136 resultados para Fluorescent Antibody Test (FAT)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Antigens of a bovine herpesvirus type 5 (BHV-5), isolated from a cow with a neurological infection in Rio Grande do Sul State, Brazil, were used to immunize BALB/c mice to produce monoclonal antibodies (mAbs). Eleven hybridomas secreting mAbs directed at BHV-5 antigens were obtained after two fusions and screening of 356 hypoxanthine-aminopterin-thymidine-resistant clones. The mAbs reacted at dilutions up to 1:500 (hybridoma culture supernatant) and up to >1:10,000 (ascitic fluid) in an indirect fluorescent antibody assay (IFA) and in immunoperoxidase staining of BHV-5-infected cells. Four mAbs (1D12, 2E2, 2G10 and 4E4) showed virus-neutralizing activity against the parental BHV-5 isolate. Five mAbs (1F3, 2A6, 2F9, 2G10 and HB24L) reacted in Western immunoblotting with a protein of approximately 90 kDa. Three other mAbs (2E2, 3D6 and 4E4) reacted in IFA with antigens of a BHV-1 mutant glycoprotein C- negative strain, demonstrating that they are directed at a viral antigen other than glycoprotein C. The eleven mAbs tested reacted with 20 BHV-5 field isolates and nine mAbs reacted with 10 BHV-1 isolates. Two mAbs (1F3 and 2F9) failed to react with BHV-1 field isolates, although they displayed a weak and nonreproducible reaction with the BHV-1 reference strain Los Angeles. These mAbs may be very useful in distinguishing between BHV-1 and BHV-5 infections since most of the traditional reagents and techniques are unable to do so. One mAb (2F9) was shown to bind to viral antigens by immunohistochemistry of histological sections of the brain of a BHV-5-infected calf. These results demonstrate that the mAbs produced here are suitable for use in a variety of immunological techniques and therefore may be useful for diagnostic and research purposes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A direct immunofluorescent antibody (DIFMA) test using a Leishmania genus- specific monoclonal antibody was evaluated in the routine diagnosis of cutaneous leishmaniasis (CL) in Ecuador. This test was compared with the standard diagnostic techniques of scrapings, culture and histology. Diagnostic samples were taken from a total of 90 active dermal ulcers from patients from areas of Ecuador known to be endemic for cutaneous leishmaniasis. DIFMA was positive in all lesions. It was shown to be significantly superior to standard diagnostic methods either alone or in combination. The sensitivity of DIFMA did not diminish with chronicity of lesions. This test proved to be extremely useful in the routine diagnosis of CL because it is highly sensitive, is easy to use and produces rapid results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: The diagnosis of dengue and the differentiation between primary and secondary infections are important for monitoring the spread of the epidemic and identifying the risk of severe forms of the disease. The detection of immunoglobulin (Ig)M and IgG antibodies is the main technique for the laboratory diagnosis of dengue. The present study assessed the application of a rapid test for dengue concerning detection of new cases, reinfection recognition, and estimation of the epidemic attack rate. METHODS: This was a retrospective, cross-sectional, descriptive study on dengue using the Fortaleza Health Municipal Department database. The results from 1,530 tested samples, from 2005-2006, were compared with data from epidemiological studies of dengue outbreaks in 1996, 2003, and 2010. RESULTS: The rapid test confirmed 52% recent infections in the tested patients with clinical suspicion of dengue: 40% detected using IgM and 12% of new cases using IgG in the non-reactive IgM results. The positive IgM plus negative IgG (IgM+ plus IgG-) results showed that 38% of those patients had a recent primary dengue infection, while the positive IgG plus either positive or negative IgM (IgG+ plus IgM+/-) results indicated that 62% had dengue for at least a second time (recent secondary infections). This proportion of reinfections permitted us to estimate the attack rate as >62% of the population sample. CONCLUSIONS: The rapid test for dengue has enhanced our ability to detect new infections and to characterize them into primary and secondary infections, permitting the estimation of the minimal attack rate for a population during an outbreak.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The high sensitivity and the ability to diagnose schistosomiasis in a very early phase after infection have indicated the detection of IgM antibodies to Schistosoma mansoni gut antigens by the immunofluorescence test (IgM-IFT) as a useful serological test for epidemiological studies in low endemic areas. When applied in a follow-up study for two years, higher rates of seroconversion from IFT negative to positive were observed during the summer months, suggesting seasonal transmission of schistosomiasis in the rural area of the municipality of Itariri (São Paulo, Brazil). In each survey, blood samples from about 600 schoolchildren were collected on filter paper and submitted to IgM-IFT. When the blood samples were classified for the IgM antibody levels, according to the intensity of fluorescent reaction observed at fluorescence microscopy, and correlated to the egg counts in the Kato-Katz positive patients, no association was observed. This observation might suggest that the intensity of fluorescence observed in the IgM-IFT, as an indicator of IgM antibody levels, could not be an useful seroepidemiological marker for classifying areas of low endemicity according to degrees of infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The determination of anti-HBs as a screening test before vaccination has been advisable in order to encounter immune individuals that don't need to receive vaccine protection. A case-report is presented and three other cases are reviewed from the literature. Anti-HBs was positive in these health-care personnels that developped typical acute B hepatitis. Different subtyping involving the d/y determinants were found in the first case, but false-positive anti-HBs even with high titres, determined by RIA, were found in the other cases. Concomitant determination of anti-HBc or absence of screening tests seem to be more reasonable policies until a low-cost and risk-free vaccine is produced.