90 resultados para Diagnostic Test Accuracy
Resumo:
Haemonchus contortus is one of the most common and economically significant causes of disease in small ruminants worldwide, and the control programs of parasitic nematodes - including H. contortus - rely mostly on the use of anthelmintic drugs. The consequence of the use of this, as the sole sanitary strategy to avoid parasite infections, was the reduction of the efficacy of all chemotherapeutic products with a heavy selection for resistance. The widespread of anthelmintic resistance and the difficulty of its early diagnosis has been a major concern for the sustainable parasite management on farms. The objective of this research was to determine and compare the ivermectin (IVM) and moxidectin (MOX) effect in a selected field strain of H. contortus with a known resistance status, using the in vitro larval migration on agar test (LMAT). Third stage larvae of the selected isolate were obtained from faecal cultures of experimentally infected sheep and incubated in eleven increasing diluted concentrations of IVM and MOX (6, 12, 24, 48, 96, 192, 384, 768, 1536, 3072 and 6144µg/mL). The dose-response sigmoidal curves were obtained using the R² value of >0.90 and the lethal concentration (LC50) dose for the tested anthelmintic drugs using a four-parameter logistic model. The LC50 value for MOX was significantly lower than IVM (1.253µg/mL and 91.06µg/mL), identifying the H. contortus isolate as considerably less susceptible to IVM compared to MOX. Furthermore, the LMAT showed a high consistency (p<0.0001) and provided to be a useful diagnostic tool for monitoring the resistance status of IVM and MOX in H. contortus field isolate, as well as it may be used for official routine drug monitoring programs under the Ministry of Agriculture (MAPA) guidance.
Resumo:
Conidiobolomycosis is a granulomatous disease caused by the fungus Conidiobolus spp. in humans and animals. Traditional technique for diagnosis of the disease is isolation of the agent associated with the presence of typical clinical signs and pathological conditions. The aim of this study was to describe the development of a specific polymerase chain reaction (PCR) test for Conidiobolus lamprauges to detect the fungus in clinical samples. Samples from suspected animals were collected and submitted to isolation, histopathological analysis and amplification by PCR. DNA from tissues was subjected to PCR with fungi universal primers 18S rDNA gene, and specific primers were designed based on the same gene in C. lamprauges that generated products of about 540 bp and 222 bp respectively. The culture was positive in 26.6% of clinical samples. The PCR technique for C. lamprauges showed amplification of DNA from fresh tissues (80%) and paraffin sections (44.4%). In conclusion, the PCR technique described here demonstrated a high sensitivity and specificity for detection of fungal DNA in tissue samples, providing a tool for the rapid diagnosis of C. lamprauges.
Resumo:
The accuracy of modelling of rotor systems composed of rotors, oil film bearings and a flexible foundation, is evaluated and discussed in this paper. The model validation of different models has been done by comparing experimental results with numerical results by means. The experimental data have been obtained with a fully instrumented four oil film bearing, two shafts test rig. The fault models are then used in the frame of a model based malfunction identification procedure, based on a least square fitting approach applied in the frequency domain. The capability of distinguishing different malfunctions has been investigated, even if they can create similar effects (such as unbalance, rotor bow, coupling misalignment and others) from shaft vibrations measured in correspondence of the bearings.
