84 resultados para ultrasound measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, we evaluated 42 wrists using the semi-quantitative scales power Doppler ultrasound (PDUS) and gray scale ultrasound (GSUS) with scores ranging from 0 to 3 and correlated the results with clinical, laboratory and radiographic data. Twenty-one patients (17 women and 4 men) with rheumatoid arthritis according to criteria of the American College of Rheumatology were enrolled in the study from September 2008 to July 2009 at Universidade Estadual de Campinas (UNICAMP). The average disease duration was 14 months. The patients were 66.6% Caucasians and 33.3% non-Caucasians, with a mean age of 42 and 41 years, respectively. A dorsal longitudinal scan was performed by ultrasound on the radiocarpal and midcarpal joints using GE LOGIQ XP-linear ultrasound and a high frequency (8-10 MHz) transducer. All patients were X-rayed, and the Larsen score was determined for the joints, with grades ranging from 0 to V. This study showed significant correlations between clinical, sonographic and laboratory data: GSUS and swollen right wrist (r = 0.546), GSUS of right wrist and swelling of left wrist (r = 0.511), PDUS of right wrist and pain in left wrist (r = 0.436), PDUS of right wrist and C-reactive protein (r = 0.466). Ultrasound can be considered a useful tool in the diagnosis of synovitis in early rheumatoid arthritis mainly when the anti-cyclic citrullinated peptide and rheumatoid factor are negative, and can lead to an early change in the therapeutic decision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Caco-2 cell line has been used as a model to predict the in vitro permeability of the human intestinal barrier. The predictive potential of the assay relies on an appropriate in-house validation of the method. The objective of the present study was to develop a single HPLC-UV method for the identification and quantitation of marker drugs and to determine the suitability of the Caco-2 cell permeability assay. A simple chromatographic method was developed for the simultaneous determination of both passively (propranolol, carbamazepine, acyclovir, and hydrochlorothiazide) and actively transported drugs (vinblastine and verapamil). Separation was achieved on a C18 column with step-gradient elution (acetonitrile and aqueous solution of ammonium acetate, pH 3.0) at a flow rate of 1.0 mL/min and UV detection at 275 nm during the total run time of 35 min. The method was validated and found to be specific, linear, precise, and accurate. This chromatographic system can be readily used on a routine basis and its utilization can be extended to other permeability models. The results obtained in the Caco-2 bi-directional transport experiments confirmed the validity of the assay, given that high and low permeability profiles were identified, and P-glycoprotein functionality was established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous assessment of verticality by means of rod and rod and frame tests indicated that human subjects can be more (field dependent) or less (field independent) influenced by a frame placed around a tilted rod. In the present study we propose a new approach to these tests. The judgment of visual verticality (rod test) was evaluated in 50 young subjects (28 males, ranging in age from 20 to 27 years) by randomly projecting a luminous rod tilted between -18 and +18° (negative values indicating left tilts) onto a tangent screen. In the rod and frame test the rod was displayed within a luminous fixed frame tilted at +18 or -18°. Subjects were instructed to verbally indicate the rod’s inclination direction (forced choice). Visual dependency was estimated by means of a Visual Index calculated from rod and rod and frame test values. Based on this index, volunteers were classified as field dependent, intermediate and field independent. A fourth category was created within the field-independent subjects for whom the amount of correct guesses in the rod and frame test exceeded that of the rod test, thus indicating improved performance when a surrounding frame was present. In conclusion, the combined use of subjective visual vertical and the rod and frame test provides a specific and reliable form of evaluation of verticality in healthy subjects and might be of use to probe changes in brain function after central or peripheral lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the effect of pulsed ultrasound therapy (UST) and antibothropic polyvalent antivenom (PAV) on the regeneration of mouse extensor digitorum longus muscle following damage by Bothrops jararacussu venom. Animals (Swiss male and female mice weighing 25.0 ± 5.0 g; 5 animals per group) received a perimuscular injection of venom (1 mg/kg) and treatment with UST was started 1 h later (1 min/day, 3 MHz, 0.3 W/cm², pulsed mode). Three and 28 days after injection, muscles were dissected and processed for light microscopy. The venom caused complete degeneration of muscle