169 resultados para Ultrasonography, Doppler, Color
Resumo:
OBJETIVO: Avaliar a reprodutibilidade intra e interobservador do Doppler de amplitude tridimensional (3D power Doppler) na avaliação do fluxo sanguíneo cerebral do território da artéria cerebral média. MATERIAIS E MÉTODOS: Foi realizado estudo transversal com 20 gestantes normais entre 26 e 34 semanas. O território da artéria cerebral média mais próximo ao transdutor foi selecionado e o volume foi calculado utilizando-se o método Virtual Organ Computer-aided AnaLysis. Posteriormente, obtiveram-se os índices do 3D power Doppler: índice de vascularização (VI), índice de fluxo (FI) e índice de vascularização-fluxo (VFI). Utilizaram-se, para os cálculos, o coeficiente de correlação intraclasse (CCI) e gráficos de Bland-Altman. RESULTADOS: Foi observada boa concordância intra e interobservador, com CCI > 0,90 para todos os índices do 3D power Doppler: VI [CCI = 0,992 (IC 95%: 0,981-0,997)], FI [CCI = 0,999 (IC 95%: 0,998-0,999)], VFI [CCI = 0,995 (IC 95%: 0,987-0,998)]. Reprodutibilidade interobservador: VI [CCI = 0,988 (IC 95%: 0,970-0,995)], FI [CCI = 0,999 (IC 95%: 0,997-1,000)], VFI [CCI = 0,994 (IC 95%: 0,994-0,998)]. CONCLUSÃO: O 3D power Doppler mostrou-se um método prático, fácil e com boa reprodutibilidade intra e interobservador, com o IF evidenciando a melhor concordância intra e interobservador
Resumo:
O divertículo de Meckel é a anomalia congênita mais comum do trato gastrintestinal e a hemorragia é a complicação mais frequente. Cintilografia, ultrassonografia modo B e com Doppler, e tomografia computadorizada podem ser utilizadas para detectar complicações. Descrevemos dois casos de divertículo de Meckel complicado detectados à ultrassonografia, cujos achados foram diferentes dos descritos na literatura.
Is there any influence of breastfeeding on the cerebral blood flow? A review of 256 healthy newborns
Resumo:
OBJECTIVE: To investigate whether breastfeeding influence the cerebral blood-flow velocity. MATERIALS AND METHODS: The present study included 256 healthy term neonates, all of them with appropriate weight for gestational age, 50.8% being female. Pulsatility index, resistance index and mean velocity were measured during breastfeeding or resting in the anterior cerebral artery, in the left middle cerebral artery, and in the right middle cerebral artery of the neonates between their first 10 and 48 hours of life. The data were analyzed by means of a paired t-test, Brieger's f-test for analysis of variance and linear regression, with p < 0.01 being accepted as statistically significant. RESULTS: Mean resistance index decreased as the mean velocity increased significantly during breastfeeding. Pulsatility index values decreased as much as the resistance index, but in the right middle cerebral artery it was not statistically significant. CONCLUSION: Breastfeeding influences the cerebral blood flow velocities.
Resumo:
Objective To compare the capacity of mammography, sonoelastography, B-mode ultrasonography and histological analysis to differentiate benign from malignant breast lesions. Materials and Methods A total of 12 histopathologically confirmed breast lesions were documented. The lesions were assessed by means of mammography, B-mode ultrasonography and sonoelastography, and histopathological analysis was utilized as a gold standard. Sensitivity and specificity were calculated. A receiver operating characteristic (ROC) curve was constructed to evaluate the diagnostic performance of the mentioned techniques. Results Sensitivity and specificity in the differentiation between benign and malignant lesions were respectively 100% and 50% for mammography, 100% and 71% for B-mode ultrasonography, and 67% and 83% for sonoelastography. The area under the ROC curve was calculated for the three imaging modalities and corresponded to 0.792 for mammography, 0.847 for B-mode ultrasonography, and 0.806 for sonoelastography. Conclusion Sonoelastography demonstrated higher specificity and lower sensitivity as compared with mammography and B-mode ultrasonography. On the other hand, B-mode ultrasonography had the largest area under the ROC curve. Sonoelastography has demonstrated to be a promising technique to detect and evaluate breast lesions, and could potentially reduce the number of unnecessary biopsies.
Resumo:
Objective To evaluate the sonographic measurement of subcutaneous and visceral fat in correlation with the grade of hepatic steatosis. Materials and Methods In the period from October 2012 to January 2013, 365 patients were evaluated. The subcutaneous and visceral fat thicknesses were measured with a convex, 3–4 MHz transducer transversely placed 1 cm above the umbilical scar. The distance between the internal aspect of the abdominal rectus muscle and the posterior aortic wall in the abdominal midline was considered for measurement of the visceral fat. Increased liver echogenicity, blurring of vascular margins and increased acoustic attenuation were the parameters considered in the quantification of hepatic steatosis. Results Steatosis was found in 38% of the study sample. In the detection of moderate to severe steatosis, the area under the ROC curve was 0.96 for women and 0.99 for men, indicating cut-off values for visceral fat thickness of 9 cm and 10 cm, respectively. Conclusion The present study evidenced the correlation between steatosis and visceral fat thickness and suggested values for visceral fat thickness to allow the differentiation of normality from risk for steatohepatitis.
Resumo:
Beckwith-Wiedemann syndrome is a genetic syndrome characterized by macroglossia, omphalocele, fetal gigantism and neonatal hypoglycemia. The authors report a case of Beckwith-Wiedemann syndrome diagnosed in a 32-year-old primigravida in whom two-dimensional ultrasonography revealed the presence of abdominal wall cyst, macroglossia and polycystic kidneys. Three-dimensional ultrasonography in rendering mode was of great importance to confirm the previous two-dimensional ultrasonography findings.
