213 resultados para Enzyme immunoassay


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dacron and nitrocellulose were evaluated as matrices for the dot enzyme linked immunosorbent assay (dot-ELISA) for schistosomiasis and compared to indirect immunofluorescence (IMF). Titration of sera from 18 schistosomiasis patients against soluble worm antigen preparation (SWAP) was carried out and sera from healthy individuals from non-endemic areas were used as controls. The IMF was less sensitive than the dot-ELISAs, although the difference was not statistically significant (p > 0.05). The dot-ELISA based on nitrocellulose was as sensitive as that using dacron. Stability did not differ between nitrocellulose and dacron. Specificity was lower when dacron was used than when nitrocellulose was used, although the difference was not statistically significant (p > 0.05). In conclusion, this work showed that nitrocellulose and dacron performed similarly in dot-ELISA, suggesting that they may be used alternatively in population surveillance in endemic areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Human cytomegalovirus is an opportunistic betaherpesvirus that causes persistent and serious infections in immunodeficient patients. Recurrent infections occur due to the presence of the virus in a latent state in some cell types. It is possible to examine the virus using molecular methods to aid in the immunological diagnosis and to generate a molecular viral profile in immunodeficient patients. The objective of this study was to characterize cytomegalovirus genotypes and to generate the epidemiological and molecular viral profile in immunodeficient patients. METHODS: A total of 105 samples were collected from immunodeficient patients from the City of Belém, including newborns, hemodialysis patients, transplant recipients and HIV+ patients. An IgG and IgM antibody study was completed using ELISA, and enzymatic analysis by restriction fragment length polymorphism (RFLP) was performed to characterize viral genotypes. RESULTS: It was observed that 100% of the patients had IgG antibodies, 87% of which were IgG+/IgM-, consistent with a prior infection profile, 13% were IgG+/IgM+, suggestive of recent infection. The newborn group had the highest frequency (27%) of the IgG+/IgM+ profile. By RFLP analysis, only one genotype was observed, gB2, which corresponded to the standard AD169 strain. CONCLUSIONS: The presence of IgM antibodies in new borns indicates that HCMV continues to be an important cause of congenital infection. The low observed genotypic diversity could be attributed to the small sample size because newborns were excluded from the RFLP analysis. This study will be continued including samples from newborns to extend the knowledge of the general and molecular epidemiology of HCMV in immunodeficient patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Domestic dogs are the most important reservoir in the peridomestic transmission cycle of Leishmania (Leishmania) chagasi. The genetic variability of subpopulations of this parasite circulating in dogs has not been thoroughly analyzed in Brazil, even though this knowledge has important implications in the clinical-epidemiological context. METHODS: The objective of this study was to evaluate and compare the phenotypic variability of 153 L. chagasi strains isolated from dogs originating from the municipalities of Rio de Janeiro (n = 57) and Belo Horizonte (n = 96), where the disease is endemic. Strains isolated only from intact skin were selected and analyzed by multilocus enzyme electrophoresis using nine enzyme systems (6PG, GPI, NH1 and NH2, G6P, PGM, MDH, ME, and IDHNADP). RESULTS: The electrophoretic profile was identical for all isolates analyzed and was the same as that of the L. chagasi reference strain (MHOM/BR/74/PP75). Phenetic analysis showed a similarity index of one for all strains, with the isolates sharing 100% of the characteristics analyzed. CONCLUSIONS: The results demonstrate that the L. chagasi populations circulating in dogs from Rio de Janeiro and Belo Horizonte belong to a single zymodeme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Epidemiological studies on amebiasis have been reassessed since Entamoeba histolytica and E. dispar were first recognized as distinct species. Because the morphological similarity of these species renders microscopic diagnosis unreliable, additional tools are required to discriminate between Entamoeba species. The objectives of our study were to compare microscopy with ELISA kit (IVD®) results, to diagnose E. histolytica infection, and to determine the prevalence of amebiasis in a sample of students from southeastern Brazil. Methods: In this study, diagnosis was based on microscopy due to its capacity for revealing potential cysts/trophozoites and on two commercial kits for antigen detection in stool samples. Results: For 1,403 samples collected from students aged 6 to 14 years who were living in Divinópolis, Minas Gerais, Brazil, microscopy underestimated the number of individuals infected with E. histolytica/E. dispar (5.7% prevalence) compared with the ELISA kit (IVD®)-based diagnoses (15.7% for E. histolytica/E. dispar). A comparison of the ELISA (IVD®) and light microscopy results returned a 20% sensitivity, 97% specificity, low positive predictive value, and high negative predictive value for microscopy. An ELISA kit (TechLab®) that was specific for E. histolytica detected a 3.1% (43/1403) prevalence for E. histolytica infection. Conclusions: The ELISA kit (IVD®) can be used as an alternative screening tool. The high prevalence of E. histolytica infection detected in this study warrants the implementation of actions directed toward health promotion and preventive measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Despite the known importance of Clostridium difficile as a nosocomial pathogen, few studies