121 resultados para anionic contaminants
Resumo:
The present work aimed modify chemically the chitosan (QTS) surface to obtain a reticulate chitosan quaternary ammonium salt (SAQQR), and compare this anionic exchanger with an commercial ion exchanger in the extraction of available phosphorus in soils. The results showed that the two exchangers are identical, extracting similar and proportional quantities of available phosphorus in the studied soils, and the anionic exchanger of SAQQR provides a high chemical stability, not affected by the pH difference of soils.
Efecto del catión, del anión y del co-ión sobre la agregación de líquidos iónicos en solución acuosa
Resumo:
The aggregation behavior of thirteen 1-alkyl-3-methylimidazolium based ionic liquids in aqueous solution is presented, considering variations of the alkyl side chain length as well as the anionic moiety. Cation and anion molecular volumes are selected as appropriate molecular descriptors. Additionally, the existing relationship between critical micelle concentration (CMC) and electrolyte concentration in solution is established, aiming to clarify ion effects. CMC values were obtained by measuring electrical conductivity and surface tension. It was confirmed that aggregation of ionic liquids in aqueous solution and in presence of inorganic salts is affected by the factors developed in this study.
Resumo:
An UV-Ozone reactor was developed with an ignition tube extracted into HID mercury lamp used to irradiation on zinc oxide (ZnO) and fluorinated tin oxide (FTO) films for PLEDs devices. Different exposures times were used. In contact angle measurements revealed better results for ZnO and FTO by 15 and 5 min, respectively. In Diffuse Reflectance Infra-red Fourier Transformed (DRIFT) spectroscopy allowed the observation of water, hydrocarbon and carbon dioxide adsorbed on the untreated TCO surfaces. After the UV-Ozone treatment the contaminants were significantly reduced or eliminated and the PLEDs devices decreased threshold voltages in comparison with respectively untreated TCOs.
Resumo:
An analytical procedure for determination of estriol, 17β-estradiol, estrone and 17α-ethinylestradiol in drinking water is presented. The method employs solid phase extraction (SPE) and sample dechlorination as cleanup procedures, followed by HPLC-DAD analysis. Validation was carried out using RE No. 899/2003 guidelines established by the Agência Nacional de Vigilância Sanitária (National Agency of Sanitary Surveillance, Brazil), with some adaptations. The statistically evaluated results have shown that the method is selective, precise (0,06% to 19,40% CV) and accurate (91,52% to 109,41% average recoveries). The developed method was applied to the analysis of these contaminants in drinking water from São Luís, MA.
Resumo:
The objective of the present study was the evaluation of the presence of organic and inorganic contaminants in samples of aged cachaça from the South of the state of Minas Gerais. Furfural, methanol and copper were determined by colorimetric reactions, while the analyses of ethyl carbamate and acrolein were performed by GC/MS and HPLC, respectively. High levels of furfural and copper were obtained. All samples showed concentrations below the established by legislation for the ethyl carbamate, and for acrolein, only one sample showed higher levels. Methanol was not detected in the samples.
Resumo:
Clay is often employed as a catalyst, but quartz impurities can decrease the catalytic efficiency. Fine particles of clay can be purified by flotation. We examined the cationic surfactant hexadecyltrimethylammonium bromide (HTAB), the anionic sodium dodecyl sulfate (SDS) and the non-ionic TRITON X-100 for separating the quartz impurities from clay. Using X-ray diffraction, the separation was monitored for changes in the peaks corresponding to clay and quartz. Cationic surfactant HTAB was most effective in separating the quartz-clay mixture and the selectivity can be explained by internal adsorption of the surfactant onto the clay and external adsorption onto the quartz.
Resumo:
Emerging organic pollutants (EOP) include many environmental contaminants based on commercial products such as pharmaceuticals, personal care products, detergents, gasoline, polymers, etc. EOP may be candidates for future regulation as they offer potential risk to environmental and human health due to their continual entrance into the environment and to the fact that even the most modern wastewater treatment plants are not able to totally transform / remove these compounds. High performance liquid chromatography is recommended to separate emerging organic pollutants with characteristics of high polarity and low volatility, especially pharmaceuticals, from environmental matrices.
