114 resultados para Detection sensitivity
Resumo:
More precise and rapid diagnostic methods for American cutaneous leishmaniasis (ACL) are necessary because of the growing number of cases observed in Brazil, including the northeastern region of the State of São Paulo. We applied PCR to 54 skin or mucosal biopsies from patients with a clinical and/or laboratory diagnosis of ACL using primers 13A and 13B, with positive results being obtained for 82% of the samples. When the PCR results were compared to those of histopathological leishmania detection, PCR showed superior results with 81.5% sensitivity and 95% CI of 68.0-95.1%. The Montenegro skin test (MST) was positive in 88.7% of patients. Since MST cannot be used as a diagnostic tool in endemic areas, the present results strongly suggest the use of PCR for the etiological confirmation of ACL, with emphasis on the mucosal form.
Resumo:
Ventricular late potentials are low-amplitude signals originating from damaged myocardium and detected on the body surface by ECG filtering and averaging. Digital filters present in commercial equipment may interfere with the ability of arrhythmia stratification. We compared 40-Hz BiSpec (BI) and classical 40- to 250-Hz band-pass Butterworth bidirectional (BD) filters in terms of impact on time domain variables and diagnostic properties. In a transverse retrospective age-adjusted case-control study, 221 subjects with sinus rhythm without bundle branch block were divided into three groups after signal-averaged ECG acquisition: GI (N = 40), clinically normal controls, GII (N = 158), subjects with coronary heart disease without sustained monomorphic ventricular tachycardia (SMVT), and GIII (N = 23), subjects with heart disease and documented SMVT. Conventional variables analyzed from vector magnitude data after averaging to 0.3 µV final noise were obtained by application of each filter to the averaged signal, and evaluated in pairs by numerical comparison and by diagnostic agreement assessment, using conventional and optimized thresholds of normality. Significant differences were found between BI and BD variables in all groups, with diagnostic results showing significant disagreement between both filters [kappa value of 0.61 (P<0.05) for GII and 0.31 for GIII (P = NS)]. Sensitivity for SMVT was lower with BI than with BD (65.2 vs 91.3%, respectively, P<0.05). Filters provided significantly different numerical and diagnostic results and the BI filter showed only limited clinical application to risk stratification of ventricular arrhythmia.
Resumo:
We analyzed the genetic recombination pattern of the T-cell receptor beta-chain gene (TCR-beta) in order to identify clonal expansion of T-lymphocytes in 17 human T-lymphotropic virus type I (HTLV-I)-positive healthy carriers, 7 of them with abnormal features in the peripheral blood lymphocytes. Monoclonal or oligoclonal expansion of T-cells was detected in 5 of 7 HTLV-I-positive patients with abnormal lymphocytes and unconfirmed diagnosis by using PCR amplification of segments of TCR-beta gene, in a set of reactions that target 102 different variable (V) segments, covering all members of the 24 V families available in the gene bank, including the more recently identified segments of the Vbeta-5 and Vbeta-8 family and the two diversity beta segments. Southern blots, the gold standard method to detect T-lymphocyte clonality, were negative for all of these 7 patients, what highlights the low sensitivity of this method that requires a large amount of very high quality DNA. To evaluate the performance of PCR in the detection of clonality we also analyzed 18 leukemia patients, all of whom tested positive. Clonal expansion was not detected in any of the negative controls or healthy carriers without abnormal lymphocytes. In conclusion, PCR amplification of segments of rearranged TCR-beta is reliable and highly suitable for the detection of small populations of clonal T-cells in asymptomatic HTLV-I carriers who present abnormal peripheral blood lymphocytes providing an additional instrument for following up these patients with potentially higher risk of leukemia.
Resumo:
The aim of the present study was to develop a classifier able to discriminate between healthy controls and dyspeptic patients by analysis of their electrogastrograms. Fifty-six electrogastrograms were analyzed, corresponding to 42 dyspeptic patients and 14 healthy controls. The original signals were subsampled, filtered and divided into the pre-, post-, and prandial stages. A time-frequency transformation based on wavelets was used to extract the signal characteristics, and a special selection procedure based on correlation was used to reduce their number. The analysis was carried out by evaluating different neural network structures to classify the wavelet coefficients into two groups (healthy subjects and dyspeptic patients). The optimization process of the classifier led to a linear model. A dimension reduction that resulted in only 25% of uncorrelated electrogastrogram characteristics gave 24 inputs for the classifier. The prandial stage gave the most significant results. Under these conditions, the classifier achieved 78.6% sensitivity, 92.9% specificity, and an error of 17.9 ± 6% (with a 95% confidence level). These data show that it is possible to establish significant differences between patients and normal controls when time-frequency characteristics are extracted from an electrogastrogram, with an adequate component reduction, outperforming the results obtained with classical Fourier analysis. These findings can contribute to increasing our understanding of the pathophysiological mechanisms involved in functional dyspepsia and perhaps to improving the pharmacological treatment of functional dyspeptic patients.
