92 resultados para extraction methods
Canine visceral leishmaniasis: study of methods for the detection of IgG in serum and eluate samples
Resumo:
The Brazilian Ministry of Health recommends the culling and euthanasia of dogs with a positive serological test for canine visceral leishmaniasis (CVL). In the Municipality of Rio de Janeiro, the technique used for the diagnosis of CVL is the indirect fluorescent antibody test (IFAT), using blood samples eluted on filter paper (eluate). A dog survey was conducted over a period of one year in the region of Carapiá, in order to evaluate the diagnosis of CVL in this region. All animals underwent clinical examination, and blood samples (serum and eluate) were collected for analysis by enzyme immunoassay (ELISA) and IFAT. A skin biopsy was obtained for parasitological examination (culture). A total of 305 animals were studied and Leishmania chagasi was isolated from nine animals. Sensitivity and specificity were 100% and 96.6% for ELISA, respectively, 100% and 65.5% for IFAT (cut-off at a 1:40 dilution), 100% and 83.4% for IFAT (cut-off at a 1:80 dilution), and 22.2% and 97.0% for eluate IFAT. In conclusion, ELISA was the best tool for the diagnosis of CVL among the serological techniques tested. The present results suggest the need for a better evaluation of filter paper IFAT as the only diagnostic method for CVL in the Municipality of Rio de Janeiro.
Resumo:
Adenovirus (AdV) respiratory infections are usually described as being associated with high mortality rates. Laboratory diagnosis is essential for the establishment of the appropriate therapy, and for guiding the implementation of preventive measures in order to prevent the spread of the infection. Aiming to analyze the sensitivity and specificity of the laboratorial diagnosis methods available, we compared antigen detection by indirect immunofluorescence assay (IF), and a specific nested polymerase chain reaction (PCR), to detect AdV in respiratory samples collected from patients admitted to hospital with acute respiratory disease. Positive samples were inoculated into a cell culture to confirm the results. We analyzed 381 samples from the nasopharyngeal aspirates collected during the year 2008; of these, 2.6% tested were positive for adenovirus through IF and 10% through PCR; positive isolation was obtained in 40% and 26% of these cases, respectively. Most infected patients were children under six months of age, and despite of the fact that a significant number of patients required intensive care, the mortality rate was low (5%). In conclusion, molecular methods were found to be useful for rapid diagnosis of adenovirus infections with higher sensitivity than antigen detection; their introduction permitted a significant increase in diagnoses of adenovirus infections.
Resumo:
Respiratory virus infections are the main cause of infant hospitalization and are potentially severe in children with congenital heart disease (CHD). Rapid and sensitive diagnosis is very important to early introduction of antiviral treatment and implementation of precautions to control transmission, reducing the risk of nosocomial infections. In the present study we compare different techniques in the diagnosis of respiratory viruses in CHD infants. Thirty-nine samples of nasopharyngeal aspirate were obtained from CHD infants with symptoms of respiratory infection. The Multiplex PCR (Seeplex® RV 12 ACE Detection) driven to the detection of 12 respiratory viruses was compared with the direct immunofluorescence assay (DFA) and PCR, both targeting seven respiratory viruses. The positivity found by DFA, Multiplex and PCR was 33.3%, 51.3% and 48.7%, respectively. Kappa index comparing DFA and Multiplex, DFA and PCR and PCR and Multiplex PCR was 0.542, 0.483 and 0.539, respectively. The concordance between techniques was considered moderate. Both Multiplex PCR (p = 0.001) and PCR (p = 0.002) detected significantly more respiratory virus than DFA. As the performance of the tests may vary, the combination of two or more techniques may increase diagnostic sensitivity favoring the diagnosis of co-infections, early introduction of antiviral therapy and implementation of appropriate measures.
Resumo:
Schistosomiasis constitutes a major public health problem, with an estimated 200 million individuals infected worldwide and 700 million people living in risk areas. In Brazil there are areas of high, medium and low endemicity. Studies have shown that in endemic areas with a low prevalence of Schistosoma infection the sensitivity of parasitological methods is clearly reduced. Consequently diagnosis is often impeded due to the presence of false-negative results. The aim of this study is to present the PCR reamplification (Re-PCR) protocol for the detection of Schistosoma mansoni in samples with low parasite load (with less than 100 eggs per gram (epg) of feces). Three methods were used for the lysis of the envelopes of the S. mansoni eggs and two techniques of DNA extraction were carried out. Extracted DNA was quantified, and the results suggested that the extraction technique, which mixed glass beads with a guanidine isothiocyanate/phenol/chloroform (GT) solution, produced good results. PCR reamplification was conducted and detection sensitivity was found to be five eggs per 500 mg of artificially marked feces. The results achieved using these methods suggest that they are potentially viable for the detection of Schistosoma infection with low parasite load.
