122 resultados para Micro-mechanical oscillators


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACTPeanut crop (Arachis hypogaeaL.) mechanization has been improved over the years; however there are drawbacks that affect the quality of operations. Thus, this article’s objectives were to evaluate the operational performance of the mechanized sowing of peanut crop according to seeding densities (10, 14, and 18 seeds m-1) and seed sizes (21 and 23 mm). It was observed that the seeds of 23 mm had shorter average number of days to emergence and a higher percentage of emergences, occurring the opposite to the seeding density of 18 seeds m-1. The higher the seeding density, the largest was the plant stand, whereas the 23 mm seed obtained the best results and the same with the seeding density of 14 seeds m-1 that had a higher percentage of normal spacing. The densities of 14 and 18 seeds m-1 reflected in higher yields, being always superior to the 23 mm seeds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Statistical process control in mechanized farming is a new way to assess operation quality. In this sense, we aimed to compare three statistical process control tools applied to losses in sugarcane mechanical harvesting to determine the best control chart template for this quality indicator. Losses were daily monitored in farms located within Triângulo Mineiro region, in Minas Gerais state, Brazil. They were carried over a period of 70 days in the 2014 harvest. At the end of the evaluation period, 194 samples were collected in total for each type of loss. The control charts used were individual values chart, moving average and exponentially weighted moving average. The quality indicators assessed during sugarcane harvest were the following loss types: full grinding wheel, stumps, fixed piece, whole cane, chips, loose piece and total losses. The control chart of individual values is the best option for monitoring losses in sugarcane mechanical harvesting, as it is of easier result interpretation, in comparison to the others.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Devido ao crescente uso dos aloenxertos nas cirurgias ortopédicas, há a necessidade do conhecimento de suas características biomecânicas ao longo do tempo de preservação. O presente trabalho consistiu na análise da força de resistência à micro-tração de amostras de ossos corticais de coelho preservadas em diversos meios por até 180 dias e a fresco. Os resultados revelaram que a resistência e o tempo de preservação apresentaram uma relação inversamente proporcional, significando que, quanto maior o tempo de preservação, menor a resistência física avaliada no ensaio biomecânico de resistência à micro-tração. Dos meios utilizados, a glicerina apresentou menores valores quanto ao teste de resistência, demonstrando, após 30 dias de preservação, apenas 24,58% da força presente no osso a fresco e, aos 180 dias, 1,76%. As amostras submetidas à autoclavagem também demonstraram baixos valores ao final do experimento, quando permaneceram com apenas 12,31% da força presente no osso a fresco. Os ossos preservados em plasma homólogo, líquido de dakin e aqueles criopreservados apresentaram os melhores índices de resistência ao final do experimento, permanecendo, respectivamente, com 82,47; 70,34 e 66,72% da força máxima quando comparados com a resistência dos ossos frescos. Concluiu-se que a escolha do método e o tempo de preservação interferiu diretamente na biomecânica dos ossos corticais, promovendo a diminuição da capacidade de resistência à tração ao longo do período de preservação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A substituição de parte do tecido ósseo se faz necessária muitas vezes na rotina cirúrgica, seja em função de fraturas, neoplasias ósseas ou enfermidades ortopédicas que acarretem em perda óssea. Neste sentido, têm se buscado biomateriais capazes de promover esta substituição, evitando o uso de enxertos ou transplantes ósseos. O objetivo deste trabalho foi avaliar a capacidade osteoregenerativa de biomateriais em diferentes composições, em tíbias de ovinos. Foram utilizadas oito ovelhas mestiças texel, com 12 meses de idade e peso médio de 28,5±7,4kg. Após adequada preparação anestésica e cirúrgica, foram produzidos três defeitos ósseos na diáfise das tíbias em sua face medial, totalizando seis defeitos de 6mm cada, sendo que quatro foram preenchidos por biomateriais, e dois por fragmentos ósseos retirados do próprio animal (autocontrole). Os materiais implantados foram: hidroxiapatita (HA), tricálcio fosfato-β (TCP-β), hidroxiapatita/tricálcio fosfato-b 60/40 (HA/TCP-b 60/40) e o nanocompósito hidroxiapatita/alumina a 5% (HA/Al2O3 a 5%). Os animais foram alocados em dois grupos: Grupo 60 (n=04), em que os animais foram eutanasiados após 60 dias da colocação dos implantes e Grupo 90 (n=04), em que a eutanásia ocorreu 90 dias após a colocação dos implantes. Foram realizadas radiografias nos períodos pré-operatório, imediatamente após