Resumo:
In this work, the interactions between the non-ionic polymer of ethyl(hydroxyethyl)cellulose (EHEC) and mixed anionic surfactant sodium dodecanoate (SDoD)-sodium decanoate (SDeC) in aqueous media, at pH 9.2 (20 mM borate/NaOH buffer) were investigated by electric conductivity and light transmittance measurements at 25 ºC. The parameters of the surfactant to polymer association processes such as the critical aggregation concentration and saturation of the polymer by surfactants were determined from plots of specific conductivity vs total surfactant concentration, [surfactant]tot = [SDoD] + [SDeC]. Through the results was not observed a specific link of polymer with the surfactant, implying therefore a phenomenon only cooperative association.
Resumo:
The wastewaters from biodiesel production contain as primarily wastes sodium or potassium soaps, fatty acids, glycerin, alcohol and other contaminants. In general, these waters are chemically unsuitable for release to any water body, so, it is necessary the adoption of techniques for the treatment of this effluent. In this review, electrochemical, biological, physicochemical, and combined treatments reported for the removal of the wastewater containing pollutants come from biodiesel production have been summarized. In addition, the recovery, the reuse, the energy production and the synthesis of new compounds from the organic matter contained in this kind of effluent are also reviewed.
Resumo:
An optical chemical sensor for the determination of nitrite based on incorporating methyltrioctylammonium chloride as an anionic exchanger on the triacetylcellulose polymer has been reported. The response of the sensor is based on the redox reaction between nitrite in aqueous solution and iodide adsorbed on sensing membrane using anion exchange phenomena. The sensing membrane reversibly responses to nitrite ion over the range of 6.52×10-6 - 8.70×10-5 mol L-1 with a detection limit of 6.05×10-7 mol L-1 (0.03 µg mL-1) and response time of 6 min. The relative standard deviation for eight replicate measurements of 8.70×10-6 and 4.34×10-5 mol L-1 of nitrite was 4.4 and 2.5 %, respectively. The sensor was successfully applied for determination of nitrite in food, saliva and water samples.
Resumo:
Although metals and nitrogen/sulfur compounds have been the main concern of the petroleum industry, issues concerning the harmful effects on catalysts poisoning and product contamination by other contaminants such as oxygen-containing compounds have been raised. Trace amounts of carbonyl and carboxyl compounds in petroleum products can lead to catalyst poisoning. Additionally, oxygenates may be present in final polyethylene and polypropylene resins, affecting the quality of food packaging. In this work, we reviewed potential analytical approaches for oxygenates determination in petroleum products and report the features of each potential technique.
Stability-indicating comparative methods using mekc and lc for determination of olmesartan medoxomil
Resumo:
A stability-indicating method using MEKC was validated for the analysis of olmesartan medoxomil in tablets. Successful separation was achieved using a fused silica capillary (40 cm x 50 µm i.d.); background electrolyte consisted of a combination of 10 mmol L-1 borate buffer and 5 mmol L-1 anionic detergent sodium dodecyl sulfate (95:5; v/v) pH 6.5; hydrodynamic mode at 50 mBar for 5 s; 25 kV separation voltage at 25 ºC; and column temperature 25 ºC with detection at 257 nm. The proposed method, validated following ICH guidelines, was applied to the determination of this antihypertensive with good results compared with an LC method.
Resumo:
Hydrogen peroxide has been used for decades in developed countries as an oxidizing agent in the treatment of water, domestic sewage and industrial effluents. This study evaluated the influence of the concentration of H2O2 and pH on the inactivation of Escherichia coli cells and the disinfection of sewage treated. The results showed that the inactivation rate increased with pH and H2O2. The presence of other contaminants dissolved in the effluent is probably the cause of these differences, because E. coli inactivation in synthetic wastewater was found to be much faster than in the real treated domestic sewage.
Resumo:
Drugs of abuse are commonly used outside medical or legal settings where their production, marketing and consumption are subject to legal summons and/or intervention. Classified as emerging contaminants, these substances have been recently detected in samples of environmental concern, such as waters and wastewaters. This review presents the state-of-the-art on the methodological approaches used in sample preparation, the main techniques applied in analytical determination at trace levels, as well as the use of information related to the drug or its metabolite concentration in sewage samples to empirically estimate the consumption of drugs of abuse in a city or region.
Resumo:
This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.