167 resultados para TRANSVAGINAL COLOR DOPPLER


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uterine arteriovenous malformations may cause life-threatening abnormal genital bleeding in women at childbearing age. Transvaginal Doppler ultrasonography is a widely available, noninvasive and excellent diagnostic method. The authors report the case of a patient with history of gestational trophoblastic disease and multiple curettage procedures who developed uterine arteriovenous malformations, with remission of the lesions after treatment with methotrexate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:Longitudinal study with B-mode ultrasonography and Doppler ultrasonography of maternal kidneys and liver in low-risk pregnancy, to establish and quantify normality parameters, correlating them with physiological changes.Materials and Methods:Twenty-five pregnant women were assessed and selected to participate in the study, each of them undergoing four examinations at the first, second, third trimesters and postpartum.Results:Findings during pregnancy were the following: increased renal volume, pyelocaliceal dilatation with incidence of 45.4% in the right kidney, and 9% in the left kidney; nephrolithiasis, 18.1% in the right kidney, 13.6% in the left kidney. With pyelocaliceal dilatation, mean values for resistivity index were: 0.68 for renal arteries; 0.66 for segmental arteries; 0.64 for interlobar arteries; 0.64 for arcuate arteries. Without pyelocaliceal dilatation, 0.67 for renal arteries; 0.64 for segmental arteries; 0.63 for interlobar arteries; and 0.61 for arcuate arteries. Portal vein flow velocities presented higher values in pregnancy, with mean value for maximum velocity of 28.9 cm/s, and 22.6 cm/s postpartum. The waveform pattern of the right hepatic vein presented changes persisting in the postpartum period in 31.8% of the patients. Cholelithiasis was observed in 18.1% of the patients.Conclusion:Alterations in renal volume, pyelocaliceal dilatation, nephrolithiasis, cholelithiasis, changes in portal vein flow velocity, alterations in waveform pattern of the right hepatic vein, proved to be significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We are working in a new multi-doped glassy material to generate simultaneously the three primary light color (by addition) of the visible spectrum, with the control of the intensity of each one, allowing the simulation of any color: a full-color generator device. Tm+3, Tb+3 and Eu+3 ions were used (0.01 to 5,0 mol%) as blue, green and red narrow line emitters. A wide color gamut was obtained under ultraviolet excitation by varying the material composition. The chromaticity diagram is covered, including the white simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fourier transform infrared attenuated total reflectance (FT-IR ATR) spectroscopy was used to determine 14 different measurands in northeast Brazilian honey samples. Nine different honey samples (six monofloral and three polyfloral) from 2009 obtained from the company CEARAPI underwent FT-IR ATR, palynological, color, and sensorial analysis to obtain preliminary results for these types of honey. The results showed that there are five monofloral, three bifloral, and one extrafloral honey, and also that mid-infrared spectrometry can be used as a screening method for the routine analysis of Brazilian honey, with the advantages of being rapid, nondestructive, and accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed at evaluating the effects of ethylene on peel color and compositional changes in ‘Lane late’ orange stored under refrigerated and ambient conditions. Physiologically mature, but green-peeled, oranges were exposed to ethylene gas under room temperature and high relative humidity for 24 hours. Storage chamber was ventilated with fresh air after 12 hours to mitigate consequences derived from fruit respiration. Both nondestructive analysis, such as peel color (hue angle, chromaticity, and brightness) and weight loss, and destructive ones (soluble solids, titratable acidity, pH, soluble solids to acidity ratio, and puncture force) were performed upon harvest, after degreening, and every three days during eighteen days in storage. Experiment was carried out using an entirely randomized design with thirty replications for nondestructive and four replications for destructive analyses, in a split plot scheme. Exposure to ethylene ensured a golden yellow peel for both fruit stored under ambient and refrigerated conditions. High relative humidity, associated with low temperature prevented fruit from losing moisture. Fruit exposure to ethylene did not affect weight loss, soluble solids, titratable acidity, pH, soluble solids, acidity ratio, or puncture force.