fibers. UST alone and combined with PAV (1.0 mL/kg) partially protected these fibers, whereas muscles receiving no treatment showed disorganized fascicules and fibers with reduced diameter. Treatment with UST and PAV decreased the effects of the venom on creatine kinase content and motor activity (approximately 75 and 48%, respectively). Sonication of the venom solution immediately before application decreased the in vivo and ex vivo myotoxic activities (approximately 60 and 50%, respectively). The present data show that UST counteracts some effects of B. jararacussu venom, causing structural and functional improvement of the regenerated muscle after venom injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple experimental protocol applying a quantitative ultrasound (QUS) pulse-echo technique was used to measure the acoustic parameters of healthy femoral diaphyses of Wistar rats in vivo. Five quantitative parameters [apparent integrated backscatter (AIB), frequency slope of apparent backscatter (FSAB), time slope of apparent backscatter (TSAB), integrated reflection coefficient (IRC), and frequency slope of integrated reflection (FSIR)] were calculated using the echoes from cortical and trabecular bone in the femurs of 14 Wistar rats. Signal acquisition was performed three times in each rat, with the ultrasound signal acquired along the femur's central region from three positions 1 mm apart from each other. The parameters estimated for the three positions were averaged to represent the femur diaphysis. The results showed that AIB, FSAB, TSAB, and IRC values were statistically similar, but the FSIR values from Experiments 1 and 3 were different. Furthermore, Pearson's correlation coefficient showed, in general, strong correlations among the parameters. The proposed protocol and calculated parameters demonstrated the potential to characterize the femur diaphysis of rats in vivo. The results are relevant because rats have a bone structure very similar to humans, and thus are an important step toward preclinical trials and subsequent application of QUS in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although 17β-estradiol (E2) deficiency has been linked to the development of osteoarthritis (OA) in middle-aged women, there are few studies relating other estrogens and estrogen metabolites (EMs) to this condition. We developed a high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) method to measure the levels of six EMs (i.e., estrone, E2, estriol, 2-hydroxyestrone, 2-hydroxyestradiol, and 16a-hydroxyestrone) in healthy pre- and postmenopausal women and women with OA. This method had a precision ranging from 1.1 to 3.1% and a detection limit ranging from 10 to 15 pg. Compared to healthy women, serum-free E2 was lower in the luteal and postmenopausal phases in women with OA, and total serum E2 was lower in postmenopausal women with OA. Moreover, compared to healthy women, total serum 2-hydroxyestradiol was higher in postmenopausal women with OA and total serum 2-hydroxyestrone was lower in both the luteal and follicular phases in women with OA. In conclusion, our HPLC-ESI-MS/MS method allowed the measurement of multiple biochemical targets in a single assay, and, given its increased cost-effectiveness, simplicity, and speed relative to previous methods, this method is suitable for clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effect of ultrasound treatment on carrot juice was investigated through measuring pH, electrical conductivity, viscosity, visual color, total soluble solids, total sugars, total carotenoids, ascorbic acid contents and microbial load. No significant effect (p>0.05) of ultrasound treatment on pH of carrot juice was observed. Electrical conductivity, viscosity and color values gradually increased (p<0.05) with treatment time increase. Total soluble solids, total sugars, total carotenoids and ascorbic acid contents of carrot juice were significantly improved (p<0.05) due to ultrasound treatment. Moreover, significant decrease (p<0.05) in microbial load of sonicated carrot juice was observed. Results from present study suggested that ultrasound treatment could improve quality and safety of carrot juice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper builds up from a review of some expected, but other quite surprising results regarding country estimates for the year 2000 of genuine saving, a sustainability indicator developed by a World Bank research team. We examine this indicator, founded on neoclassical welfare theory, and discuss one of its major problems. Theoretical developments from ecological economics are then considered, together with insights from Georgescu-Roegen's approach to the production process, in search for an alternative approach. A model with potentially fruitful contributions in this direction is reviewed; it points the course efforts could take enable sustainability evaluations based on a more realistic set of interrelated monetary and biophysical indicators.