116 resultados para Multilayer electrodes


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a comparative study between the procedures of deconvolution and the second-order derivative of square wave voltammograms to achieve separation of the voltammetric peaks of levofloxacin (LEVO) and norfloxacin (NOR), for their simultaneous quantification in urine samples. The obtained results indicate that the use of second-derivative voltammograms coupled with carbon screen-printed electrodes is the most efficient approach for completely separating the voltammetric peaks of LEVO and NOR. In addition, this approach has produced detection limits lower than 1.0 µmol L-1 and a wide linear range for both drugs. The proposed method was successfully used to simultaneously determine LEVO and NOR in spiked human and bovine urine samples with recovery percentages close to 100% for all analyzed samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemically modified electrodes have been studied to obtain new and better electrochemical sensors. Transparent conductive oxides, such as fluorine-doped tin-oxide (FTO), shows electrical conductivity comparable to metals and are potential candidates for new sensors. In this work, FTO was modified by gold electrodeposition from chlorine-auric acid solution using cyclic voltammetry (CV) technique. A set of different materials were produced, varying the scan number. Scanning electron microscopy and electrochemical impedance spectroscopy were performed for the characterization of electrodes surfaces. From this analysis was possible to observe the resistive, capacitive and difusional aspects from all kind of modified electrodes produced, establishing a relationship between this parameters and the scan number. The electrode with 100 scans of CV presented better characteristics for an electrochemical sensor; it has the lowest global impedance and rising of capacitive behavior (related to electrical double layer formation) at lower frequencies. This electrode was tested for paracetamol and caffeine detection. The results showed a high specificity, decreased oxidation potential (0.58 V and 0.97 Vvs. SCE, for paracetamol and caffeine, respectively) and low detection limits (0.82 and 0.052 µmol L-1).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the development of an alternative acetate bath for the electrochemical codeposition of Ni-Cu-Fe electrodes at low pH that is stable for several weeks and produces electrodes with good performance for chlor-alkali electrolysis. Physical characterization of the electrode surface was made using X ray absorption spectroscopy (XAS), scanning electron microscopy (SEM) and energy dispersive analysis (EDX). The evaluation of the material as electrocatalyst for the hydrogen evolution reaction (her) was carried out in brine solution (160 g L-1 NaCl + 150 g L-1 NaOH) at different temperatures through steady-state polarization curves. The Ni-Cu-Fe electrodes obtained with this bath have shown low overpotentials for the her, around 0.150 V at 353 K, and good stability under continuous long-term operation for 260 hours. One positive aspect of this cathode is that the polarization behavior of the material shows only one Tafel slope over the temperature range of 298 - 353 K.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Some aspects of the application of electrochemical impedance spectroscopy to studies of solid electrode / solution interface, in the absence of faradaic processes, are analysed. In order to perform this analysis, gold electrodes with (111) and (210) crystallographic orientations in an aqueous solution containing 10 mmol dm-3 KF, as supporting electrolyte, and a pyridine concentration varying from 0.01 to 4.6 mmol dm-3, were used. The experimental data was analysed by using EQUIVCRT software, which utilises non-linear least squares routines, attributing to the solid electrode / solution interface behaviour described by an equivalent circuit with a resistance in series with a constant phase element. The results of this fitting procedure were analysed by the dependence on the electrode potential on two parameters: the pre-exponential factor, Y0, and the exponent n f, related with the phase angle shift. By this analysis it was possible to observe that the pyridine adsorption is strongly affected by the crystallographic orientation of the electrode surface and that the extent of deviation from ideal capacitive behaviour is mainly of interfacial origin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrodes consisting of Pt nanoparticles dispersed on thin films of niobium oxide were prepared onto titanium substrates by a sol-gel method. The physical characterization of these electrodes was carried out by X-ray diffraction, scanning electron microscopy and energy dispersive X-ray analysis. The mean size of the Pt particles was found to be 10.7 nm. The general aspects of the electrochemical behavior were studied by cyclic voltammetry in 1 mol L-1 HClO4 aqueous solution. The response of these electrodes in relation to the oxidation of formaldehyde and methanol in acidic media was also studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemical oxidation on platinum and platinum rhodium bimetallic electrodes was studied by Differential Electrochemical Mass Spectrometry for several ethanol concentrations in solution. It is found that increasing the ethanol concentration the production of the partially oxidized products (acetaldehyde) increases as the concentration increases. On the other hand, addition of 25% at. of rhodium increases the full oxidation to CO2. Another interesting result observed is a correlation between the