97 resultados para Digital watermark


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this investigation was to demonstrate the feasibility of a biopsy technique by performing serial evaluations of tissue samples of the forelimb superficial digital flexor tendon (SDFT) in healthy horses and in horses subjected to superficial digital flexor tendonitis induction. Eight adult horses were evaluated in two different phases (P), control (P1) and tendonitis-induced (P2). At P1, the horses were subjected to five SDFT biopsies of the left forelimb, with 24 hours (h) of interval. Clinical and ultrasonographic (US) examinations were performed immediately before the tendonitis induction, 24 and 48 h after the procedure. The biopsied tendon tissues were analyzed through histology. P2 evaluations were carried out three months later, when the same horses were subjected to tendonitis induction by injection of bacterial collagenase into the right forelimb SDFT. P2 clinical and US evaluations, and SDFT biopsies were performed before, and after injury induction at the following time intervals: after 24, 48, 72 and 96 h, and after 15, 30, 60, 90, 120 and 150 days. The biopsy technique has proven to be easy and quick to perform and yielded good tendon samples for histological evaluation. At P1 the horses did not show signs of localised inflammation, pain or lameness, neither SDFT US alterations after biopsies, showing that the biopsy procedure per se did not risk tendon integrity. Therefore, this procedure is feasible for routine tendon histological evaluations. The P2 findings demonstrate a relation between the US and histology evaluations concerning induced tendonitis evolution. However, the clinical signs of tendonitis poorly reflected the microscopic tissue condition, indicating that clinical presentation is not a reliable parameter for monitoring injury development. The presented method of biopsying SDFT tissue in horses enables the serial collection of material for histological analysis causing no clinical signs and tendon damage seen by US images. Therefore, this technique allows tendonitis to be monitored and can be considered an excellent tool in protocols for evaluating SDFT injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: Fifty-five bursa of Fabricius (BF) were evaluated by optical microscopy for three different avian histopathologists (H1, H3 and H4) to determine the degree of lymphoid depletion. One histologist evaluated the same slides at two different times (H1 and H2) with four-months interval between the observations. The same BFs were evaluated using the system of Digital Lymphocyte Depletion Evaluation (ADDL), being performed by three differents operators of the system, not histopathologists. The results showed was a significant difference between the histopathologists and between the scores established by the same expert (H1 and H2). However, there were not significant differences between the scores with the ADDL system, obtained using ADDL. The results make clear the fragility of the subjective lymphocyte depletion score classification by the traditional histologic method, while the ADDL system proves to be more appropriated for the assessment of the lymphoid loss in the BF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract The digital cushion is characterized as a modified subcutaneous tissue that absorbs the shock during gait, assists venous return of the hoof and supports a considerable part of body weight. Digital cushions have particular importance in the pathogenesis of the hoof, since they need to properly work in order to prevent compression and traumas in soft tissues. This study aimed to measure and determine how is the arrangement of these structures, and for this it was established the proportions of connective, adipose, vascular tissues and collagen fibers and collagen types found in palmar and plantar digital cushion of bovine using fore and hindlimbs of twelve adult zebu cattle of both sexes, 11 male and one female, with 269kg average carcass weight and without limb disorders. Fragments of cushions were subjected to conventional histology, cut to a thickness of 4µm and stained with Red Picrosirius. With digital optical microscope, the quantification of the connective tissue and differentiation of types of collagen used the Image Pro Plus® software, and of adipose and vascular tissue, the test point system. The mean and standard error were estimated with the GraphPad Prism 5.0 software, and then data were subjected to Kolmogorov-Smirnov normality test and Student's t-test with significance level set at 5% for determining the amount of different tissues between fore and hindlimbs of studied animals. In forelimbs the mean and standard error of the connective tissue proportion was 50.10%+1.54, of the adipose tissue was 21.34%+1.44, and of vascular tissue was 3.43%+0.28. Hindlimbs presented a proportion of connective tissue of 61.61%+1.47, 20.66%+1.53 of adipose tissue, and 3.06%+0.20 of vascular tissue. A significant difference (p<0.001) was detected in the connective tissue proportion between fore and hindlimbs. Types I and II collagen fibers have presented, respectively, a proportion of 31.89% and 3.9% in forelimbs and 34.05% and 1.78% in hindlimbs. According to the used methodology, digital cushions had a clear differentiation relative to adipose tissue between fore and hindlimbs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Shadow Moiré fringe patterns are level lines of equal depth generated by interference between a master grid and its shadow