regarding Clostridium difficile infection (CDI) in Brazil have been conducted. To date, the diagnostic tests that are available on the Brazilian market for the diagnosis of CDI have not been evaluated. The aim of this study was to compare the performances of four commercial methods for the diagnosis of CDI in patients from a university hospital in Brazil. Methods Three enzyme immunoassays (EIAs) and one nucleic acid amplification test (NAAT) were evaluated against a cytotoxicity assay (CTA) and toxigenic culture (TC). Stool samples from 92 patients with suspected CDI were used in this study. Results Twenty-five (27.2%) of 92 samples were positive according to the CTA, and 23 (25%) were positive according to the TC. All EIAs and the NAAT test demonstrated sensitivities between 59 and 68% and specificities greater than 91%. Conclusions All four methods exhibited low sensitivities for the diagnosis of CDI, which could lead to a large number of false-negative results, an increased risk of cross-infection to other patients, and overtreatment with empirical antibiotics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE: To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for measuring serum vancomycin concentrations. METHODS: Eighteen peak and 20 trough serum samples were assayed for vancomycin concentrations using high performance liquid chromatography and flourescence polarization immunoassay from October 1995 to October 1997. RESULTS: The linear correlation coefficients for high performance liquid chromatography and flourescence polarization immunoassay were 0.27 (peak, P = 0.110) and 0.26 (trough, P = 0.1045) respectively, which were not statistically significant. CONCLUSION: There was wide variation in serum vancomycin concentrations determined by high performance liquid chromatography as compared with those determined by flourescence polarization immunoassay. There was no recognizable pattern in the variability; in an apparently random fashion, the high performance liquid chromatography measurement was sometimes substantially higher than the flourescence polarization immunoassay measurement, and at other times it was substantially lower.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare blood pressure response to dynamic exercise in hypertensive patients taking trandolapril or captopril. METHODS: We carried out a prospective, randomized, blinded study with 40 patients with primary hypertension and no other associated disease. The patients were divided into 2 groups (n=20), paired by age, sex, race, and body mass index, and underwent 2 symptom-limited exercise tests on a treadmill before and after 30 days of treatment with captopril (75 to 150 mg/day) or trandolapril (2 to 4 mg/day). RESULTS: The groups were similar prior to treatment (p<0.05), and both drugs reduced blood pressure at rest (p<0.001). During treatment, trandolapril caused a greater increase in functional capacity (+31%) than captopril (+17%; p=0.01) did, and provided better blood pressure control during exercise, observed as a reduction in the variation of systolic blood pressure/MET (trandolapril: 10.7±1.9 mmHg/U vs 7.4±1.2 mmHg/U, p=0.02; captopril: 9.1±1.4 mmHg/U vs 11.4±2.5 mmHg/U, p=0.35), a reduction in peak diastolic blood pressure (trandolapril: 116.8±3.1 mmHg vs 108.1±2.5 mmHg, p=0.003; captopril: 118.2±3.1 mmHg vs 115.8±3.3 mmHg, p=0.35), and a reduction in the interruption of the tests due to excessive elevation in blood pressure (trandolapril: 50% vs 15%, p=0.009; captopril: 50% vs 45%, p=0.32). CONCLUSION: Monotherapy with trandolapril is more effective than that with captopril to control blood pressure during exercise in hypertensive patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: End-stage kidney disease patients continue to have markedly increased cardiovascular disease morbidity and mortality. Analysis of genetic factors connected with the renin-angiotensin system that influences the survival of the patients with end-stage kidney disease supports the ongoing search for improved outcomes. Objective: To assess survival and its association with the polymorphism of renin-angiotensin system genes: angiotensin I-converting enzyme insertion/deletion and angiotensinogen M235T in patients undergoing hemodialysis. Methods: Our study was designed to examine the role of renin-angiotensin system genes. It was an observational study. We analyzed 473 chronic hemodialysis patients in four dialysis units in the state of Rio de Janeiro. Survival rates were calculated by the Kaplan-Meier method and the differences between the curves were evaluated by Tarone-Ware, Peto-Prentice, and log rank tests. We also used logistic regression analysis and the multinomial model. A p value ≤ 0.05 was considered to be statistically significant. The local medical ethics committee gave their approval to this study. Results: The mean age of patients was 45.8 years old. The overall survival rate was 48% at 11 years. The major causes of death were cardiovascular diseases (34%) and infections (15%). Logistic regression analysis found statistical significance for the following variables: age (p = 0.000038), TT angiotensinogen (p = 0.08261), and family income greater than five times the minimum wage (p = 0.03089), the latter being a protective factor. Conclusions: The survival of hemodialysis patients is likely to be influenced by the TT of the angiotensinogen M235T gene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Cardiovascular disease is the leading cause of mortality in the western world and its treatment should be optimized to decrease severe adverse events.Objective:To determine the effect of previous use of angiotensin-converting enzyme inhibitors on cardiac troponin I measurement in patients with acute coronary syndrome without ST-segment elevation and evaluate clinical outcomes at 180 days.Methods:Prospective, observational study, carried