145 resultados para diameter
Resumo:
OBJECTIVE: To report the role played by transesophageal echocardiography during implantation of self-expanding aortic endoprostheses (stent) at a hemodynamics laboratory. METHODS: Thirteen patients underwent stent implantation in the descending thoracic aorta with the aid of transesophageal echocardiography during the entire procedure. Indications for stenting were as follows: 8 aortic dissections, 2 true aneurysms, 2 penetrating atherosclerotic ulcers, and 1 traumatic pseudoaneurysm. RESULTS: No complications resulting from the use of transesophageal echocardiography were observed. In 12 patients, the initial result was considered appropriate, with total or partial resolution of the major lesion confirmed by a posterior examination. In 1 patient, the procedure was suspended after transesophageal echocardiography and angiography showed that the proximal aortic diameter was inappropriate. Transesophageal echocardiography contributed to clarifying relevant points, such as aortic diameter, anatomic detail of the intimal lesion, and location and size of the communicating orifice. In addition, it facilitated placing the stent in the target lesion, reduced the time of exposure to radiation and the use of contrast medium, and provided rapid identification of intercurrent events, possibly reducing the total duration of the procedure. CONCLUSION: The use of transesophageal echocardiography during placement of aortic stents seems appropriate. The actual advantages of the procedure will be defined in a comparative prospective study.
Resumo:
OBJECTIVE - To report the results of percutaneous occlusion of persistent ductus arteriosus with the Amplatzer prosthesis in 2 Brazilian cardiological centers. METHODS - From May 1998 to July 2000, 33 patients with clinical and laboratory diagnosis of persistent ductus arteriosus underwent attempts at percutaneous implantation of the Amplatzer prosthesis. The median age was 36 months (from 6 months to 38 years), and the median weight was 14kg (from 6 to 92kg). Sixteen patients (48.5%) were under 2 years of age at the time of the procedure. All patients were followed up with periodical clinical and echocardiographic evaluations to assess the presence and degree of residual shunt and possible complications, such as pseudocoarctation of the aorta and left pulmonary artery stenosis. RESULTS - The minimum diameter of the arterial ducts ranged from 2.5 to 7.0mm (mean of 4.0±1.0, median of 3.9). The rate of success for implantation of the prosthesis was 100%. Femoral pulse was lost in 1 patient. The echocardiogram revealed total closure prior to hospital discharge in 30 patients, and in the follow-up visit 3 months later in the 3 remaining patients. The mean follow-up duration was 6.4±3.4 months. All patients were clinically well, asymptomatic, and did not need medication. No patient had narrowing of the left pulmonary artery or of the aorta. No early or late embolic events occurred, nor did infectious endarteritis. A new hospital admission was not required for any patient. CONCLUSION - The Amplatzer prosthesis for persistent ductus arteriosus is safe and highly effective for occlusion of ductus arteriosus of varied diameters, including large ones in small symptomatic infants.
Resumo:
OBJECTIVE - To describe clinical observations of marked improvement in ventricular dysfunction in a medical office environment under circumstances differing from those in study protocols and multicenter studies performed in hospital or with outpatient cohorts. METHODS - Eleven cardiac failure patients with marked ventricular dysfunction receiving treatment at a doctors office between 1994 and 1999 were studied. Their ages ranged from 20 and 66 years (mean 39.42±14.05 years); 7 patients were men, 4 were women. Cardiopathic etiologies were arterial hypertension in 5 patients, peripartum cardiomyopathy in 2, nondefined myocarditis in 2, and alcoholic cardiomyopathy in 4. Initial echocardiograms revealed left ventricular dilatation (average diastolic diameter, 69.45±8.15mm), reduced left ventricular ejection fraction (0.38±0.08) and left atrial dilatation (43.36±5.16mm). The therapeutic approach followed consisted of patient orientation, elimination of etiological or causal factors of cardiac failure, and prescription of digitalis, diuretics, and angiotensinconverting enzyme inhibitors. RESULTS - Following treatment, left ventricular ejection fraction changed to 0.63±0.09; left ventricular diameters changed to 57.18±8.13mm, and left atrium diameters changed to 37.27±8.05mm. Maximum improvement was noted after 16.9±8.63 (6 to 36) months. CONCLUSION - Patients with serious cardiac failure and ventricular dysfunction caused by hypertension, alcoholism, or myocarditis can experience marked improvement in ventricular dysfunction after undergoing appropriate therapy within the venue of the doctor's office.
