331 resultados para Yersinia pestis F1 antigen detection


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present study was conducted to evaluate the frequency of antigenic components recognized by serum IgG antibodies in Western blotting (WB) using a Strongyloides ratti larval extract for the diagnosis of human strongyloidiasis. In addition, the WB results were compared to the enzyme-linked immunosorbent assay (ELISA) and the indirect immunofluorescence antibody test (IFAT) results. Serum samples of 180 individuals were analyzed (80 with strongyloidiasis, 60 with other intestinal parasitoses, and 40 healthy individuals). S. ratti was obtained from fecal culture of experimentally infected Rattus rattus. For IFAT, S. ratti larvae were used as antigen and S. ratti larval antigenic extracts were employed in WB and ELISA. Eleven S. ratti antigenic components were predominantly recognized by IgG antibodies in sera of patients with strongyloidiasis. There was a positive concordance for the three tests in 87.5% of the cases of strongyloidiasis. The negative concordance in the three tests was 94% and 97.5%, in patients with other intestinal parasitoses and healthy individuals, respectively. In cases of positive ELISA and negative IFAT results, diagnosis could be confirmed by WB. ELISA, IFAT, and WB using S. ratti antigens showed a high rate of sensitivity and specificity. In conclusion, WB using S. ratti larval extract was able to recognize 11 immunodominant antigenic components, showing to be a useful tool to define the diagnosis in cases of equivocal serology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Significant advances were made in the diagnosis of filariasis in the 1990s with the emergence of three new alternative tools: ultrasound and tests to detect circulating antigen using two monoclonal antibodies, Og4C3 and AD12-ICT-card. This study aimed to identify which of these methods is the most sensitive for diagnosis of infection. A total of 256 individuals, all male and carrying microfilariae (1-15,679 MF/mL), diagnosed by nocturnal venous blood samples, were tested by all three techniques. The tests for circulating filarial antigen concurred 100% and correctly identified 246/256 (96.69%) of the positive individuals, while ultrasound detected only 186/256 (73.44%). Of the circulating antigen tests, ICT-card was the most convenient method for identification of Wuchereria bancrofti carriers. It was easy to perform, practical and quick.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Feline Immunodeficiency Virus is a worldwide infection and is considered a significant pathogen. The diagnosis of FIV infections is mainly based on commercially available rapid tests that are highly expensive in Brazil, hence it is rarely performed in the country. Furthermore, lentiviruses grow slowly and poorly in tissue cultures, making the production of viral antigen by classic means and thus the establishment of FIV immunodiagnosis impracticable. In order to deal with this, recombinant DNA techniques were adopted to produce the protein p24, a viral capsid antigen. The protein's reactivity evaluation analyzed by Western blot indicated that this recombinant antigen can be a useful tool for the immunodiagnostic of FIV infections.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Babesiosis is one of the most important diseases affecting livestock agriculture worldwide. Animals from the subspecies Bos taurus indicus are more resistant to babesiosis than those from Bos taurus taurus. The genera Babesia and Plasmodium are Apicomplexa hemoparasites and share features such as invasion of red blood cells (RBC). The glycoprotein Duffy is the only human erythrocyte receptor for Pasmodium vivax and a mutation which abolishes expression of this glycoprotein on erythrocyte surfaces is responsible for making the majority of people originating from the indigenous populations of West Africa resistant to P. vivax. The current work detected and quantified the Duffy antigen on Bos taurus indicus and Bos taurus taurus erythrocyte surfaces using a polyclonal antibody in order to investigate if differences in susceptibility to Babesia are due to different levels of Duffy antigen expression on the RBCs of these animals, as is known to be the case in human beings for interactions of Plasmodium vivax-Duffy antigen. ELISA tests showed that the antibody that was raised against Duffy antigens detected the presence of Duffy antigen in both subspecies and that the amount of this antigen on those erythrocyte membranes was similar. These results indicate that the greater resistance of B. taurus indicus to babesiosis cannot be