out in a tertiary center, in patients with acute coronary syndrome without ST-segment elevation. Clinical, electrocardiographic and laboratory variables were analyzed, with emphasis on previous use of angiotensin-converting enzyme inhibitors and cardiac troponin I. The Pearson chi-square tests (Pereira) or Fisher's exact test (Armitage) were used, as well as the non-parametric Mann-Whitney's test. Variables with significance levels of <10% were submitted to multiple logistic regression model.Results:A total of 457 patients with a mean age of 62.1 years, of whom 63.7% were males, were included. Risk factors such as hypertension (85.3%) and dyslipidemia (75.9%) were the most prevalent, with 35% of diabetics. In the evaluation of events at 180 days, there were 28 deaths (6.2%). The statistical analysis showed that the variables that interfered with troponin elevation (> 0.5 ng / mL) were high blood glucose at admission (p = 0.0034) and ST-segment depression ≥ 0.5 mm in one or more leads (p = 0.0016). The use of angiotensin-converting inhibitors prior to hospitalization was associated with troponin ≤ 0.5 ng / mL (p = 0.0482). The C-statistics for this model was 0.77.Conclusion:This study showed a correlation between prior use of angiotensin-converting enzyme inhibitors and reduction in the myocardial necrosis marker troponin I in patients admitted for acute coronary syndrome without ST-segment elevation. However, there are no data available yet to state that this reduction could lead to fewer severe clinical events such as death and re-infarction at 180 days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dacron (polyethylenetherephthalate) is proposed as a matrix for dot-ELISA procedures, as an alternative to nitrocellulose. Plates of dacron were partially hydrazinolyzed and hydrazide groups introduced were converted to azide groups. The derivative dacron-antigen was covalently linked on to the plates through these azide groups. The derivative dacron-antigen was exaustively washed according to CROOK and antigen was still fixed onto the plates. Protein F1A purified from Yersinia pestis was used as a model. Triration of sera from immunized and non immunized rabbits against this protein was carried out by employing the dot-ELISA method. No significant difference was observed using dacron-antigen and nitrocellulose-antigen preparations. However, both procedures showed to have a significant better performance in comparasion with the passive hemagglutination method. The specificity and reproductibility of the dot-ELISA assay using both preparations showed a similar behaviour. Nitrocellulose preparation was stable at 4ºC, 28ºC and -20ºC for 90 days, whereas the dacron-antigen derivative was stable only when stored at 4ºC. Dacron-antigen derivative could be re-used when the spot developing was proceeded using 4-chloro-1-naphtol as substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new serological assay dot-dye-immunoassay (dot-DIA) was evaluated for the diagnosis of schistosomiasis mansoni. This method consist of four steps: (a) biding of antigens to a nitrocellulose membrane (NC); (b) blocking of free sites of the NC; (c) incubation in specific primary antibody; (d) detection of primary antibody reactivity by color development using second antibody coupled to textile dyes. Sera from 82 individuals, 61 with Schistosoma mansoni eggs in the stool and 21 stool negative were tested by ELISA, dot-ELISA, and dotDIA. A high level of agreement between the methods tested was observed for all sera tested: ELISA x dot-ELISA: 95.1%, ELISA x dot-DIA: 92.7% and dot-ELISA x dot-DIA: 97.6%. In this study, dot-DIA proved to be a feasible, sensitive, rapid and practical test for the diagnosis of shcistosomiasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dot enzyme linked immunosorbent assay (dot-ELISA) was previously developed to detect specific antibodies in rabbits sera immunized against FIA protein obtained from Yersina pestis. This antigen was covalently linked onto the surface of dacron (polyethyleneterephthalate). Here, standard conditions are described for the optimization of this procedure: an amount of 20 ng of FIA protein was fixed onto dacron; anti-rabbit IgG peroxidase conjugate diluted 1:8,000 and 30% non-fat instant milk as blocking substance were used throughout the method. This procedure was compared with that employing nitrocellulose as solid-phase which showed to be more sensitive. However, the method based on dacron did not show false positive reactions against non-immunized rabbits sera at low antigen amount and diluted anti-IgG peroxidase conjugate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We herein present an improved assay for detecting the presence of Trypanosoma cruzi in infected cultures. Using chagasic human sera (CHS), we were able to detect T. cruzi infection in primary cultures of both peritoneal macrophages and heart muscle cells (MHC). To avoid elevated background levels - hitherto observed in all experiments especially in those using HMC - CHS were preincubated with uninfected cells in monolayers or suspensions prior to being used for detection of T. cruzi in infected monolayers. Preincubation with cell suspensions gave better results than with monolayers, reducing background by up to three times and increasing sensitivity by to twenty times. In addition, the continous fibroplastic cell line L929 was shown to be suitable for preadsorption of CHS. These results indicate that the high background levels observed in previous reports may be due to the presence of human autoantibodies that recognize surface and/or extracellular matrix components in cell monolayers. We therefore propose a modified procedure that increases the performance of the ELISA method, making it an useful tool even in cultures that would otherwise be expected to present low levels of infection or high levels of background