119 resultados para Scanline sampling technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was carried to evaluate the efficiency of the Bitterlich method in growth and yield modeling of the even-aged Eucalyptus stands. 25 plots were setup in Eucalyptus grandis cropped under a high bole system in the Central Western Region of Minas Gerais, Brazil. The sampling points were setup in the center of each plot. The data of four annual mesurements were colleted and used to adjust the three model types using the age, the site index and the basal area as independent variables. The growths models were fitted for volume and mass of trees. The efficiency of the Bitterlich method was confirmed for generating the data for growth and yield modeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to verify Point-Centered Quarter Method (PCQM) accuracy and efficiency, using different numbers of individuals by per sampled area, in 28 quarter points in an Araucaria forest, southern Paraná, Brazil. Three variations of the PCQM were used for comparison associated to the number of sampled individual trees: standard PCQM (SD-PCQM), with four sampled individuals by point (one in each quarter), second measured (VAR1-PCQM), with eight sampled individuals by point (two in each quarter), and third measuring (VAR2-PCQM), with 16 sampled individuals by points (four in each quarter). Thirty-one species of trees were recorded by the SD-PCQM method, 48 by VAR1-PCQM and 60 by VAR2-PCQM. The level of exhaustiveness of the vegetation census and diversity index showed an increasing number of individuals considered by quadrant, indicating that VAR2-PCQM was the most accurate and efficient method when compared with VAR1-PCQM and SD-PCQM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to evaluate the feasibility of vegetative propagation through cutting technique of seven tree species with strong occurrence in the riparian forest of the Lower São Francisco River in Sergipe State, under different concentrations of indolbutiric acid at 0, 2500, and 5000 mg.L-1, for potentialization of its use in soil bioengineering technique. It was used a complete random block design with three replicates, and a total of twenty-one treatments. The evaluation period was 120 days for each species, and the data collection was made in intervals of fifteen days, in a total of eight evaluations for each species. The evaluated parameters were: Survival Rate, callus formation, and Root Dry matter Weight. Among the studied species, Schinus terebinthifolius Raddi presented the best results related to cutting technique mainly under the indolbutiric acid concentration of 2500 mg.L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Taking into account that the sampling intensity of soil attributes is a determining factor for applying of concepts of precision agriculture, this study aims to determine the spatial distribution pattern of soil attributes and corn yield at four soil sampling intensities and verify how sampling intensity affects cause-effect relationship between soil attributes and corn yield. A 100-referenced point sample grid was imposed on the experimental site. Thus, each sampling cell encompassed an area of 45 m² and was composed of five 10-m long crop rows, where referenced points were considered the center of the cell. Samples were taken from at 0 to 0.1 m and 0.1 to 0.2 m depths. Soil chemical attributes and clay content were evaluated. Sampling intensities were established by initial 100-point sampling, resulting data sets of 100; 75; 50 and 25 points. The data were submitted to descriptive statistical and geostatistics analyses. The best sampling intensity to know the spatial distribution pattern was dependent on the soil attribute being studied. The attributes P and K+ content showed higher spatial variability; while the clay content, Ca2+, Mg2+ and base saturation values (V) showed lesser spatial variability. The spatial distribution pattern of clay content and V at the 100-point sampling were the ones which best explained the spatial distribution pattern of corn yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concern related to environment is growing. Due to this, it is needed to determine chemical elements in a large range of concentration. The neutron activation technique (NAA) determines the elemental composition by the measurement of artificial radioactivity in a sample that was submitted to a neutron flux. NAA is a sensitive and accurate technique with low detection limits. An example of application of NAA was the measurement of concentrations of rare earth elements (REE) in waste samples of phosphogypsum (PG) and cerrado soil samples (clayey and sandy soils). Additionally, a soil reference material of the International Atomic Energy Agency (IAEA) was also analyzed. The REE concentration in PG samples was two times higher than those found in national fertilizers, (total of 4,000 mg kg-1 ), 154 times greater than the values found in the sandy soil (26 mg kg-1 ) and 14 times greater than the in clayey soil (280 mg kg-1 ). The experimental results for the reference material were inside the uncertainty of the certified values pointing out the accuracy of the method (95%). The determination of La, Ce, Pr, Nd, Pm, Sm, Eu, Tb, Dy, Ho, Er, Tm, Yb and Lu in the samples and reference material confirmed the versatility of the technique on REE determination in soil and phosphogypsum samples that are matrices for agricultural interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scarcity of long-term series of sediment-related variables has led watershed managers to apply mathematical models to simulate sediment fluxes. Due to the high efforts for installation and maintenance of sedimentological gauges, tracers have been pointed out as an alternative to validate soil redistribution modelling. In this study, the 137Cs technique was used to assess the WASA-SED model performance at the Benguê watershed (933 km²), in the Brazilian semiarid. Qualitatively, good agreement was found among the 137Cs technique and the WASA-SED model results. Nonetheless, quantitatively great differences, up to two orders of magnitude, were found between the two methods. Among the uncertainties inherent to the 137Cs technique, definition of the reference inventory seems to be a major source of imprecision. In addition, estimations of water and sediment fluxes with mathematical models usually also present high uncertainty, contributing to the quantitative differences of the soil redistribution estimates with the two methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Precision agriculture based on the physical and chemical properties of soil requires dense sampling to determine the spatial variability of these properties. This dense sampling is often expensive and time-consuming. One technique used to reduce sample numbers involves defining management zones based on information collected in the field. Some researchers have demonstrated the importance of soil electrical variables in defining management zones. The objective of this study was to evaluate the relationship between the spatial variability of the apparent electrical conductivity and the soil properties in the coffee production of mountain regions. Spatial variability maps were generated using a geostatistical method. Based on the spatial variability results, a correlation analysis, using bivariate Moran's index, was done to evaluate the relationship between the apparent electrical conductivity and soil properties. The maps of potassium (K) and remaining phosphorus (P-rem) were the closest to the spatial variability pattern of the apparent electrical conductivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Insulinomas are rare endocrine tumors with an estimated incidence of 1(one) per million. Optimal therapy for all islet tumors of the pancreas is curative surgical resection. However, previous reports have show that, in the absence of preoparative localization, insulinoma may not be found intraoperatively in about 20% of patients. With current imaging technology, including serial computed tomography (CT), magnetic resonance imaging (MRI) and ultrasonography, localization of insulinomas less than 2cm remains inadequate. This case report shows that selective intraarterial calcium injection with hepatic venous sampling for insulin levels measured is a efficient technique for the localization of insulinomas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To standardize a technique for ventilating rat fetuses with Congenital Diaphragmatic Hernia (CDH) using a volume-controlled ventilator.METHODS: Pregnant rats were divided into the following groups: a) control (C); b) exposed to nitrofen with CDH (CDH); and c) exposed to nitrofen without CDH (N-). Fetuses of the three groups were randomly divided into the subgroups ventilated (V) and non-ventilated (N-V). Fetuses were collected on day 21.5 of gestation, weighed and ventilated for 30 minutes using a volume-controlled ventilator. Then the lungs were collected for histological study. We evaluated: body weight (BW), total lung weight (TLW), left lung weight (LLW), ratios TLW / BW and LLW / BW, morphological histology of the airways and causes of failures of ventilation.RESULTS: BW, TLW, LLW, TLW / BW and LLW / BW were higher in C compared with N- (p <0.05) and CDH (p <0.05), but no differences were found between the subgroups V and N-V (p> 0.05). The morphology of the pulmonary airways showed hypoplasia in groups N- and CDH, with no difference between V and N-V (p <0.05). The C and N- groups could be successfully ventilated using a tidal volume of 75 ìl, but the failure of ventilation in the CDH group decreased only when ventilated with 50 ìl.CONCLUSION: Volume ventilation is possible in rats with CDH for a short period and does not alter fetal or lung morphology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors present the four-arm single docking full robotic surgery to treat low rectal cancer. The eight main operative steps are: 1- patient positioning; 2- trocars set-up and robot docking; 3- sigmoid colon, left colon and splenic flexure mobilization (lateral-to-medial approach); 4-Inferior mesenteric artery and vein ligation (medial-to-lateral approach); 5- total mesorectum excision and preservation of hypogastric and pelvic autonomic nerves (sacral dissection, lateral dissection, pelvic dissection); 6- division of the rectum using an endo roticulator stapler for the laparoscopic performance of a double-stapled coloanal anastomosis (type I tumor); 7- intersphincteric resection, extraction of the specimen through the anus and lateral-to-end hand sewn coloanal anastomosis (type II tumor); 8- cylindric abdominoperineal resection, with transabdominal section of the levator muscles (type IV tumor). The techniques employed were safe and have presented low rates of complication and no mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors describe a surgical technique