213 resultados para Enzyme-multiplied Immunoassay


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute human parvovirus B19 infection is followed by an antibody response to the structural proteins of the viral capsid (VP1 and VP2). We used 80 sera collected from 58 erythema infectiosum and 6 transient aplastic crisis patients to test IgM and IgG antibodies against these two proteins in an immunofluorescence assay (IFA) using Sf9 cells infected with recombinant baculovirus expressing either VP1 or VP2 antigen. Although less sensitive than IgM capture enzyme immunoassay using native antigen (MACEIA), we could detect anti-VP1 or anti-VP2 IgM antibodies by IFA in 49 patients with acute infection (76.6%). Detection of IgG anti-VP1 and anti-VP2 by IFA, however, was as sensitive as IgG detection by indirect enzyme immunoassay. By applying IgG avidity IFA to sera of the 15 IgM IFA negative patients we were able to confirm acute infection in further 12 cases by IFA. Overall, acute infection was confirmed by IFA in 61 (95.3%) of the 64 patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An hemodialysis population in Central Brazil was screened by polymerase chain reaction (PCR) and serological methods to assess the prevalence of hepatitis C virus (HCV) infection and to investigate associated risk factors. All hemodialysis patients (n=428) were interviewed in eight dialysis units in Goiânia city. Blood samples were collected and serum samples screened for anti-HCV antibodies by an enzyme-linked immunosorbent assay (ELISA). Positive samples were retested for confirmation with a line immunoassay (LIA). All samples were also tested for HCV RNA by the PCR. An overall prevalence of 46.7% (CI 95%: 42-51.5) was found, ranging from 20.7% (CI 95%: 8.8-38.1) to 90.4% (CI 95%: 79.9-96.4) depending on the dialysis unit. Of the 428 patients, 185 were found to be seropositive by ELISA, and 167 were confirmed positive by LIA, resulting in an anti-HCV prevalence of 39%. A total of 131 patients were HCV RNA-positive. HCV viremia was present in 63.5% of the anti-HCV-positive patients and in 10.3% of the anti-HCV-negative patients. Univariate analysis of risk factors showed that the number of previous blood transfusions, transfusion of blood before mandatory screening for anti-HCV, length of time on hemodialysis, and treatment in multiple units were associated with HCV positivity. However, multivariate analysis revealed that blood transfusion before screening for anti-HCV and length of time on hemodialysis were significantly associated with HCV infection in this population. These data suggest that nosocomial transmission may play a role in the spread of HCV in the dialysis units studied. In addition to anti-HCV screening, HCV RNA detection is necessary for the diagnosis of HCV infection in hemodialysis patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A survey on Plasmodium infection was carried out in gold mine camps located in the Brazilian Amazon. Antibody against P. falciparum ring-infected erythrocyte surface antigen (RESA) was quantified by an enzyme-immunoassay in order to assess P. falciparum exposure. Hepatitis B, a common infection in this area, was also investigated by serologic markers. Among 520 sampled subjects, 517 (99.4%) admitted previous symptomatic malaria, 106 (20.4%) had positive thick smears for malaria, 82.9% had HBV markers, and 7.1% were HBsAg positive. Anti-RESA titers was significantly lower in HBV carriers than in people with resolved HBV infection suggesting that the anti-RESA immune response could be supressed by HBV carrier status. Moreover, immunedeficient responses to both infections may take place in some subjects causing concomitant lower anti-RESA response and incapacity to clear HBV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zymovars analysis also known as multilocus enzyme electrophoresis is applied here to investigate the genetic variation of Vibrio cholerae strains and characterise strains or group of strains of medical and epidemiological interest. Fourteen loci were analyzed in 171 strains of non-O1 non-O139, 32 classical and 61 El Tor from America, Africa, Europe and Asia. The mean genetic diversity was 0.339. It is shown that the same O antigen (both O1 and non-O1) may be present in several geneticaly diverse (different zymovars) strains. Conversely the same zymovar may contain more than one serogroup. It is confirmed that the South American epidemic strain differs from the 7th pandemic El Tor strain in locus LAP (leucyl leucyl aminopeptidase). Here it is shown that this rare allele is present in 1 V. mimicus and 4 non-O1 V. cholerae. Non toxigenic O1 strains from South India epidemic share zymovar 14A with the epidemic El Tor from the 7th pandemic, while another group have diverse zymovars. The