explained by the absence or lower expression of Duffy antigen on RBC surfaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the main difficulties related to the detection of the Hepatitis Delta Virus (HDV) antigen and antibody has been the source of the needed HD antigen since HDV containing human and animal livers are very difficult to obtain and since yield is low. This fact prompted us to try to use the serum of patients in the acute phase of HDV infection as a source of HDAg and turn to enzyme immunoassays (EIA) instead of RIA for the sake of easiness and economy in the amount of HDAg needed. The antigen for EIA was obtained from patients during the acute phase of HDV infection and the antibody from patients who have been carriers for many years. For the detection of the antigen, a sandwich type method was employed, whereas for the antibody a competition assay was developed. In order to assess the relative specificity and sensibility of the test, the antibody assay was compared to a commercial RIA (C. RIA, Abbott) and to a non-commercial RIA (NC RIA). Forty-two sera were tested by the two methods and only in two cases discrepant results were obtained. Its is concluded that: 1) sera from patients in the acute and chronic phases of HDV infection can be used as source of both antigen and antibody, for immunoassays; 2) EIA and RIA have comparable relative specificity and sensibility and 3) EIA is easier to perform, cheaper, non-hazardous, has a longer shelf-life and saves scarce HDAg.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A passive haemagglutination test (PHA) for human neurocysticercosis was standardized and evaluated for the detection of specific antibodies to Cysticercus cellulosae in cerebrospinal fluid (CSF). For the assay, formaldehyde-treated group O Rh-human red cells coated with the cysticerci crude total saline extract (TS) antigen were employed. A total of 115 CSF samples from patients with neurocysticercosis was analysed, of these 94 presented reactivity, corresponding to 81.7% sensitivity, in which confidence limit of 95% probability (CL95%) ranged from 74.5% to 88.9%. Eighty-nine CSF samples derived from individuals of control group presented as nonreactive in 94.4% (CL95% from 89.6% to 99.2%). The positive and negative predictive values were 1.4% and 99.9%, respectively, considering the mean rate of that this assay provide a rapid, highly reproducible, and moderately sensitive mean of detecting specific antibodies in CSF samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A comparison of two different standardized reagent procedures for the passive haemagglutination test (PHA) in the detection of specific antibody to Cysticercus cellulosae in cerebrospinal fluid (CSF) was carried out. The formaldehyde-treated group O Rh-human red blood cells (HuRBC) and glutaraldehyde-treated sheep red blood cells (SRBC) were the supplies for the reagents preparation and, in the tests, they were designated as PHA-1 and PHA-2, respectively. For both reagents the cells were coated with the cysticerci total saline extract (TS) antigen. PHA-1 and PHA-2 were assessed in a total of 204 CSF from patients with neurocysticercosis, from non-related infections and from healthy individuals. The positivity and specificity indices obtained were respectively 81.7% and 94.4% for PHA-1 and for PHA-2, 88.7% and 96.6%. Since no significant differences were observed between the results provided by two reagents, at level of significance of 0.05, either processes of cell sensitization can alternatively be used according to the own laboratory convenience.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sera from 299 fishermen 16 to 80 years old, residents in Cananeia and Iguape counties, southern cost of São Paulo State, Brazil, were studied in order to identify a possible association between the prevalence of specific antibodies to the hepatitis B virus (HBV) and exposure to haematophagus mosquitoes evaluated by the prevalence of arbovirus antibodies. This professional group presented the highest prevalence of arbovirus antibodies (54.1%) in past investigations carried out in this heavily forested region. Detection of antibody to hepatitis B core antigen (anti-HBc) in the sera was done by enzyme immunoassay (Roche). Prevalence of anti-HBc antibodies in this group was 31.4% (94/299) which is very high compared with 7.2% to 15.0% for different groups of healthy adults in State of São Paulo. No significant difference is observed between the prevalences of HBV antibodies in Iguape and Cananeia. Prevalence of anti-HBc and anti-arbovirus antibodies increases with age. There is a concordance in the