139 resultados para Slow release formulations
Resumo:
This paper describes a method for quantitative spot test analysis of hydrochlorothiazide using diffuse reflectance spectroscopy. The reflectance measurements were performed analyzing the colored compound (l = 585 nm) produced from the reaction between hydrochlorothiazide and p-dimethylaminocinnamaldehyde (PDAC) in acid medium. This reaction occurred on filter paper after heating to 80ºC for 8 minutes. Factorial designs allowed varying multiple reaction factors simultaneously in order to obtain the best reaction conditions. These factors included heating temperature, heating time, acid volume and PDAC volume. The linearity was studied in the range of 3.36x10-2 to 1.01x10-1 mol L-1 with a correlation coefficient of 0.998. The limit of detection was estimated to be 1.32x10² mol L-1. Commercial samples were analyzed using the proposed method and the results were favorably compared with those of the United States Pharmacopeia method, showing that quantitative spot test analysis by diffuse reflectance could be successfully used to determine hydrochlorothiazide in medicines.
Resumo:
A new, simple, precise, rapid and low-cost spectrophotometric method for methyldopa determination in pharmaceutical preparations is described. This method is based on the complexation reaction of methyldopa with molybdate. Absorbance of the resulting yellow coloured product is measured at 410 nm. Beer's Law is obeyed in a concentration range of 50 - 200 µg ml-1 methyldopa with an excellent correlation coefficient (r = 0.9999). No interference was observed from common excipients in formulations. The results show a simple, accurate, fast and readily applied method to the determination of methyldopa in pharmaceutical products. The analytical results obtained for these products by the proposed method are in agreement with those of the Brazilian Pharmacopoeia procedure at 95% confidence level.
Resumo:
A simple, sensitive and selective spectrophotometric method for the assessment of carbofuran in various formulations and in environmental water samples is described. The method is based on the coupling of hydrolyzed carbofuran with diazotized dapsone in alkaline medium at 0 4° C which gives orange red colored product having the absorption maximum at 480 nm. The product is stable for 48 h. Beer's law is obeyed in the concentration range of 0.1 4.0 µg ml-1. The molar absorptivity and Sandell's Sensitivity are 5.0 x 10(4) L mol-1 cm-1 and 4.4 ng cm-2 respectively. The method is highly reproducible and is confirmed by RSD values (1.144 %). From the recovery studies it is found that this method is accurate and it can be successfully employed for the determination of carbofuran.
Resumo:
A spectrophotometric flow injection method for the determination of paracetamol in pharmaceutical formulations is proposed. The procedure was based on the oxidation of paracetamol by sodium hypochloride and the determination of the excess of this oxidant using o-tolidine dichloride as chromogenic reagent at 430 nm. The analytical curve was linear in the paracetamol concentration range from 8.50 x 10-6 to 2.51 x 10-4 mol L-1 with a detection limit of 5.0 x 10-6 mol L-1. The relative standard deviation was smaller than 1.2% for 1.20 x 10-4 mol L-1 paracetamol solution (n = 10). The results obtained for paracetamol in pharmaceutical formulations using the proposed flow injection method and those obtained using a USP Pharmacopoeia method are in agreement at the 95% confidence level.
Resumo:
A simple analytical method for quantification of atenolol in pharmaceutical formulations by diffuse reflectance spectroscopy is described. The method is based on the reaction, on the filter paper surface, between the drug and p-chloranil producing a colored compound. The best reaction conditions were obtained with 20 µL of atenolol solution and 20 µL of p-chloranil. All reflectance measurements were carried out at 550 nm and the linear range was from 1.13x10-2 to 7.88x10-2 mol L-1 (r = 0.9992). The limit of detection was 2.80 x 10-3 mol L-1. The proposed method was successfully applied to analysis of different commercial brands of pharmaceutical formulations and the results obtained by the proposed method were in good agreement with those obtained using the British Pharmacopoeia method.
Resumo:
The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h-1 can be carried out with the proposed flow-batch analyser.
