128 resultados para Sensitivity and specificity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In population surveys in wich the Schistosoma mansoni intensity of infection is low, or in localities where the schistosomiasis control program had success the parasitologic methods lack in sensitivity. Despite of some limitations the immunological methods are useful to provide valuable information in such field conditions. Thus, the prevalaence of schistosomiasis in untreated population can be determined by the detection of IgG or IgM antibodies, as well as the incidence by the IgA antibodies , employing mainly immunofluorescence (IF) and immunoenzymatic (ELISA), and in some extent hemagglutination (HA) or even skin test. The true prevalence and incidence of schistosomiasis can be estimated using a probabilistic model equation, since knowing before-hand the sensitivity and specificity of emploved test. The sensitivity and the specificity of serologic test become higher in low aged group, under 14. The geometric mean IF titers also gives a positive correlation with the intensity of infection. Presently there are need of serologic tests wich are economic and pratical in soroepidemiologic inquires, requiring no specialized personnel to collect population blood or serum and also easily interpret the test results. The reagents for such tests are desired to be stable and reproducible. Moreover, it is expected that the tests can distinguish an ative infection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article reports upon a community survey of malaria in Prábis, Guinea-Bissau. A house to house census of the population was initially carried out from August to December 1991(rainy season). After completing the census of each village, the population was invited to come, a week later, to a central point, where they were medically examined and finger-prick blood samples were collected for epidemiological characterization of the malaria situation in the area. The blood films of the one single village were used to compare the sensitivity and specificity of Polymerase Chain Reaction (PCR) with optical microscopy detection of parasites. In another village, the occurrence of parasitaemia was compared in children with and without fever. During the dry season, from March to June 1992, the population in each village was again invited to come to a central point. Some of the field procedures were repeated. The study revealed Prábis as an administrative Sector of Guinea-Bissau with endemic malaria, mostly due to Plasmodium falciparum, but with a significant rate of mixed infections. Active transmission occurred throughout the year, but it was more intensive during the rainy season and in the northwestern quadrant of the Sector. The level of endemicity of the villages varied from hypo to holoendemic. The factors associated with the differences among villages included village size and predominant economic activity (closeness to rice fields). The transmission paradigm was, most likely, a mixture of malaria of the African wet Savannah and malaria associated with irrigated paddy fields. PCR proved to be a sensitive method with low specificity during the dry season. Pyraexia of 37.4ºC or higher in children aged 2-9 years is not a sensitive indicator of parasitaemia but, it is highly specific and it has a clinically useful predictive value.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluorescent (acridine orange) microscopical examination of capillary centrifuged blood (quantitative buffy coat [QBC®] analysis) and Giemsa stained thick blood smears (GTS) were compared for diagnosis of malaria in blood specimens from adults living in malaria transmission areas of the States of Bolivar and Amazonas in southeastern and south Venezuela, respectively. Of a total of 198 GTS examined, 95 subjects (48%) showed parasitaemia. Among the 95 blood films with a positive GTS, 94 were judged positive by the QBC. However, positive QBC tubes were found in 29 out of 103 blood specimens with a negative GTS. Thus, relative to a GTS standard, the sensitivity and specificity of the QBC-test was 99.2% and 72%, respectively. Young trophozoites of Plasmodium vivax and P. falciparum could not be distinguished with certainty. It is confirmed that the QBC offers many advantages compared with the standard diagnosis of malaria parasites, specifically in the speed of staining and ease of interpretation. However, in places where P. falciparum and P. vivax occur, species and stage differentiation should be confirmed with the GTS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A recombinant-antigen enzyme immunoassay (EIA), BioSCREEN TM anti-Treponema pallidum, was compared favorably with the T. pallidum hemagglutination test, in the detection of specific antibodies in different groups of sera from patients with primary (n = 38), secondary (n = 10), early latent (n = 28) and congenital syphilis (n = 2), patients with leptospirosis ( n= 8), infectious mononucleosis (n = 7), hepatitis (n = 9), diabetes mellitus (n = 11), rheumatoid arthritis (n = 13), leprosy (n = 11), tuberculosis (n = 9), HIV/Aids ( n= 12), systemic lupus erythematosus (n = 4), rheumatic fever (n = 3), old-persons (n = 9), pregnant women (n = 29) and blood donors (n = 164). The coincidence between them was 95.1%. The sensitivity and specificity of the EIA were 93.3% and 95.5%, respectively. Fifteen serum specimens belonging to old-persons, pregnant women, blood donors, and patients with human leptospirosis, hepatitis, diabetes mellitus, tuberculosis and rheumatic fever gave false-positive results by Venereal Disease Research Laboratory and/or Rapid Plasma Reagin. The EIA can be used as alternative method for the serological confirmation of syphilis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As Schistosoma sp. control programs are chiefly based on treatment of infected population, adequate case finding has a crucial role. The available diagnostic methods are far from ideal, since the search for eggs in stools and the detection of circulating antigens lack sensitivity in low prevalence and post-treatment situations and antibody detection lacks specificity. In most endemic foci, repeated treatment of infected people leaves a number of non-diagnosed and consequently non-treated persons, enough to maintain a persistent residue of 5 to 10% prevalence. In an attempt to surpass these diagnostic limitations we have developed a polymerase chain reaction (PCR) for the detection of Schistosoma sp. in feces that, in a first population study, has shown to be more sensitive than three-repeated stool Kato-Katz examination. The PCR may constitute a valuable tool for the diagnosis of the Schistosoma sp. infection in special situations, when high sensitivity and specificity are required and infrastructure is available.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study was conducted to evaluate the frequency of antigenic components recognized by serum IgG antibodies in Western blotting (WB) using a Strongyloides ratti larval extract for the diagnosis of human strongyloidiasis. In addition, the WB results were compared to the enzyme-linked immunosorbent assay (ELISA) and the indirect immunofluorescence antibody test (IFAT) results. Serum samples of 180 individuals were analyzed (80 with strongyloidiasis, 60 with other intestinal parasitoses, and 40 healthy individuals). S. ratti was obtained from fecal culture of experimentally infected Rattus rattus. For IFAT, S. ratti larvae were used as antigen and S. ratti larval antigenic extracts were employed in WB and ELISA. Eleven S. ratti antigenic components were predominantly recognized by IgG antibodies in sera of patients with strongyloidiasis. There was a positive concordance for the three tests in 87.5% of the cases of strongyloidiasis. The negative concordance in the three tests was 94% and 97.5%, in patients with other intestinal parasitoses and healthy individuals, respectively. In cases of positive ELISA and negative IFAT results, diagnosis could be confirmed by WB. ELISA, IFAT, and WB using S. ratti antigens showed a high rate of sensitivity and specificity. In conclusion, WB using S. ratti larval extract was able to recognize 11 immunodominant antigenic components, showing to be a useful tool to define the diagnosis in cases of equivocal serology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study was conducted to detected IgG antibodies using Strongyloides venezuelensis alkaline extract for the diagnosis of human strongyloidiasis by the enzyme-linked immunosorbent assay (ELISA). Sera from 90 subjects were analyzed (30 with strongyloidiasis, 30 with other parasites and 30 healthy individuals). Results were expressed in antibody titers, which were considered as positive when titer was > 80. Sensibility and specificity of the assay were 100% and 96.7%, respectively. It can be concluded that the heterologous alkaline extract could be employed in ELISA as a diagnostic aid in human strongyloidiasis, due to its advantages as easiness of obtaining, practicability in preparing, and high indexes of sensitivity and specificity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A highly specific pattern of immunofluorescence was noted when sera from Capillaria hepatica-infected rats were tested against the homologous worms and eggs present either in paraffin or cryostat sections from mouse liver. The pattern was represented by a combined apple green fluorescence of the internal contents of worms and eggs, which persisted in serum-dilutions of 1:400 up to 1:1600. Unequivocal fluorescent pattern was observed from 15 days up to 3 months following inoculation of rats with embryonated C. hepatica eggs and such result was confirmed by the ELISA. After the 4th month of infection, the indirect immunofluorescence test turned negative, probably revealing the extinction of parasitism, however the ELISA was contradictory, disclosing high levels of antibodies in this period . The IIF was also negative when control normal rat sera and sera from rats administered by gavage with immature C. hepatica eggs (spurious infection), or for reactions made against Schistosoma mansoni eggs, although a weakly positive pattern occurred with Fasciola hepatica eggs. The indirect immunofluorescence test may be recommended for use with human sera to detect early C. hepatica infection in special clinical instances and in epidemiological surveys, since it is a simple, inexpensive, and reliable test, presenting excellent sensitivity and specificity. Although the diagnosis is positive only during early infection, this is the period when the symptoms are usually more severe and the need for differential diagnosis is greater.