146 resultados para Cerebrospinal fluid shunts
Resumo:
Toxoplasmosis is one of the most common infections all over the world. Most cases are asymptomatic, except in immunosuppressed individuals and fetuses, which can be seriously damaged. Prenatal diagnosis should be made as soon as possible since treatment of the mother can minimize fetal sequelae. Our aim in this study was to test the polymerase chain reaction technique (PCR) in 86 samples of amniotic fluid from women who seroconverted during pregnancy. DNA was amplified using external primers and, in a second step, internal primers, in a nested PCR system. Samples were also inoculated into mice and the newborn were evaluated by T. gondii serology, skull x-ray, transfontanel ultrasound, fundoscopic examination, lumbar puncture and clinical examination. PCR was positive in seven cases and negative in 79. Among PCR-positive cases, two were negative by inoculation into mice and by clinical evaluation; among PCR-negative ones, three had clinical evidence of toxoplasmosis and one was positive after inoculation into mice. PCR showed values of sensitivity = 62.5% and specificity = 97.4%; the values of inoculation into mice where 42.9% and 100%, respectively. Although PCR should not be used alone for prenatal diagnosis of congenital toxoplasmosis, it is a promising method and deserves more studies to improve its efficacy.
Resumo:
Introduction Toxoplasmosis may be life-threatening in fetuses and in immune-deficient patients. Conventional laboratory diagnosis of toxoplasmosis is based on the presence of IgM and IgG anti-Toxoplasma gondii antibodies; however, molecular techniques have emerged as alternative tools due to their increased sensitivity. The aim of this study was to compare the performance of 4 PCR-based methods for the laboratory diagnosis of toxoplasmosis. One hundred pregnant women who seroconverted during pregnancy were included in the study. The definition of cases was based on a 12-month follow-up of the infants. Methods Amniotic fluid samples were submitted to DNA extraction and amplification by the following 4 Toxoplasma techniques performed with parasite B1 gene primers: conventional PCR, nested-PCR, multiplex-nested-PCR, and real-time PCR. Seven parameters were analyzed, sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), negative likelihood ratio (NLR) and efficiency (Ef). Results Fifty-nine of the 100 infants had toxoplasmosis; 42 (71.2%) had IgM antibodies at birth but were asymptomatic, and the remaining 17 cases had non-detectable IgM antibodies but high IgG antibody titers that were associated with retinochoroiditis in 8 (13.5%) cases, abnormal cranial ultrasound in 5 (8.5%) cases, and signs/symptoms suggestive of infection in 4 (6.8%) cases. The conventional PCR assay detected 50 cases (9 false-negatives), nested-PCR detected 58 cases (1 false-negative and 4 false-positives), multiplex-nested-PCR detected 57 cases (2 false-negatives), and real-time-PCR detected 58 cases (1 false-negative). Conclusions The real-time PCR assay was the best-performing technique based on the parameters of Se (98.3%), Sp (100%), PPV (100%), NPV (97.6%), PLR (∞), NLR (0.017), and Ef (99%).
Resumo:
Introduction The aim of this study was to explore the environment of Echinococcus granulosus (E. granulosus) protoscolices and their relationship with their host. Methods Proteins from the hydatid-cyst fluid (HCF) from E. granulosus were identified by proteomics. An inductively coupled plasma atomic emission spectrometer (ICP-AES) was used to determine the elements, an automatic biochemical analyzer was used to detect the types and levels of biochemical indices, and an automatic amino acid analyzer was used to detect the types and levels of amino acids in the E. granulosus HCF. Results I) Approximately 30 protein spots and 21 peptide mass fingerprints (PMF) were acquired in the two-dimensional gel electrophoresis (2-DE) pattern of hydatid fluid; II) We detected 10 chemical elements in the cyst fluid, including sodium, potassium, calcium, magnesium, copper, and zinc; III) We measured 19 biochemical metabolites in the cyst fluid, and the amount of most of these metabolites was lower than that in normal human serum; IV) We detected 17 free amino acids and measured some of these, including alanine, glycine, and valine. Conclusions We identified and measured many chemical components of the cyst fluid, providing a theoretical basis for developing new drugs to prevent and treat hydatid disease by inhibiting or blocking nutrition, metabolism, and other functions of the pathogen.