Resumo:
A spectrophotometric flow injection method for the determination of Zn(II) in ophthalmic formulations was developed. In this work, Zn(II) ion was complexed with Alizarin red S in borate buffer solution (pH 9.0) and the chromophore produced was monitored at 520 nm. The analytical curve was linear in the Zn(II) concentration range from 6.05 x 10-6 to 1.50 x 10-4 mol L-1 with a detection limit of 3.60 x 10-6 mol L-1. Recoveries ranged from 96.3 to 105 % and a relative standard deviation of 1.2 % (n = 10) for 5.5x10-5 mol L-1 Zn(II) reference solution were obtained. The sampling rate was 60 h-1 and the results obtained of Zn(II) in ophthalmic products using this procedure are in close agreement with those obtained using a comparative spectrophotometric procedure at 95 % confidence level.
Resumo:
Two new, simple, rapid and reproducible spectrophotometric methods have been developed for the determination of lamotrigine (LMT) both in pure form and in its tablets. The first method (method A) is based on the formation of a colored ion-pair complex (1:1 drug/dye) of LMT with bromocresol green (BCG) at pH 5.02±0.01 and extraction of the complex into dichloromethane followed by the measurement of the yellow ion-pair complex at 410 nm. In the second (method B), the drug-dye ion-pair complex was dissolved in ethanolic potassium hydroxide and the resulting base form of the dye was measured at 620 nm. Beer's law was obeyed in the concentration range of 1.5-15 µg mL-1 and 0.5-5.0 µg mL-1 for method A and method B, respectively, and the corresponding molar absorptivity values are 1.6932 x 10(4) and 3.748 x 10(4) L mol-1cm-1. The Sandell sensitivity values are 0.0151 and 0.0068 µg cm-2 for method A and method B, respectively. The stoichiometry of the ion-pair complex formed between the dug and dye (1:1) was determined by Job's continuous variations method and the stability constant of the complex was also calculated. The proposed methods were applied successfully for the determination of drug in commercial tablets.
Resumo:
A simple, rapid, accurate and inexpensive spectrophotometric method for the determination of tetracycline and doxycycline has been developed. The method is based on the reaction between these drugs and chloramine-T in alkaline medium producing red color products with absorbance maximum at the Λ = 535 and 525 nm for the tetracycline and doxycycline, respectively. The best conditions for the reactions have been found using multivariate method. Beer´s law is obeyed in a concentration ranges 1.03 x 10-5 to 3.61 x 10-4 mol L-1 and 1.75 x 10-5 to 3.48 x 10-4 mol L-1 for the tetracycline and doxycycline, respectively. The quantification limits were 5.63 x 10-6 mol L-1 and 7.12 x 10-7 mol L-1 for the tetracycline and doxycycline, respectively. The proposed method was successfully applied to the determination of these drugs in pharmaceutical formulations and the results obtained were in good agreement with those obtained by the comparative method at the 95% confidence level.
Resumo:
Objective: To evaluate the safety and tolerability of controlled-release oxycodone in the treatment of postoperative pain of head and neck oncologic resections.Methods: We conducted a prospective, observational and open study, with 83 patients with moderate to severe pain after head and neck oncological operations. All patients received general anesthesia with propofol, fentanyl and sevoflurane. Postoperatively, should they have moderate or severe pain, we began controlled-release oxycodone 20 mg 12/12 b.i.d on the first day and 10 mg b.i.d. on the second. We assessed the frequency and intensity of adverse effects, the intensity of postoperative pain by a verbal numeric scale and the use of rescue analgesia from 12 hours after administration of the drug and between 7 and 13 days after the last oxycodone dose.Results: The most common adverse events were nausea, vomiting, dizziness, pruritus, insomnia, constipation and urinary retention, most mild. No serious adverse events occurred. In less than 12 hours after the use of oxycodone, there was a significant decrease in the intensity of postoperative pain, which remained until the end of the study. The rescue medication was requested at a higher frequency when the opioid dose was reduced, or after its suspension.Conclusion: Controlled release oxycodone showed to be safe and well tolerated and caused a significant decrease in post-operative pain.
Resumo:
The behavior of Petrov-Galerkin formulations for shallow water wave equations is evaluated numerically considering typical one-dimensional propagation problems. The formulations considered here use stabilizing operators to improve classical Galerkin approaches. Their advantages and disadvantages are pointed out according to the intrinsic time scale (free parameter) which has a particular importance in this kind of problem. The influence of the Courant number and the performance of the formulation in dealing with spurious oscillations are adressed.