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVOS: Correlacionar os achados da biópsia transcutânea hepática guiada por ultrassonografia com os dados ultrassonográficos modo B e Doppler da veia hepática direita; comparar os padrões de onda entre os grupos de estudo (hepatopatas) e controle (sadios); e avaliar se o Doppler da veia hepática direita serve como marcador de hepatopatia crônica. MÉTODOS: Foram estudados 38 pacientes portadores de hepatopatia crônica comprovada por sorologia e biópsia (grupo de estudo) e dez pacientes sem hepatopatia sorológica (grupo controle), avaliados pela ultrassonografia modo B e Doppler. Os critérios histológicos foram a classificação da Sociedade Brasileira de Patologia de Hepatite Crônica. RESULTADOS: A ultrassonografia modo B e o Doppler diferenciaram os indivíduos portadores de hepatopatia crônica dos normais (p=0,047). Houve diferença significativa entre o grupo de estudo e o controle na comparação entre os achados histopatológicos, ultrassonográficos modo B e o Doppler nos padrões de onda da veia hepática direita (p=0,001). CONCLUSÃO: Foi possível correlacionar a biópsia hepática com a ultrassonografia modo B e o Doppler da veia hepática direita; os hepatopatas apresentaram alteração no fluxo da veia hepática direita e os normais não, sendo que o padrão de onda nos controles saudáveis foi trifásico e nos hepatopatas bifásico ou monofásico; e o Doppler da veia hepática direita serviu como marcador de hepatopatia crônica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: avaliar a ocorrência do refluxo da safena magna através da ultrassonografia com Doppler colorido em sujeitos submetidos ao tratamento da insuficiência da junção safeno-femoral por ligadura simples ou por ligadura com secção da crossa. MÉTODOS: foram realizadas 60 operações (45 sujeitos) de varizes com insuficiência da junção safeno-femoral (JSF), pertencentes à classificação clínica do CEAP 2 a 5, que foram distribuídos aleatoriamente em dois grupos. Um grupo denominado C, com ligadura e secção da crossa, e um grupo denominado L, com ligadura simples sem secção da crossa da veia safena magna. Foi então pesquisada a ocorrência do refluxo da safena magna nos grupos C e L através da ultrassonografia doppler colorida após o tratamento cirúrgico com intervalos de seis meses a um ano. RESULTADOS: dos 60 membros submetidos à abordagem da crossa da safena magna, 57 foram avaliados pela ultrassonografia doppler pós-operatório, pois dois sujeitos (três membros) não retornaram e foram excluídos do estudo. A média de idade foi 54 anos, 93% do sexo feminino e predominância da classificação (CEAP) C2 de 60,5%. Das 57 operações para o tratamento do refluxo da crossa da safena, 43,9% apresentaram refluxo no pós-operatório, sendo 14,1% do grupo C e 29,8% no grupo L (p<0,05). O risco relativo de apresentar refluxo da crossa da safena no grupo L foi 2,03 vezes maior em comparação com o grupo C. CONCLUSÃO: a secção da crossa da safena magna apresenta menos refluxo pós-operatório do que a ligadura simples no tratamento da insuficiência da crossa da veia safena magna.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the prevalence of sonographic abnormalities (SA) in the axillary vein of patients with and without post-mastectomy lymphedema. METHODS: We studied a sample of 80 women, divided into two equal groups, with and without lymphedema, with B mode ultrasound, color and pulsed Doppler. The primary variable, SA, is defined as change in the venous diameter, parietal thickening, intraluminal images, compressibility, parietal collapse at inspiration and feature of the axillary venous flow on the operated side. Secondary variables were: stage of lymphedema, surgical technique, number of radio and chemotherapy sessions, limb volume, weight