Resumo:
OBJECTIVE: To evaluate the relationship between 24-hour ambulatory arterial blood pressure monitoring and the prognosis of patients with advanced congestive heart failure. METHODS: We studied 38 patients with NYHA functional class IV congestive heart failure, and analyzed left ventricular ejection fraction, diastolic diameter, and ambulatory blood pressure monitoring data. RESULTS: Twelve deaths occurred. Left ventricular ejection fraction (35.2±7.3%) and diastolic diameter (72.2±7.8mm) were not correlated with the survival. The mean 24-hour (SBP24), waking (SBPw), and sleeping (SBPs) systolic pressures of the living patients were higher than those of the deceased patients and were significant for predicting survival. Patients with mean SBP24, SBPv, and SBPs > or = 105mmHg had longer survival (p=0.002, p=0.01 and p=0.0007, respectively). Patients with diastolic blood pressure sleep decrements (dip) and patients with mean blood pressure dip <=6mmHg had longer survival (p=0.04 and p=0.01, respectively). In the multivariate analysis, SBPs was the only variable with an odds ratio of 7.61 (CI: 1.56; 3704) (p=0.01). Patients with mean SBP<105mmHg were 7.6 times more likely to die than those with SBP > or = 105 mmHg CONCLUSION: Ambulatory blood pressure monitoring appears to be a useful method for evaluating patients with congestive heart failure.
Resumo:
OBJECTIVE: To analyze the relationship between myocardial bridges and the anterior interventricular branch (anterior descending) of the left coronary artery. METHODS: The study was carried out with postmortem material, and methods of dissection and observation were used. We assessed the perimeter of the anterior interventricular branch of the left coronary artery using a pachymeter, calculated its proximal and distal diameters in relation to the myocardial bridge, and also its diameter under the myocardial bridge in 30 hearts. We also observed the position of the myocardial bridge in relation to the origin of the anterior interventricular branch. RESULTS: The diameters of the anterior interventricular branch were as follows: the mean proximal diameter was 2.76±0.76 mm; the mean diameter under the myocardial bridge was 2.08±0.54 mm; and the mean distal diameter was 1.98±0.59 mm. In 33.33% (10/30) of the cases, the diameter of the anterior interventricular branch under the myocardial bridge was lower than the diameter of the anterior interventricular branch distal to the myocardial bridge. In 3.33% (1/30) of the cases, an atherosclerotic plaque was found in the segment under the myocardial bridge. The myocardial bridge was located in the middle third of the anterior interventricular branch in 86.66% (26/30) of the cases. CONCLUSION: Myocardial bridges are more frequently found in the middle third of the anterior interventricular branch of the left coronary artery. The diameter of the anterior interventricular branch of the left coronary artery under the myocardial bridge may be smaller than after the bridge. Myocardial bridges may not provide protection against the formation of atherosclerotic plaque inside the anterior interventricular branch of the left coronary artery.
Resumo:
OBJECTIVE: Exercise training programs have been proposed as adjuncts to treatment of heart failure. The effects of a 3-month-exercise-training-program with 3 exercise sessions per week were assessed in patients with stable systolic chronic heart failure. METHODS: We studied 24 patients with final left ventricle diastolic diameter of 70±10mm and left ventricular ejection fraction of 37±4%. Mean age was 52±16 years. Twelve patients were assigned to an exercise training group (G1), and 12 patients were assigned to a control group (G2). Patients underwent treadmill testing, before and after exercise training, to assess distance walked, heart rate, systolic blood pressure, and double product. RESULTS: In G2 group, before and after 3 months, we observed, respectively distance walked, 623±553 and 561± 460m (ns); peak heart rate, 142±23 and 146± 33b/min (ns); systolic blood pressure, 154±36 and 164±26 mmHg (ns); and double product, 22211± 6454 and 24293±7373 (ns). In G1 group, before and after exercise, we observed: distance walked, 615±394 and 970± 537m (p<0.003) peak heart rate, 143±24 and 143±29b/min (ns); systolic blood pressure, 136±33 and 133±24 mmHg (ns); and double product, 19907± 7323 and 19115±5776, respectively. Comparing the groups, a significant difference existed regarding the variation in the double product, and in distance walked. CONCLUSION: Exercise training programs in patients with heart failure can bring about an improvement in physical capacity.