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed at implementing a Nested-polymerase chain reaction (Nested-PCR) for the molecular diagnosis of human T-cell lymphotropic virus type I/II (HTLV-I and HTLV-II) infections in peripheral blood mononuclear cells of infected subjects in Argentina. The sensitivity and specificity of the assay for the detection of regional strains were assessed by comparing them with the molecular assay of reference PCR-hybridization. The Nested-PCR detected 1 MT-2 cell (³ 8 proviral copies)/1x106 non-infected cells showing high sensitivity for provirus detection. While both molecular assays showed high specificity (100%) for HTLV-I and HTLV-II detection, the sensitivity values differed: 100% for Nested-PCR and 67% for PCR-hybridization assay. Moreover, this technique showed less sensitivity for the detection of DNA sequences of HTLV-II (33%) than for the detection of DNA sequences of HTLV-I (75%). The high sensitivity and specificity of the Nested-PCR for regional strains and its low costs indicate that this assay could replace the PCR-hybridization assay for the molecular diagnosis of HTLV-I/II infections. It will be interesting to assess the usefulness of this assay as a tool for the molecular diagnosis of HTLV-I/II infections in other developing countries. Other studies that include a greater number of samples should be conducted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compares smear, growth in Lowenstein-Jensen medium, and in-house polymerase chain reaction (PCR) techniques for the detection of Mycobacterium tuberculosis. A total of 72 specimens from 72 patients with clinical symptoms of tuberculosis, including 70 sputum and two bronchial aspirate samples, were tested in parallel by smear, culture, and in-house PCR techniques. From these, 48 (66.6%) were negative by the 3 methods, 2 (2.8%) were smear positive and negative by culture and in-house PCR, 11 (15.3%) were both smear and culture negative, and in-house PCR positive, 7 (9.7%) were positive by the 3 methods, 2 (2.8%) were positive by smear and culture, and negative by PCR, 2 (2.8%) were positive by culture and PCR, but smear negative. After the resolution of discrepancies in PCR results, the sensitivity and specificity for in-house PCR technique to M. tuberculosis relative to the culture, were 81.8% and 81.9%, respectively. These results confirm that this method, in-house PCR, may be a sensitive and specific technique for M. tuberculosis detection, occurring in both positive and negative smear and negative cultures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was aimed at investigating alternate methods for serodiagnosis of tuberculosis (TB), which are needed because bacteriologic diagnosis of childhood TB is difficult. A selection of 80 serum and saliva samples were tested from Warao indigenous children under 15 years of age; 34 high TB suspects (28 positive and 6 negative for the tuberculin skin test, TST) and 46 healthy contact children (32 positive and 14 negative for the TST). Several enzyme-linked immunosorbent assay (ELISA) serological tests were developed to test for Mycobacterium tuberculosis-specific antibodies, including serum IgA, IgG, IgE, and secretory IgA (sIgA) in saliva against 3 specific antigens (PPD, HSP60, 38 kDa). Of these, 2 antigens, PPD and 38 kDa, showed significantly higher reactivity. The sensitivity and specificity of these tests for diagnosis remained limited, between 26.5% and 38.2%, and 77.4% and 97%, respectively. Of all the samples studied and combinations realized between all isotypes and antigens combined with 3 isotypes (anti-PPD IgG, IgE, and anti-38kDa sIgA) managed to detect the largest number of patients, showing an improved sensitivity level of 64.7%, although specificity levels dropped to 81.8%. These results were compared with the Omega diagnostics commercial kit results. The commercial kits showed significantly lower reactivity (sensitivity of 20% and 13.33% to Myco G and Complex Plus, respectively) and a specificity of 100%. This study shows that in indigenous populations of Venezuela, where invasive procedures cannot be used to select samples but evaluation with a chest X-ray for radiological studies is available, the combination of 3 specific isotypes may be a useful tool to increase diagnostic accuracy with pulmonary TB in this population, when used together with clinical and epidemiological criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coagulase-negative staphylococci (CNS) species identification is still difficult for most clinical laboratories. The scheme proposed by Kloos and Schleifer and modified by Bannerman is the reference method used for the identification of staphylococcal species and subspecies; however, this method is