and age. The differences between the proportions in the groups were determined using the Chi-square test and / or Fisher's test. For continuous variables, we used the Mann-Whitney Test. To estimate the magnitude of the associations, we used the prevalence rate of SA in both groups as a measure of frequency, and as a measure of association, the prevalence ratio (PR) obtained as a function of relative risk (RR) and estimated by the test Mantel-Haenszel homogeneity test. We adopted the statistical significance level of 5% (p < 0.05). RESULTS: only the criterion "parietal thickening" was strongly associated with the lymphedema group (p = 0.001). The prevalence of SA was 55% in patients with lymphedema and 17.5% in the group without it, with difference in prevalence of 37.5%. CONCLUSION: the prevalence of SA was higher in patients undergoing mastectomy with lymphedema than in those without lymphedema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi determinar os fatores prognósticos para a ultimação do parto por via transpélvica em gestantes com cesárea anterior admitidas em trabalho de parto no CAM-IMIP. Foi realizado um estudo tipo caso-controle, analisando os partos de pacientes com cesárea prévia assistidos no CAM-IMIP no período de janeiro/1991 a dezembro/1994. Foram considerados casos as pacientes com cesárea anterior (n=156) e controles as que tiveram parto transvaginal (n=338). Os critérios de inclusão foram: idade gestacional > 36 semanas, cesárea anterior há pelo menos 1 ano, concepto vivo, trabalho de parto espontâneo e apresentação cefálica fletida. Foram excluídas as gestações de alto risco, os casos de sofrimento fetal anteparto e pacientes com história de parto transpélvico anterior depois da cesárea. A análise estatística foi realizada em Epi-Info 6.0 e Epi-Soft, utilizando-se os testes chi² de associação, teste exato de Fisher e "t" de Student, bem como a odds ratio e seu intervalo de confiança a 95%. Análise de regressão logística múltipla foi efetuada para controle das variáveis confundidoras. O percentual de cesáreas no grupo estudado foi de 31,6%. Os fatores maternos que apresentaram associação significativa com o parto transvaginal foram a idade materna < 20 anos (OR = 2,07, IC a 95% = 1,18-3,66) ou > 35 anos (OR = 0,54, IC a 95% = 0,36-0,82), a história de parto vaginal anterior (OR = 1,6, IC a 95% = 1,01-2,55) e a indicação da cesárea anterior por doenças da gestação (OR = 3,67, IC a 95% = 1,19-12,02). Fatores como intervalo entre a cesárea anterior e o parto atual, outras indicações de cesárea e o tipo de histerorrafia não apresentaram associação significativa com o parto transpélvico. No modelo de regressão logística múltipla, persistiram como variáveis associadas significativamente ao parto vaginal a idade materna e a história de parto vaginal anterior. Os autores concluíram que sendo a idade materna < 20 anos, a indicação de cesárea por doença da gestação e parto vaginal anterior associaram-se favoravelmente ao parto transpélvico em pacientes com cesárea anterior. O risco de cesariana está aumentado em gestantes a partir de 35 anos. Esses fatores devem ser considerados na avaliação obstétrica da via de parto nessas gestantes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: avaliar o colo uterino por meio do toque vaginal e da ultra-sonografia transvaginal em gestantes de risco elevado para o parto prematuro. Métodos: durante o período compreendido entre fevereiro de 1995 e setembro de 1997 foram acompanhadas 38 gestantes com elevado risco para o parto prematuro entre a 20ª e 36ª semana de gestação. Estas pacientes foram submetidas semanalmente ao toque vaginal e ao exame ultra-sonográfico transvaginal. O toque vaginal avaliou o colo uterino quanto a dois parâmetros: comprimento e dilatação. A ultra-sonografia transvaginal estudou o comprimento e o diâmetro anteroposterior do colo uterino. Foram analisados os comportamentos destas medidas cervicais ao longo da gestação. Os dois métodos foram comparados quanto à avaliação cervical e à acurácia no diagnóstico do parto prematuro. Resultados: a incidência de partos prematuros foi de 18,4% (7/38). As medidas do comprimento cervical obtidas pela ultra-sonografia foram sempre maiores em relação às medidas obtidas pelo toque