distribution according to age groups of the frequency of anti-HBc and anti-arbovirus positive sera. Ag HBs was detected in 4% of the studied sera. These results support the hypothesis that the transmission of the hepatitis B virus and the arboviruses may be due to the same factor, one of the possibilities would be by anthropophilic mosquitoes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A dot enzyme-linked immunosorbent assay (DOT-ELISA) was developed to detect specific antibodies in cerebrospinal fluid (CSF) for human neurocysticercosis immunodiagnosis, with Cysticercus cellulosae antigen dotted on a new solid-phase. This was represented by sheets of a synthetic polyester fabric impregnated with a polymerized resin (N-methylol-acrylamide). A very stable preparation was thus obtained, the antigen being covalently bound by cross-linking with free N-methylol groups on the resin. Since robust, no special care was necessary for handling the solid-phase. The test could be performed at room-temperature. From 30 CSF samples assayed, 14 were positive, from a group of 15 cases of neurocysticercosis, with titers from 1 to 128; 15 other samples, from normals or other neurological diseases, were all negative. Test characteristics seem to indicate it as adequate for epidemiological surveys. A more detailed study on sensitivity, specificity, reproducibility and the use in serum samples is being conducted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two groups of patients undergoing hemodialysis (HD) maintenance were evaluated for their antibody response to non-structural c100/3 protein and structural core protein of hepatitis C virus (HCV). Forty-six patients (Group 1) never presented liver abnormalities during HD treatment, while 52 patients (Group 2) had either current or prior liver enzyme elevations. Prevalence rates of 32.6% and 41.3% were found for anti-c100/3 and anti-HCV core antibodies, respectively, in patients with silent infections (Group 1). The rate of anti-c100/3 in patients of Group 2 was 71.15% and reached 86.5% for anti-HCV core antibodies. The recognition of anti-c100/3 and anti-core antibodies was significantly higher in Group 2 than in Group 1. A line immunoassay composed of structural and non-structural peptides was used as a confirmation assay. HBV infection, measured by the presence of anti-HBc antibodies, was observed in 39.8% of the patients. Six were HBsAg chronic carriers and 13 had naturally acquired anti-HBs antibodies. The duration of HD treatment was correlated with anti-HCV positivity. A high prevalence of 96.7% (Group 2) was found in patients who underwent more than 5 years of treatment. Our results suggest that anti-HCV core ELISA is more accurate for detecting HCV infection than anti-c100/3. Although the risk associated with the duration of HD treatment and blood transfusion was high, additional factors such as a significant non-transfusional spread of HCV seems to play a role as well. The identification of infective patients by more sensitive methods for HCV genome detection should help to control the transmission of HCV in the unit under study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study evaluated six Plasmodium falciparum antigen extracts to be used in the IgG and IgM enzyme-linked immunosorbent assays (ELISA), for malaria diagnosis and epidemiological studies. Results obtained with eighteen positive and nine negative control sera indicated that there were statistically significant differences among these antigen extracts (Multifactor ANOVA, p< 0.0001). Urea, sodium deoxycholate and Zwittergent antigen extracts performed better than did the three others, their features being very similar for the detection of IgG antibodies. Urea, alkaline and sodium deoxycholate antigen extracts proved to be better than the others for the detection of IgM antibodies. A straight line relationship was found between the optical densities (or their respective log 10) and the log 10 of antibody dilutions, with a very constant slope. Thus serum titers could be determined by direct titration and by two different equations, needing only one serum dilution. For IgM antibody detections, log 10 expression gave results that better correlated with direct titration (95% Bonferroni). For IgG antibody detections, the titer differences were not significant. The reproducibility of antibody titers and antigen batches was also evaluated, giving satisfactory results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Toxoplasmic encephalitis (TE) is a mayor cause of central nervous system infection in patients with acquired immunodeficiency syndrome (AIDS). Toxoplasma antibodies were