o procedimento e aos 30, 60 e 90 dias de pós-operatório, a fim de excluir qualquer alteração prévia ou complicação pós-operatória, capaz de comprometer o estudo. Após a eutanásia, foram coletadas as tíbias para avaliação macro e microscópica, por meio de microscopia eletrônica de varredura (MEV) e microscopia óptica. Os resultados encontrados mostraram uma boa capacidade de neoformação óssea e uma lenta absorção da HA. O TCP-β foi rapidamente absorvido e apresentou boa capacidade osteoindutiva e osteocondutiva, sendo observada neoformação óssea no interior dos grânulos deste biomaterial. O composto bifásico HA/TCP-β (60/40) apresentou o melhor resultado a longo prazo, devido ao melhor controle na solubilização e liberação dos íons cálcio e fosfatos para o meio biológico durante o processo de neoformação óssea. O biomaterial nanocompósito HA/Al2O3 a 5% não apresentou resultados promissores neste estudo, e sugerem-se novas pesquisas a fim de investigar melhor o potencial e aplicabilidade deste novo biomaterial. Conclui-se que a hidroxiapatita, o tricálcio fosfato-β e a associação HA/TCP-β (60/40) apresentam excelente capacidade de reparação óssea, podendo ser utilizados como substitutos ósseos; a associação HA/TCP-β (60/40) é o melhor dentre os biomateriais estudados, pois apresenta velocidade de absorção intermediária em relação à HA e ao TCP-β isolados, fornecendo ainda uma sustentação adequada ao tecido neoformado; o biomaterial HA/Al2O3 5% se mostrou incompatível, provocando reação de rejeição por parte do hospedeiro e com insignificante formação de tecido ósseo, sugerindo novas pesquisas acerca deste material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some material aspects such as grain size, purity and anisotropy exert an important influence on surface quality, especially in single point diamond turning. The aim of this paper is to present and discuss some critical factors that can limit the accuracy of ultraprecision machining of non-ferrous metals and to identify the effects of them on the cutting mechanism with single point diamond tools. This will be carried out through observations of machined surfaces and chips produced using optical and scanning electron microscopy. Solutions to reduce the influence of some of these limiting factors related with the mechanism of generation of mirror-like surfaces will be discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon Fibre Reinforced Carbon (CFRC) Composites are increasing their applications due to their high strength and Young’s Modulus at high temperatures in inert atmosphere. Although much work has been done on processing and structure and properties relationship, few studies have addressed the modelling of mechanical properties. This work is divided in two parts. In the first part, a modelling of mechanical properties was carried out for two bi-directional composites using a model based on the Bernoulli-Euler theory for symmetric laminated beams. In the second part, acoustic emission (AE) was used as an auxiliary technique for monitoring the failure process of the composites. Differences in fracture behaviour are reflected in patterns of AE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper examines two passive techniques for vibration reduction in mechanical systems: the first one is based on dynamic vibration absorbers (DVAs) and the second uses resonant circuit shunted (RCS) piezoceramics. Genetic algorithms are used to determine the optimal design parameters with respect to performance indexes, which are associated with the dynamical behavior of the system over selected frequency bands. The calculation of the frequency response functions (FRFs) of the composite structure (primary system + DVAs) is performed through a substructure coupling technique. A modal technique is used to determine the frequency response function of the structure containing shunted piezoceramics which are bonded to the primary structure. The use of both techniques simultaneously on the same structure is investigated. The methodology developed is illustrated by numerical applications in which the primary structure is represented by simple Euler-Bernoulli beams. However, the design aspects of vibration control devices presented in this paper can be extended to more complex structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hemolytic profile of an artificial device chronically implanted in the cardiovascular system may represent the difference between the success and failure in its long-term performance. Last decades have witnessed efforts on the development of methods capable of predicting red blood cell damage in artificial organs. However, all of them have had limited success to predict hemolysis. The primary cause of this problem is that such models do not take into consideration structures of turbulent flow. The present paper demonstrates that microscopic measurable occurrences of the turbulent flow may be linked to red blood cell trauma. This study suggests that