vaginal. Mediante análise pelo teste de hipóteses foram observadas uma relação indireta entre o comprimento cervical e a idade gestacional por meio do toque e do estudo ultra-sonográfico (p<0,05 e p<0,01, respectivamente) e uma relação direta entre a dilatação cervical e a idade gestacional observada pelo toque (p<0,01). Conclusões: dos parâmetros estudados por meio do toque e da ultra-sonografia transvaginal, o comprimento cervical ultra-sonográfico apresentou melhor acurácia no diagnóstico do parto prematuro, revelando ser o mais confiável para a avaliação das alterações cervicais em gestantes de risco elevado para o parto prematuro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivos: atrasos no desenvolvimento do saco gestacional (SG), no tamanho do botão embrionário (CCN), assim como freqüências cardíacas embrionárias (FCE) baixas podem ser considerados fatores de mau prognóstico na evolução da gestação. O objetivo deste trabalho foi avaliar a utilização destes 3 parâmetros em conjunto, o que denominamos Teste Triplo Biofísico (TTB). Metodo: foram avaliadas 35 gestações únicas provenientes de fertilização assistida por injeção intracitoplasmática de espermatozóide (ICSI). Todos os exames de ultra-som foram realizados por um único examinador, após 4-5 semanas da transferência de embriões (6-7 semanas de gestação), com equipamento modelo Synergy da Diasonics, sonda transvaginal de 7,0 MHz. O SG foi medido em seu maior diâmetro transverso, o CCN foi medido no sentido sagital e a FCE pelo modo B-M e Doppler. Na análise estatística foi utilizado o teste de Fisher. Resultados: considerou-se como parâmetros alterados : SG < 15,4 mm; CCN < 3,9 mm e FCE < 100 bpm. Estes parâmetros foram calculados como média menos 1 desvio padrão das gestações em evolução (n = 32). As pacientes definidas com TTB positivo, isto é, as de risco para o aborto, foram aquelas que apresentaram pelo menos 2 parâmetros alterados. Das 35 gestações, o TTB foi positivo em 5, todas as 3 que abortaram e 2 que não abortaram. A diferença entre as que abortaram e as que evoluíram foi altamente significante (p = 0,0015; t-Fisher). A sensibilidade do método foi de 100%, com especificidade de 93,75%, o que resultou em uma eficácia de 96,87%. Conclusão: o TTB é um método ultra-sonográfico não-invasivo e apresenta uma alta eficácia na avaliação prognóstica da gestação inicial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: avaliar a eficácia do Doppler colorido como método diagnóstico na síndrome dos ovários policísticos (SOP), mediante as variações do fluxo sangüíneo no estroma ovariano, nas artérias uterinas e no tecido subendometrial. Métodos: foram selecionadas trinta pacientes distribuídas em dois grupos: quinze com amenorréia ou oligomenorréia, hirsutismo (índice de Ferriman e Gallwey >8), índice de massa corporal IMC maior que 25 kg/m² e exame ecográfico que identificou estroma aumentado, hiperecogênico e policistose ovariana (grupo de estudo), e número idêntico de pacientes com ciclos menstruais normais, sem sinais de hirsutismo e ultra-sonografia normal (grupo controle). Com o uso da dopplerfluxometria transvaginal foram medidas a velocidade de pico sistólico ou velocidade máxima (Vmáx), índice de pulsatilidade (IP) e resistência dos vasos do estroma ovariano, da artéria uterina e do subendométrio. Resultados: a dopplervelocimetria mostrou Vmáx significativamente maior no estroma ovariano das pacientes com SOP (12,2 cm/s) (p<=0,0004) em relação ao grupo controle (8,5 cm/s). O IP da artéria uterina também se revelou muito superior no grupo com SOP (3,3 cm/s) em relação ao controle (2,7 cm/s). Outros parâmetros da dopplervelocimetria não evidenciaram diferença significativa. Ao estabelecermos um cutoff (ponto de corte) = 9 cm/s na amostragem para a Vmáx obtivemos os percentuais de 95,2 para sensibilidade, 80,0 para especificidade e de 83,3 para o valor preditivo positivo e 94,1 para o negativo. Com referência ao IP para um cutoff = 2.35 os testes revelaram: sensibilidade de 81,0%, especificidade de 50,0%, valor preditivo positivo de 63,0% e negativo de 71,4%. Conclusão: a dopplervelocimetria pode constituir subsídio a ser incorporado à investigação clínica e ultra-sonográfica no tocante ao diagnóstico da síndrome dos ovários policísticos.