relatively laborious for routine use since it requires the utilization of a large number of biochemical tests. The objective of the present study was to compare four methods, i.e., the reference method, the API Staph system (bioMérieux) and two methods modified from the reference method in our laboratory (simplified method and disk method), in the identification of 100 CNS strains. Compared to the reference method, the simplified method and disk method correctly identified 100 and 99% of the CNS species, respectively, while this rate was 84% for the API Staph system. Inaccurate identification by the API Staph method was observed for Staphylococcus epidermidis (2.2%), S. hominis (25%), S. haemolyticus (37.5%), and S. warneri (47.1%). The simplified method using the simple identification scheme proposed in the present study was found to be efficient for all strains tested, with 100% sensitivity and specificity and proved to be available alternative for the identification of staphylococci, offering, higher reliability and lower cost than the currently available commercial systems. This method would be very useful in clinical microbiology laboratory, especially in places with limited resources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dot enzyme-linked immunosorbent assay (dot-ELISA) was standardized using excretory-secretory antigens of Toxocara canis for the rapid immunodiagnosis of human toxocariasis. Thirty patients with clinical signs of toxocariasis, 20 cases with other parasitic diseases, and 40 healthy subjects were tested. A total of 0.2 ng of antigen per dot, serum dilution of 1:160 and dilution conjugate of 1:1000 were found optimal. The sensitivity and specificity of the assay were 100 and 95%, respectively. Comparable sensitivity of dot-ELISA and the standard ELISA was obtained, but only 3 cross-reactions occurred in the dot-ELISA, compared with 6 in the standard ELISA. Dot-ELISA is simple to perform, rapid, and low cost. Large-scale screening studies should be done to evaluate its usefulness under field conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study was carried out to compare the performance of a commercial method (MGIT) and four inexpensive drug susceptibility methods: nitrate reductase assay (NRA), microscopic observation drug susceptibility (MODS) assay, MTT test, and broth microdilution method (BMM). A total of 64 clinical isolates of Mycobacterium tuberculosis were studied. The Lowenstein-Jensen proportion method (PM) was used as gold standard. MGIT, NRA, MODS, and MTT results were available on an average of less than 10 days, whereas BMM results could be reported in about 20 days. Most of the evaluated tests showed excellent performance for isoniazid and rifampicin, with sensitivity and specificity values > 90%. With most of the assays, sensitivity for ethambutol was low (62-87%) whereas for streptomycin, sensitivity values ranged from 84 to 100%; NRA-discrepancies were associated with cultures with a low proportion of EMB-resistant organisms while most discrepancies with quantitative tests (MMT and BMM) were seen with isolates whose minimal inhibitory concentrations fell close the cutoff. MGIT is reliable but still expensive. NRA is the most inexpensive and easiest method to perform without changing the organization of the routine PM laboratory performance. While MODS, MTT, and BMM, have the disadvantage from the point of view of biosafety, they offer the possibility of detecting partial resistant strains. This study shows a very good level of agreement of the four low-cost methods compared to the PM for rapid detection of isoniazid, rifampicin and streptomycin resistance (Kappa values > 0.8); more standardization is needed for ethambutol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new multiplex assay platform was evaluated to detect Trypanosoma cruzi infection using the recombinant antigens CRA, FRA, CRAFRA fusion and parasite lysate. The antigens presented different sensitivity and specificity in a singleplex test when compared to a serial dilution of two pools comprising 10 positive serum samples and one pool of 10 negative samples. The recombinant protein CRA presented lower sensitivity (55%) in contrast to the 100% specificity and sensitivity of FRA, CRAFRA and T. cruzi lysate. These antigens also showed good results in a duplex test and the duplex test with CRAFRA/T. cruzi lysate showed better performance with 100% specificity and sensitivity, as well as a lower cut-off value in comparison to the other duplex test, FRA/T. cruzi lysate. Hence, when the antigens were used in duplex format, both tests showed decreased cut-off values and no interference between different bead sets, resulting in increasing sensitivity and specificity. The results of these multiplex tests show that they could be an alternative to singleplex detection for Chagas disease, and also indicate the necessity of using multiplex diagnostic tools to increase the sensitivity and specificity for diagnostic tests. Emerging data from the T. cruzi genome and from its ORFeome project will also allow the identification of new antigens for this disease detection application.