121 resultados para Diagnostic validity
Resumo:
Objective To evaluate the performance of diagnostic centers in the classification of mammography reports from an opportunistic screening undertaken by the Brazilian public health system (SUS) in the municipality of Goiânia, GO, Brazil in 2010. Materials and Methods The present ecological study analyzed data reported to the Sistema de Informação do Controle do Câncer de Mama (SISMAMA) (Breast Cancer Management Information System) by diagnostic centers involved in the mammographic screening developed by the SUS. Based on the frequency of mammograms per BI-RADS® category and on the limits established for the present study, the authors have calculated the rate of conformity for each diagnostic center. Diagnostic centers with equal rates of conformity were considered as having equal performance. Results Fifteen diagnostic centers performed mammographic studies for SUS and reported 31,198 screening mammograms. The performance of the diagnostic centers concerning BI-RADS classification has demonstrated that none of them was in conformity for all categories, one center presented conformity in five categories, two centers, in four categories, three centers, in three categories, two centers, in two categories, four centers, in one category, and three centers with no conformity. Conclusion The results of the present study demonstrate unevenness in the diagnostic centers performance in the classification of mammograms reported to SISMAMA from the opportunistic screening undertaken by SUS.
Resumo:
Objective To suggest a national value for the diagnostic reference level (DRL) in terms of activity in MBq.kg–1, for nuclear medicine procedures with fluorodeoxyglucose (18F-FDG) in whole body positron emission tomography (PET) scans of adult patients. Materials and Methods A survey on values of 18F-FDG activity administered in Brazilian clinics was undertaken by means of a questionnaire including questions about number and manufacturer of the installed equipment, model and detector type. The suggested DRL value was based on the calculation of the third quartile of the activity values distribution reported by the clinics. Results Among the surveyed Brazilian clinics, 58% responded completely or partially the questionnaire; and the results demonstrated variation of up to 100% in the reported radiopharmaceutical activity. The suggested DRL for 18F-FDG/PET activity was 5.54 MBq.kg–1 (0.149 mCi.kg–1). Conclusion The present study has demonstrated the lack of standardization in administered radiopharmaceutical activities for PET procedures in Brazil, corroborating the necessity of an official DRL value to be adopted in the country. The suggested DLR value demonstrates that there is room for optimization of the procedures and 18F-FDG/PET activities administered in Brazilian clinics to reduce the doses delivered to patients. It is important to highlight that this value should be continually revised and optimized at least every five years.
Resumo:
Objective To evaluate the knowledge about diagnostic imaging methods among primary care and medical emergency physicians. Materials and Methods Study developed with 119 primary care and medical emergency physicians in Montes Claros, MG, Brazil, by means of a structured questionnaire about general knowledge and indications of imaging methods in common clinical settings. A rate of correct responses corresponding to ≥ 80% was considered as satisfactory. The Poisson regression (PR) model was utilized in the data analysis. Results Among the 81 individuals who responded the questionnaire, 65% (n = 53) demonstrated to have satisfactory general knowledge and 44% (n = 36) gave correct responses regarding indications of imaging methods. Respectively, 65% (n = 53) and 51% (n = 41) of the respondents consider that radiography and computed tomography do not use ionizing radiation. The prevalence of a satisfactory general knowledge about imaging methods was associated with medical residency in the respondents' work field (PR = 4.55; IC 95%: 1.18-16.67; p-value: 0.03), while the prevalence of correct responses regarding indication of imaging methods was associated with the professional practice in primary health care (PR = 1.79; IC 95%: 1.16-2.70; p-value: 0.01). Conclusion Major deficiencies were observed as regards the knowledge about imaging methods among physicians, with better results obtained by those involved in primary health care and by residents.
Resumo:
Abstract Objective: To determine the rates of diagnostic underestimation at stereotactic percutaneous core needle biopsies (CNB) and vacuum-assisted biopsies (VABB) of nonpalpable breast lesions, with histopathological results of atypical ductal hyperplasia (ADH) or ductal carcinoma in situ (DCIS) subsequently submitted to surgical excision. As a secondary objective, the frequency of ADH and DCIS was determined for the cases submitted to biopsy. Materials and Methods: Retrospective review of 40 cases with diagnosis of ADH or DCIS on the basis of biopsies performed between February 2011 and July 2013, subsequently submitted to surgery, whose histopathological reports were available in the internal information system. Biopsy results were compared with those observed at surgery and the underestimation rate was calculated by means of specific mathematical equations. Results: The underestimation rate at CNB was 50% for ADH and 28.57% for DCIS, and at VABB it was 25% for ADH and 14.28% for DCIS. ADH represented 10.25% of all cases undergoing biopsy, whereas DCIS accounted for 23.91%. Conclusion: The diagnostic underestimation rate at CNB is two times the rate at VABB. Certainty that the target has been achieved is not the sole determining factor for a reliable diagnosis. Removal of more than 50% of the target lesion should further reduce the risk of underestimation.