Resumo:
Prolonged total food deprivation in non-obese adults is rare, and few studies have documented body composition changes in this setting. In a group of eight hunger strikers who refused alimentation for 43 days, water and energy compartments were estimated, aiming to assess the impact of progressive starvation. Measurements included body mass index (BMI), triceps skinfold (TSF), arm muscle circumference (AMC), and bioimpedance (BIA) determinations of water, fat, lean body mass (LBM), and total resistance. Indirect calorimetry was also performed in one occasion. The age of the group was 43.3±6.2 years (seven males, one female). Only water, intermittent vitamins and electrolytes were ingested, and average weight loss reached 17.9%. On the last two days of the fast (43rd-44th day) rapid intravenous fluid, electrolyte, and vitamin replenishment were provided before proceeding with realimentation. Body fat decreased approximately 60% (BIA and TSF), whereas BMI reduced only 18%. Initial fat was estimated by BIA as 52.2±5.4% of body weight, and even on the 43rd day it was still measured as 19.7±3.8% of weight. TSF findings were much lower and commensurate with other anthropometric results. Water was comparatively low with high total resistance, and these findings rapidly reversed upon the intravenous rapid hydration. At the end of the starvation period, BMI (21.5±2.6 kg/m²) and most anthropometric determinations were still acceptable, suggesting efficient energy and muscle conservation. Conclusions: 1) All compartments diminished during fasting, but body fat was by far the most affected; 2) Total water was low and total body resistance comparatively elevated, but these findings rapidly reversed upon rehydration; 3) Exaggerated fat percentage estimates from BIA tests and simultaneous increase in lean body mass estimates suggested that this method was inappropriate for assessing energy compartments in the studied population; 4) Patients were not morphologically malnourished after 43 days of fasting; however, the prognostic impact of other impairments was not considered in this analysis.
Resumo:
OBJECTIVE: Macrolide antibiotics have anti-inflammatory properties in lung diseases. The aim of this study was to investigate the effect of clarithromycin in pulmonary cellular inflammatory response in mice. METHOD: Eight adult Swiss mice were studied. All animals received an intranasal challenge (80 µL) with dead Pseudomonas aeruginosa (1.0 x 10(12) CFU/mL). Bronchoalveolar lavage was performed 2 days later, with total cell count and differential cell analysis. The study group (n = 4) received clarithromycin treatment (50 mg/kg/day, intraperitoneal) for 5 days. Treatment was initiated 2 days before intranasal challenge. RESULTS: There was no significant difference in total cell count between the groups (mean: 2.0 x 10(6) and 1.3 x 10(6), respectively). In both groups, there was a predominance of neutrophils. However, the study group had a higher percentage of lymphocytes in the bronchoalveolar lavage than the control group (median of 19% vs 2.5%, P = .029). CONCLUSION: Clarithromycin alters the cytological pattern of bronchoalveolar lavage of Swiss mice with neutrophil pulmonary inflammation, significantly increasing the percentage of lymphocytes.
Resumo:
The purpose of this study was to examine the circulating filarial antigen (CFA) detected by the monoclonal antibody (mAb) Og4C3-ELISA in paired samples of serum and hydrocele fluid from 104 men with hydrocele, living in an endemic area of Wuchereria bancrofti. Nocturnal blood specimens were filtered and examined for microfilariae (MF) and ultrasound was used in order to identify the presence of adult worms (the filaria dance sign - FDS) in the lymphatic vessels of the scrotal area. Four groups were selected according to their parasitological status: group I - 71 MF- and FDS-; group II - 21 MF+ and FDS+; group III - 10 MF- and FDS+ and group IV- 2 MF+ and FDS-. CFA was identified simultaneously (fluid and serum) in 11 (15.5%), 21 (100%), 3 (30%), and 1 (50%) in groups I, II, III, and IV, respectively. In despite of high CFA+ level (antigen Og4C3) units/ml, the Geometrical Mean (GM) = 2696) in the sera of these 36/104 paired samples, when compared to the hydrocele fluid, (GM = 1079), showed a very good correlation between the CFA level in the serum and CFA level in the fluid (r = 0.731). CFA level in the serum of the 23 microfilaremics (groups II and IV) was extremely high (GM = 4189) and was correlated with MF density (r = 0.442). These findings report for the first time the potential alternative use of the hydrocele fluid to investigate CFA using the mAb Og4C3-ELISA.
Resumo:
In this report, we examine the adaptability of commercially available serological kits to detect antibodies markers for viral hepatitis in oral fluid samples. We also assessed the prevalence of hepatitis A, B, and C virus-specific antibodies, and related risk factors for these infectious diseases through sensitivity of the tests in saliva samples to evaluate if oral fluid can be an alternative tool to substitute serum in diagnosis of acute viral hepatitis and in epidemiological studies. One hundred and ten paired serum and saliva specimens from suspect patients of having acute hepatitis were collected to detect antibodies to hepatitis A (total and IgM), hepatitis B (anti-HBs, total anti-HBc and IgM anti-HBc), and hepatitis C (anti-HCV) using commercially available enzyme-linked immunossorbent assay (EIA). In relation to serum samples, oral fluid assay sensitivity and specificity were as follows: 87 and 100% for total anti-HAV, 79 and 100% for anti-HAV IgM, 6 and 95% for anti-HBs, 13 and 100% for total anti-HBc, 100 and 100% for anti-HBc IgM, and 75 and 100% for anti-HCV. The consistency observed between antibodies tests in saliva and expected risk factors for hepatitis A and C suggests that the saliva method could replace serum in epidemiological studies for hepatitis A and C.
Resumo:
This study is aimed at evaluating the potential to detect human immunodeficiency virus (HIV) in amniotic fluid (AF) collected at delivery from 40 HIV-positive pregnant women. Thirty patients had a plasma viral load (VL) below 1,000 copies/mL at delivery. VL was positive in three AF samples. No significant association was found between the HIV-1 RNA in AF and the maternal plasma samples. There was no HIV vertical transmission detected.
