81 resultados para Pin on disc tests
Resumo:
Malaria diagnoses has traditionally been made using thick blood smears, but more sensitive and faster techniques are required to process large numbers of samples in clinical and epidemiological studies and in blood donor screening. Here, we evaluated molecular and serological tools to build a screening platform for pooled samples aimed at reducing both the time and the cost of these diagnoses. Positive and negative samples were analysed in individual and pooled experiments using real-time polymerase chain reaction (PCR), nested PCR and an immunochromatographic test. For the individual tests, 46/49 samples were positive by real-time PCR, 46/49 were positive by nested PCR and 32/46 were positive by immunochromatographic test. For the assays performed using pooled samples, 13/15 samples were positive by real-time PCR and nested PCR and 11/15 were positive by immunochromatographic test. These molecular methods demonstrated sensitivity and specificity for both the individual and pooled samples. Due to the advantages of the real-time PCR, such as the fast processing and the closed system, this method should be indicated as the first choice for use in large-scale diagnosis and the nested PCR should be used for species differentiation. However, additional field isolates should be tested to confirm the results achieved using cultured parasites and the serological test should only be adopted as a complementary method for malaria diagnosis.
Resumo:
In this paper, we assessed the suitability of using the neonicotinoid imidacloprid with standard ovitraps by evaluating the ovicidal properties of imidacloprid and its influence on the oviposition response of gravid females of Aedes (Stegomyia) aegypti Linnaeus (Diptera: Culicidae). First, we calculated the imidacloprid lethal dose 99 (LD99) by exposing third instar larvae of the target species to different concentrations of the insecticide. Next, Ae. aegypti eggs were exposed to the imidacloprid LD99 for 24 h and hatching inhibition was recorded. Finally, we investigated any potential repellent effect of the imidacloprid solution on the oviposition response of gravid Aedes females in field and laboratory conditions. The LD99 obtained from larvae tests proved to be sufficient to keep any exposed eggs from hatching. No repellent effect was observed; females laid as many eggs in imidacloprid-treated ovitraps as in traps containing either clean water or temephos-treated water in both field and laboratory conditions. Our results indicate that imidacloprid is a suitable insecticide for treating ovitraps against Ae. aegypti.
Resumo:
Orally transmitted Chagas disease (ChD), which is a well-known entity in the Brazilian Amazon Region, was first documented in Venezuela in December 2007, when 103 people attending an urban public school in Caracas became infected by ingesting juice that was contaminated with Trypanosoma cruzi. The infection occurred 45-50 days prior to the initiation of the sampling performed in the current study. Parasitological methods were used to diagnose the first nine symptomatic patients; T. cruzi was found in all of them. However, because this outbreak was managed as a sudden emergency during Christmas time, we needed to rapidly evaluate 1,000 people at risk, so we decided to use conventional serology to detect specific IgM and IgG antibodies via ELISA as well as indirect haemagglutination, which produced positive test results for 9.1%, 11.9% and 9.9% of the individuals tested, respectively. In other more restricted patient groups, polymerase chain reaction (PCR) provided more sensitive results (80.4%) than blood cultures (16.2%) and animal inoculations (11.6%). Although the classical diagnosis of acute ChD is mainly based on parasitological findings, highly sensitive and specific serological techniques can provide rapid results during large and severe outbreaks, as described herein. The use of these serological techniques allows prompt treatment of all individuals suspected of being infected, resulting in reduced rates of morbidity and mortality.
Resumo:
A single strain of Mycobacterium abscessus subsp. bolletii, characterised by a particular rpoB sequevar and two highly related pulsed field gel electrophoresis patterns has been responsible for a nationwide outbreak of surgical infections in Brazil since 2004. In this study, we developed molecular tests based on polymerase chain reaction restriction-enzyme analysis (PRA) and sequencing for the rapid identification of this strain. Sequences of 15 DNA regions conserved in mycobacteria were retrieved from GenBank or sequenced and analysed in silico. Single nucleotide polymorphisms specific to the epidemic strain and located in enzyme recognition sites were detected in rpoB, the 3' region of the 16S rDNA and gyrB. The three tests that were developed, i.e., PRA-rpoB, PRA-16S and gyrB sequence analysis, showed 100%, 100% and 92.31% sensitivity and 93.06%, 90.28% and 100% specificity, respectively, for the discrimination of the surgical strain from other M. abscessus subsp. bolletii isolates, including 116 isolates from 95 patients, one environmental isolate and two type strains. The results of the three tests were stable, as shown by results obtained for different isolates from the same patient. In conclusion, due to the clinical and epidemiological importance of this strain, these tests could be implemented in reference laboratories for the rapid preliminary diagnosis and epidemiological surveillance of this epidemic strain.
Resumo:
The diagnosis of leprosy continues to be based on clinical symptoms and early diagnosis and treatment are critical to preventing disability and transmission. Sensitive and specific laboratory tests are not available for diagnosing leprosy. Despite the limited applicability of anti-phenolic glycolipid-I (PGL-I) serology for diagnosis, it has been suggested as an additional tool to classify leprosy patients (LPs) for treatment purposes. Two formats of rapid tests to detect anti-PGL-I antibodies [ML immunochromatography assay (ICA) and ML Flow] were compared in different groups, multibacillary patients, paucibacillary patients, household contacts and healthy controls in Brazil and Nepal. High ML Flow intra-test concordance was observed and low to moderate agreement between the results of ML ICA and ML Flow tests on the serum of LPs was observed. LPs were "seroclassified" according to the results of these tests and the seroclassification was compared to other currently used classification systems: the World Health Organization operational classification, the bacilloscopic index and the Ridley-Jopling classification. When analysing the usefulness of these tests in the operational classification of PB and MB leprosy for treatment and follow-up purposes, the ML Flow test was the best point-of-care test for subjects in Nepal and despite the need for sample dilution, the ML ICA test yielded better performance among Brazilian subjects. Our results identified possible ways to improve the performance of both tests.
Resumo:
There is insufficient evidence of the usefulness of dengue diagnostic tests under routine conditions. We sought to analyse how physicians are using dengue diagnostics to inform research and development. Subjects attending 14 health institutions in an endemic area of Colombia with either a clinical diagnosis of dengue or for whom a dengue test was ordered were included in the study. Patterns of test-use are described herein. Factors associated with the ordering of dengue diagnostic tests were identified using contingency tables, nonparametric tests and logistic regression. A total of 778 subjects were diagnosed with dengue by the treating physician, of whom 386 (49.5%) were tested for dengue. Another 491 dengue tests were ordered in subjects whose primary diagnosis was not dengue. Severe dengue classification [odds ratio (OR) 2.2; 95% confidence interval (CI) 1.1-4.5], emergency consultation (OR 1.9; 95% CI 1.4-2.5) and month of the year (OR 3.1; 95% CI 1.7-5.5) were independently associated with ordering of dengue tests. Dengue tests were used both to rule in and rule out diagnosis. The latter use is not justified by the sensitivity of current rapid dengue diagnostic tests. Ordering of dengue tests appear to depend on a combination of factors, including physician and institutional preferences, as well as other patient and epidemiological factors.