93 resultados para basic solution in organic solvent


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A furan-triazole derivative has been explored as an ionophore for preparation of a highly selective Pr(III) membrane sensor. The proposed sensor exhibits a Nernstian response for Pr(III) activity over a wide concentration range with a detection limit of 5.2×10-8 M. Its response is independent of pH of the solution in the range 3.0-8.8 and offers the advantages of fast response time. To investigate the analytical applicability of the sensor, it was applied successfully as an indicator electrode in potentiometric titration of Pr(III) solution and also in the direct and indirect determination of trace Pr(III) ions in some samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blooms of cyanobacteria represent a public health risk due to their cyanotoxins such as microcystins. Liquid chromatography techniques to separate and quantify microcystins invariably use acetonitrile as the organic component of the mobile phase. The price and availability of acetonitrile together with its elevated toxicity encourage the validation of acetonitrile-free methods of microcystin analysis. In this work, methanol was employed as the organic solvent of the mobile phase and the validation method was performed with different environmental water samples. The method showed limits of detection between 0.17 and 0.25 µg/L and of quantification between 0.55 and 0.82 µg/L for the microcystin variants: -RR, -YR, -LR, -LA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work studies the influence of the film deposition process on light emission performance and on threshold voltage of OLEDs, with architecture glass/ITO/PEDOT:PSS/PVK/Alq3/Al. The commercial PVK was dissolved in different solvents such as: chloroform, tetrahydrofuran, 1,2,4-trichlorobenzene and trimethylpentane. OLEDs were characterized by current-voltage and revealed a significant influence of the solvents, although all devices emitted green electroluminescence. A difference in threshold voltage up to 10 V was observed among OLEDs prepared from different solvents. The 1,2,4-trichlorobenzene showed best performance, presenting lowest treshold voltage (≈ 6 V), followed by tetrahydrofuran (≈ 8 V), trimethylpentane (≈ 14 V) and chloroform (≈ 16 V).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a didactic experience in teaching Pearson's theory (HSAB) to graduate students in organic chemistry. This approach was based on teaching students how to use computer programs to calculate frontier orbitals (HOMO-LUMO). The suggested level of calculation was a semi-empiric PM3, proving to be efficient for obtaining robust and fast numerical results that can be performed easily in the classroom. We described a practical computational exercise and asked students to compare these numerical data with qualitative analysis using valence bond theory. A comprehensive solution of this exercise is presented, aiming to support teachers in their lessons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Materials obtained by the immobilization of 12-tungstophosphoric acid (PTA) on silica using the method of impregnation with excess solution in distinct solvents (aqueous HCl, methanol:H2O, and acetonitrile) were evaluated for use as catalysts in the methyl esterification of stearic acid. Optimum conditions were established for the impregnation of 0.5 g (w/w) of PTA on amorphous silica, under stirring at 150 rpm for 24 h, using 20 mL of 0.1 mol L-1 HCl as the solvent. After calcination at 200 ºC, high conversions were obtained under mild reaction conditions, resulting in high turnover numbers. The catalyst was evaluated in ten catalytic cycles of use, where the activity was reduced only slightly, attesting its stability and the possibility to apply it to industrial production of methylesters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

C18 chemically bonded sorbents have been the main materials used in solid phase extraction (SPE). However, due their high hydrophobicity some hydrophobic solutes are strongly retained leading to the consumption of larger quantities of organic solvent for efficient recoveries. This work presents a sorbent with lower hydrophobicity but similar selectivity to the C18 sorbent, prepared by thermal immobilization of poly(dimethylsiloxane-co-alkylmethylsiloxane) (PDAS) on silica. PDAS has organic chains with methyl groups alternating with octadecyl or hexadecyl groups in its monomeric unities. For the Si(PDAS) sorbent presented, the polymeric layer was physically adsorbed on the silica surface with 12% carbon load. Although the coating of silica with the polymeric layer was incomplete, the PDAS provided better protection for the silica surface groups, promoting mostly hydrophobic interactions between analytes and the sorbent. Sorption isotherm studies revealed that the retention of hydrophobic solutes on Si(PDAS) was less intense than on conventional sorbents, confirming the lower hydrophobicity of the lab-made sorbent. Additional advantages of Si(PDAS) include simplicity and low cost of preparation, making this material a potential sorbent for the analysis of highly hydrophobic solutes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An optode based on thymol blue (TB), an acid-based indicator, has been constructed and evaluated as a detector in FIA system for CO2 determination. The dye was chemically immobilised on the surface of a bifurcated glass optical fibre bundle, using silanisation in organic media. In FIA system, hydrogen carbonate or carbonate samples are injected in a buffer carrier solution, and then are mixed with phosphoric acid solution to generate CO2, which diffuses through a PTFE membrane, in order to be collected in an acceptor carrier fluid, pumped towards to detection cell, in which the optode was adapted. The proposed system presents two linear response ranges, from 1.0 x 10-3 to 1.0 x 10-2 mol l-1, and from 2.0 x 10-2 to 0.10 mol l-1. The sampling frequency was 11 sample h-1, with good repeatability (R.S.D < 4 %, n = 10). In flow conditions the optode lifetime was 170 h. The system was applied in the analysis of commercial mineral water and the results obtained in the hydrogen carbonate determination did not differ significantly from those obtained by potentiometry, at a confidence level of 95 %.