Resumo:
The use of the flow vs time relationship obtained with the nasal prongs of the AutoSetä (AS) system (diagnosis mode) has been proposed to detect apneas and hypopneas in patients with reasonable nasal patency. Our aim was to compare the accuracy of AS to that of a computerized polysomnographic (PSG) system. The study was conducted on 56 individuals (45 men) with clinical characteristics of obstructive sleep apnea (OSA). Their mean (± SD) age was 44.6 ± 12 years and their body mass index was 31.3 ± 7 kg/m2. Data were submitted to parametric analysis to determine the agreement between methods and the intraclass correlation coefficient was calculated. The Student t-test and Bland and Altman plots were also used. Twelve patients had an apnea-hypopnea index (AHI) <10 in bed and 20 had values >40. The mean (± SD) AHI PSG index of 37.6 (28.8) was significantly lower (P = 0.0003) than AHI AS (41.8 (25.3)), but there was a high intraclass correlation coefficient (0.93), with 0.016 variance. For a threshold of AHI of 20, AS showed 73.0% accuracy, 97% sensitivity and 60% specificity, with positive and negative predictive values of 78% and 93%, respectively. Sensitivity, specificity and negative predictive values increased in parallel to the increase in AHI threshold for detecting OSA. However, when the differences of AHI PSG-AS were plotted against their means, the limits of agreement between the methods (95% of the differences) were +13 and -22, showing the discrepancy between the AHI values obtained with PSG and AS. Finally, cubic regression analysis was used to better predict the result of AHI PSG as a function of the method proposed, i.e., AHI AS. We conclude that, despite these differences, AHI measured by AutoSetä can be useful for the assessment of patients with high pre-test clinical probability of OSA, for whom standard PSG is not possible as an initial step in diagnosis.
Resumo:
The use of limiting dilution assay (LDA) for assessing the frequency of responders in a cell population is a method extensively used by immunologists. A series of studies addressing the statistical method of choice in an LDA have been published. However, none of these studies has addressed the point of how many wells should be employed in a given assay. The objective of this study was to demonstrate how a researcher can predict the number of wells that should be employed in order to obtain results with a given accuracy, and, therefore, to help in choosing a better experimental design to fulfill one's expectations. We present the rationale underlying the expected relative error computation based on simple binomial distributions. A series of simulated in machina experiments were performed to test the validity of the a priori computation of expected errors, thus confirming the predictions. The step-by-step procedure of the relative error estimation is given. We also discuss the constraints under which an LDA must be performed.
Resumo:
Pheochromocytomas are rare chromaffin cell tumors that nevertheless must be excluded in large numbers of patients who develop sustained or episodic hypertension as well as in many others with suggestive symptoms or with a familial history of pheochromocytoma. Diagnosis of pheochromocytoma depends importantly on biochemical evidence of excess catecholamine production by a tumor. Imperfect sensitivity and specificity of commonly available biochemical tests and the low incidence of the tumor among the tested population mean that considerable time and effort can be expended in confirming or ruling out pheochromocytoma in patients where the tumor is suspected. Measurements of plasma free metanephrines provide a superior test compared to other available tests for diagnosis of pheochromocytoma. In particular, the high sensitivity of plasma free metanephrines means that a normal test result reliably excludes all but the smallest of pheochromocytomas so that no other tests are necessary. Measurements of plasma free metanephrines, when systematically combined with other diagnostic procedures outlined in this review, provide a more efficient, reliable and cost-effective approach for diagnosis of pheochromocytoma than offered by previously available approaches.
Resumo:
Salivary cortisol is an index of plasma free cortisol and is obtained by a noninvasive procedure. We have been using salivary cortisol as a tool for physiological and diagnostic studies, among them the emergence of circadian rhythm in preterm and term infants. The salivary cortisol circadian rhythm in term and premature infants was established between 8 and 12 postnatal weeks. In the preterm infants the emergence of circadian rhythm was parallel to the onset of sleep rhythm. We also studied the use of salivary cortisol for screening for Cushing's syndrome (CS) in control and obese outpatients based on circadian rhythm and the overnight 1 mg dexamethasone (DEX) suppression test. Salivary cortisol was suppressed to less than 100 ng/dl after 1 mg DEX in control and obese patients. A single salivary cortisol measurement at 23:00 h and again after 1 mg DEX above the 90th percentile of the obese group values had sensitivity and specificity of 93 and 93% (23:00 h), and 91 and 94% (after DEX), respectively. The sensitivity improved to 100% when we combined both parameters. We also studied 11 CS children and 21 age-matched primary obese children for whom salivary cortisol sensitivity and specificity were 100/95% (23:00 h), and 100/95% (1 mg DEX), respectively. Similar to adults, sensitivity and specificity of 100% were obtained by combining 23:00 h and 1 mg DEX. The measurement of salivary cortisol is a useful tool for physiological studies and for the diagnosis of CS in children and adults on an outpatient basis.
