157 resultados para Congenital aortic valve stenosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate prior mitral surgical commissurotomy and echocardiographic score influence on the outcomes and complications of percutaneous mitral balloon valvuloplasty. METHODS: We performed 459 complete mitral valvuloplasty procedures. Four hundred thirteen were primary valvuloplasty and 46 were in patients who had undergone prior surgical commissurotomy. The prior commissurotomy group was older, had higher echo scores, and a tendency toward a higher percentage of atrial fibrillation. RESULTS: When the groups were compared with each other, no differences were found in pre- and postprocedure mean pulmonary artery pressure, mean mitral gradient, mitral valve area, and mitral regurgitation . Because we found no significant differences, we subdivided the entire group based on echo scores, those with echo scores <=8 and those with echo scores >8 the mitral valve area being higher in the <=8 echo score group 2.06±0.42 versus 1.90±0.40cm² (p=0.0090) in the >8 echo score group. CONCLUSION: Dividing the groups based on echo score revealed that the higher echo score group had smaller mitral valve areas postvalvuloplasty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report the role played by transesophageal echocardiography during implantation of self-expanding aortic endoprostheses (stent) at a hemodynamics laboratory. METHODS: Thirteen patients underwent stent implantation in the descending thoracic aorta with the aid of transesophageal echocardiography during the entire procedure. Indications for stenting were as follows: 8 aortic dissections, 2 true aneurysms, 2 penetrating atherosclerotic ulcers, and 1 traumatic pseudoaneurysm. RESULTS: No complications resulting from the use of transesophageal echocardiography were observed. In 12 patients, the initial result was considered appropriate, with total or partial resolution of the major lesion confirmed by a posterior examination. In 1 patient, the procedure was suspended after transesophageal echocardiography and angiography showed that the proximal aortic diameter was inappropriate. Transesophageal echocardiography contributed to clarifying relevant points, such as aortic diameter, anatomic detail of the intimal lesion, and location and size of the communicating orifice. In addition, it facilitated placing the stent in the target lesion, reduced the time of exposure to radiation and the use of contrast medium, and provided rapid identification of intercurrent events, possibly reducing the total duration of the procedure. CONCLUSION: The use of transesophageal echocardiography during placement of aortic stents seems appropriate. The actual advantages of the procedure will be defined in a comparative prospective study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 44-year-old woman had a transient ischemic stroke, fibroelastoma of the mitral valve being the source of the embolus. The patient evolved with neutropenia induced by ticlopidine after 10 days of treatment. We report the major clinical features, therapeutical options, and medicamentous toxicity resulting from the use of antiplatelet drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the immediate results of percutaneous mechanical mitral commissurotomy. METHODS: Thirty patients underwent percutaneous mechanical mitral commissurotomy performed with a Cribier's metallic valvulotome from 8/11/99 to 2/4/00. Mean age was 30.7 years, and 73.3% were women. With regards to functional class, 63.3% were class III, and 36.7% were class IV. The echocardiographic score had a mean value of 7.5± 1.8. RESULTS: The mitral valve area increased from 0.97±0.15cm² to 2.16±0.50cm² (p>0.0001). The mean diastolic gradient decreased from 17.9±5.0mmHg to 3.2±1.4mmHg. The mean left atrial pressure decreased from 23.6±5.4mmHg to 8.6±3.1mmHg, (p>0.0001). Systolic pressure in the pulmonary artery decreased from 52.7±18.3mmHg to 32.2±7.4mmHg. Twenty-nine cases were successful. One patient developed severe mitral regurgitation. Interatrial septal defect was observed and one patient. One patient had cardiac tamponade due to left ventricular perforation. No deaths occurred. CONCLUSION: This method has proven to be safe and efficient in the treatment of rheumatic mitral stenosis. The potential advantage is that it can be used multiple times after sterilization, which decreases procedural costs significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate elastic properties of conduit arteries in asymptomatic patients who have severe chronic aortic regurgitation. METHODS: Twelve healthy volunteers aged 30±1 years (control group) and 14 asymptomatic patients with severe aortic regurgitation aged 29±2 years and left ventricular ejection fraction of 0.61±0.02 (radioisotope ventriculography) were studied. High-resolution ultrasonography was performed to measure the systolic and diastolic diameters of the common carotid artery. Simultaneous measurement of blood pressure enabled the calculation of arterial compliance and distensibility. RESULTS: No differences were observed between patients with aortic regurgitation and the control group concerning age, sex, body surface, and mean blood pressure. Pulse pressure was significantly higher in the aortic regurgitation group compared with that in the control group (78±3 versus 48±1mmHg, P<0.01). Arterial compliance and