Resumo:
Objective: To identify the prevalence of nursing diagnosis of fluid volume excess and their defining characteristics in hemodialysis patients and the association between them. Method: Cross-sectional study conducted in two steps. We interviewed 100 patients between the months of December 2012 and April 2013 in a teaching hospital and one hemodialysis clinic. The inference was performed by diagnostician nurses between July and September 2013. Results: The diagnostic studied was identified in 82% of patients. The characteristics that were statistically associated: bounding pulses, pulmonary congestion, jugular vein distention, edema, change in electrolytes, weight gain, intake greater than output and abnormal breath sounds. Among these, edema and weight gain had the highest chances for the development of this diagnostic. Conclusion: The analyzed diagnostic is prevalent in this population and eight characteristics presented significant association.
Resumo:
Supercritical fluid extraction was used to extract active compounds from the Chinese traditional medicinal D. dasycarpus under the pressure of 30 MPa and temperature of 45 ºC. Further separation and purification was established by high-speed counter-current chromatography (HSCCC) with a two-phase solvent system composed of n-hexane-ethyl acetate-methanol-water (1:0.8:1.3:0.9, volume ratio). The separation yielded a total of 47 mg of dictamnine, 24 mg of obacunone and 83 mg of fraxinellone from 1.0 g of the crude extract in one step separation with the purity of 99.2, 98.4 and 99.0%, respectively, as determined by HPLC. The chemical structures of these compounds were identified by ESI-MS, IR, ¹H-NMR and 13C-NMR.
Resumo:
Maceration and supercritical fluid extraction were used to prepare extracts from parts of plants (Holostylis reniformis) collected in two different regions of Brazil. ¹H NMR, HPLC-DAD-ESI/MS, HPLC-DAD, GC-MS, and chemometric techniques were used to analyse lignans in the extracts and showed that yields of SFE-CO2 were less than or equal to those of hexane maceration extracts. These analyses, in conjunction with the concentrations of aliphatic hydrocarbons, fatty acids and their methyl and ethyl derivatives in the extracts, also allowed the chemical composition of parts and provenance of the plant to be differentiated.
Resumo:
Separations using supercritical fluid chromatography (SFC) with packed columns have been re-discovered and explored in recent years. SFC enables fast and efficient separations and, in some cases, gives better results than high performance liquid chromatography (HPLC). This paper provides an overview of recent advances in SFC separations using packed columns for both achiral and chiral separations. The most important types of stationary phases used in SFC are discussed as well as the most critical parameters involved in the separations and some recent applications.
Resumo:
PURPOSE: To verify the predictors of intravasation rate during hysteroscopy.METHODS: Prospective observational study (Canadian Task Force classification II-1). All cases (n=200 women; 22 to 86 years old) were treated in an operating room setting. Considering respective bag overfill to calculate water balance, we tested two multiple linear regression models: one for total intravasation (mL) and the other for absorption rate (mL.min-1). The predictors tested (independent variables) were energy (mono/bipolar), tube patency (with/without tubal ligation), hysterometry (cm), age≤50 years, body surface area (m2), surgical complexity (with/without myomectomy) and duration (min).RESULTS: Mean intravasation was significantly higher when myomectomy was performed (442±616 versus 223±332 mL; p<0.01). In the proposed multiple linear regression models for total intravasation (adjusted R2=0.44; p<0.01), the only significant predictors were myomectomy and duration (p<0.01).In the proposed model for intravasation rate (R2=0.39; p<0.01), only myomectomy and hysterometry were significant predictors (p=0.02 and p<0.01, respectively).CONCLUSIONS: Not only myomectomy but also hysterometry were significant predictors of intravasation rate during operative hysteroscopy.
Resumo:
Intestinal devitalization in cases of small colon obstruction may be difficult to detect based only in clinical signs. The purpose was to serially evaluate blood and peritoneal fluid of horses subjected to small colon distension. Seventeen adult horses were allotted in three groups. In the small colon-distended group (DG, n=7) a surgically-implanted latex balloon was inflated to promote intraluminal small colon distension. In the shamoperated group (SG, n=5), the balloon was implanted but not inflated, and no surgery was done in the control group (CG, n=5). Blood and peritoneal fluid were sampled before and after (6 samples with a 30-minute interval) intestinal obstruction for cytological and biochemical analyses. No significant changes in clinical signs occurred within groups or across time during the experimental period. There were no statistical differences among SG and SG groups in hematologic and blood chemistry variables. Although total protein concentration and lactate dehydrogenase (LDH) activity in peritoneal fluid remained most of the time within reference values during the experimental period in all groups, increases from baseline values were detected in SG and DG groups. Such increases occurred earlier, progressively and with greater magnitude in the DG when compared with the SG (P<0.05). Increases from baselines values were also observed in total nucleated cells and neutrophils counts in the DG (P<0.05). In conclusion, distension of the equine small colon induced progressive subtle increases in total protein and LDH concentrations in the peritoneal fluid during the first hours. Serial evaluation of these variables in peritoneal fluid may be useful for early detection of intestinal devitalization in clinical cases of equine small colon obstruction.