if the smallest turbulent eddies dimension is under 10 m m hemolysis is not dependent on the exposure time and the red blood cells damage depends only on the dissipation of the turbulent energy in the erythrocyte membrane. The analysis reported here opens the possibility of mapping the flow field in artificial assist devices based on the smallest eddy length scales. This is a promising new trend and should be considered in the designing requirements of the next generations of artificial organs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber reinforced polymer composites have been used in many applications, such as in automobile, aerospace and naval industries, due basically to their high strength-to-weight and modulus-to-weight, among other properties. Even though particles are usually not able to lead to the level of reinforcement of fibers, particle reinforced polymer composites have been proposed for many new applications due to their low cost, easy fabrication and isotropic properties. In this work, polymer composites were prepared by incorporating glass particles of different morphologies on poly(aryl sulfones) matrices. Particles with aspect ratios equal to 1, 2.5 and 10 were used. The prepared composites were characterized using electron microscopy and thermal analysis. Mechanical properties of the composites were evaluated using a four-point bending test. The thermo-mechanical behavior of the obtained composites was also investigated. The results showed that the morphology of the particles alter significantly the mechanical properties of composites. Particles with larger values of aspect ratio led to large elastic modulus but low levels of strain at failure. This result was explained by modeling the thermo-mechanical behavior of the composites using a viscoelastic model. Parameters of the model, obtained from a Cole-Cole type of plot, demonstrated that interactions at the polymer-reinforcing agent interface were higher for composites with large aspect ratio particles. Higher levels of interactions at interfaces can lead to higher degrees of stress transfer and, consequently, to composites with large elastic modulus, as experimentally observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High dimensional dynamical systems has intricate behavior either on temporal or on spatial evolution properties. Nevertheless, most of the work on chaotic dynamics has been concentrated on temporal behavior of low-dimensional systems. This contribution is concerned with the chaotic response of a two-degree of freedom Duffing oscillator. Since the equations of motion are associated with a five-dimensional system, the analysis is performed by considering two Duffing oscillators, both with single-degree of freedom, coupled by a spring-dashpot system. With this assumption, it is possible to analyze the transmissibility of motion between the two oscillators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a particular system is investigated consisting of a pendulum whose point of support is vibrated along a horizontal guide by a two bar linkage driven from a DC motor, considered as a limited power source. This system is nonideal since the oscillatory motion of the pendulum influences the speed of the motor and vice-versa, reflecting in a more complicated dynamical process. This work comprises the investigation of the phenomena that appear when the frequency of the pendulum draws near a secondary resonance region, due to the existing nonlinear interactions in the system. Also in this domain due to the power limitation of the motor, the frequency of the pendulum can be captured at resonance modifying completely the final response of the system. This behavior is known as Sommerfeld effect and it will be studied here for a nonlinear system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tropical high altitude grasslands present several species with both microphyllous and highly sclerophyllous leaves, and co-occur in specific soil patches, thus exposed to identical environments. In this article we describe herbivory among co-occurring microphyllous species in a tropical high altitude grassland ecosystem of Serra do Cipó, Minas Gerais state, and we tested the effect of variable anatomic traits on leaf herbivory patterns. Leaf anatomical traits were investigated for Baccharis imbricata Heering , Lavoisiera imbricata DC. and L. subulata Triana (focal species). Herbivory was measured from branches and leaves of individual plants and compared among co-occurring species within one multispecific shrub patch and among L. subulata individuals from this patch and an adjacent monospecific patch. For all present plant species and individuals we estimated the proportion of leaves with different levels of area lost. For the focal species, six leaves were sorted and taken for histological sectioning, in order to allow precise measures of defensive structures. Relative mean leaf area lost differed significantly among the six species found in