103 resultados para gini and concentration indices
Resumo:
This paper describes total lipid content, unsaponifiable fraction and the acid, refractive, saponification and iodine indices of the oil of Sterculia striata nuts. The fatty acids, the sterols and the triterpene alcohols were determined. The percentage of cyclopropenoid fatty acids (CPFA), determined by NMR ¹H (15,5%), makes the nuts of this species unsuitable for human consumption.
Resumo:
This is a review about the use of Blue rayon in the extraction and concentration of environmental contaminants in the aquatic environment. Blue rayon is an adsorbent composed of fibers covalently linked with copper phthalocyanine trisulphonate that has the ability to selectively adsorb polycyclic compounds. Blue rayon can be used in situ, in columns or in flasks. This method showed to be efficient in the extraction of important classes of environmental contaminants like the polycyclic aromatic hydrocarbons (PAHs), aromatic amines and phenylbenzotriazoles (PBTAs) and can be an important tool in monitoring studies for the evaluation of water quality.
Resumo:
Vitamin C stability and concentration was evaluated in isotonic beverages and B group vitamins (B1, B2, B3, B5 and B6) in power beverages. The amount of vitamins was found to be above of that declared on the labels, even after the shelf life had been exceeded. A small decrease in the amount of B group vitamins was observed during the shelf life of the products. In the case of vitamin C this decrease was slightly higher. The present research shows the need of increased quality control and inspection.
Resumo:
In this work commercial filters papers were organomodified with tetraethylorthosilicate (TEOS) and 3-aminopropyltriethoxysilane (3-APTS), aiming at the development of a new analytical procedure for in-situ speciation of labile and inert metal species in aquatic systems. Parameters that exert influence on the metal lability such as pH, chelating time, concentration and characteristics of the organic matter were studied in the laboratory using tests for metal recuperation. The results showed slower kinetics for Cu ion than for Ni, Mn and Cd in the absence of aquatic humic substances (AHS). The relative lability observed for complexed metals in aquatic humic substances using organomodified filter papers was Cu>>Cd>Ni>Mn. The pH values, structural characteristics and concentration of AHS exert strong influence on the lability of the metals. The results obtained showed that the utilization of organomodified filter papers can be an interesting and promising alternative for in situ characterization of metal lability in aquatic systems.
Resumo:
A method for HPLC determination of sulfadimethoxyne in milk is presented. The analyte isolation and concentration were performed by solid-phase extraction through a C-8 cartridge, pre-conditioned with hexane, methanol and water and eluted with MeOH. The recovery determination was done with a spiked solution of 20, 50 or 100 µg L-1. In this concentration range, the recovery was 83.2% with a RDS of 15.4%. For quantification, a Zorbax Eclipse XDB-C8 (4.6 mm x 150 mm, 5 µm), a mobile phase of MeCN: 0.01 mol L-1 KH2PO4 aq. (1:4), and a variable wavelength detector (275 nm) were used.
Resumo:
Samples of LDPE/modified starch blends 80/20 m/m before and after exposure to gamma rays were examined by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction. The effect of gamma radiation is clearly seen in the samples irradiated at a dose of 25 kGy. The main alteration in the polymeric material after exposure at the radiation range was a decrease in the mechanical properties, alterations in the chemical structure of the blend with an increase in the carbonyl and vinyl indices and the appearance of new crystalline symmetry generating a crystalline domain not existing before in the blend.
Resumo:
Anthocyanins are among the most important plant pigments. Due to their potential benefits for human health, there is considerable interest in these natural pigments. Nonetheless, there is great difficulty in finding a technique that could provide the identification of structurally similar compounds and estimate the number and concentration of the species present. A lot of techniques have been tried to find the best methodology to extract information from these systems. In this paper, a review of the most important procedures is given, from the extraction to the identification of anthocyanins in natural extracts.
Resumo:
This work presents a study on the separation of Fe(III) and Ti(IV) from sulfuric acid leaching solutions of ilmenite (FeTiO3) using liquid-liquid extraction with D2EHPA in n-dodecane as extracting agent. The distribution coefficients (K D) of the elements related to free acidity and concentration of Fe(III) and Ti(IV) were determined. Free acidity was changed from 3x10-2 to 11.88 mol L-1 and D2EHPA concentration was fixed at 1.5 mol L-1. Recovery of final products as well as recycling of wastes generated in the process were also investigated. The LLE process as a feasible alternative to obtain high-purity TiO2.