Resumo:
Abstract Objective: To compare the diagnostic performance of the three-dimensional turbo spin-echo (3D TSE) magnetic resonance imaging (MRI) technique with the performance of the standard two-dimensional turbo spin-echo (2D TSE) protocol at 1.5 T, in the detection of meniscal and ligament tears. Materials and Methods: Thirty-eight patients were imaged twice, first with a standard multiplanar 2D TSE MR technique, and then with a 3D TSE technique, both in the same 1.5 T MRI scanner. The patients underwent knee arthroscopy within the first three days after the MRI. Using arthroscopy as the reference standard, we determined the diagnostic performance and agreement. Results: For detecting anterior cruciate ligament tears, the 3D TSE and routine 2D TSE techniques showed similar values for sensitivity (93% and 93%, respectively) and specificity (80% and 85%, respectively). For detecting medial meniscal tears, the two techniques also had similar sensitivity (85% and 83%, respectively) and specificity (68% and 71%, respectively). In addition, for detecting lateral meniscal tears, the two techniques had similar sensitivity (58% and 54%, respectively) and specificity (82% and 92%, respectively). There was a substantial to almost perfect intraobserver and interobserver agreement when comparing the readings for both techniques. Conclusion: The 3D TSE technique has a diagnostic performance similar to that of the routine 2D TSE protocol for detecting meniscal and anterior cruciate ligament tears at 1.5 T, with the advantage of faster acquisition.
Resumo:
To optimize the use of pesticides, several countries have carried out periodic inspections in agricultural sprayers. In Brazil, knowing the conditions of this machinery canguide researches and investments in guidelines for its use and maintenance. The objective of this study was to verify the state of sprayer maintenance used in the North of the state of Paraná, in Brazil. Several sprayer items were evaluated, such as: presence, status and scale of the manometer, status of the hose, status of the anti-drip component, presence of leaks, status of the bar, status of the filters, state of the spraying nozzles and errors in the targeted flow rate. Machines were named as approved when there was no failure in any item evaluated. The factor that caused the biggest level of reprove among the machines was incorrect scale of manometers, which reproved 84.55% of the machines evaluated. Other outstanding factor was the incorrect flow rate in 75.5% of the tested machines. Only one unit was approved from the total of 110 evaluated sprayers.
Resumo:
Forty-one wild house mice (Mus musculus) were trapped in an urban area, near railways, in Santa Fe city, Argentina. Both kidneys from each mouse were removed for bacteriological and histological examination. One kidney was inoculated into Fletcher semi-solid medium and isolates were serologically typed. The other kidney was microscopically examined after hematoxylin-eosin, silver impregnation and immunohistochemical stains. Leptospires, all of them belonging to the Ballum serogroup, were isolated from 16 (39%) out of 41 samples. The presence of the agent was recorded in 18 (44%) and in 19 (46%) out of 41 silver impregnated and immunohistochemically stained samples respectively. Additionally, leptospires were detected in high number on the apical surface of epithelial cells and in the lumen of medullary tubules and they were less frequently seen on the apical surface of epithelial cells or in the lumen of the cortical tubules, which represents an unusual finding in carrier animals. Microscopic lesions consisting of focal mononuclear interstitial nephritis, glomerular shrinkage and desquamation of tubular epithelial cells were observed in 13 of 19 infected and in 10 of 22 non-infected mice; differences in presence of lesions between infected and non-infected animals were not statistically significant (P=0,14). The three techniques, culture, silver impregnation and immunohistochemistry, had a high agreement (k³0.85) and no significant differences between them were detected (P>0.05). In addition, an unusual location of leptospires in kidneys of carrier animals was reported, but a relationship between lesions and presence of leptospires could not be established.
Resumo:
A study was conducted to evaluate the predictive diagnostic value of different copper (Cu) parameters as indicators of average daily gain (ADG) in growing calves. The effects in calves of cow Cu supplementation in the last one-third gestation period were also evaluated. Five supplementation trials, with a total of 300 calves, were carried out. Two groups of 30 calves were randomly assigned to each trial, one group was parenterally supplemented (SG) and the other was not supplemented (NSG). Trials began when calves were three-month-old and ended at weaning time. At each sampling calves were weighed and blood was taken to determine Cu concentrations in plasma, Whole Blood (WB), Red Cells (RC) and Packed Cell Volume (PCV). Liver samples from six animals of each group were taken both at the beginning and at the end of the trial. In two trials the mothers of the SG received Cu supplementation at the last one- third gestation period. Four of the five trials exhibited low ADG in the NSGs. In these groups, plasma Cu concentration decreased rapidly before low ADG was detected, which occurred with values remaining below 25µg/dl. The decrease of RC Cu concentration was considerably slow. WB showed an intermediate position. PCV in the SGs was higher than in the NSGs in all trials. Cow supplementation was insufficient to generate a liver storage able to last after calves reached the 3 months of age. These data could be useful to predict the risk of low ADG in grazing calves.