Resumo:
The purpose of the present study was to validate the quantitative culture and cellularity of bronchoalveolar lavage (BAL) for the diagnosis of ventilator-associated pneumonia (VAP). A prospective validation test trial was carried out between 1992 and 1997 in a general adult intensive care unit of a teaching hospital. Thirty-seven patients on mechanical ventilation with suspected VAP who died at most three days after a BAL diagnostic procedure were submitted to a postmortem lung biopsy. BAL effluent was submitted to Gram staining, quantitative culture and cellularity count. Postmortem lung tissue quantitative culture and histopathological findings were considered to be the gold standard exams for VAP diagnosis. According to these criteria, 20 patients (54%) were diagnosed as having VAP and 17 (46%) as not having the condition. Quantitative culture of BAL effluent showed 90% sensitivity (18/20), 94.1% specificity (16/17), 94.7% positive predictive value and 88.8% negative predictive value. Fever and leukocytosis were useless for VAP diagnosis. Gram staining of BAL effluent was negative in 94.1% of the patients without VAP (16/17). Regarding the total cellularity of BAL, a cut-off point of 400,000 cells/ml showed a specificity of 94.1% (16/17), and a cut-off point of 50% of BAL neutrophils showed a sensitivity of 90% (19/20). In conclusion, BAL quantitative culture, Gram staining and cellularity might be useful in the diagnostic investigation of VAP.
Resumo:
The phonological loop is a component of the working memory system specifically involved in the processing and manipulation of limited amounts of information of a sound-based phonological nature. Phonological memory can be assessed by the Children's Test of Nonword Repetition (CNRep) in English speakers but not in Portuguese speakers due to phonotactic differences between the two languages. The objectives of the present study were: 1) to develop the Brazilian Children's Test of Pseudoword Repetition (BCPR), a Portuguese version of the CNRep, and 2) to validate the BCPR by correlation with the Auditory Digit Span Test from the Stanford-Binet Intelligence Scale. The BCPR and Digit Span were assessed in 182 children aged 4-10 years, 84 from Minas Gerais State (42 from a rural region) and 98 from the city of São Paulo. There are subject age and word length effects causing repetition accuracy to decline as a function of the number of syllables of the pseudowords. Correlations between BCPR and Digit Span forward (r = 0.50; P <= 0.01) and backward (r = 0.43; P <= 0.01) were found, and partial correlation indicated that higher BCPR scores were associated with higher Digit Span scores. BCPR appears to depend more on schooling, while Digit Span was more related to development. The results demonstrate that the BCPR is a reliable measure of phonological working memory, similar to the CNRep.
Resumo:
In a cross-sectional study conducted four years ago to assess the validity of the Brazilian version of the Eating Attitudes Test-26 (EAT-26) for the identification of abnormal eating behaviors in a population of young females in Southern Brazil, 56 women presented abnormal eating behavior as indicated by the EAT-26 and the Edinburgh Bulimic Investigation Test. They were each matched for age and neighborhood to two normal controls (N = 112) and were re-assessed four years later with the two screening questionnaires plus the Composite International Diagnostic Interview (CIDI). The EAT results were then compared to diagnoses originating from the CIDI. To evaluate the temporal stability of the two screening questionnaires, a test-retest design was applied to estimate kappa coefficients for individual items. Given the prevalence of eating disorders of 6.2%, the CIDI psychiatry interview was applied to 161 women. Of these, 0.6% exhibited anorexia nervosa and 5.6%, bulimia nervosa (10 positive cases). The validity coefficients of the EAT were: 40% sensitivity, 84% specificity, and 14% positive predictive value. Cronbach's coefficient was 0.75. For each EAT item, the kappa index was not higher than 0.344 and the correlation coefficient was lower than 0.488. We conclude that the EAT-26 exhibited low validity coefficients for sensitivity and positive predictive value, and showed a poor temporal stability. It is reasonable to assume that these results were not influenced by the low prevalence of eating disorders in the community. Thus, the results cast doubts on the ability of the EAT-26 test to identify cases of abnormal eating behaviors in this population.