Resumo:
Recent studies indicate that glyphosate applied in post-emergence in RR soybean can eventually cause phytotoxic effects. However, there are many questions that need to be clarified in the scientific and technical contexts, involving the issue of RR soybeans regarding the use of glyphosate. This study has assessed the impact of the application of different doses and formulations of glyphosate in the reproductive period of RR soybean (R1 stage). For that purpose, an experiment in the field was conducted in two harvests (2011/12 and 2012/13), in which a 2 x 5 factorial design was used (formulations versus doses) totaling 10 treatments. In these two experiments the variables related to agronomic performance were: phytotoxicity (7, 14, 21 and 28 days after application), plant height, number of pods per plant, yield and weight of 100 grains (end of soy cycle). The results obtained allowed characterizing phytotoxicity and damages to the height and yield in RR soybean, with increasing rates of glyphosate applied in the reproductive period.
Resumo:
Volatilization represents an important process in the displacement of pesticides for the environment. The physicochemical properties of the clomazone molecule indicate its relative volatility. Therefore, this study was carried out to assess the volatilization of different clomazone herbicide formulations using bioindicator species. To that end, airtight glass boxes were used with the presence of different clomazone formulations and plant species. The formulations used were Gamit 360 CS(r), Gamit 500 EC(r) and Gamit Star(r). The plant species assessed were maize, sorghum and rice. With the results obtained it is possible to conclude that, among the formulations, Gamit 360 CS(r) has caused less phytotoxicity to the bioindicator species in comparison to the formulations of Gamit 500 EC(r) and Gamit Star(r) formulations. In general, The Gamit 500 EC(r) and Gamit Star(r) have not differed in the phytotoxicity potential for the bioindicator species.
Resumo:
ABSTRACTEfficiency of weed control can be increased if the herbicide formulation provides higher target coverage and evaporation time that enable an adequate distribution of herbicide on the target plant, allowing the absorption to continue even after the droplets evaporation. The aim of this research was to assess the influence of glyphosate formulations on the wetted area and evaporation time of droplets on different targets. Tests were conducted with droplets sizing from 500 μm containing three formulations of glyphosate (isopropylamine salt, ammonium salt and potassium salt) deposited on three surfaces, two leaves (Bidens pilosa and Cenchrus echinatus) and glass slides. Sequential images analyses were used to quantify the evaporation time and the wetted area. An experimental system was utilized that was composed of a droplet generator, a stereo microscope with a camera to capture images, as well as an environmental chamber controlled for temperature and relative humidity. The kind of glyphosate formulations and target surfaces are crucial in the wetted area and evaporation time. The isopropylamine salt decreased the wetted area and evaporation time when compared with ammonium salt and potassium salt for all the surfaces deposited on. Bidens pilosa allows an increased wetted area for all the glyphosate formulations when compared to Cenchrus echinatus and glass slides.
Resumo:
The effect of iron-ore particles on the propagule release and growth of Sargassum vulgare C. Agardh was tested under treatments with different concentrations of iron-ore particles: 0.1, 1.0, 10.0 g.L-1 and a solution of 10.0 g.L-1 of filtered iron-ore. Filtered seawater was used as control. Photosynthesis vs. irradiance (P-I) curves were calculated for S. vulgare in the presence of iron-ore and in seawater. There was no significant difference in the number of propagules released by the receptacles or in the percentage of zygote formation among the treatments. The released propagules acted like aggregation centers for the particles, those more heavily coated with iron (10.0 g.L-1) exhibiting the highest sinking velocity (32.6 ± 9.8 mm.s-1). No difference in the percentage of embryo survival was detected during the first week in culture. After four weeks the embryos grew in all treatments. Maximum frond development (5.3 ± 0.8 mm) was observed in treatment of seawater enriched with Provasoli's medium (PES) while initial filoids did not develop in three treatments without PES and with iron-ore (0.1 g.L-1, 1.0 g.L-1 and 10.0 g.L-1). The values for Pmax, alpha and respiration showed no significant differences between the P-I curves. The calculated value for I K was 106.26 µmol.m-2.s-1 to the control curve and 981.49 µmol.m-2.s-1 to the iron-ore curve. The results indicate that the iron-ore particles in high concentration reduce the growth of S. vulgare as they recovered the embryos, juveniles and young plants. In contrast, the presence of the particles did not affect the release of gametes, percentage of zygote formation or the percentage of embryo survival.