined in patients diagnosed during T1R (p < 0.05). Anti-LID-1 levels waned in MB with T2R at diagnosis and nonreactional MB patients (p < 0.05). Higher anti-LID-1 levels were seen in patients with T2R at diagnosis (vs. patients with T1R at diagnosis, p = 0.008; vs. nonreactional patients, p = 0.020) and in patients with T2R during MDT (vs. nonreactional MB, p = 0.020). In MB patients, high and persistent anti-LID-1 antibody levels might be a useful tool for clinicians to predict which patients are more susceptible to develop leprosy T2R.
Resumo:
Wing diagnostic characters for Culex quinquefasciatus and Culex nigripalpus (Diptera, Culicidae). Culex quinquefasciatus and Culex nigripalpus are mosquitoes of public health interest, which can occur sympatrically in urban and semi-urban localities. Morphological identification of these species may be difficult when specimens are not perfectly preserved. In order to suggest an alternative taxonomical diagnosis, wings of these species were comparatively characterized using geometric morphometrics. Both species could be distinguished by wing shape with accuracy rates ranging from 85-100%. Present results indicate that one can identify these species relying only on wing characters when traditional taxonomical characters are not visible.
Resumo:
Para aumentar a precisão nas análises químicas de fertilidade do solo e dosar simultaneamente vários elementos, alguns laboratórios vêm optando pelo uso da técnica da espectrofotometria de emissão ótica em plasma induzido (ICP), em detrimento da técnica da espectrofotometria de absorção atômica (EAA), hoje comumente utilizada nos laboratórios de análise de solos. Este trabalho, além de comparar as duas técnicas de dosagem quanto à precisão, à reprodutibilidade e à magnitude dos teores dos micronutrientes Fe, Zn, Cu e Mn, extraídos por Mehlich-1, Mehlich-3 e DTPA-TEA, objetivou, também, selecionar os comprimentos de onda que apresentam menores interferências espectrais no ICP. Foram utilizadas 36 amostras (0 a 0,2 m) de solos coletadas nos Estados de Minas Gerais e Bahia, com ampla variação nos teores de micronutrientes, sendo selecionados três solos para definir os comprimentos de onda do ICP e avaliar a precisão e a reprodutibilidade dos métodos de dosagem. Os comprimentos de onda com menores interferências espectrais no ICP foram: 259,939 nm para Fe em Mehlich-1 e DTPA-TEA e 234,349 nm em Mehlich-3; 213,857 nm para Zn e 324,752 nm para Cu nos três extratores; e 259,372 nm para Mn em Mehlich-1 e DTPA-TEA e 260,568 nm em Mehlich-3. Tanto o ICP quanto o EAA foram precisos e reprodutíveis nas dosagens de Fe e Mn, sendo o ICP, em virtude do seu menor limite de detecção, mais preciso e reprodutível nas dosagens de Zn e Cu. Os métodos de dosagem diferiram estatisticamente (p < 0,01) pelo teste de identidade aplicado, para as dosagens de Fe, Zn, Cu e Mn, utilizando Mehlich-1, Mehlich-3 e DTPA-TEA, comprometendo assim a interpretação dos resultados gerados pelo ICP, com base nos níveis críticos gerados a partir do EAA.
Resumo:
The structural modeling of spatial dependence, using a geostatistical approach, is an indispensable tool to determine parameters that define this structure, applied on interpolation of values at unsampled points by kriging techniques. However, the estimation of parameters can be greatly affected by the presence of atypical observations in sampled data. The purpose of this study was to use diagnostic techniques in Gaussian spatial linear models in geostatistics to evaluate the sensitivity of maximum likelihood and restrict maximum likelihood estimators to small perturbations in these data. For this purpose, studies with simulated and experimental data were conducted. Results with simulated data showed that the diagnostic techniques were efficient to identify the perturbation in data. The results with real data indicated that atypical values among the sampled data may have a strong influence on thematic maps, thus changing the spatial dependence structure. The application of diagnostic techniques should be part of any geostatistical analysis, to ensure a better quality of the information from thematic maps.