sucrose negative epidemic strains isolated in French Guiana and Brazil have the same zymovar of the current American epidemic V. cholerae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study developed and standardized an enzime-linked immunosorbent assay (ELISA) to detect Giardia antigen in feces using rabbit polyclonal antibodies. Giardia cysts were purified from human fecal samples by sucrose and percoll gradients. Gerbils (Meriones unguiculatus) were infected to obtain trophozoites. Rabbits were inoculated with either cyst or trophozoite antigens of 14 Colombian Giardia isolates to develop antibodies against the respective stages. The IgG anti-Giardia were purified by sequential caprylic acid and ammonium sulfate precipitation. A portion of these polyclonal antibodies was linked to alkaline phosphatase (conjugate). One hundred and ninety six samples of human feces, from different patients, were tested by parasitologic diagnosis: 69 were positive for Giardia cysts, 56 had no Giardia parasites, and 71 revealed parasites other than Giardia. The optimal concentration of polyclonal antibodies for antigen capture was 40 µg/ml and the optimal conjugate dilution was 1:100. The absorbance cut-off value was 0.24. The parameters of the ELISA test for Giardia antigen detection were: sensitivity, 100% (95% CI: 93.4-100%); specificity, 95% (95% CI: 88.6-97.6%); positive predictive value, 91% (95% CI: 81.4-95.9%); and negative predictive value, 100% (95% CI: 96.1-100%). This ELISA will improve the diagnosis of Giardia infections in Colombia and will be useful in following patients after treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 2,605 faecal specimens from children up to 10 years old with or without diarrhoea were collected. Samples were obtained from 1986 to 2000 in hospitals, outpatient clinics and day-care centers in Goiânia, Goiás. Two methodologies for viral detection were utilized: a combined enzyme immunoassay for rotavirus and adenovirus and polyacrylamide gel electrophoresis. Results showed 374 (14.4%) faecal specimens positive for Rotavirus A, most of them collected from hospitalized children. A significant detection rate of rotavirus during the period from April to August, dry season in Goiânia, and different frequencies of viral detection throughout the years of study were also observed. Rotavirus was significantly related to hospitalization and to diarrhoeal illness in children up to 24 months old. This study reinforces the importance of rotavirus as a cause of diarrhoea in children and may be important in regards to the implementation of rotavirus vaccination strategies in our country.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study was conducted to detected IgG antibodies using Strongyloides venezuelensis alkaline extract for the diagnosis of human strongyloidiasis by the enzyme-linked immunosorbent assay (ELISA). Sera from 90 subjects were analyzed (30 with strongyloidiasis, 30 with other parasites and 30 healthy individuals). Results were expressed in antibody titers, which were considered as positive when titer was > 80. Sensibility and specificity of the assay were 100% and 96.7%, respectively. It can be concluded that the heterologous alkaline extract could be employed in ELISA as a diagnostic aid in human strongyloidiasis, due to its advantages as easiness of obtaining, practicability in preparing, and high indexes of sensitivity and specificity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the significance of injecting vitamins complexes and stimulants minutes before soccer games and its role in spread of hepatitis C virus (HCV) we interviewed and tested 40 ex-soccer players, who played professionally in Mato Grosso, Brazil, between 1970 and 1989. Five players were found anti-HCV positive with enzyme-immunoassay. When re-tested by imunoblot (RIBA), three of these five were confirmed to be positive reacting. The anti-HCV positivity (7.5%) was higher than usually found among blood donors (0.9%) in this region (p < 0.01). None of the players had had prior history of any risk factor that might indicate HCV exposure. We suggest that the common practice of soccer players in the inner part of Brazil in the 70's and 80's, to receive fortifying injections, often with shared syringes, may place ex-soccer players in a potencial risk group for HCV infection and warrants further investigation and attention by public health workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to verify the occurrence of Cryptosporidium infection in 52 human immunodeficiency virus (HIV)/acquired immunodeficiency syndrome (AIDS) patients (group 1) and 38 clinically healthy individuals (group 2) by using enzyme immunoassay (EIA). All fecal samples collected were submitted to the Baermann, Lutz, and Ritchie methods, the