Resumo:
Objective To evaluate the association of Doppler of uterine artery and flow-mediated dilation of brachial artery (FMD) in the assessment of placental perfusion and endothelial function to predict preeclampsia. Materials and Methods A total of 91 patients considered as at risk for developing preeclampsia were recruited at the prenatal unit of the authors' institution. All the patients underwent FMD and Doppler of uterine arteries between their 24th and 28th gestational weeks. Calculations of sensitivity and specificity for both isolated and associated methods were performed. Results Nineteen out of the 91 patients developed preeclampsia, while the rest remained normotensive. Doppler flowmetry of uterine arteries with presence of bilateral protodiastolic notch had sensitivity of 63.1% and specificity of 87.5% for the prediction of preeclampsia. Considering a cutoff value of 6.5%, FMD showed sensitivity of 84.2% and specificity of 73.6%. In a parallel analysis, as the two methods were associated, sensitivity was 94.2% and specificity, 64.4%. Conclusion The association of Doppler study of uterine arteries and FMD has proved to be an interesting clinical strategy for the prediction of preeclampsia, which may represent a positive impact on prenatal care of patients considered as at high-risk for developing such a condition.
Resumo:
Uterine arteriovenous malformations may cause life-threatening abnormal genital bleeding in women at childbearing age. Transvaginal Doppler ultrasonography is a widely available, noninvasive and excellent diagnostic method. The authors report the case of a patient with history of gestational trophoblastic disease and multiple curettage procedures who developed uterine arteriovenous malformations, with remission of the lesions after treatment with methotrexate.
Resumo:
Fetal development is studied since the advent of two-dimensional ultrasonography. However, a detailed assessment of structures and surfaces improved with three-dimensional ultrasonography. Currently, it is possible to identify embryonic components and fetal parts with greater detail, at all pregnancy trimesters, using the HD live software, where the images gain realistic features by means of appropriate control of lighting and shadowing effects. In the present study, the authors utilized this resource to follow-up, by means of images, the development of a normal pregnancy along all trimesters.
Resumo:
AbstractThe present essay is aimed at getting the radiologist familiar with the basic histological skin structure, allowing for a better correlation with sonographic findings. A high-frequency (22 MHz) ultrasonography apparatus was utilized in the present study. The histological analysis was performed after the skin specimens fixation with formalin, inclusion in paraffin blocks and subsequent staining with hematoxylin-eosin. The authors present a literature review showing the relationship between sonographic and histological findings in normal cutaneous tissue, and discuss the technique for a better performance of the sonographic scan. High-frequency ultrasonography is an excellent tool for the diagnosis of different skin conditions. However, as this method is operator-dependent, it is crucial to understand the normal skin structure as well as the correlation between histological and sonographic findings.
Resumo:
We are working in a new multi-doped glassy material to generate simultaneously the three primary light color (by addition) of the visible spectrum, with the control of the intensity of each one, allowing the simulation of any color: a full-color generator device. Tm+3, Tb+3 and Eu+3 ions were used (0.01 to 5,0 mol%) as blue, green and red narrow line emitters. A wide color gamut was obtained under ultraviolet excitation by varying the material composition. The chromaticity diagram is covered, including the white simulation.
Resumo:
Fourier transform infrared attenuated total reflectance (FT-IR ATR) spectroscopy was used to determine 14 different measurands in northeast Brazilian honey samples. Nine different honey samples (six monofloral and three polyfloral) from 2009 obtained from the company CEARAPI underwent FT-IR ATR, palynological, color, and sensorial analysis to obtain preliminary results for these types of honey. The results showed that there are five monofloral, three bifloral, and one extrafloral honey, and also that mid-infrared spectrometry can be used as a screening method for the routine analysis of Brazilian honey, with the advantages of being rapid, nondestructive, and accurate.
Resumo:
This study aimed at evaluating the effects of ethylene on peel color and compositional changes in ‘Lane late’ orange stored under refrigerated and ambient conditions. Physiologically mature, but green-peeled, oranges were exposed to ethylene gas under room temperature and high relative humidity for 24 hours. Storage chamber was ventilated with fresh air after 12 hours to mitigate consequences derived from fruit respiration. Both nondestructive analysis, such as peel color (hue angle, chromaticity, and brightness) and weight loss, and destructive ones (soluble solids, titratable acidity, pH, soluble solids to acidity ratio, and puncture force) were performed upon harvest, after degreening, and every three days during eighteen days in storage. Experiment was carried out using an entirely randomized design with thirty replications for nondestructive and four replications for destructive analyses, in a split plot scheme. Exposure to ethylene ensured a golden yellow peel for both fruit stored under ambient and refrigerated conditions. High relative humidity, associated with low temperature prevented fruit from losing moisture. Fruit exposure to ethylene did not affect weight loss, soluble solids, titratable acidity, pH, soluble solids, acidity ratio, or puncture force.
Resumo:
Living related liver transplantation is being increasingly used for patients that can not wait for a cadaveric organ. We describe a case of a right lobe donor who had a type III portal vein anomaly. On this anomaly the portal vein gives branches first to the right posterior vein and then to the right anterior vein and the left portal vein. The recipient had portal vein thrombosis that was recognized only during the surgery. The Doppler examination performed before the operation did not detect this thrombosis. The transplant was not accomplished. Anatomical anomaly of the portal vein may be a rare cause impossibility to organ donation in living related liver transplantation.