90 resultados para Standard Penetration Test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The RID assay is one of the in vitro methods used for in-process control in the production of rabies vaccines for veterinary use. It has been shown to be very useful for determining antigen concentration in the final bulk product. The work presented in this paper, including the production and standardization of candidate standard reagents for use in the Radial Immunodiffusion Assay (RID) was carried out at the Pan American Institute for Food Protection and Zoonoses (INPPAZ/PAHO/WHO). The study was completed with the cooperation of the Faculty of Veterinary Sciences, National University of La Plata (NULP), Argentina, where the validation of the proposed standards and the quality control of samples from 28 different batches of rabies vaccines produced with Pasteur strain rabies virus (PV) in BHK cells were performed. The activity of the vaccines was determined by in vivo (NIH) and in vitro (RID)assays. The results of the candidate reagents for the reagent standardization tests showed stability, sensitivity and reproducibility. The Relative Potency the 1.2 between the problem vaccines and the reference vaccine was estimated by variance and regression analysis. The results of our validation study show that the INPPAZ (PAHO/WHO) is capable of producing and distributing the above-mentioned standard reagents, as well as of providing support for the incorporation of the RID technique (sensitive, rapid and inexpensive) to the laboratories that manufacture rabies vaccines in Latin America and the Caribbean.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An epizootic outbreak of rabies occurred in 1995 in Ribeirão Preto, SP, with 58 cases of animal rabies (54 dogs, 3 cats and 1 bat) confirmed by the Pasteur Institute of São Paulo, and one human death. The need to provide care to a large number of people for the application of equine rabies immune globulin (ERIG) prevented the execution of the skin sensitivity test (SST) and often also the execution of desensitization, procedures routinely used up to that time at the Emergency Unit of the University Hospital of the Faculty of Medicine of Ribeirão Preto, University of São Paulo (EU-UHFMRP-USP), a reference hospital for the application of heterologous sera. In view of our positive experience of several years with the abolition of SST and of the use of premedication before the application of antivenom sera, we used a similar schedule for ERIG application. Of the 1489 victims of animal bites, 1054 (71%) received ERIG; no patient was submitted to SST and all received intravenously anti-histamines (anti-H1 + anti-H2) and corticosteroids before the procedure. The patients were kept under observation for 60 to 180 minutes and no adverse reaction was observed. On the basis of these results, since December 1995 ERIG application has been decentralized in Ribeirão Preto and has become the responsibility of the Emergency Unit of the University Hospital and the Central Basic Health Unit, where the same routine is used. Since then, 4216 patients have received ERIG (1818 at the Basic Health Unit and 2398 at the EU-UHFMRP), with no problems. The ideal would be the routine use of human rabies immune globulin (HRIG) in public health programs, but this is problematic, because of their high cost. However, while this does not occur, the use of SST is no longer justified at the time of application of ERIG, in view of the clinical evidence of low predictive value and low sensitivity of SST involving the application of heterologous sera. It is very important to point out that a negative SST result may lead the health team to a feeling of false safety that no adverse reaction will occur, but this is not true for the anaphylactoid reactions. The decision to use premedication, which is based on knowledge about anaphylaxis and on the pharmacology of the medication used, is left to the judgment of health professionals, who should always be prepared for eventual untoward events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In occupational accidents involving health professionals handling potentially contaminated material, the decision to start or to continue prophylactic medication against infection by Human Immunodeficiency Virus (HIV) has been based on the ELISA test applied to a blood sample from the source patient. In order to rationalize the prophylactic use of antiretroviral agents, a rapid serologic diagnostic test of HIV infection was tested by the enzymatic immunoabsorption method (SUDS HIV 1+2, MUREX®) and compared to conventional ELISA (Abbott HIV-1/ HIV-2 3rd Generation plus EIA®). A total of 592 cases of occupational accidents were recorded at the University Hospital of Ribeirão Preto from July 1998 to April 1999. Of these, 109 were simultaneously evaluated by the rapid test and by ELISA HIV. The rapid test was positive in three cases and was confirmed by ELISA and in one the result was inconclusive and later found to be negative by ELISA. In the 106 accidents in which the rapid test was negative no prophylactic medication was instituted, with an estimated reduction in costs of US$ 2,889.35. In addition to this advantage, the good correlation of the rapid test with ELISA, the shorter duration of stress and the absence of exposure of the health worker to the adverse effects of antiretroviral agents suggest the adoption of this test in Programs of Attention to Accidents with Potentially Contaminated Material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple and rapid latex-based diagnostic tests have been used for detecting specific antigens or antibodies in several diseases. In this article, we present the preliminary results obtained with a latex agglutination test (LAT) for diagnosing neurocysticercosis by detection of antibodies in CSF. A total of 43 CSF samples were assayed by the LAT: 19 CSF samples from patients with neurocysticercosis and 24 CSF samples from patients with other neurologic disorders (neurosyphilis, n = 8; neurotoxoplasmosis, n = 3; viral meningitis, n = 4, chronic headache, n = 9). The LAT exhibited 89.5% sensitivity and 75% specificity. The use of LAT seems to be an additional approach for the screening of neurocysticercosis with advantage of simplicity and rapidity. Further studies could be performed using purified antigens and serum samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid test based on an immunochromatography assay - Determine™ Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine™ test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine™ is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a cheaper an simple in house indirect ELISA that uses the live attenuated VZV vaccine as a coating antigen. The alternative ELISA had an agreement of 94% when compared with a commercial VZV ELISA kit. Moreover, our ELISA proved to be more reliable than the kit when assessing true negative samples. By adding a standard serum, we were able to produce results in international units per millilitre. Also, the addition of an extra step with 8M urea allowed the assessment of VZV IgG avidity without excessive costs. The cost per sample to test VZV IgG was 2.7 times cheaper with our ELISA, allowing the testing of many samples without the burden of production of VZV antigen in the laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pathogenesis of the renal lesion upon envenomation by snakebite has been related to myolysis, hemolysis, hypotension and/or direct venom nephrotoxicity caused by the venom. Both primary and continuous cell culture systems provide an in vitro alternative for quantitative evaluation of the toxicity of snake venoms. Crude Crotalus vegrandis venom was fractionated by molecular exclusion chromatography. The toxicity of C. vegrandis crude venom, hemorrhagic, and neurotoxic fractions were evaluated on mouse primary renal cells and a continuous cell line of Vero cells maintained in vitro. Cells were isolated from murine renal cortex and were grown in 96 well plates with Dulbecco's Modified Essential Medium (DMEM) and challenged with crude and venom fractions. The murine renal cortex cells exhibited epithelial morphology and the majority showed smooth muscle actin determined by immune-staining. The cytotoxicity was evaluated by the tetrazolium colorimetric method. Cell viability was less for crude venom, followed by the hemorrhagic and neurotoxic fractions with a CT50 of 4.93, 18.41 and 50.22 µg/mL, respectively. The Vero cell cultures seemed to be more sensitive with a CT50 of 2.9 and 1.4 µg/mL for crude venom and the hemorrhagic peak, respectively. The results of this study show the potential of using cell culture system to evaluate venom toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of American cutaneous leishmaniasis (ACL) is frequently based on clinical and epidemiological data associated with the results of laboratory tests. Some laboratory methods are currently being applied for the diagnosis of ACL, among them the indirect immunofluorescence reaction (IIFR), the Montenegro skin test (MST), histopathological examination, and the polymerase chain reaction (PCR). The performance of these methods varies in a considerable proportion of patients. After the standardization of an immunoenzymatic test (ELISA) for the detection of IgG in the serum of patients with ACL using a crude Leishmania braziliensis antigen, the results obtained were compared to those of other tests routinely used for the diagnosis. The tests revealed the following sensitivity, when analyzed separately: 85% for ELISA IgG, 81% for PCR, 64.4% for MST, 58.1% for IIFR, and 34% for the presence of parasites in the biopsy. ELISA was positive in 75% of patients with ACL presenting a negative MST, in 84.8% of ACL patients with negative skin or mucous biopsies for the presence of the parasite, and in 100% of cases with a negative PCR. Thus, ELISA presented a higher sensitivity than the other tests and was useful as a complementary method for the diagnosis of ACL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DNA amplification techniques are being used increasingly in clinical laboratories to confirm the identity of medically important bacteria. A PCR-based identification method has been in use in our centre for 10 years for Burkholderia pseudomallei and was used to confirm the identity of bacteria isolated from cases of melioidosis in Ceará since 2003. This particular method has been used as a reference standard for less discriminatory methods. In this study we evaluated three PCR-based methods of B. pseudomallei identification and used DNA sequencing to resolve discrepancies between PCR-based results and phenotypic identification methods. The established semi-nested PCR protocol for B. pseudomallei 16-23s spacer region produced a consistent negative result for one of our 100 test isolates (BCC #99), but correctly identified all 71 other B. pseudomallei isolates tested. Anomalous sequence variation was detected at the inner, reverse primer binding site for this method. PCR methods were developed for detection of two other B. pseudomallei bacterial metabolic genes. The conventional lpxO PCR protocol had a sensitivity of 0.89 and a specificity of 1.00, while a real-time lpxO protocol performed even better with sensitivity and specificity of 1.00, and 1.00. This method identified all B. pseudomallei isolates including the PCR-negative discrepant isolate. The phaC PCR protocol detected the gene in all B. pseudomallei and all but three B. cepacia isolates, making this method unsuitable for PCR-based identification of B. pseudomallei. This experience with PCR-based B. pseudomallei identification methods indicates that single PCR targets should be used with caution for identification of these bacteria, and need to be interpreted alongside phenotypic and alternative molecular methods such as gene sequencing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herpes simplex virus type 1 (HSV-1) ophthalmic disease is the most common cause of corneal blindness in humans world-wide. Current culture techniques for HSV take several days and commercially available HSV laboratory based diagnostic techniques vary in sensitivity. Our study was conducted to evaluate the use of a quicker and simpler method to herpes ophthalmic diagnosis. Corneal smears were made by firm imprints of infected mouse eyes to glass slides, after smears were fixated with cold acetone, and an indirect immunofluorescence (IIF) method was performed using monoclonal antibodies in a murine model of ophthalmic herpes. Eye swabs from infected mice were inoculated in Vero cells for virus isolation. Cytology and histology of the eye were also performed, using hematoxylin-eosin routine. Mouse eyes were examined by slit-lamp biomicroscopy for evidence of herpetic disease at various times postinoculation. We made a comparative evaluation of sensitivity, specificity and speed of methods for laboratory detection of HSV. Our results indicate that this IIF method is quick, sensitive, specific and can be useful in the diagnosis of ophthalmic herpes as demonstrated in an animal model.