200 resultados para Tridimensional echocardiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVE: To evaluate by Doppler echocardiography (DE) early abnormalities of ventricular function in HIV-positive patients, as well as other cardiac abnormalities that can be detected by this method, with special emphasis on mitral valve flow. METHODS: 84 HIV- positive patients, 59 with CD4 cell count >500/mm³ (Group A) and 25 with CD4 cell count <500/mm³ (Group B), were analyzed. CD4 cells were counted and matched with structural data and systolic and diastolic function of the left ventricle (LV), as analyzed by DE. The results were compared with those obtained in 47 healthy individuals (Group C). RESULTS: 8% of patients in Group B had mild pericardial effusion; 31.5% showed decreased systolic function of the LV, and 12% had moderate mitral regurgitation. A wave velocity from the mitral inflow was different among the 3 groups, being higher in Group B, where the deceleration time of the E wave of the mitral inflow and the E/A ratio were significantly lower with a normal value of the isovolumic relaxation time (IVRT). CONCLUSION: HIV-positive patients with a CD4 cell count >500/mm³ had no abnormalities by DE. Patients with a more advanced infection (those with a CD4 cell count <500/mm³), had a significantly abnormal LV systolic function and a higher incidence of pericardial effusion and mitral regurgitation. Mitral valve inflow by Doppler did not indicate diastolic dysfunction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the changes in ventricular evoked responses (VER) produced by the decrease in left ventricular outflow tract gradient (LVOTG) in patients with hypertrophic obstructive cardiomyopathy (HOCM) treated with dual-chamber (DDD) pacing. METHODS: A pulse generator Physios CTM (Biotronik, Germany) was implanted in 9 patients with severe drug-refractory HOCM. After implantation, the following conditions were assessed: 1) Baseline evaluation: different AV delay (ranging from 150ms to 50 ms) were sequentially programmed during 5 to 10 minutes, and the LVOTG (as determined by Doppler echocardiography) and VER recorded; 2) standard evaluation, when the best AV delay (resulting in the lowest LVOTG) programmed at the initial evaluation was maintained so that its effect on VER and LVOTG could be assessed during each chronic pacing evaluation. RESULTS: LVOTG decreased after DDD pacing, with a mean value of 59 ± 24 mmHg after dual chamber pacemaker, which was significantly less than the gradient before pacing (98 + 22mmHg). An AV delay >100ms produced a significantly lower decrease in VER depolarization duration (VER DD) when compared to an AV delay <=100ms. Linear regression analyses showed a significant correlation between the LVOTG values and the magnitude of VER (r=0.69; p<0.05) in the 9 studied patients. CONCLUSION: The telemetry obtained intramyocardial electrogram is a sensitive means to assess left ventricular dynamics in patients with HOCM treated with DDD pacing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Anatomical and functional assessment of the heart through Doppler and echocardiography in patients with cell anemia (SCA). METHODS: Twenty-five patients with SCA and ages ranging from 14 to 45 years were prospectively studied in a comparison with 25 healthy volunteers. All of them underwent clinical and laboratory evaluation and Doppler echocardiography as well.The measurements were converted into body surface indices. RESULTS: There were increases in all chamber diameters and left ventricle (LV) mass of the SCA patients. It was characterised an eccentric hypertrophy of the left ventricle. The preload was increased (left ventricle end-diastolic volume) and the afterload was decreased (diastolic blood pressure, peripheral vascular resistance and end-systolic parietal stress ESPS). The cardiac index was increased due to the stroke volume. The ejection fraction and the percentage of the systolic shortening , as well as the systolic time intervals of the LV were equivalent. The isovolumetric contraction period of the LV was increased. The mitral E-septum distance and the end-systolic volume index (ESVi) were increased. The ESPS/ESVi ratio,a loading independent parameter, was decreased in SCA, suggesting systolic dysfunction. No significant differences in the diastolic function or in the pulmonary pressure occurred. CONCLUSION: Chamber dilations, eccentric hypertrophy and systolic dysfunction confirm the evidence of the literature in characterizing a sickle cell anemia cardiomyopathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To describe a new more efficient method of endocardial cardiac stimulation, which produces a narrower QRS without using the coronary sinus or cardiac veins. METHODS: We studied 5 patients with severe dilated cardiomyopathy, chronic atrial fibrillation and AV block, who underwent definitive endocardial pacemaker implantation, with 2 leads, in the RV, one in the apex and the other in the interventricular septum (sub pulmonary), connected, respectively, to ventricular and atrial bicameral pacemaker outputs. Using Doppler echocardiography, we compared, in the same patient, conventional (VVI), high septal ("AAI") and bifocal ("DDT" with AV interval ~ 0) stimulation. RESULTS: The RV bifocal stimulation had the best results with an increase in ejection fraction and