175 resultados para Éguas receptoras acíclicas


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water pollution is a serious environmental problem. In Rondinha, Rio Grande do Sul, on a small area planted with tobacco, it has been using organophosphates pesticides. The purpose of this study was to evaluate the organophosphates pesticides contamination of the superficial water in this municipality. The samples collected in fifteen places were evaluated by the method of organophosphates acethylcolinestherase inhibition. In five samples the organophosphates levels were above the limit established by CONAMA, indicating the necessity of arrangements that allow reducing the risk of the population and the environment contamination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrogen peroxide and chlorine are compared as possible disinfectants for water-cooling circuits. To this purpose, samples taken from the cooling system of a steel making plant were treated (at 25ºC and pH values of 5.5 and 8.5) with varying amounts of the two oxidizing agents (0.0 mg/L, 2.0 mg/L and 6.0 mg/L). The results were evaluated through bacterial counting and measurement of corrosion rates upon AISI1020 carbon steel coupons. Bacterial removal and corrosion effects proved to be similar and satisfactory for both reagents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pesticides can be quite useful in agricultural production, however, some pesticides after application can reach and contaminate the hydric resource. Pesticide monitoring must be careful because it is expensive and lengthy. Thus, in this work, a theoretical prediction was made using the approaches suggested by EPA-USA, the Groundwater Ubiquity Score index (GUS) and the Goss method associated with physicochemical properties of 27 pesticides used in a region in the south of Brazil. The results of this work led to the identification of the pesticides that should be prioritized in the environmental monitoring due to their high potential for contaminating water resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the spatial and temporal variations of 13 physico-chemical parameters in water and sediment samples collected along the rural and urban section of Verruga Stream. The metal concentrations were determined by FAAS. The conductivity and the concentration of Na+, Cl-, and Ca2+ showed the largest variations in the urban area demonstrating that these parameters are appropriate indicators of urban contamination. The application of cluster and principal component analysis showed that the Cd2+ and Mn2+ are associated with the use of fertilizers in the rural area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rainfall samples collected in the downtown area of São Paulo city, during 2003, exhibited average concentrations of cadmium, lead and copper of 1.33, 8.52 and 49.5 nmol L-1, respectively. Among the major ions, NH4+ was the predominant species followed by NO3-, SO4(2-) and Ca2+, with volume weighed mean (VWM) concentrations of 37.1, 20.1, 11.9 and 10.8 µmol L-1, respectively. All the determined species showed high inter-events variability, including free H+ ions whose VWM concentration was 4.03 µmol L-1, corresponding to a pH value of 5.39.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies indicated that free radicals control organic matter redox activities. In the present study, organic matter of an ultra-filtrated material collected from seven samples taken seasonally from the Paraiba do Sul River for two years were titrated with an oxidizer (I2) in an inert atmosphere. Standard formal potential values for the electrode MO Ox, MO Red ranged from 0.754 to 0.786 V at a 25 ºC temperature. Organic matter oxidation capacity (COx) per carbon mass varied according to pH values, and changes in COx were related to rainfall and river flow intensities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports an alternative, fast and robust method, for the determination of total As, As(III) and As(V) by HG-AAS without the use of prereductants. The method is based on the different rates of arsine formation of the inorganic As species and the effect of As(III) in the signal obtained for total As. Groundwater and mineral spiked waters were used to sample preservation evaluation. The method was validated by the determination of As in SRM 1640 and used in the determination of total As and its inorganic species in groundwater samples collected from mines in the Iron Quadrangle - MG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analytical laboratories are expected to produce reliable results. Decision makers are guided in their actions (financial, legal and environmental) using analytical data provided by numerous laboratories. This work aimed to evaluate the analytical performance of Brazilian laboratories on producing trustworthy results. Nineteen laboratories, accredited and non-accredited ones, were contracted to analyze a USGS (United States Geological Survey) certified water sample for 17 chemical elements (mostly metals) without knowing the origin of the sample. Considering all the results produced, only 35% of them were