Resumo:
Acute cerebral hemorrhage (ACH) is an important clinical problem that is often monitored and studied with expensive devices such as computed tomography, magnetic resonance imaging, and positron emission tomography. These devices are not readily available in economically underdeveloped regions of the world, emergency departments, and emergency zones. We have developed a less expensive tool for non-contact monitoring of ACH. The system measures the magnetic induction phase shift (MIPS) between the electromagnetic signals on two coils. ACH was induced in 6 experimental rabbits and edema was induced in 4 control rabbits by stereotactic methods, and their intracranial pressure and heart rate were monitored for 1 h. Signals were continuously monitored for up to 1 h at an exciting frequency of 10.7 MHz. Autologous blood was administered to the experimental group, and saline to the control group (1 to 3 mL) by injection of 1-mL every 5 min. The results showed a significant increase in MIPS as a function of the injection volume, but the heart rate was stable. In the experimental (ACH) group, there was a statistically significant positive correlation of the intracranial pressure and MIPS. The change of MIPS was greater in the ACH group than in the control group. This high-sensitivity system could detect a 1-mL change in blood volume. The MIPS was significantly related to the intracranial pressure. This observation suggests that the method could be valuable for detecting early warning signs in emergency medicine and critical care units.
Resumo:
The quantification of human cytomegalovirus (HCMV DNA) by real-time PCR is currently a primary option for laboratory diagnosis of HCMV infection. However, the optimal sample material remains controversial due to the use of different PCR assays. To explore the best blood component for HCMV DNA surveillance after liver transplantation, whole blood (WB), serum (SE), and plasma (PL) specimens were collected simultaneously from targeted patients and examined for HCMV DNA using one commercially available assay. The HCMV DNA-positive rate with WB (16.67%) was higher than that with either SE or PL (8.33%, both P<0.01). Quantitative DNA levels in WB were of greater magnitude than those in SE (WB-SE mean log-transformed difference, 0.99; 95%CI=0.74-1.25; P<0.0001) and PL (WB-PL mean log-transformed difference, 1.37; 95%CI=1.07-1.66; P<0.0001). Dynamic monitoring revealed that HCMV DNA in WB was positive sooner and had higher values for a longer period of time during therapy. With earlier positive detection, higher sensitivity, and yield of greater viral loads, WB compared favorably to SE or PL and hence is recommended as the superior material for HCMV DNA surveillance after liver transplantation. In addition, infant recipients require more intensive monitoring and prophylactic care because of their higher susceptibility to primary HCMV infection.
Resumo:
Resistance to Mycobacterium tuberculosis is a reality worldwide, and its diagnosis continues to be difficult and time consuming. To face this challenge, the World Health Organization has recommended the use of rapid molecular tests. We evaluated the routine use (once a week) of a line probe assay (Genotype MTBDRplus) for early diagnosis of resistance and for assessment of the main related risk factors over 2 years. A total of 170 samples were tested: 15 (8.8%) were resistant, and multidrug resistance was detected in 10 (5.9%). The sensitivity profile took 3 weeks (2 weeks for culture and 1 week for rapid testing). Previous treatment for tuberculosis and the persistence of positive acid-fast smears after 4 months of supervised treatment were the major risk factors observed. The use of molecular tests enabled early diagnosis of drug-resistant bacilli and led to appropriate treatment of the disease. This information has the potential to interrupt the transmission chain of resistant M. tuberculosis.
Resumo:
The aim of this study was to verify the efficiency of the BAX® system for the detection of Salmonella spp. in raw chicken meat. The conventional culture method (IN 62, MAP) was used as a reference method. A total of 8,813 chicken carcass samples were analyzed. In the first part of the study, 1,200 samples were analyzed using the BAX® System and the conventional culture method. In the second part, 7,613 samples were analyzed by the BAX® system, and the conventional method was used only for samples that tested positive for Salmonella spp. by the BAX® system. The sensitivity, specificity, relative accuracy, positive predictive value, and negative predictive value obtained in the first part of this study were 100%, 92.3%, 96.4%, 53.3% and 100%, respectively. The BAX® system showed no false-negative results and reduced the time to obtain presumptive positive results. It is a suitable method for use in laboratories that perform a large number of food samples analyses daily. However, the conventional method is still required to confirm the presence of Salmonella spp. in samples that test positive using the BAX® system.
Resumo:
PCR-based technique for GMO detection is the most reliable choice because of its high sensitivity and specificity. As a candidate of the European Union, Turkey must comply with the rules for launching into the market, traceability, and labeling of GMOs as established by EU legislation. Therefore, the objective of this study is to assess soybean products in the Turkish market to verify compliance with legislation using qualitative Polymerase Chain Reaction (PCR) assay to detect the presence of GM soybean and to quantify its amount of GM soybean in the samples tested positive using real-time PCR. DNA extracted by the modified CTAB method was properly used for PCR amplification of food materials. The amplification of a 118 bp DNA fragment of the lectin gene from soybean by PCR was successfully achieved in all samples. The GMO screening was based on the detection of 35S promoter and NOS terminator sequences. The GM positive samples were subjected to detection of Roundup ReadyTM soybean (RR) using quantitative real-time PCR. It was found that 100% of the tested food samples contained less than 0.1 per cent of EPSPS gene.