Resumo:
In this work, a new adsorbent was prepared by microencapsulation of sulfoxine into chitosan microspheres by the spray drying technique. The new adsorbent was characterized by Raman spectroscopy, scanning electron microscopy and microanalysis of energy dispersive X-rays. The Cu(II) adsorption was studied as a function of pH, time and concentration. The optimum pH was found to be 6.0. The kinetic and equilibrium data showed that the adsorption process followed the pseudo second-order kinetic model and the Langmuir isotherm model over the entire concentration range. An increase of 8.0% in the maximum adsorption capacity of the adsorbent (53.8 mg g-1) was observed as compared to chitosan glutaraldehyde cross-linked microspheres.
Resumo:
An enzymatic method was used for obtaining protein extracts from wheat flour using an alkaline protease. Some parameters were evaluated aiming the optimization of this method: temperature (40-50 ºC); time (2-5 h); physical treatment of the sample (no treatment, ultra-turrax/16,000 rpm/5 min and ultrasound/120 W/10 min); enzyme:substrate ratio (E:S) of 5:100 - 10:100 and concentration of wheat flour (1:3, 1:5 and 1:10 w/v). The results showed that the best condition for protein extraction was that using the sample concentration of 1:3 (w/v), ultra-turrax, E:S of 10:100, at 40 ºC, 2 h, having reached an extraction yield of 88.53%.
Resumo:
A study of the different hydrocarbon reactions over Ni doped WO3-ZrO2 catalysts was performed. Ni was found as NiO at low Ni concentration while at high Ni concentrations a small fraction was present as a metal. For both cases, Ni strongly modified total acidity and concentration of strong acid sites. In the cyclohexane dehydrogenation reaction, Ni addition promotes both benzene and methyl cyclopentane production. The hydroconversion activity (n-butane and n-octane) increases with the augment of total acidity produced by Ni. The selectivity to reaction products is modified according to the acid strength distribution changes produced by Ni addition.
Resumo:
The aim of this work was to produce biosurfactants through submerged fermentation using microorganisms isolated from soil contaminated with diesel. Microorganisms were isolated, characterized by the production of biosurfactants, and used to study the influence of type, induction and concentration of ammonium sulfate as a nitrogen source in the culture medium. The microorganisms that showed best results, in terms of production of biosurfactants, were identified as being of the genus Pseudomonas and Bacillus. The biosurfactants produced proved capable of reducing the surface tension of the media to 39 mN/m and 34 mN/m, respectively. Higher biosurfactant production was obtained in the medium containing 1% soybean oil without ammonium sulfate.
Resumo:
Activated carbon was produced from the water hyacinth (CAA) by impregnation with ZnCl2 (1:2), followed by pyrolysis at 700 ºC, under N2. CAA was used for the adsorption of phenol, m-cresol and o-cresol from aqueous solutions, using batch adsorption. The effects of contact time, pH, temperature and concentration on sorption were investigated. Adsorption capacity, calculated using the Langmuir model proved to be dependent on temperature, reaching values of 163.7, 130.2 and 142.3 mg g-1 for phenol, m-cresol and o-cresol, respectively, at 45 ºC. Thermodynamic data at the solid-liquid interface suggests an endothermic, spontaneous and environmentally-friendly process.
Resumo:
Multivariate Curve Resolution with Alternating Least Squares (MCR-ALS) is a resolution method that has been efficiently applied in many different fields, such as process analysis, environmental data and, more recently, hyperspectral image analysis. When applied to second order data (or to three-way data) arrays, recovery of the underlying basis vectors in both measurement orders (i.e. signal and concentration orders) from the data matrix can be achieved without ambiguities if the trilinear model constraint is considered during the ALS optimization. This work summarizes different protocols of MCR-ALS application, presenting a case study: near-infrared image spectroscopy.
Resumo:
Electrodegradation of atrazine in water was performed using homemade (PA and PB) and purchased (PC) boron-doped diamond anodes. The degradation was monitored off-line by analyzing total organic carbon and high performance liquid chromatography with diode array detector (HPLC-DAD) and at-line by UV spectroscopy. The spectra were recorded every 2 min. The rank deficiency problem was resolved by assembling an augmented column-wise matrix. HPLC was employed to separate the original and byproducts degradation components. Aiming the same goal, multivariate curve resolution - alternating least squares (MCR-ALS) was applied to resolve the UV spectroscopic data. Comparison between HPLC and MCR-ALS separations is presented. By using MCR-ALS the spectra of atrazine and two byproducts were successfully resolved and the resulted concentration profiles properly represented the system studied. The ALS explained variance (R2) for PA, PB and PC was equal to 99.99% for all of them and the lack of fit for PA, PB and PC were 0.39, 0.34 and 0.54 respectively. The correlation (R) between the recovered and pure spectra were calculate for each electrodegradation, validating the MCR-ALS results. The average R was equal to 0.997. The spectral and concentration profiles described with this new approach are in agreement with HPLC-DAD results. The proposed method is an alternative to classical analyses for monitoring of the degradation process, mainly due to the simplicity, fast results and economy.