valid. Three laboratories present satisfactory performances, whereas the majority showed a very poor overall performance. The outcomes of this work show the need for a more effective analytical quality program to Brazilian laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A binary sampling flow analysis system equipped with gas diffusion cell was developed for NH4+ and/or NH2Cl determination in wastewater and disinfection products samples based on the Berthelot reaction of the NH2Cl diffused through the semi-permeable PTFE membrane. The effect of the analytical conditions related to the reaction and flow parameters were evaluated and N-NH4+ and N-NH2Cl were determined in concentration ranges from 0.17 to 5 mg L-1 and from 0.5 to 14.5 mg L-1, respectively. Limits of detection (3σ) of 50 and 140 µg L-1 for N-NH4+ and N-NH2Cl were calculated, respectively, and RSD of 5 and 2% were calculated for 10 consecutive determinations of N-NH4+ (1 and 3 mg L-1) and N-NH2Cl (3 and 9 mg L-1), respectively with 30 determinations h-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this manuscript, seasonal and spatial trends of water collected from two sampling places in the Preto River in the Turvo-Grande watershed were evaluated. Water samples were collected during June/07 to July/08 and parameters sulphate, total organic carbon, ammonia, conductivity, dissolved oxygen, temperature, dissolved total solids and nitrate were quantified. Seasonal trend indicated sanitary effluents as a point source of contamination in both sampling points. Vertical trends demonstrated that the Municipal Dam was not stratified and received a diffuse source of pollutants from flooding and agriculture runoffs. It was also verified that there is relatively fast ammonia consumption kinetics having a half-life time of 1.43 h which can explain the low ammonia concentrations found in these aquatic bodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oxidation of arsenic (As(III) to As(V)) in water samples was performed by heterogeneous photocatalysis using a TiO2 film immobilized inside a photochemical reactor. After oxidation, As(V) was removed from the water samples by coprecipitation with ferric sulfate. The final conditions of oxidation and arsenic removal (TiO2 film prepared with a suspension: 10% (w/v); pH: 7.0; oxidation time: 30 min and Fe3+ concentration: 50 mg L-1) were applied in natural water samples which were supplemented with 1.0 mg L-1 of As(III) to verify the influence of the matrix. After treatment, more than 99% of arsenic was removed from the water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work the potentiality of photo-Fenton processes were investigated toward the degradation of aromatic hydrocarbons (BTXs) from water contaminated with gasoline. The main results demonstrated that BTXs can be quickly degraded by photo-Fenton process assisted by solar or artificial UV-A radiation, degradation that leads to generation of characteristic phenolic transient species (ie. phenol, hydroquinone and catechol). In the treatment of contaminated water by photo-Fenton processes assisted by solar light, complete BTXs removal was observed in reaction times of about 5 min. Mineralization of about 90% was also observed by applying a multiple H2O2 addition system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this investigation antioxidant response and toxicity of metals in receiving water effluent miner in the Blanco river in Pseudokirchneriella subcapitata was assessed. The catalase activity, lipid damage through Tbars, the growth rate of was determined. The result showed an inhibition of the growth rate of P. subcapitata which correlated with increased catalase activity and the lipid liperoxidation. These responses were correlated with the concentrations of copper and iron.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A solid-phase in-line extraction system for water samples containing low levels of emerging contaminants is described. The system was specially developed for large volume samples (up to 4 L) using commercial solid-phase extraction (SPE) cartridges. Four sets containing PTFE-made connectors, brass adapters and ball valves were used to fit SPE cartridges and sample bottles to a 4-port manifold attached to a 20 L carboy. A lab-made vacuum device was connected to the manifold cap. The apparatus is robust and less expensive than the typical available system. Its also provides less experimental handling, avoiding cross contamination and sample losses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to analyze 17 β estradiol and estrone, natural estrogenic hormones present in domestic effluents and animal excreta, in the public water supply system of Jaboticabal, SP. The results have shown the presence of estrogens in 22% of the samples in concentrations from 6,8 ng L-1 (treated water) to 30,6 ng L-1 (riverhead) for 17 β estradiol and 600 ng L-1 of estrone (stream), respectively. We concluded that animal wastes, discharges from the wastewater treatment station, and discharges of domestic effluent without treatment from rural proprieties were probably the cause of this contamination.