Safranin/Methylene Blue, and Weber's chromotrope modified Trichrome staining techniques, and EIA. In group 1, parasitological staining techniques and EIA were both positive for Cryptosporidium sp. infection in 3/52 (5.8%) samples and both negative in 45/52 (86.5%) samples, while 4/52 (7.7%) samples were positive in EIA and negative in parasitological staining techniques. Concerning group 2, all samples were negative by EIA and microscopy for Cryptosporidium infection. In conclusion, EIA may be an alternative method for detecting Cryptosporidium-specific coproantigen in HIV/AIDS patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Of the 110 dentists who had presented seroconversion 50 days after the intradermal application of three 2 µg doses of the Belgian recombinant vaccine against hepatitis B (HB), administered eight years before at an interval of one month between the 1st and 2nd doses and of five months between the 2nd and 3rd doses, 51 were included for the assessment of the persistence of immunity. None of the dentists had hepatitis or had received HB vaccine during this period. All subjects were submitted to serological tests for the detection of the following markers of hepatitis B virus (HBV) infection: HBsAg, anti-HBc, HBeAg, anti-HBe, and anti-HBs, with no HBsAg, anti-HBc, HBeAg or anti-HBe being detected. A microparticle enzyme immunoassay (MEIA) revealed the presence of anti-HBs at protective titers (> 10 mIU/ml) in 42 dentists (82.4%), with the anti-HBs titer being higher than 100 mIU/ml in 36 of them (70.6%) (good responders), between 10 and 100 mIU/ml in 6 (11.8%) (poor responders), and lower than 10 mIU/ml in 9 (17.6%) (non-responders). According to clinical data and serological tests, none of the dentists had presented disease or latent HBV infection during the eight years following the first vaccination. A 2 µg booster dose was administered intradermally to eight dentists with anti-HBs titers lower than 10 mIU/ml (non-responders) and to six dentists with titers ranging from 10 to 100 mIU/ml (poor responders); the determination of anti-HBs one month later demonstrated the occurrence of seroconversion in the eight non-responders and an increase in anti-HBs titer in the six poor responders. In summary, the present results demonstrated the prolonged persistence of protection against HBV infection and the development of immunologic memory provided by vaccination against HB - with intra-dermal application of three 2 µg doses of the Belgian recombinant vaccine at 0, 1, and 6 months - carried out eight years before in 51 dentists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Entamoeba histolytica actually comprises two genetically distinct but morphologically indistinguishable species. E. histolytica can cause invasive intestinal and extra intestinal disease, while E. dispar cannot. Identification and differentiation of E. dispar and E. histolytica in stool sample by microscopy is imprecise. Several weeks of culture and isoenzyme analysis are required to differentiate E. histolytica from E. dispar. In this study, we have used an enzyme-linked immunosorbent assay (ELISA) for detection of E. histolytica/E.dispar and compared it with microscopy. Eighty-eight samples were evaluated, trichrome staining was positive in 20.4% (18) and ELISA was positive in 29.5% (26). Both tests were positive in 14 (15.9%) samples, 4 (4.5%) only with direct microscopy, and 12 (13.6%) only with ELISA. Both tests were negative in 58 (65.9%) samples. Microscopy has low sensitivity and high specificity, low negative predictive value and high positive predictive value in comparison with ELISA. E. histolytica/E. dispar antigen detection ELISA tests are inexpensive compared to the specific tests, yield objective results and do not require experienced microscopists and can therefore be recommended for screening of stools worldwide and the results can be taken for treatment that are fitting with its clinic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performances of ELISA assays with different antigen preparations, such as Leishmania amazonensis or L. chagasi lysates and the recombinant antigens rK-39 and rK-26, were compared using sera or eluates from dried blood collected on filter paper to detect anti-Leishmania antibodies in dogs from a visceral leishmaniasis-endemic area in Brazil. Of 115 IFAT-reactive dogs at 1:40 titre, 106 (92.2%) were positive in parasitological exams (skin and/or spleen). These animals were compared to healthy animals (n = 25), negative for IFAT at a titre of 1:40 and parasitological exams. The sensitivities of crude and recombinant antigens were similar and remarkably high for both sera and eluates (97-100%). Specificity was higher than 96% for sera and eluates for different antigens, except for L. chagasi antigen using eluates (88%). Concordance values among the tests were higher either for sera or eluates (J = 0.95-1.00). High concordances were observed between sera and eluates tested with different antigens (kappa = 0.93-0.97). Crude and recombinant antigens identified different clinical phases of canine leishmaniasis. These results show that eluates could be used in canine surveys to identify L. chagasi infection. Recombinant antigens added little when compared to crude antigen in identifying positive dogs. Cross-reactivity with other diseases whose distribution often overlaps VL-endemic areas is a limitation of crude antigen use however.