distensibility were significantly greater in the aortic regurgitation group compared with that in the control group (11.0±0.8 versus 8.1±0.7 10-10 N-1 m4, P=0.01 e and 39.3±2.6 versus 31.1±2.0 10-6 N-1 m², P=0.02, respectively). CONCLUSION: Patients with chronic aortic regurgitation have increased arterial distensibility. Greater vascular compliance, to lessen the impact of systolic volume ejected into conduit arteries, represents a compensatory mechanism in left ventricular and arterial system coupling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report new percutaneous techniques for perforating the pulmonary valve in pulmonary atresia with intact ventricular septum, in 3 newborns who had this birth defect. There was mild to moderate hypoplastic right ventricle, a patent infundibulum, and no coronary-cavitary communications. We succeeded in all cases, and no complications related to the procedure occurred. The new coaxial radiofrequency system was easy to handle, which simplified the procedure. Two patients required an additional source of pulmonary flow (Blalock-Taussig shunt) in the first week after catheterization. All patients had a satisfactory short-term clinical evolution and will undergo recatheterization within 1 year to define the next therapeutic strategy. We conclude that this technique may be safely and efficiently performed, especially when the new coaxial radiofrequency system is used, and it may become the initial treatment of choice in select neonates with pulmonary atresia and intact ventricular septum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a 27-year-old male patient with dyspnea on physical exertion. Clinical assessment and various tests led to the diagnosis of aortopulmonary window and double aortic arch. According to a literature search, this may be the first report on such association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study evaluated the effects of a new method of mitral valve replacement on left ventricular (LV) remodeling and heart failure functional class. METHODS: Eight patients (6 men) with severe mitral regurgitation from end-stage dilated cardiomyopathy underwent surgery. Five patients were in functional class (FC) IV, 2 were in FC III and 1 was in FC III/IV. Age ranged from 33 to 63 years. Both the anterior and posterior leaflets of the mitral valve were divided into hemileaflets. The resultant 4 pedicles were displaced under traction toward the left atrium and anchored between the mitral annulus and an implanted valvular prosthesis. The beating heart facilitated ideal chordae tendineae positioning. RESULTS: All patients survived and were discharged from the hospital. After a mean follow-up period of 6.5 months (1-12 m), 5 patients were in FC I; 2 in FC I/II; and 1 in FC II. The preoperative ejection fraction ranged from 19% to 30% (mean: 25.7±3.4 %), and the postoperative ejection fraction ranged from 21% to 40% (mean: 31.1± 5.8%). Doppler echocardiography showed evidence of LV remodeling in 4 patients, including lateral wall changes and a tendency of the LV cavity to return to its elliptical shape. CONCLUSION: This technique of mitral valve replacement, involving new positioning of the chordae tendineae, allowed LV remodeling and improvement in FC during this brief follow-up period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the occurrence of late thromboembolism after surgical repair of chronic atrial fibrillation (AF) simultaneously with repair of mitral valve using the Cox-Maze procedure. METHODS: 69 patients underwent Cox 3 procedure, with no cryoablation simultaneously with mitral valvuloplasty or prosthesis. Mean age was 49.9±13.2 years. Mean follow-up was of 31.7±19 months. Types of lesion were as follows: 33 (48%) stenoses, 23 (33%) insufficiencies, and 13 (19%) double lesions. Procedures were: 64 (93%) valvuloplasties, 3 (4%) biological and 2 (3%) mechanical prosthesis placement. There were 9 (13%) patients with previous systemic embolism and 2 (3%) had left atrial thrombi. RESULTS: Early mortality was 7% and late 1%. 2 patients (3%) were reoperated for mitral placement. At last evaluation, 10 patients (15%), were in AF. The remaining 59 (85%) were either in sinus / atrial rythm (74%) or under pacing (12%). There were no occurrence of early or late, systemic or pulmonary embolism. Permanent anticoagulation was employed in 16 cases, 10 in regular rythm and 6 in AF. The remaining 47 (75%), 2 in AF and 45 in regular rythm, did not receive anticoagulants. CONCLUSIONS: These results are in accordance with others series, where the occurrence of embolism was rare after maze procedure. Permanent systemic anticoagulation seems to be unnecessary in those cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify the left inferior pulmonary vein as an indirect marker of increased pulmonary flow in congenital heart diseases.METHODS: We carried out a prospective consecutive study on 40 patients divided into 2 groups as follows: G1 - 20 patients diagnosed with congenital heart disease and increased pulmonary flow; G2 (control group) - 20 patients who were either healthy or had congenital heart disease with decreased or normal pulmonary flow. We obtained the velocity-time integral of the left inferior pulmonary vein flow, excluding the "reverse A" wave, with pulsed Doppler echocardiography.RESULTS: In G1, 19 out of the 20 patients had well-identified dilation of the