projected on the surface. In simplistic approach, the minimum error is about the order of the master grid pitch, that is, always larger than 0,1 mm, resulting in an experimental technique of low precision. The use of a phase shift increases the accuracy of the Shadow Moiré technique. The current work uses the phase shifting method to determine the surfaces three-dimensional shape using isothamic fringe patterns and digital image processing. The current study presents the method and applies it to images obtained by simulation for error evaluation, as well as to a buckled plate, obtaining excellent results. The method hands itself particularly useful to decrease the errors in the interpretation of the Moiré fringes that can adversely affect the calculations of displacements in pieces containing many concave and convex regions in relatively small areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ventricular late potentials are low-amplitude signals originating from damaged myocardium and detected on the body surface by ECG filtering and averaging. Digital filters present in commercial equipment may interfere with the ability of arrhythmia stratification. We compared 40-Hz BiSpec (BI) and classical 40- to 250-Hz band-pass Butterworth bidirectional (BD) filters in terms of impact on time domain variables and diagnostic properties. In a transverse retrospective age-adjusted case-control study, 221 subjects with sinus rhythm without bundle branch block were divided into three groups after signal-averaged ECG acquisition: GI (N = 40), clinically normal controls, GII (N = 158), subjects with coronary heart disease without sustained monomorphic ventricular tachycardia (SMVT), and GIII (N = 23), subjects with heart disease and documented SMVT. Conventional variables analyzed from vector magnitude data after averaging to 0.3 µV final noise were obtained by application of each filter to the averaged signal, and evaluated in pairs by numerical comparison and by diagnostic agreement assessment, using conventional and optimized thresholds of normality. Significant differences were found between BI and BD variables in all groups, with diagnostic results showing significant disagreement between both filters [kappa value of 0.61 (P<0.05) for GII and 0.31 for GIII (P = NS)]. Sensitivity for SMVT was lower with BI than with BD (65.2 vs 91.3%, respectively, P<0.05). Filters provided significantly different numerical and diagnostic results and the BI filter showed only limited clinical application to risk stratification of ventricular arrhythmia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Important biological and clinical features of malignancy are reflected in its transcript pattern. Recent advances in gene expression technology and informatics have provided a powerful new means to obtain and interpret these expression patterns. A comprehensive approach to expression profiling is serial analysis of gene expression (SAGE), which provides digital information on transcript levels. SAGE works by counting transcripts and storing these digital values electronically, providing absolute gene expression levels that make historical comparisons possible. SAGE produces a comprehensive profile of gene expression and can be used to search for candidate tumor markers or antigens in a limited number of samples. The Cancer Genome Anatomy Project has created a SAGE database of human gene expression levels for many different tumors and normal reference tissues and provides online tools for viewing, comparing, and downloading expression profiles. Digital expression profiling using SAGE and informatics have been useful for identifying genes that have a role in tumor invasion and other aspects of tumor progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: Um dos maiores desafios no manejo da hipertensão arterial é o adequado controle pressórico. Para se alcançar esse objetivo tem se difundido a medida residencial da pressão arterial (MRPA) com aparelhos automáticos. Entretanto, parte da comunidade médico-científica ainda discute sua validade, acreditando que as medidas pressóricas domiciliares podem ser incorretas. OBJETIVO: Avaliar a correspondência entre as medidas simultâneas da pressão arterial (PA) pelo método auscultatório convencional e método digital automático, habitualmente utilizado na MRPA. MÉTODOS: Através de uma conexão em "Y" acoplamos um manguito a um aparelho digital automático validado (ONROM 705IT) e a um esfigmomanômetro de coluna de mercúrio, permitindo aferir simultaneamente a PA pelos dois métodos. Determinamos a PA em 423 indivíduos (normotensos e hipertensos), adequando o tamanho do manguito à circunferência braquial. RESULTADOS: Os valores representam média ± desvio padrão (DP) (valores mínimo-máximo): Idade 40,8 ± 16,3 anos (18-92), circunferência braquial 28,2 ± 3,7 cm (19-42), PA sistólica (PAS) auscultatório 127,6 ± 22,8 mmHg (69-223), PAS automático 129,5 ± 23,0 mmHg (56-226), PA diastólica (PAD) auscultatório 79,5 ± 12,6 mmHg (49-135), PAD automático 79,0 ± 12,6 mmHg (48-123). A diferença média da PAS entre os dois métodos foi de 1,9 mmHg (-15 a +19) e a diferença da PAD de 0,5 mmHg (-19 a +13). Os índices de correlação de Pearson entre os métodos são para a PAS (r = 0,97), e PAD (r = 0,91). A análise de Bland-Altman mostrou concordância clinicamente aceitável entre os métodos. CONCLUSÃO: A PA aferida pelo método digital automático apresenta boa concordância com o método auscultatório convencional, devendo ser usada no auxílio do diagnóstico e controle da hipertensão arterial (HA).