cardiac output and reduction in QRS duration, mitral regurgitation and in the left atrium area (p <= 0.01). The conventional method of stimulation showed the worst result. CONCLUSION: These results suggest that, when left ventricular stimulation is not possible, right ventricular bifocal stimulation should be used in patients with severe cardiomyopathy where a pacemaker is indicated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the early outcome of mitral valve prostheses implantation and left ventricular remodeling in 23 patients with end-stage cardiomyopathy and secondary mitral regurgitation (NYHA class III and IV). METHODS: Mitral valvular prosthesis implantation with preservation of papillary muscles and chordae tendinae, and plasty of anteriun cuspid for remodeling of the left ventricle. RESULTS: The surgery was performed in 23 patients, preoperative ejection fraction (echocardiography) varied from 13% to 44% (median: 30%). In 13 patients associated procedures were performed: myocardial revascularization (9), left ventricle plicature repair (3) and aortic prosthese implantation (1). Early deaths (2) occurred on the 4th PO day (cardiogenic shock) and on the 20th PO day (upper gastrointestinal bleeding), and a late death in the second month PO (ventricular arrhythmia). Improvement occurred in NYHA class in 82.6% of the patients (P<0.0001), with a survival rate of 86.9% (mean of 8.9 months of follow-up). CONCLUSION: This technique offers a promising therapeutic alternative for the treatment of patients in refractory heart failure with cardiomyopathy and secondary mitral regurgitation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To determine the prevalence and other epidemiological characteristics of congenital heart diseases. METHODS: A retrospective population based study of children who were born in Londrina, from January '89 to December '98 (80,262 live births). Diagnoses were confirmed through autopsy, surgery, catheterization, or echocardiography. RESULTS: A total of 441 patients was as certained what corresponds to a prevalence of 5.494:1,000 live births. Ventricular septal defect was the commonest lesion. A small number of transpositions of the great vessels and of left ventricular hypoplasia was observed. A high propation of ventricular septal defect (28.3%) and atrioventricular septal defects (8.1%) occurred. Fifty-one (11.35%) affected children had syndromic diseases and 52 (12.01%) children had nonsyndromic anomalies. CONCLUSION: The prevalence of congenital heart diseases in Londrina is in accordance with that of other regions of the globe. This prevalence also may reflect the reality in the southern region of Brazil, because population characteristics are very similar in the 3 southernmost Brazilian states.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A rare association of pulmonary atresia with an intact septum was diagnosed through echocardiography in a fetus 32 weeks of gestational age. The diagnosis was later confirmed by echocardiography of the newborn infant and further on autopsy. The aortic valve was bicuspid with a pressure gradient of 81mmHg, and the right ventricle was hypoplastic, as were the pulmonary trunk and arteries, and the blood flow was totally dependent on the ductus arteriosus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ebstein's anomaly is an uncommon congenital heart defect, with a prevalence of 0.3-0.5%. Its association with an imperforate tricuspid valve is an even more rare situation (less than 10% of cases). Prenatal diagnosis of this association by means of fetal echocardiography has not been reported. We describe here this association diagnosed before birth and confirmed after birth. The diagnostic potential and importance of fetal echocardiography during prenatal evaluation of cardiac malformations allows for adequate perinatal planning and management, with an obvious impact on morbidity and mortality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is the report of a case of fetal tachyarrhythmia with 1:1 atrioventricular conduction detected by pre-natal echocardiography in a fetus at 25-weeks gestation. Adenosine infusion via cordocentesis was performed as a diagnostic test to differentiate between atrioventricular nodal reentrant supraventricular tachyarrhythmia and atrial flutter. After infusion, transient 2:1 atrioventricular dissociation was obtained and the diagnosis of atrial flutter was made. Transplacental therapy with digoxin and amiodarone was then successfully used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multiple arterial anomalies characterized by tortuosity and rolling of the pulmonary arteries and aorta were diagnosed on echocardiography in an asymptomatic newborn infant with a phenotype suggesting Ehlers-Danlos syndrome. These changes were later confirmed on angiography, which also showed peripheral vascular abnormalities. The electrocardiogram showed a probable hemiblock of the left anterosuperior branch, and the chest x-ray showed an excavated pulmonary trunk with normal pulmonary flow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate cardiac findings in 31 Noonan syndrome patients. METHODS: Thirty-one (18 males and 13 females)patients from 26 families affected with Noonan's syndrome were evaluated from the cardiac point of view with electrocardiography and echodopplercardiography. RESULTS: Twenty patients had some type of cardiac abnormality. The most frequent was pulmonary valve stenosis followed by hypertrophic myocardiopathy, commonly associated with valve defects. Upper deviation of the QRS axis was observed in 80% of these patients. CONCLUSION: In view of the high frequency and diversity of cardiac abnormalities present in Noonan syndrome, cardiac evaluation with electrocardiography and echocardiography should be performed in all patients diagnostically suspected of having this disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To identiy left ventricular geometric patterns in hypertensive patients on echocardiography, and to correlate those patterns with casual blood pressure measurements and with the parameters obtained on a 24-hour ambulatory blood pressure monitoring. METHODS: We studied sixty hypertensive patients, grouped according to the Joint National Committee stages of hypertension.. Using the single- and two-dimensional Doppler Echocardiography, we analyzed the left ventricular mass and the geometric patterns through the correlation of left ventricular mass index and relative wall thickness. On ambulatory blood pressure monitoring we assessed the means and pressure loads in the different geometric patterns detected on echocardiography RESULTS: We identified three left ventricular geometric patterns: 1) concentric hypertrophy, in 25% of the patients; 2) concentric remodeling, in 25%; and 3) normal geometry, in 50%. Casual systolic blood pressure was higher in the group with concentric hypertrophy than in the other groups (p=0.001). Mean systolic pressure in the 24h, daytime and nighttime periods was also higher in patients with concentric hypertrophy, as compared to the other groups (p=0.003, p=0.004 and p=0.007). Daytime systolic load and nighttime diastolic load were higher in patients with concentric hypertrophy ( p=0.004 and p=0.01, respectively). CONCLUSIONS: Left ventricular geometric patterns show significant correlation with casual systolic blood pressure, and with means and pressure loads on ambulatory blood pressure monitoring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To determine the predictive values of noninvasive tests for the detection of allograft vascular disease. METHODS: We studied 39 patients with mean ages of 48±13 years and a follow-up period of 86±13 months. The diagnosis of allograft vascular disease was made by cine-coronary arteriography, and it was considered as positive if lesions existed that caused > or = 50% obstruction of the lumen. Patients underwent 24h Holter monitoring, thallium scintigraphy, a treadmill stress test, and dobutamine stress echocardiography. Sensitivity, specificity, and positive and negative predictive values were determined in percentages for each method, as compared with the cine-coronary arteriography results. RESULTS: Allograft vascular disease was found in 15 (38%) patients. The Holter test showed 15.4% sensitivity, 95.5% specificity. For the treadmill stress test, sensitivity was 10%, specificity was 100%. When thallium scintigraphy was used, sensitivity was 40%, specificity 95.8%. On echocardiography with dobutamine, we found a 63.6% sensitivity, 91.3% specificity. When the dobutamine echocardiogram was associated with scintigraphy, sensitivity was 71.4%, specificity was 87%. CONCLUSION: In this group of patients, the combination of two noninvasive methods (dobutamine echocardiography and thallium scintigraphy) may be a good alternative for the detection of allograft vascular disease in asymptomatic patients with normal ventricular function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze clinical and histologic findings of 50 patients with primary neoplams of the heart in a tertiary referral center. METHODS: From 1980 to 1998, we retrospectively analyzed 50 patients, 32 of whom were females, whose ages ranged from 9 to 73 years (mean age = 44.16±18 years). RESULTS: Most tumors were located in the left side of the heart (72%), myxoma being the most common (84%) histologic type. The other histologic types found were as follows: fibroma (4%), lipoma (2%), rhabdomyosarcoma (2%), hemangioma (2%), sarcoma (2%), angiosarcoma (2%), and lymphoma (2%). Diagnosis was established by echocardiography in 94% of the cases. Clinical findings were as follows: dyspnea (36%), weight loss (20%), palpitations (18%), chest pain (16%), fever (8%), and arthralgia (6%). All patients with thromboembolic phenomena (10%) had left atrial myxoma. Approximately 20% of the patients were asymptomatic at the initial clinical assessment. CONCLUSION: Primary cardiac tumors are a rare entity with diverse clinical and histologic findings, requiring, therefore, a high level of clinical suspicion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the case of a patient with a pseudoaneurysm of the ascending aortic clinically diagnosed 5 months after surgical replacement of the aortic valve. Diagnosis was confirmed with the aid of two-dimensional echocardiography and helicoidal angiotomography. The corrective surgery, which consisted of a reinforced suture of the communication with the ascending aorta after opening and aspiration of the cavity of the pseudoaneurysm, was successfully performed through a complete sternotomy using extracorporeal circulation, femorofemoral cannulation, and moderate hypothermia, with no aortic clamping.