Resumo:
The aim of this study was to investigate the occurrence of Toxoplasma gondii and compare the results obtained in the Modified Agglutination Test (MAT), Polimerase Chain Reaction (PCR) and bioassay in mice. In order to accomplish this, 40 free-range chickens from eight farms in neighboring areas to the Pantanal in Nhecolândia, Mato Grosso do Sul, were euthanized and blood samples, brain and heart were collected. The occurrence of anti-T. gondii antibodies found in chickens was 67.5% (27 samples), considering as a cutoff point the dilution 1:5. Among the samples analyzed, 7 (25.9%) were positive in the dilution 1:5, 3 (11.1%) in 1:10, 2 (7.4%) in 1:20, 3 (11.1%) in 1:320, 1 ( 3.7%) in 1:640, 3 (11.1%) in 1:1280, 2 (7.4%) in 1:2560, 4 (14.8%) in 1:5120 and 2 (7.4%) in 1:10.240. From the mixture of tissue samples (brain and heart) from the chickens analyzed, 16 (40%) presented electrophoretic bands compatible with T. gondii by PCR (gene B1). In the comparison of techniques, 59.26% positivity in PCR was revealed among animals that were seropositive in MAT (cutoff 1:5). From 141 inoculated mice, six (4.44%) died of acute toxoplasmosis between 15 and 23 days after inoculation. Surviving mice were sacrificed at 74 days after inoculation, and a total of 28 cysts were found in the brains of 10 distinct groups. From the seropositive hens, 27 bioassays were performed and 11 (40.7%) isolates were obtained. A greater number of isolations happened in mice that were inoculated with tissues from chickens that had high titers for anti-T. gondii antibodies. Chronic infection in mice was observed in nine groups (33.3%) from five different properties. Among the surviving mice, 25.6% were positive for T. gondii in MAT (1:25). From mice positive in PCR, 87.5% were also positive in MAT. Among the PCR-negative mice, 5.2% were positive for T. gondii in MAT. It can be concluded through this study that the occurrence of infecton by T. gondii in the rural properties studied was high, that PCR directed to gene B1 does not confirm the viability of the parasite, but it can be used as a screening method for the selection of chickens infected by T. gondii, that the animals with titer greater than 10 must be prioritized for the selection of animals for bioassay, since for them, the chances of isolating the parasite are greater and that seroconversion in experimentally infected mice is not a good indicator for isolating the agent.
Resumo:
The Japanese quail Coturnix japonica originated from North Africa, Europe and Asia, is used worldwide as an experimental animal and model for aviculture. The current paper characterizes Eimeria bateri, Eimeria tsunodai and Eimeria uzura recovered from C. japonica. Based on the fact that quails have a global distribution, as are their coccidia, the findings of this study should provide the means for diagnosis of those Eimeria spp. in other regions and continents. Eimeria bateri showed the greatest intensity of infection and shed oocysts from the fourth day after infection; in contrast, E. tsunodai and E. uzura shed oocysts from the fifth day after infection. The three species shared a high degree of similarity and were all polymorphic. Yet, the application of line regressions, histograms and ANOVA provided means for the identification of these species. Finally, the algorithm was very efficient since verified that resultant values were not superimposed.
Resumo:
Several tools of precision agriculture have been developed for specific uses. However, this specificity may hinder the implementation of precision agriculture due to an increasing in costs and operational complexity. The use of vegetation index sensors which are traditionally developed for crop fertilization, for site-specific weed management can provide multiple utilizations of these sensors and result in the optimization of precision agriculture. The aim of this study was to evaluate the relationship between reflectance indices of weeds obtained by the GreenSeekerTM sensor and conventional parameters used for weed interference quantification. Two experiments were conducted with soybean and corn by establishing a gradient of weed interference through the use of pre- and post-emergence herbicides. The weed quantification was evaluated by the normalized difference vegetation index (NDVI) and the ratio of red to near infrared (Red/NIR) obtained using the GreenSeekerTM sensor, the visual weed control, the weed dry matter, and digital photographs, which supplied information about the leaf area coverage proportions of weed and straw. The weed leaf coverage obtained using digital photography was highly associated with the NDVI (r = 0.78) and the Red/NIR (r = -0.74). The weed dry matter also positively correlated with the NDVI obtained in 1 m linear (r = 0.66). The results indicated that the GreenSeekerTM sensor originally used for crop fertilization could also be used to obtain reflectance indices in the area between rows of crops to support decision-making programs for weed control.