which allows, without increasing costs, to perform laparoscopic cholecystectomy with a single incision, without using specific materials and with better surgical ergonomics. The technique consists of a longitudinal umbilical incision, navel detachment, use of a permanent 10mm trocar and two clamps directly and bilaterally through the aponeurosis without the use of 5mm trocars, transcutaneous gallbladder repair with straight needle cotton suture, ligation with unabsorbable suture and umbilical incision for the specimen extraction. The presented technique enables the procedure with conventional and permanent materials, improving surgical ergonomics, with safety and aesthetic advantages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the application of aponeurotic sling by a modified technique with direct visualization of needles in patients with stress urinary incontinence. Methods: we applied the Kings Health Questionnaire (KHQ) for quality of life, gynecological examination, urinalysis I and urine culture approximately seven days prior to the urodynamic study (UDS) and the one-hour PAD test in patients undergoing making aponeurotic sling with its passing through the retropubic route with direct visualization of the needle, PAD test and King's Helth Questionnaire before and after surgery. Results: The mean age was 50.6 years, BMI of 28 and Leak Pressure (LP) 58,5cm H2O; 89% were Caucasian. Forty-six of them were monitored for three and six months, 43 for 12 months. The objective cure rate at 12 months postoperatively was approximately 93.5%. In evaluating quality of life, we observed a significant improvement in 12 months postoperatively compared with the preoperative period. There was no no urethral/bladder injury. As adverse results, we had one persistent urinary retention (2.3%), who was submitted to urethrolysis, currently without incontinence. Conclusion: The proposed procedure is safe as for the risk of bladder or urethral injuries, promoting significant improvement in quality of life and objective cure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare two methods of tear sampling for protein quantification. Tear samples were collected from 29 healthy dogs (58 eyes) using Schirmer tear test (STT) strip and microcapillary tubes. The samples were frozen at -80ºC and analyzed by the Bradford method. Results were analyzed by Student's t test. The average protein concentration and standard deviation from tears collected with microcapillary tube were 4.45mg/mL ±0.35 and 4,52mg/mL ±0.29 for right and left eyes respectively. The average protein concentration and standard deviation from tears collected with Schirmer Tear Test (STT) strip were and 54.5mg/mL ±0.63 and 54.15mg/mL ±0.65 to right and left eyes respectively. Statistically significant differences (p<0.001) were found between the methods. In the conditions in which this study was conducted, the average protein concentration obtained with the Bradford test from tear samples obtained by Schirmer Tear Test (STT) strip showed values higher than those obtained with microcapillary tube. It is important that concentration of tear protein pattern values should be analyzed according the method used to collect tear samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Shadow Moiré fringe patterns are level lines of equal depth generated by interference between a master grid and its shadow projected on the surface. In simplistic approach, the minimum error is about the order of the master grid pitch, that is, always larger than 0,1 mm, resulting in an experimental technique of low precision. The use of a phase shift increases the accuracy of the Shadow Moiré technique. The current work uses the phase shifting method to determine the surfaces three-dimensional shape using isothamic fringe patterns and digital image processing. The current study presents the method and applies it to images obtained by simulation for error evaluation, as well as to a buckled plate, obtaining excellent results. The method hands itself particularly useful to decrease the errors in the interpretation of the Moiré fringes that can adversely affect the calculations of displacements in pieces containing many concave and convex regions in relatively small areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The formal calibration procedure of a phase fraction meter is based on registering the outputs resulting from imposed phase fractions at known flow regimes. This can be straightforwardly done in laboratory conditions, but is rarely the case in industrial conditions, and particularly for on-site applications. Thus, there is a clear need for less restrictive calibration methods regarding to the prior knowledge of the complete set of inlet conditions. A new procedure is proposed in this work for the on-site construction of the calibration curve from total flown mass values of the homogeneous dispersed phase. The solution is obtained by minimizing a convenient error functional, assembled with data from redundant tests to handle the intrinsic ill-conditioned nature of the problem. Numerical simulations performed for increasing error levels demonstrate that acceptable calibration curves can be reconstructed, even from total mass measured within a precision of up to 2%. Consequently, the method can readily be applied, especially in on-site calibration problems in which classical procedures fail due to the impossibility of having a strict control of all the input/output parameters.