Resumo:
OBJECTIVE: To evaluate whether left ventricular end-systolic (ESD) diameters £ 51mm in patients (pt) with severe chronic mitral regurgitation (MR) are predictors of a poor prognosis after mitral valve surgery (MVS). METHODS: Eleven pt (aged 36±13 years) were studied in the preoperative period (pre), median of 36 days; in the early postoperative period (post1), median of 9 days; and in the late postoperative period (post2), mean of 38.5±37.6 months. Clinical and echocardiographic data were gathered from each pt with MR and systolic diameter ³51mm (mean = 57±4mm) to evaluate the result of MVS. Ten patients were in NYHA Class III/IV. RESULTS: All but 2 pt improved in functional class. Two pt died from heart failure and infectious endocarditis 14 and 11 months, respectively, after valve replacement. According to ejection fraction (EF) in post2, we identified 2 groups: group 1 (n=6), whose EF decreased in post1, but increased in post2 (p=0.01) and group 2 (n=5), whose EF decreased progressively from post1 to post2 (p=0.10). All pt with symptoms lasting £ 48 months had improvement in EF in post2 (p=0.01). CONCLUSION: ESD ³51mm are not always associated with a poor prognosis after MVS in patients with MR. Symptoms lasting up to 48 months are associated with improvement in left ventricular function.
Resumo:
OBJECTIVE: To determine the value of the radiological study of the thorax for diagnosing left ventricular dilation and left ventricular systolic dysfunction in patients with Chagas' disease. METHODS: A cross-sectional study of 166 consecutive patients with Chagas' disease and no other associated diseases. The patients underwent cardiac assessment with chest radiography and Doppler echocardiography. Sensitivity, specificity, and positive and negative predictive values of chest radiography were calculated to detect left ventricular dysfunction and the accuracy of the cardiothoracic ratio in the diagnosis of left ventricular dysfunction with the area below the ROC curve. The cardiothoracic ratio was correlated with the left ventricular ejection fraction and the left ventricular diastolic diameter. RESULTS: The abnormal chest radiogram had a sensitivity of 50%, specificity of 80.5%, and positive and negative predictive values of 51.2% and 79.8%, respectively, in the diagnosis of left ventricular dysfunction. The cardiothoracic ratio showed a weak correlation with left ventricular ejection fraction (r=-0.23) and left ventricular diastolic diameter (r=0.30). The area calculated under the ROC curve was 0.734. CONCLUSION: The radiological study of the thorax is not an accurate indicator of left ventricular dysfunction; its use as a screening method to initially approach the patient with Chagas' disease should be reevaluated.
Resumo:
OBJECTIVE:To verify the influence of moderate- or high-pressure balloon inflation during primary coronary stent implantation for acute myocardial infarction. METHODS: After successful coronary stent implantation, 82 patients were divided into 2 groups according to the last balloon inflation pressure: group 1 (³12 to <16 atm) and group 2 (³16 to 20 atm), each with 41 cases. All patients underwent late coronary angiography. RESULTS: In group 1, the mean stent deployment pressure was 13.58±0.92 atm, and in the group 2 it was 18.15±1.66 atm. Stents implanted with moderate pressures (³12 to <16 atm) had a significantly smaller postprocedural minimal lumen diameter, compared to with those with higher pressure, with lesser acute gain (2.7± 0.4 mm vs 2.9±04 mm; p=0.004), but the late lumen loss (0,9±0,8 mm vs 0,9±0,6 mm) and the restenosis (22% vs. 17.1%) and target-vessel revascularization rates (9.8% vs 7.3%) were similar between the groups. CONCLUSION: During AMI stenting, the use of high pressures (³16 atm) did not cause a measurable improvement in late outcome, either in the late loss, its index, and the net gain, or in clinical and angiographic restenosis rates.