detected in 56 of 79 patients with AIDS (71%), in the present study. Fourteen out of 57 seropositive patients developed TF (25%) and had Toxoplasma gondii antigen detected in their urine. For this, most of them received an effective therapy, with the subsequent disappearance of the symptoms and discontinuity of excretion of the T. gondii antigens. Our results suggest that the monitoring of T. gondii antigen in the urine of AIDS patients may be useful to decide on the proper time for therapy, as well as to avoid the beginning of neurologic signs in these patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Human schistosomiasis, caused by Schistosoma mansoni, is highly prevalent in Brazil and usually diagnosed by time consuming stool analysis. Serological tests are of limited use in this disease, mainly for epidemiological studies, showing no discrimination between previous contact with the parasite and active infections. In the present study, we standardized and compared a Dot-ELISA for IgM and IgG antibodies against S. mansoni antigens from eggs and worms with a routine IgG and IgM immunofluorescence assay using similar antigens, in the study of sera from 27 patients who had quantified egg stool excretion. The positivity obtained for IgG Dot-ELISA was 96.3% and 88.9% for IgM Dot-ELISA with worm antigen and 92.6% and 90.9% with egg antigen. The IFI presented similar positivities using worm antigen, 92.6% (IgG) and 96.3% (IgM),and lower results with egg antigen, 77.8% (IgG and IgM). The patients studied were divided into two groups according to their egg excretion, with greater positivity of serological tests in higher egg excreters. When comparing the quantitative egg excretion and the serological titers of the patients, we detected a correlation only with IgM Dot-ELISA, with r=0.552 (p=0.0127). These data show that Dot-ELISA can be used for the detection of specific antibodies against S. mansoni in sera from suspected patients or in epidemiological studies and, with further purification of egg antigen and larger samples, IgM Dot-ELISA could be a possible tool for rough estimates of parasite burden in epidemiological studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Amebiasis continues to be of epidemiological importance in underdeveloped countries. Clinical diagnosis and epidemiological setting in a region are based on the fecal microscopic identification of cysts or trophozoites. This procedure requires well trained personnel, is laborious, of low sensitivity and frequently yields false-positives results. The present study was designed to develop an immuno-enzymatic fecal 96 kDa antigen capture test (COPROELISA-Eh) more sensitive and specific than microscopic diagnosis of amebiasis. Triplicates of 177 stool samples processed by the formol-ether concentration method, were defined as positive or negative by three experienced microscopic observers. Another aliquot was submitted to the antigen capture test by a monoclonal antibody against a specific membrane antigen of pathogenic strains of Entamoeba histolytica. Optical densities were interpreted as positive when they exceeded the mean value of negative samples plus two standard deviations. COPROELISA-Eh showed a 94.4% sensitivity, 98.3% specificity, 96.2% positive predictive value and 97.6% negative predictive value for the detection of E. histolytica in feces. COPROELISA-Eh is more sensitive and specific than microscopic examination, does not require specially trained personnel and allows the simultaneous processing of a large number of samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ORF strain of Cysticercus longicollis represents an important model for the study of heterologous antigens in the immunodiagnosis of neurocysticercosis (NC). The immunoperoxidase (IP) technique was standardized using a particulate antigen suspension of Cysticercus longicollis (Cl) and Cysticercus cellulosae (Cc). Cerebrospinal fluid (CSF) samples were incubated on the antigen fixed to microscopy slides; the conjugate employed was anti-IgG-peroxidase and the enzymatic reaction was started by covering the slides with chromogen solution (diaminobenzidine/H2O2). After washing with distilled water, the slide was stained with 2% malachite green in water. Of the CSF samples from 21 patients with NC, 19 (90.5%) were positive, whereas the 8 CSF samples from the control group (100%) were negative. The results of the IP-Cl test applied to 127 CSF samples from patients with suspected NC showed 28.3% reactivity as opposed to 29.1 % for the IP-Cc test. The agreement index for the IP test (Cl x Cc) was 94.2%, with no significant difference between the two antigens.