Resumo:
Methicillin-resistant Staphylococcus aureus (MRSA) are now a worldwide problem. Cystic fibrosis (CF) patients are commonly colonized and infected by MRSA. Accurate oxacillin susceptibility testing is mandatory for the adequate management of these patients. We performed a comparison of the accuracy of different tests in CF isolates, including methicillin-susceptible S. aureus and MRSA with different SCCmec types, and using the mecA gene as the gold-standard. The sensitivity and specificity of oxacillin disc, Etest, and oxacillin agar screening plate were 100%. Sensitivity of the cefoxitin disc was 85% and specificity was 100%. For clinically relevant isolates, laboratories may consider the use of a combination of two phenotypic methods.
Resumo:
INTRODUCTION: Methicillin-Resistant Staphylococcus aureus (MRSA) presenting reduced susceptibility to vancomycin has been associated to therapeutic failure. Some methods used by clinical laboratories may not be sufficiently accurate to detect this phenotype, compromising results and the outcome of the patient. OBJECTIVES: To evaluate the performance of methods in the detection of vancomycin MIC values among clinical isolates of MRSA. MATERIAL AND METHODS: The Vancomycin Minimal Inhibitory Concentration was determined for 75 MRSA isolates from inpatients of Mãe de Deus Hospital, Porto Alegre, Brazil. The broth microdilution (BM) was used as the gold-standard technique, as well as the following methods: E-test® strips (BioMérieux), M.I.C.E® strips (Oxoid), PROBAC® commercial panel and the automated system MicroScan® (Siemens). Besides, the agar screening test was carried out with 3 µg/mL of vancomycin. RESULTS: All isolates presented MIC ≤ 2 µg/mL for BM. E-test® had higher concordance (40%) in terms of global agreement with the gold standard, and there was not statistical difference among E-test® and broth microdilution results. PROBAC® panels presented MICs, in general, lower than the gold-standard panels (58.66% major errors), while M.I.C.E.® MICs were higher (67.99% minor errors). CONCLUSIONS: For the population of MRSA in question, E-test® presented the best performance, although with a heterogeneous accuracy, depending on MIC values.
Resumo:
SUMMARY Infection by Candidaspp. is associated with high mortality rates, especially when treatment is not appropriate and/or not immediate. Therefore, it is necessary to correctly identify the genus and species of Candida. The aim of this study was to compare the identification of 89 samples of Candida spp. by the manual methods germ tube test, auxanogram and chromogenic medium in relation to the ID 32C automated method. The concordances between the methods in ascending order, measured by the Kappa index were: ID 32C with CHROMagar Candida(κ = 0.38), ID 32C with auxanogram (κ = 0.59) and ID 32C with germ tube (κ = 0.9). One of the species identified in this study was C. tropicalis,which demonstrated a sensitivity of 46.2%, a specificity of 95.2%, PPV of 80%, NPV of 81.1%, and an accuracy of 80.9% in tests performed with CHROMagar Candida;and a sensitivity of 76.9%, a specificity of 96.8%, PPV of 90.9%, NPV of 91%, and an accuracy of 91% in the auxanogram tests. Therefore, it is necessary to know the advantages and limitations of methods to choose the best combination between them for a fast and correct identification of Candidaspecies.
Resumo:
Trichomonas vaginalis is the etiologic agent of trichomoniasis, the most common non-viral sexually transmitted disease (STD) in the world. The diagnosis is based on wet mount preparation and direct microscopy on fixed and stained clinical specimens. The aim of this study was to compare the performance of different fixing and staining techniques used in the detection of T. vaginalis in urine. The smears were fixed and submitted to different methods of permanent staining and then, the morphological aspects of the parasites were analyzed and compared. The Papanicolaou staining with ethanol as the fixative solution showed to be the best method of permanent staining. Our data suggest that staining techniques in association with wet mount examination of fresh specimens contribute to increase the sensitivity in the diagnosis of trichomoniasis.
Resumo:
Através da prova de 7 dias foi estudado o grau de resistência do Plasmodium falciparum à cloroquina, amodiaquina e sulfadoxina-pirimetamina em Porto Velho, Estado de Rondônia, Brasil. Não se observaram diferenças significativas nas médias de parasitas nos dias de seguimento e nas proporções de resistência entre os três medicamentos testados, fazendo com que os autores recomendem a manutenção das 4-aminoquinoleínas como drogas a serem usadas atualmente em infecções não graves por P. falciparum na área de Porto Velho.
Resumo:
The purpose of this study was to compare the agar dilution and broth microdilution methods for determining the minimum inhibitory concentration (MIC) of fluconazole, itraconazole, ketoconazole, griseofulvin and terbinafine for 60 dermatophyte samples belonging to the species Trichophyton rubrum, Trichophyton mentagrophytes and Microsporum canis. The percentage agreement between the two methods, for all the isolates with < 2 dilutions that were tested was 91.6% for ketoconazole and griseofulvin, 88.3% for itraconazole, 81.6% for terbinafine and 73.3% for fluconazole. One hundred percent agreement was obtained for Trichophyton mentagrophytes isolates evaluated with ketoconazole and griseofulvin. Thus, until a reference method for testing the in vitro susceptibility of dermatophytes is standardized, the similarity of the results between the two methods means that the agar dilution method may be useful for susceptibility testing on these filamentous fungi.