Resumo:
OBJECTIVE: To study atheromas, Mycoplasma pneumoniae (M. pneumoniae), and Chlamydia pneumoniae (C. pneumoniae). METHODS: C. pneumoniae was studied with immunohistochemistry and M. pneumoniae with in situ hybridization (ISH), in segments of coronary arteries (SCA) as follows: group A - thrombosed ruptured plaques (TRP) of 23 patients who died due to acute myocardial infarction (AMI); group B - 23 nonruptured plaques (NRP) of group A patients; group C - NRP of 11 coronary patients who did not die due to AMI; and group D - 11 SCA from patients with dilated cardiomyopathy or Chagas' disease without atherosclerosis. RESULTS: The mean number of C. pneumoniae+ cells/400x in groups A, B, C, and D was, respectively, 3.3±3.6; 1.0±1.3; 1.2±2.4; and 0.4±0.3; and the percentage of M. pneumoniae area was, respectively, 3.9±3.5; 1.5± 1.6; 0.9±0.9; and 0.4±0.2. More M. pneumoniae and C. pneumoniae were found in of group A than in group B (P<0.01). Good correlation was seen between the area of the vessel and the M. pneumoniae area in the plaque (r = 0.46; P=0.001) and between C. pneumoniae+ cells and CD4+ T lymphocytes (r = 0.42; P<0.01). The number of C. pneumoniae+ cells correlated with CD20+ B cells (r=0.48; P<0.01). CONCLUSION: M. pneumoniae and C. pneumoniae are more frequently found in TRP correlate with the intensity of the inflammation and diameter of the vessel (positive remodeling).
Resumo:
OBJECTIVE: To evaluate the impact of the use, prior to the procedure, of injectable diltiazem to prevent complications. METHODS: Between September 2000 and July 2001, 50 patients underwent transradial coronary angiography and were randomized to receive placebo (GI) or diltiazem (GII) through a catheter inserted into the radial artery. All patients received isosorbide mononitrate. Ultrasound analyses of the radial artery were performed before examination, 30 minutes afterwards, and 7 days afterwards to evaluate the flow, the diameter, and the artery output. RESULTS: The radial artery diameter of GI was 2.4± 0.5 mm before the procedure and 2.3±0.5 mm after 30 minutes (NS), whereas in GII the diameter was 2.2±0.3 mm before the examination and 2.5±0.4 mm 30 minutes after it (P<0.001). Radial artery output in group 1 was 7.3±5.l2 mL/min before the examination and 6.1±3.5 mL/min 30 minutes after the examination (NS), and GII had an increase of 5.9±2.5 mL/min before examination to 9.05± 7.78 mL/min after the examination (P=0.04). Complications (spasm, occlusion, and partial obstruction) occurred in 4 patients (17.4%) in GI and did not occur in GII (P=0.04). CONCLUSION: The study suggests a decrease in vascular complications through the transradial access for coronary angiography with the use of diltiazem as an antispasmodic drug, resulting in the significant increase in the diameter of the radial artery and radial artery output.
Resumo:
OBJECTIVE: To assess the behavior of cardiac variables in animals exposed to cigarette smoke. METHODS: Two groups of Wistar rats were studied as follows: control group (C), comprising 28 animals; and smoking group (S), comprising 23 animals exposed to cigarette smoke for 30 days. Left ventricular cardiac function was assessed in vivo with transthoracic echocardiography, and myocardial performance was analyzed in vitro in preparations of isolated left ventricular papillary muscle. The cardiac muscle was assessed in isometric contractions with an extracellular calcium concentration of 2.5 mmol/L. RESULTS: No statistical difference was observed in the values of the body variables of the rats and in the mechanical data obtained from the papillary muscle between the control and smoking groups. The values of left ventricular systolic diameter were significantly greater in the smoking animals than in the control animals (C= 3.39 ± 0.4 mm and S= 3.71 ± 0.51 mm, P=0.02). A significant reduction was observed in systolic shortening fraction (C= 56.7 ± 4.2% and S= 53.5 ± 5.3%, P=0.02) and in ejection fraction (C= 0.92 ± 0.02 and S= 0.89 ± 0.04, P=0.01). CONCLUSION: The rats exposed to cigarette smoke had a reduction in left ventricular systolic function, although their myocardial function was preserved.