Resumo:
Salivary cortisol is an index of plasma free cortisol and is obtained by a noninvasive procedure. We have been using salivary cortisol as a tool for physiological and diagnostic studies, among them the emergence of circadian rhythm in preterm and term infants. The salivary cortisol circadian rhythm in term and premature infants was established between 8 and 12 postnatal weeks. In the preterm infants the emergence of circadian rhythm was parallel to the onset of sleep rhythm. We also studied the use of salivary cortisol for screening for Cushing's syndrome (CS) in control and obese outpatients based on circadian rhythm and the overnight 1 mg dexamethasone (DEX) suppression test. Salivary cortisol was suppressed to less than 100 ng/dl after 1 mg DEX in control and obese patients. A single salivary cortisol measurement at 23:00 h and again after 1 mg DEX above the 90th percentile of the obese group values had sensitivity and specificity of 93 and 93% (23:00 h), and 91 and 94% (after DEX), respectively. The sensitivity improved to 100% when we combined both parameters. We also studied 11 CS children and 21 age-matched primary obese children for whom salivary cortisol sensitivity and specificity were 100/95% (23:00 h), and 100/95% (1 mg DEX), respectively. Similar to adults, sensitivity and specificity of 100% were obtained by combining 23:00 h and 1 mg DEX. The measurement of salivary cortisol is a useful tool for physiological studies and for the diagnosis of CS in children and adults on an outpatient basis.
Resumo:
The main characteristic of the nursing Interactive Observation Scale for Psychiatric Inpatients (IOSPI) is the necessity of interaction between raters and patients during assessment. The aim of this study was to evaluate the reliability and validity of the scale in the "real" world of daily ward practice and to determine whether the IOSPI can increase the interaction time between raters and patients and influence the raters' opinion about mental illness. All inpatients of a general university hospital psychiatric ward were assessed daily over a period of two months by 9 nursing aides during the morning and afternoon shifts, with 273 pairs of daily observations. Once a week the patients were interviewed by a psychiatrist who filled in the Brief Psychiatric Rating Scale (BPRS). The IOSPI total score was found to show significant test-retest reliability (interclass correlation coefficient = 0.83) and significant correlation with the BPRS total score (r = 0.69), meeting the criteria of concurrent validity. The instrument can also discriminate between patients in need of further inpatient treatment from those about to be discharged (negative predictive value for discharge = 0.91). Using this scale, the interaction time between nursing aides and patients increased significantly (t = 2.93, P<0.05) and their opinion about the mental illness changed. The "social restrictiveness" factor of the opinion scale about mental illness showed a significant reduction (t = 4.27, P<0.01) and the "interpersonal etiology" factor tended to increase (t = 1.98, P = 0.08). The IOSPI was confirmed as a reliable and valid scale and as an efficient tool to stimulate the therapeutic attitudes of the nursing staff.
Resumo:
The purpose of the present study was to validate the quantitative culture and cellularity of bronchoalveolar lavage (BAL) for the diagnosis of ventilator-associated pneumonia (VAP). A prospective validation test trial was carried out between 1992 and 1997 in a general adult intensive care unit of a teaching hospital. Thirty-seven patients on mechanical ventilation with suspected VAP who died at most three days after a BAL diagnostic procedure were submitted to a postmortem lung biopsy. BAL effluent was submitted to Gram staining, quantitative culture and cellularity count. Postmortem lung tissue quantitative culture and histopathological findings were considered to be the gold standard exams for VAP diagnosis. According to these criteria, 20 patients (54%) were diagnosed as having VAP and 17 (46%) as not having the condition. Quantitative culture of BAL effluent showed 90% sensitivity (18/20), 94.1% specificity (16/17), 94.7% positive predictive value and 88.8% negative predictive value. Fever and leukocytosis were useless for VAP diagnosis. Gram staining of BAL effluent was negative in 94.1% of the patients without VAP (16/17). Regarding the total cellularity of BAL, a cut-off point of 400,000 cells/ml showed a specificity of 94.1% (16/17), and a cut-off point of 50% of BAL neutrophils showed a sensitivity of 90% (19/20). In conclusion, BAL quantitative culture, Gram staining and cellularity might be useful in the diagnostic investigation of VAP.