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lectins were labeled with fluorescein and tried as conjugates in the immunofluorescence (IP) test for the detection of IgM antibodies to T. gondii, in the diagnosis of acute toxoplasmosis. This approach was an attempt to find alternative reagents for anti-human IgM fluorescent conjugates (AHIgMFC), which contain quite frequently anaibcdies to toxoplasma, as contaminants, due to natural T. gondii infections among animals used for imunization. Lentil (Lens culinaris) lectin fluorescence conjugates (LcFC) provided most satisfactory results. The evaluation of LcFC carried out in a total of 179 sera from patients with acute and chronic toxoplasmosis, with non-related infections or healthy subjects, gave high values of relative efficiency, co-positivity and co-negativity indices, respectively 0.989, 0.969 and 1.000, in reference to the conventional AHIgMFC. Moreover, three batches of LcFC successively prepared gave reproducible test results. The advantage of LcFC as an alternative reagent for the serodiagnosis of acute toxoplasmosis is supported by practical aspects of its preparation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A comparison of two different standardized reagent procedures for the passive haemagglutination test (PHA) in the detection of specific antibody to Cysticercus cellulosae in cerebrospinal fluid (CSF) was carried out. The formaldehyde-treated group O Rh-human red blood cells (HuRBC) and glutaraldehyde-treated sheep red blood cells (SRBC) were the supplies for the reagents preparation and, in the tests, they were designated as PHA-1 and PHA-2, respectively. For both reagents the cells were coated with the cysticerci total saline extract (TS) antigen. PHA-1 and PHA-2 were assessed in a total of 204 CSF from patients with neurocysticercosis, from non-related infections and from healthy individuals. The positivity and specificity indices obtained were respectively 81.7% and 94.4% for PHA-1 and for PHA-2, 88.7% and 96.6%. Since no significant differences were observed between the results provided by two reagents, at level of significance of 0.05, either processes of cell sensitization can alternatively be used according to the own laboratory convenience.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A serological study was carried out to evaluate the causal relationship of acute diarrhoea and rotavirus in children under five years of age. The rotaviral infection was demonstrated in paired sera by determining the antibody titers by immunofluorescence test (IF). Bovine rotavirus-infected MA-104 cell culture was used as substratum for IF. Out of 80 paired sera it was shown that 23 (28.75%) presented seroconversion, 19 (23.75%) samples showed a twofold increase in their titers and 38 (47.5%) had no increase in rotavirus antibody. This result is discussed on the light of previously obtained results on viral antigen detection by counterimmunoelectrosmophoresis (CIEOP).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Indirect Immunofluorescence (IFA), Plaque Reduction Neutralization (PRN) and Haemagglutination Inhibition (HI) tests for measles antibodies were carried out in 197 sera obtained from umbilical cord and vaccinated children. The IFA was also applied to blood samples collected with filter paper. IFA results demonstrated that the test is relatively simple to perform, with good reproducibility for different antigen lots. Good correlation was obtained between IFA, PRN and HI antibody titers. Better correlation was demonstrated with IFA and PRN than with HI and PRN tests. Sensitivity of IFA in detecting antibody was less effective than PRN, however more effective than HI using rhesus monkey red blood cells. PRN antibody titers over 100 were detected by IFA but not by HI (9.7% with negative results). IFA may be of considerable practical use and able to substitute HI in Seroepidemiological surveys and to evaluate vaccine efficacy. It also can be simplified by employing filter paper collected samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Serum sample obtained from a male, 12 year old patient suffering from Guillain-Barré syndrome (GBS) was positive for human T-lymphotropic virus (HTLV-I) antibody by the enzyme-linked immunosorbent assay (ELISA) and the Western Blot analysis (WB). Attempts to isolate enteroviruses (including poliovirus) from faecal material in both tissue culture and suckling mice were unsuccessful; in addition, acute and convalescent paired serum samples did not show any evidence of recent poliovirus infection when tested against the three serotypes. Specific tests for detection of Epstein-Barr virus infection were not performed; however, the Paul-Bunnel test yielded negative results. ELISA for detection of anti-cytomegalovirus IgM was also negative. The concomitant occurrence of either adult T cell leukemia (ATL) or lymphoma was not recorded in this case.