intensity of the dehydrogenations peak at 0.3 V vs. RHE and the CO2 yield for the different ethanol concentration studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to a better characterization of a graphite-polyurethane composite intended to be used as a voltammetric sensor, the performance in a square wave voltammetric procedure was investigated. Using hydroquinone (HQ) as a probe, the electrode showed to be useful in square wave voltammetry with limit of detection of 0.28 µmol L-1, with recoveries between 99.1 and 101.5%. The results of the proposed method agreed with HPLC ones within 95% confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pure and Fe(III)-doped TiO2 suspensions were prepared by the sol gel method with the use of titanium isopropoxide (Ti(OPri)4) as precursor material. The properties of doped materials were compared to TiO2 properties based on the characterization by thermal analysis (TG-DTA and DSC), X-ray powder diffractometry and spectroscopy measurements (FTIR). Both undoped and doped TiO2 suspensions were used to coat metallic substrate as a mean to make thin-film electrodes. Thermal treatment of the precursors at 400ºC for 2 h in air resulted in the formation of nanocrystalline anatase TiO2. The thin-film electrodes were tested with respect to their photocatalytic performance for degradation of a textile dye in aqueous solution. The plain TiO2 remains as the best catalyst at the conditions used in this report.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivou-se, neste trabalho, avaliar o ajuste do modelo volumétrico de Schumacher e Hall por diferentes algoritmos, bem como a aplicação de redes neurais artificiais para estimação do volume de madeira de eucalipto em função do diâmetro a 1,30 m do solo (DAP), da altura total (Ht) e do clone. Foram utilizadas 21 cubagens de povoamentos de clones de eucalipto com DAP variando de 4,5 a 28,3 cm e altura total de 6,6 a 33,8 m, num total de 862 árvores. O modelo volumétrico de Schumacher e Hall foi ajustado nas formas linear e não linear, com os seguintes algoritmos: Gauss-Newton, Quasi-Newton, Levenberg-Marquardt, Simplex, Hooke-Jeeves Pattern, Rosenbrock Pattern, Simplex, Hooke-Jeeves e Rosenbrock, utilizado simultaneamente com o método Quasi-Newton e com o princípio da Máxima Verossimilhança. Diferentes arquiteturas e modelos (Multilayer Perceptron MLP e Radial Basis Function RBF) de redes neurais artificiais foram testados, sendo selecionadas as redes que melhor representaram os dados. As estimativas dos volumes foram avaliadas por gráficos de volume estimado em função do volume observado e pelo teste estatístico L&O. Assim, conclui-se que o ajuste do modelo de Schumacher e Hall pode ser usado na sua forma linear, com boa representatividade e sem apresentar tendenciosidade; os algoritmos Gauss-Newton, Quasi-Newton e Levenberg-Marquardt mostraram-se eficientes para o ajuste do modelo volumétrico de Schumacher e Hall, e as redes neurais artificiais apresentaram boa adequação ao problema, sendo elas altamente recomendadas para realizar prognose da produção de florestas plantadas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study provides an update on the use of Transcutaneous Eletric Nerve Stimulation (TENS) as a non-pharmacological resource of postoperative pain relief. National and international references regarding the use of TENS for the relief of postoperative pain had been selected, highlighting its mechanism of action, parameters of application, contraindications, side-effect and results. TENS is a non-pharmacological resource that has its mechanism of action based on the gate theory. It consists of a device that emits electric impulses in the skin through electrodes. It is a low cost technique, easily applicable, presents few collateral effects, good effectiveness related to the reduction of the painful perception, allowing early mobilization and reduced pharmacological analgesic consumption. TENS represents another option in the control of postoperative pain and should be inserted in a multiprofessional context.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: to evaluate the efficacy of endovascular repair of popliteal artery aneurysms on maintaining patency of the stent in the short and medium term. METHODS: this was a retrospective, descriptive and analytical study, conducted at the Integrated Vascular Surgery Service at the Hospital da Beneficência Portuguesa de São Paulo. We followed-up 15 patients with popliteal aneurysm, totaling 18 limbs, treated with stent from May 2008 to December 2012. RESULTS: the mean follow-up was 14.8 months. During this period, 61.1% of the stents were patent. The average aneurysm diameter was 2.5cm, ranging from 1.1 to 4.5cm. The average length was 5cm, ranging from 1.5 to 10 cm. In eight cases (47.1%), the lesion crossed the joint line, and in four of these occlusion of the prosthesis occurred. In 66.7% of cases, treatment was elective and only 33.3% were symptomatic patients treated on an emergency basis. The stents used were Viabahn (Gore) in 12 cases (66.7%), Fluency (Bard) in three cases (16.7%), Multilayer (Cardiatis) in two cases (11.1%) and Hemobahn (Gore) in one case (5.6%). In three cases, there was early occlusion (16.6%). During follow-up, 88.2% of patients maintained antiplatelet therapy. There was no leakage at ultrasound (endoleak). No fracture was observed in the stents. CONCLUSION: the results of this study are similar to other published series. Probably, with the development of new devices that support the mechanical characteristics found on the thighs, there will be improved performance and prognosis of endovascular restoration.