Resumo:
OBJECTIVE: To evaluate the initial clinical experience with the Helex septal occluder for percutaneous closure of atrial septal defects. METHODS: Ten patients underwent the procedure, 7 patients with ostium secundum atrial septal defects (ASD) with hemodynamic repercussions and 3 patients with pervious foramen ovale (PFO) and a history of stroke. Mean age was 33.8 years and mean weight was 55.4 kg. Mean diameter by transesophageal echocardiography and mean stretched ASD diameter were 11.33 ± 3.3mm, and 15.2 ± 3.8mm, respectively. The Qp/Qs ratio was 1.9 ± 0.3 in patients with ASD. RESULTS: Eleven occluders were placed because a patient with 2 holes needed 2 devices. It was necessary to retrieve and replace 4 devices in 3 patients. We observed immediate residual shunt (< 2mm) in 4 patients with ASD, and in those with patent foramen ovale total occlusion of the defect occurred. No complications were noted, and all patients were discharged on the following day. After 1 month, 2 patients with ASD experienced trivial residual shunts (1mm). In 1 patient, we observed mild prolapse in the proximal disk in the right atrium, without consequences. CONCLUSION: The Helex septal occluder was safe and effective for occluding small to moderate atrial septal defects. Because the implantation technique is demanding, it requires specific training of the operator. Even so, small technical failures may occur in the beginning of the learning curve, but they do not involve patient safety.
Resumo:
Background: Changes in the properties of large arteries correlate with higher cardiovascular risk. Recent guidelines have included the assessment of those properties to detect subclinical disease. Establishing reference values for the assessment methods as well as determinants of the arterial parameters and their correlations in healthy individuals is important to stratify patients. Objective: To assess, in healthy adults, the distribution of the values of pulse wave velocity, diameter, intima-media thickness and relative distensibility of the carotid artery, in addition to assessing the demographic and clinical determinants of those parameters and their correlations. Methods: This study evaluated 210 individuals (54% women; mean age, 44 ± 13 years) with no evidence of cardiovascular disease. The carotid-femoral pulse wave velocity was measured with a Complior® device. The functional and structural properties of the carotid artery were assessed by using radiofrequency ultrasound. Results: The means of the following parameters were: pulse wave velocity, 8.7 ± 1.5 m/s; diameter, 6,707.9 ± 861.6 μm; intima-media thickness, 601 ± 131 μm; relative distensibility, 5.3 ± 2.1%. No significant difference related to sex or ethnicity was observed. On multiple linear logistic regression, the factors independently related to the vascular parameters were: pulse wave velocity, to age (p < 0.01) and triglycerides (p = 0.02); intima-media thickness, to age (p < 0.01); diameter, to creatinine (p = 0.03) and age (p = 0.02); relative distensibility, to age (p < 0.01) and systolic and diastolic blood pressures (p = 0.02 and p = 0.01, respectively). Pulse wave velocity showed a positive correlation with intima media thickness (p < 0.01) and with relative distensibility (p < 0.01), while diameter showed a positive correlation with distensibility (p = 0.03). Conclusion: In healthy individuals, age was the major factor related to aortic stiffness, while age and diastolic blood pressure related to the carotid functional measure. The carotid artery structure was directly related to aortic stiffness, which was inversely related to the carotid artery functional property.
Resumo:
Background:Heart failure and atrial fibrillation (AF) often coexist in a deleterious cycle.Objective:To evaluate the clinical and echocardiographic outcomes of patients with ventricular systolic dysfunction and AF treated with radiofrequency (RF) ablation.Methods:Patients with ventricular systolic dysfunction [ejection fraction (EF) <50%] and AF refractory to drug therapy underwent stepwise RF ablation in the same session with pulmonary vein isolation, ablation of AF nests and of residual atrial tachycardia, named "background tachycardia". Clinical (NYHA functional class) and echocardiographic (EF, left atrial diameter) data were compared (McNemar test and t test) before and after ablation.Results:31 patients (6 women, 25 men), aged 37 to 77 years (mean, 59.8±10.6), underwent RF ablation. The etiology was mainly idiopathic (19 p, 61%). During a mean follow-up of 20.3±17 months, 24 patients (77%) were in sinus rhythm, 11 (35%) being on amiodarone. Eight patients (26%) underwent more than one procedure (6 underwent 2 procedures, and 2 underwent 3 procedures). Significant NYHA functional class improvement was observed (pre-ablation: 2.23±0.56; postablation: 1.13±0.35; p<0.0001). The echocardiographic outcome also showed significant ventricular function improvement (EF pre: 44.68%±6.02%, post: 59%±13.2%, p=0.0005) and a significant left atrial diameter reduction (pre: 46.61±7.3 mm; post: 43.59±6.6 mm; p=0.026). No major complications occurred.Conclusion:Our findings suggest that AF ablation in patients with ventricular systolic dysfunction is a safe and highly effective procedure. Arrhythmia control has a great impact on ventricular function recovery and functional class improvement.