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simplified fluorescence inhibition microtest (SFIMT) was standardized for the evaluation of antirabies serum neutralizing antibodies based on the rapid fluorescent focus inhibition test (RFFIT) and the fluorescence inhibition microtest (FIMT). The simplified test showed reproductibility similar to that of the FIMT with advantages as easier executation and quicker reading. A simple pre-treatment of Brazilian microplates produced for immune enzymatic assays (PROSIL) gave equivalent results and substantial coast reduction, in relation to imported plates (DIFCO). The simplified test can be easily implemented in less sophisticated laboratories, as alternative to the mouse serum neutralization test, still the most largely employed in Brazil, or even to others as RFFIT and FIMT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Amebiasis continues to be of epidemiological importance in underdeveloped countries. Clinical diagnosis and epidemiological setting in a region are based on the fecal microscopic identification of cysts or trophozoites. This procedure requires well trained personnel, is laborious, of low sensitivity and frequently yields false-positives results. The present study was designed to develop an immuno-enzymatic fecal 96 kDa antigen capture test (COPROELISA-Eh) more sensitive and specific than microscopic diagnosis of amebiasis. Triplicates of 177 stool samples processed by the formol-ether concentration method, were defined as positive or negative by three experienced microscopic observers. Another aliquot was submitted to the antigen capture test by a monoclonal antibody against a specific membrane antigen of pathogenic strains of Entamoeba histolytica. Optical densities were interpreted as positive when they exceeded the mean value of negative samples plus two standard deviations. COPROELISA-Eh showed a 94.4% sensitivity, 98.3% specificity, 96.2% positive predictive value and 97.6% negative predictive value for the detection of E. histolytica in feces. COPROELISA-Eh is more sensitive and specific than microscopic examination, does not require specially trained personnel and allows the simultaneous processing of a large number of samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three months after a mass vaccination campaign (coverage: 100%) against measles a random seroepidemiological survey was carried out in students aged 1 to 19 years old in the Municipality of Niterói, State of Rio de Janeiro. Blood samples were tested for measles antibodies by enzyme immunosorbent assay (EIA) and negative cases were tested again using hemagglutination inhibition (HI) and plaque reduction neutralization (PRN). Of the 798 samples tested by EIA, 718 (90.2%) were positive for measles antibodies. PRN test was more sensitive than EIA and HI in detecting measles specific antibodies. The total antibody prevalence increased from 90.2% to 93.2% when HI was employed in EIA negative specimens and to 98.9% when PRN was used. After the mass vaccination campaign a marked decrease in measles incidence was observed in the municipality studied, showing the effectiveness of the strategy used for measles control in developing countries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The persistence, in some subjects, of specific IgM antibodies to Toxoplasma gondii for several months after the acute phase of infection has complicated the interpretation of serological test results for toxoplasmosis. Several reports have emphasized the value of the detection of Toxoplasma-specific IgA antibodies for the diagnosis of acute toxoplasmosis. In this article, we report the follow-up profiles of Toxoplasma-specific IgM and IgA antibodies in serum samples obtained from 12 patients at various intervals after the onset of the clinical manifestations of infection. IgM antibodies were detected by the indirect immunofluorescence (IIF) test, antibody capture enzyme-linked immunosorbent assay (cELISA) and enzyme-mediated chemilluminescent technique (CmL). IgA antibodies were quantified by the direct ELISA (dELISA) and cELISA procedures. As defined by the manufacturer of the cELISA test for IgA used, most patients with acute toxoplasmosis have antibody levels > 40 arbritary units per ml (AU/ml). At values > 40 AU/ml, the cELISA for IgA detected significant antibody levels for a shorter time than the other techniques used for IgM and IgA detection. However, IgA levels £ 40 AU/ml do not exclude the possibility of acute toxoplasmosis since such levels can be reached very soon after infection with T. gondii. The results obtained in the present study show that the serological diagnosis of acute toxoplasmosis may not be such an easy task. Our data suggest that use of the IgA-cELISA concomitantly with IgM antibody screening could permit, in some circumstances, a more efficient diagnosis of acute acquired toxoplasmosis

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A survey for canine tegumentary leishmaniasis (CTL) has been carried out between 1986 and 1993 in seven endemic localities for American cutaneous leishmaniasis in the State of Rio de Janeiro. 270 dogs have been examined for their clinical aspects, the development of delayed hypersensitivity (DHS) with Immunoleish antigen and with immunofluorescent antibody research of IgG (IF). 28.2% of them had ulcer lesions and 3.3% had scars. The lesions consisted of single (39.5%) and mucocutaneous lesions (31.6%), multiple cutaneous (25.0%) and mucocutaneous lesions associated with cutaneous ulcers (4.0%). Twelve (15.8%) isolates from biopsies were analyzed by zimodeme and schizodeme and identified as L. (V.) braziliensis. The overall prevalence of canine infection that was evaluated with the skin test was of 40.5% and with IF it was of 25.5%. Both tests showed a high positive rate with relation to the animals with mucosal lesions, as in the case of human mucocutaneous leishmaniasis. The comparison of the two tests showed the skin test to have a better performance although there was no statistical difference (p>0.05) between them. The proportional sensitivity and specificity was of 84.0% and 74.0%, respectively. The Immunoleish skin test and IF are useful tools to be employed in CTL field epidemiological surveys.