Resumo:
INTRODUCTION: Considering that alternative antigens for diagnosing neurocysticercosis continue to be a challenge because of the increasing difficulty in obtaining parasites from naturally infected pigs for preparation of Taenia solium homologous antigen, the aim of the present study was to evaluate the detergent (D) and aqueous (A) fractions from saline extract of Taenia saginata metacestodes for diagnosing neurocysticercosis. METHODS: Taenia saginata was obtained from naturally infected bovines in the Triângulo Mineiro region, State of Minas Gerais, Brazil. The carcasses came from cold storage units and had been slaughtered in accordance with the inspection technique recommended by the Federal Inspection Service. The D and A fractions were obtained by using Triton X-114 (TX-114). Serum samples were obtained from 40 patients with a diagnosis of neurocysticercosis, 45 with other parasitic diseases and 30 from apparently normal individuals. IgG antibody levels were evaluated using the ELISA and immunoblotting assays. RESULTS: The ELISA sensitivity and specificity were 95% and 73.3%, when using saline extract; 95% and 82.6% for the D fraction; and 65% and 61.3% for the A fraction, respectively. The immunoblotting assay confirmed the ELISA results, such that the D fraction was more efficient than the other extracts, and the 70-68kDa component was immunodominant among neurocysticercosis patients. CONCLUSIONS: These results demonstrated that the D fraction from Taenia saginata metacestodes obtained using TX-114 can be used as a heterologous antigenic fraction in the immunoblotting assay for serologically diagnosing human neurocysticercosis, given its ability to select immunodominant antigens.
Resumo:
INTRODUCTION: Fungal infections in human skin, such as sporotrichosis, can occur after fish induced trauma. This work aimed to identify fungi in freshwater fish that are pathogenic to humans. METHODS: Extraction of dental arches from Serrassalmus maculatus (piranha) and Hoplias malabaricus (wolf fish), stings from Pimelodus maculatus (mandis catfish), dorsal fin rays from Plagioscion spp. (corvina) and Tilapia spp., for culture in Mycosel agar. Some cultures were submitted to DNA extraction for molecular identification by sequencing ITS-5.8S rDNA. RESULTS: Cultures identified most yeast as Candida spp., while sequencing also permitted the identification of Phoma spp. and Yarrowia lipolytica. CONCLUSIONS: While the search for S. schenckii was negative, the presence of fungus of the genera Phoma and Candida revealed the pathogenic potential of this infection route. The genus Phoma is involved in certain forms of phaeohyphomycosis, a subcutaneous mycosis caused by dematiaceous fungi, with reports of infections in human organs and systems. Traumatizing structures of some freshwater fish present pathogenic fungi and this may be an important infection route that must be considered in some regions of Brazil, since there are a large number of a fisherman in constant contact with traumatogenic fish.
Resumo:
INTRODUCTION: The present study compares human landing catches of primary malaria vectors with two alternative methods of capture: the Shannon trap and the Mosquito magnet. METHODS: This study used regression models to adjust capture data to a negative binominal distribution. RESULTS: Capture numbers and relative percentages obtained from the three methods vary strongly between species. The highest overall captures were obtained for Anopheles triannulatus with captures for the Shannon trap and the Mosquito magnet measuring more than 330% higher than captures obtained by human landings. For Anopheles darlingi, captures by the Shannon trap and the Mosquito magnet were about 14% and 26% of human landing catches, respectively. Another species with malaria transmission potential that was not sampled by human landing captures weascaptured by the Shannon trap and the Mosquito magnet (Anopheles oswaldoi). Both alternative sampling techniques can predict the human landing of Anopheles triannulatus, but without proportionality. Models for Anopheles darlingi counts, after totaling daily captures, are significant and proportional, but prediction models are more reliable when using the Shannon trap compared with the Mosquito magnet captures. CONCLUSIONS: These alternative capture methods can be partially recommended for the substitution of human landing captures or, at least, as complementary forms of monitoring for malarial mosquitoes.
Resumo:
INTRODUCTION: The production of anti-Cryptosporidium polyclonal antibodies and its use in direct immunofluorescence assays to determine the presence of Cryptosporidium in water are described in the present work. METHODS: Two rabbits were immunized with soluble and particulate antigens from purified Cryptosporidium oocysts. The sera produced were prepared for immunoglobulin G extraction, which were then purified and conjugated with fluorescein isothiocyanate (FITC). Slides containing known amounts of oocysts were prepared to determine the sensitivity of the technique. To test the specificity, slides containing Giardia duodenalis cysts were prepared. RESULTS: The conjugate was successfully used in water samples experimentally contaminated with Cryptosporidium oocysts, and it was possible to detect up to five oocysts/spot, corresponding to contamination of 250 oocysts/mL. CONCLUSIONS: The three immunizations performed in the rabbits were enough to produce antibodies against Cryptosporidium, the standard direct immunofluorescence assay permitted the detection of five oocysts in 20% of the samples, and no cross-reaction with Giardia duodenalis cysts occurred.