the multispecific patch. Lavoisiera subulata individuals were more attacked in the multispecific than in the monospecific patch. Leaf margin protection traits in both B. imbricata and L. imbricata showed significant effect against herbivory. Data suggest that some anatomic traits have direct effect against herbivory but their effect are not clearly perceptible among branches within individual plants or among plants within the same species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of pain before it initiates may prevent the persistent pain-induced changes in the central nervous system that amplify pain long after the initial stimulus. The effects of pre- or postoperative intraperitoneal administration of morphine (2 to 8 mg/kg), dipyrone (40 and 80 mg/kg), diclofenac (2 to 8 mg/kg), ketoprofen (10 and 20 mg/kg), and tenoxicam (10 and 20 mg/kg) were studied in a rat model of post-incisional pain. Groups of 5 to 8 male Wistar rats (140-160 g) were used to test each drug dose. An incision was made on the plantar surface of a hind paw and the changes in the withdrawal threshold to mechanical stimulation were evaluated with Von Frey filaments at 1, 2, 6 and 24 h after the surgery. Tenoxicam was given 12 or 6 h preoperatively, whereas the remaining drugs were given 2 h or 30 min preoperatively. Postoperative drugs were all given 5 min after surgery. No drug abolished allodynia when injected before or after surgery, but thresholds were significantly higher than in control during up to 2 h following ketoprofen, 6 h following diclofenac, and 24 h following morphine, dipyrone or tenoxicam when drugs were injected postoperatively. Significant differences between pre- and postoperative treatments were obtained only with ketoprofen administered 30 min before surgery. Preoperative (2 h) intraplantar, but not intrathecal, ketoprofen reduced the post-incisional pain for up to 24 h after surgery. It is concluded that stimuli generated in the inflamed tissue, rather than changes in the central nervous system are relevant for the persistence of pain in the model of post-incisional pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physical forces affect both the function and phenotype of cells in the lung. Bronchial, alveolar, and other parenchymal cells, as well as fibroblasts and macrophages, are normally subjected to a variety of passive and active mechanical forces associated with lung inflation and vascular perfusion as a result of the dynamic nature of lung function. These forces include changes in stress (force per unit area) or strain (any forced change in length in relation to the initial length) and shear stress (the stress component parallel to a given surface). The responses of cells to mechanical forces are the result of the cell's ability to sense and transduce these stimuli into intracellular signaling pathways able to communicate the information to its interior. This review will focus on the modulation of intracellular pathways by lung mechanical forces and the intercellular signaling. A better understanding of the mechanisms by which lung cells transduce physical forces into biochemical and biological signals is of key importance for identifying targets for the treatment and prevention of physical force-related disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The continuous intravenous administration of isotopic bicarbonate (NaH13CO2) has been used for the determination of the retention of the 13CO2 fraction or the 13CO2 recovered in expired air. This determination is important for the calculation of substrate oxidation. The aim of the present study was to evaluate, in critically ill patients with sepsis under mechanical ventilation, the 13CO2 recovery fraction in expired air after continuous intravenous infusion of NaH13CO2 (3.8 µmol/kg diluted in 0.9% saline in ddH2O). A prospective study was conducted on 10 patients with septic shock between the second and fifth day of sepsis evolution (APACHE II, 25.9 ± 7.4). Initially, baseline CO2 was collected and indirect calorimetry was also performed. A primer of 5 mL NaH13CO2 was administered followed by continuous infusion of 5 mL/h for 6 h. Six CO2 production (VCO2) measurements (30 min each) were made with a portable metabolic cart connected to a respirator and hourly samples of expired air were obtained using a 750-mL gas collecting bag attached to the outlet of the respirator. 13CO2 enrichment in expired air was determined with a mass spectrometer. The patients presented a mean value of VCO2 of 182 ± 52 mL/min during the steady-state phase. The mean recovery fraction was 0.68 ± 0.06%, which is less than that reported in the literature (0.82 ± 0.03%). This suggests that the 13CO2 recovery fraction in septic patients following enteral feeding is incomplete, indicating retention of 13CO2 in the organism. The severity of septic shock in terms of the prognostic index APACHE II and the sepsis score was not associated with the 13CO2 recovery fraction in expired air.