left inferior pulmonary vein. No G2 patient had dilation of the left inferior pulmonary vein. Dilation of the left inferior pulmonary vein in conditions of increased pulmonary flow had sensitivity of 95%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 95% (1 false-negative case). The integral of time and velocity of the pulmonary venous flow obtained with pulsed Doppler echocardiography was greater in the G1 patients (G1=25.0±4.6 cm versus G2=14.8±2.1 cm, p=0.0001).CONCLUSION: The identification of dilation of the left inferior pulmonary vein suggests the presence of congenital heart disease with increased pulmonary flow. This may be used as an indirect sign of increased flow, mainly in malformations of difficult diagnosis, such as atrial septal defects of the venous sinus or coronary sinus type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze hemodynamic and metabolic effects of saline solution infusion in the maintenance of blood volume in ischemia-reperfusion syndrome during temporary abdominal aortic occlusion in dogs. METHODS: We studied 20 dogs divided into 2 groups: the ischemia-reperfusion group (IRG, n=10) and the ischemia-reperfusion group with saline solution infusion aiming at maintaining mean pulmonary arterial wedge pressure between 10 and 20 mmHg (IRG-SS, n=10). All animals were anesthetized with sodium thiopental and maintained on spontaneous ventilation. Occlusion of the supraceliac aorta was obtained with inflation of a Fogarty catheter inserted through the femoral artery. After 60 minutes of ischemia, the balloon was deflated, and the animals were observed for another 60 minutes of reperfusion. RESULTS: IRG-SS dogs did not have hemodynamic instability after aortic unclamping, and the mean systemic blood pressure and heart rate were maintained. However, acidosis worsened, which was documented by a greater reduction of arterial pH that occurred especially due to the absence of a respiratory response to metabolic acidosis that was greater with the adoption of this procedure. CONCLUSION: Saline solution infusion to maintain blood volume avoided hemodynamic instability after aortic unclamping. This procedure, however, caused worsening in metabolic acidosis in this experimental model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate whether patients with heart valve prostheses and similar International Normalized Ratios (INR) have the same level of protection against thromboembolic events, that is, whether the anticoagulation intensity is related to the intensity of hypercoagulability supression. METHODS: INR and plasma levels of prothrombin fragment 1+2 (F1+2) were assessed in blood samples of 27 patients (7 with mechanical heart valves and 20 with biological heart valves) and 27 blood samples from healthy donors that were not taking any medication. RESULTS: Increased levels of F1+2 were observed in blood samples of 5 patients with heart valve prostheses taking warfarin. These findings reinforce the idea that even though patients may have INRs, within the therapeutic spectrum, they are not free from new thromboembolic events. CONCLUSION: Determination of the hypercoagulability marker F1+2 might result in greater efficacy and safety for the use of oral anticoagulants, resulting in improved quality of life for patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rupture of the left ventricle following mitral valve replacement is a catastrophic complication with deadly consequences. We report here the case of a 75-year-old man who underwent elective mitral valve replacement for severe mitral regurgitation. Delayed type 1 rupture of the left ventricle developed 3 hours postoperatively in the intensive care unit. A salvaging maneuver was used, which gained time, allowing reoperation and successful intraventricular repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess right ventricular diastolic function in the intermediate postoperative period of repair of tetralogy of Fallot. METHODS: We carried out a case-control study with 60 patients divided into 2 groups as follows: 1) group I - 30 patients who had undergone repair of tetralogy of Fallot and 2) group II - 30 healthy children. The 2 groups were paired for age, sex, and body surface. The flows in the pulmonary and tricuspid valves were analyzed with Doppler echocardiography. The presence of anterograde flow at the end of diastole in the pulmonary artery defined restrictive right ventricular physiology. Surgical, radiological, electrocardiographic, and echocardiographic variables were analized in the group I. RESULTS: The velocity of the A wave and the E/A ratio for the tricuspid valve showed significant differences between the groups. Cases with E/A < 1.30 predominated in inspiration (group I - 19/30, and group II - 5/30). The duration of the QRS complex on the electrocardiogram was significantly increased in patients with E/A <1.30. Nineteen (63.3%) patients had restrictive right ventricular physiology, which had a longer postoperative period, longer duration of the QRS complex, and a lower E/A ratio in inspiration. The surgical and radiological variables showed no statistical difference. CONCLUSION: Restrictive right ventricular physiology was detected on the intermediate follow-up of most patients undergoing repair of tetralogy of Fallot. The postoperative period and QRS duration were increased in patients with impairment in diastolic function.