82 resultados para Michelson interference
Resumo:
ELISAs have been applied to pesticide residue analysis due to their high sensitivity and selectivity. However, some ELISAs performance may be affected by matrix components. In this work, ELISA for carbaryl in water samples was checked for interference by naturally occurring fulvic acids. The results suggested that the high fulvic acid concentration (³30 mg L-1) and acidic pH conditions (pH 4.0) interfere with the signal detection decreasing the method sensitivity. A dilution of the samples and adjust to pH 8.0 are appropriate to minimize the matrix interferences in the ELISA method. Good correlation between ELISA and HPLC-DAD results was observed.
Resumo:
The aim of this work was to evaluate the adsorption conditions of zinc and cadmium ions from aqueous solutions using a comercially available peat from Balneário Arroio do Silva, Santa Catarina State, Brazil. Adsorption studies were carried out in column experiments using radiotracers of the studied metals (65Zn and 115Cd). The pH influence and the interference of other ions, such as Na+, Ca2+, Fe3+ and Al3+on the adsorption process were investigated. The results showed that peat columns are able to retain more than 99% of metal ions in solution in a range of pH from 3,7 to 6,5. Ca2+ and Al3+ ions were the main interferent on adsorption of Zn and Cd ions in solution.
Resumo:
Simultaneous electrolytic deposition is proposed for minimization of Cu2+ and Pb2+ interferences on automated determination of Cd2+ by the Malachite Green-iodide reaction. During electrolysis of sample in a cell with two Pt electrodes and a medium adjusted to 5% (v/v) HNO3 + 0.1% (v/v) H2SO4 + 0.5 mol L-1 NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. With 60 s electrolysis time and 0.25 A current, Pb2+ and Cu2+ levels up to 50 and 250 mg L-1 respectively, can be tolerated without interference. With on-line extraction of Cd2+ in anionic resin minicolumn, calibration graph in the 5.00 - 50.0 µg Cd L-1 range is obtained, corresponding to twenty measurements per hour, 0.7 mg Malachite Green and 500 mg KI and 5 mL sample consumed per determination. Results of the determination of Cd in certified reference materials, vegetables and tap water were in agreement with certified values and with those obtained by GFAAS at 95% confidence level. The detection limit is 0.23 µg Cd L-1 and the RSD for typical samples containing 13.0 µg Cd L-1 was 3.85 % (n= 12).
Resumo:
A differential pulse polarographic study with the objective to determine iron (III) in presense of copper (II) in a supporting electrolyte based on citrate - EDTA was made. The best experimental conditions found were a supporting electrolyte of citrate 0.25 mol L-1, EDTA 0.050 mol L-1 and KNO3 0.50 mol L-1, pH 5.00. In this media iron (III) showed a polarographic peak in -0.08 V and the copper (II) in -0.34 V, both vs. Ag/AgCl (saturated KCl). Thus, a analytical method was developed and applied to determine iron (III) in brass alloy, a matrix were copper is in large excess over iron. The results obtained showed no interference of copper in the iron determination. The value of 0.21% of iron in the sample alloy composition was obtained and the method was validated by atomic absortion and recovery test, and the results exhibited a good agreement with the proposed method.
Resumo:
Pesticide residues are determined by thin layer chromatography (TLC) using the Hill reaction as a detection method. Tomatoes samples without pesticide were fortified with atrazine, diuron, chloroxuron and metribuzin, and were applyed in silica gel plates with the help of a microsyringe. The pesticides were elued with ethyl acetate. There was no need of cleaning up because no interference was noticed. After the revelation of the plates, the diameters of the spots were measure by using a rule. The range of the determined concentration for all the pesticides was from 0.1 to1.0 ng/muL. The results obtained through TLC can be used for semi-quantitative analysis.The results obtained were compared to gas and liquid chromatography, showing good agreement between both techniques.
Resumo:
An alternative analytical method for nitrogen dioxide (NO2) in atmosphere was developed. The collection of NO2 is performed by a Sep-Pack C-18 cartridge impregnated with 11% (v/v) of triethanolamine plus 3,6 % (v/v) of ethylene glycol plus 25 % (v/v) of acetone combined solution. When the impregnating is used, NO2 is collected with good repeatibility (CV = 3,3 %). The NO2 absorbed in the sampler was stripped from the sorbent with a methanol 5% (v/v) aqueous solution and was determined by colorimetry as nitrite by using the Griess-Saltzman reagent. The detection limit of 1,4 ppb for 60 min sampling at 0,5 L min-1 flow rate was obtained. Preparation and conditioning procedures for TEA-C-18 cartridge, sampling flow rate, absorption capacity and interference of other species are discussed.
Resumo:
Acidic hydrolysis of samples is frequent in urinary 2,5-hexanodione determination. This hydrolysis should be performed under proper conditions, in order to avoid interference, such as the presence of 2,5-dimethylfurane and 2-acetylfurane. The results of the present work, as well as data from the literature, show that the use of non-polar or slightly polar chromatographic columns of 30 m length is an essential condition for 2,5-HD determination in an acid hydrolysed urine sample. In the same way the pH should be kept between 0.3 and 0.5. The mean concentrations of 2,5-HD in samples submitted to hydrolysis (0.50 ± 0.28 mg/g of creatinine) was about 3 times higher than those found in the samples without acid hydrolysis (0.19 ± 0.3 mg/g of creatinine).