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this research was to evaluate the effects of different irrigation depths and potassium dosages, of Jatropha seed oil content and yield. The experimental design used was randomized blocks, in split-plots, with four replicates. The treatments were four water depths (plots) and four potassium dosages (subplots) applied through irrigation water. The water depths were applied based on the percentage of accumulated evaporation of a Class A (ECA) tank and of rainfall, as following: L0 = without irrigation, L40, L80 and L120, representing 40, 80 and 120% of the balance, respectively. The potassium dosages were K30, K60, K90 and K120 (30, 60, 90 and 120kg ha-1 of potassium, respectively). The oil extraction of samples was done through chemical extraction by organic solvent. The seeds used in this test were from the sampling of two seed productions from 2009, second year of crop production. It was possible to observe that irrigation use increased oil yield and decreased the oil content of Jatropha seed. Potassium fertilization did not influence oil content and yield. There was a relative increase of efficiency in water use producing oil until certain water depth, and after that there was a decrease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT The feasibility of using sewage wastewater as a water and nutrient source for plants is an alternative to harness agricultural natural resource, observing its influence on the organic matter dynamics and soil energy. Our objective here was to evaluate the effects of applying different doses of effluent from a sewage treatment plant, in Janaúba – MG, Brazil, over the physical attributes of a soil grown with “Prata Anã” banana. From soil sample collection at depths of 0-20, 20-40, and 40-60 cm, we determined the following soil properties: soil density, total porosity, macroporosity, microporosity, organic matter, clay dispersed in water and stability of soil aggregate. The experimental design was in randomized blocks with four repetitions. Wastewater raising doses promoted increase in suspended solids, contributing to macroporosity reduction at 20-40 and 40-60 cm depths; as well as a reduction in organic matter within 0-20 cm layer. Clay dispersal was observed in the depths of 0-20 cm, being derived from an increase in sodium content. Concurrently, there was a reduction of soil aggregate stability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple factors can be involved in the virulence processes of Aeromonas hydrophila. The objective of the present paper was to verify the presence of aerolysin, hidrolipase, elastase and lipase virulence genes through the polymerase chain reaction (PCR) in A. hydrophila isolates obtained from fish of the São Francisco River Valley, and to evaluate virulence according to the presence of these genes in Nile tilapia fingerlings. One hundred and fourteen isolates from the bacteria were used. DNA was heat extracted and PCR undertaken using specific primers described in the literature. For in vivo tests Nile tilapia fingerlings were used. From the PCR tests, negative isolates for all genes tested were selected, positive isolates for two genes (aerolysin and elastase) and positive for the four genes tested. These were inoculated at a concentration of 10(8) UFC/ml into the tilapias, considered as treatments; another group of animals was used as control (with inoculation of saline solution). In all, 12 distinct standards regarding the presence of virulence factors in isolates from A. hydrophila, were observed. Of the 114 isolates analyzed, 100 (87.72%) presented at least one of the virulence factors under study. The virulence factors were widely distributed among the A. hydrophila isolates. Aerolysin was the most frequent virulence factor present in the isolates analyzed. A. hydrophila led to the mortality of the Nile tilapia fingerlings, regardless of the absence or quantity of virulence genes tested.