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An evaluation of the sensitivity and the specificity of the Anisakis simplex antigens purified by affinity chromatography was performed using sera from patients diagnosed with Anisakis sensitisation and sera from patients previously diagnosed with different helminthic infections. Only the sera of the patients diagnosed with Schistosoma mansoni or Onchocerca volvulus parasitic infections were negative against the A. simplex antigen and its purified fractions (PAK antigen: A. simplex antigen purified using columns prepared with anti-A. simplex rabbit IgG and PAS antigen: PAK antigen purified using columns prepared with anti-Ascaris suum rabbit IgG). However all the sera were positive against the A. suum antigen. In all the sera from the patients diagnosed with Anisakis sensitisation, the antibody levels detected using the purified antigens (PAK and PAS antigens) were lower than the observed using the A. simplex crude extract with the highest diminution in the case of the IgG. When these same sera were tested against the A. simplex crude extract by Western blot, several bands of high molecular masses were observed as well as, intense bands at 60 and/or 40 kDa. A concentration of these last proteins was observed in the PAK and the PAS antigens. When the sensitivity and the specificity determinations were performed, only seven of the 38 patients diagnosed of Anisakis sensitisation were positive, as well as, the sera from the patients diagnosed with parasitisms by Echinococcus granulosus or Fasciola hepatica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IgM-ELISA is an immunoenzymatic method useful for detection of IgM antibodies against a fraction of Schistosoma mansoni adult worm antigen (AWA) that is soluble in trichloroacetic acid (AWA-TCA). This method was applied to three groups of individuals with different clinical and epidemiological characteristics, and the results compared with those obtained by other diagnostic methods: immunofluorescence test for detection of IgM antibodies (IgM-IFT) or IgG antibodies (IgG-IFT), ELISA for detection of IgG antibodies (IgG-ELISA), and two parasitological methods, Kato-Katz and miracidium hatching. The IgM-ELISA presented a sensitivity of 98%, when the parasitologic fecal examination was defined as reference diagnostic method, and a specificity of 98 and 97.3%, respectively for the group of clinically healthy individuals and other helminth carriers. A comparative analysis between the results of IgM-ELISA and those obtained by other serologic tests showed a good degree of agreement, with Kappa indices ranging from 0.95 to 0.98. The diagnostic efficacy of 97.8%, as determined with schistosomiasis patients with low parasitic burden, suggests the excellent performance of the IgM-ELISA and its usefulness for the diagnosis of schistosomiasis when applied in low endemic areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this work were to determine the prevalence of Babesia bovis, Babesia bigemina, and Anaplasma marginale detecting antibodies in cattle raised in the semi-arid region of the state of Bahia, Brazil, through indirect enzyme linked immunosorbent assays (ELISA) and to compare the performances of indirect enzyme-linked immunosorbent assays with crude (I-ELISA-CrAnaAg) and recombinant major surface protein-5 (I-ELISA-MSP-5Ag), as antigens to detect antibodies against A. marginale. An stable enzootic area was found in Senhor do Bonfim and Euclides da Cunha for B. bovis that showed 86 and 95.5% of prevalence, respectively, and for B. bigemina with 90.8 and 91.3%. On the other hand, Uauá and Juazeiro, were characterized as enzootically unstable areas, since prevalences were: B. bovis - 63.7 and 56.4% and B. bigemina - 53 and 54.8%, respectively. The prevalence of A. marginale in the four municipalities was above 97% with I-ELISA-CrAnaAg and 94.8% with I-ELISA-MSP-5Ag which is an indication of stable enzootic condition for the rickettsia. The I-ELISA-CrAnaAg and I-ELISA-MSP-5Ag showed a highly significant association (r = 0.977), which means that both ELISA tests are suitable for epidemiological studies of A. marginale.