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes a lumped parameter mathematical model for the prediction of transients in an aerodynamic circuit of a transonic wind tunnel. Control actions to properly handle those perturbations are also assessed. The tunnel circuit technology is up to date and incorporates a novel feature: high-enthalpy air injection to extend the tunnel’s Reynolds number capability. The model solves the equations of continuity, energy and momentum and defines density, internal energy and mass flow as the basic parameters in the aerodynamic study as well as Mach number, stagnation pressure and stagnation temperature, all referred to test section conditions, as the main control variables. The tunnel circuit response to control actions and the stability of the flow are numerically investigated. Initially, for validation purposes, the code was applied to the AWT ("Altitude Wind Tunnel" of NASA-Lewis). In the sequel, the Brazilian transonic wind tunnel was investigated, with all the main control systems modeled, including injection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work studies the forced convection problem in internal flow between concentric annular ducts, with radial fins at the internal tube surface. The finned surface heat transfer is analyzed by two different approaches. In the first one, it is assumed one-dimensional heat conduction along the internal tube wall and fins, with the convection heat transfer coefficient being a known parameter, determined by an uncoupled solution. In the other way, named conjugated approach, the mathematical model (continuity, momentum, energy and K-epsilon equations) applied to tube annuli problem was numerically solved using finite element technique in a coupled formulation. At first time, a comparison was made between results obtained for the conjugated problem and experimental data, showing good agreement. Then, the temperature profiles under these two approaches were compared to each other to analyze the validity of the one-dimensional classical formulation that has been utilized in the heat exchanger design.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT The objective of this study was to evaluate the availability of herbicides clomazone and tebuthiuron in the solution in different kinds of soils saturated with water or vinasse. Samples of 30 soils with different characteristics were arranged on trays to the herbicides spraying. Then they were homogenized, placed in plastic cartridges and saturated with deionized water or vinasse, and remaining at rest during 18 hours. Two extractions were made, the first one quantified the presence of the herbicides in the soil solution and in the second one the total extraction of herbicide remaining in the soil was taken to determine the recovery percentage of each herbicide tested. For quantification, a LC-MS/MS system was used, a compound of a high performance liquid chromatograph (HPLC) coupled to a triple quadruple mass spectrometer. Tebuthiuron was more available in the soil with the vinasse addition when compared to water. Vinasse applications resulted in no significant difference in availability of clomazone between treatments. Tebuthiuron showed the highest availability frequencies, and on average of all samples 32.49% were extracted from total herbicide applied, while for clomazone this value was 16.50%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The possibility of producing neutralizing antibodies against the lethal effects of scorpion toxins was evaluated in the mouse model by immunization with an immunogen devoid of toxicity. A toxic fraction (5 mg) from the venom of the scorpion Tityus serrulatus was entrapped in sphingomyelin-cholesterol liposomes. The liposomes were treated for 1 h at 37oC with a 1% (w/w) trypsin solution in 0.2 M sodium carbonate buffer, pH 8.3. This treatment led to a strong reduction in venom toxicity. Immunization was performed as follows: mice were injected sc with 20 µg of the liposome-entrapped toxic fraction on days 1 and 21 and a final injection (20 µg) was administered ip on day 36. After injection of the immunogen, all mice developed an IgG response which was shown to be specific for the toxic antigen. The antibodies were measured 10 days after the end of the immunization protocol. In an in vitro neutralization assay we observed that pre-incubation of a lethal dose of the toxic fraction with immune serum strongly reduced its toxicity. In vivo protection assays showed that mice with anti-toxin antibodies could resist the challenge with the toxic fraction, which killed, 30 min after injection, all non-immune control mice

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have observed that acute blood volume expansion increases the gastroduodenal resistance to the flow of liquid in anesthetized dogs, while retraction decreases it (Santos et al. (1991) Acta Physiologica Scandinavica, 143: 261-269). This study evaluates the effect of blood volume expansion and retraction on the gastric emptying of liquid in awake rats using a modification of the technique of Scarpignato (1980) (Archives Internationales de Pharmacodynamie et de Therapie, 246: 286-294). Male Wistar rats (180-200 g) were fasted for 16 h with water ad libitum and 1.5 ml of the test meal (0.5 mg/ml phenol red solution in 5% glucose) was delivered to the stomach immediately after random submission to one of the following protocols: 1) normovolemic control (N = 22), 2) expansion (N = 72) by intravenous infusion (1 ml/min) of Ringer-bicarbonate solution, volumes of 1, 2, 3 or 5% body weight, or 3) retraction (N = 22) by controlled bleeding (1.5 ml/100 g). Gastric emptying of liquid was inhibited by 19-51.2% (P<0.05) after blood volume expansion (volumes of 1, 2, 3 or 5% body weight). Blood volume expansion produced a sustained increase in central venous pressure while mean arterial pressure was transiently increased during expansion (P<0.05). Blood volume retraction increased gastric emptying by 28.5-49.9% (P<0.05) and decreased central venous pressure and mean arterial pressure (P<0.05). Infusion of the shed blood 10 min after bleeding reversed the effect of retraction on gastric emptying. These findings suggest that gastric emptying of liquid is subject to modulation by the blood volume.