Resumo:
Coronary artery disease (CAD) is a worldwide leading cause of death. The standard method for evaluating critical partial occlusions is coronary arteriography, a catheterization technique which is invasive, time consuming, and costly. There are noninvasive approaches for the early detection of CAD. The basis for the noninvasive diagnosis of CAD has been laid in a sequential analysis of the risk factors, and the results of the treadmill test and myocardial perfusion scintigraphy (MPS). Many investigators have demonstrated that the diagnostic applications of MPS are appropriate for patients who have an intermediate likelihood of disease. Although this information is useful, it is only partially utilized in clinical practice due to the difficulty to properly classify the patients. Since the seminal work of Lotfi Zadeh, fuzzy logic has been applied in numerous areas. In the present study, we proposed and tested a model to select patients for MPS based on fuzzy sets theory. A group of 1053 patients was used to develop the model and another group of 1045 patients was used to test it. Receiver operating characteristic curves were used to compare the performance of the fuzzy model against expert physician opinions, and showed that the performance of the fuzzy model was equal or superior to that of the physicians. Therefore, we conclude that the fuzzy model could be a useful tool to assist the general practitioner in the selection of patients for MPS.
Resumo:
Controversy exists regarding the diagnostic accuracy, optimal technique, and timing of exercise testing after percutaneous coronary intervention. The objectives of the present study were to analyze variables and the power of exercise testing to predict restenosis or a new lesion, 6 months after the procedure. Eight-four coronary multi-artery diseased patients with preserved ventricular function were studied (66 males, mean age of all patients: 59 ± 10 years). All underwent coronary angiography and exercise testing with the Bruce protocol, before and 6 months after percutaneous coronary intervention. The following parameters were measured: heart rate, blood pressure, rate-pressure product (heart rate x systolic blood pressure), presence of angina, maximal ST-segment depression, and exercise duration. On average, 2.33 lesions/patient were treated and restenosis or progression of disease occurred in 46 (55%) patients. Significant increases in systolic blood pressure (P = 0.022), rate-pressure product (P = 0.045) and exercise duration (P = 0.003) were detected after the procedure. Twenty-seven (32%) patients presented angina during the exercise test before the procedure and 16 (19%) after the procedure. The exercise test for the detection of restenosis or new lesion presented 61% sensitivity, 63% specificity, 62% accuracy, and 67 and 57% positive and negative predictive values, respectively. In patients without restenosis, the exercise duration after percutaneous coronary intervention was significantly longer (460 ± 154 vs 381 ± 145 s, P = 0.008). Only the exercise duration permitted us to identify patients with and without restenosis or a new lesion.
Resumo:
In order to evaluate the performance of a 1-h 75-g oral glucose tolerance test (OGTT) for the diagnosis of gestational diabetes mellitus (GDM), a cohort of 4998 women, 20 years or older, without previous diabetes being treated in prenatal care clinics in Brazil answered a questionnaire and performed a 75-g OGTT including fasting, 1-h and 2-h glucose measurements between their 24th and 28th gestational weeks. Pregnancy outcomes were transcribed from medical registries. GDM was defined according to WHO criteria (fasting: ≥126 mg/dL; 2-h value: ≥140 mg/dL) and macrosomia as a birth weight equal to or higher than 4000 g. Areas under the receiver operator characteristic curve (AUC) were compared and diagnostic properties of various cut-off points were evaluated. The AUCs for the prediction of macrosomia were 0.606 (0.572-0.637) for the 1-h and 0.589 (0.557-0.622) for the 2-h plasma glucose test. Similar predictability was demonstrable regarding combined adverse outcomes: 0.582 (0.559-0.604) for the 1-h test and 0.572 (0.549-0.595) for the 2-h test. When the 1-h glucose test was evaluated against a diagnosis of GDM defined by the 2-h glucose test, the AUC was 0.903 (0.886-0.919). The cut-off point that maximized sensitivity (83%) and specificity (83%) was 141 mg/dL, identifying 21% of the women as positive. A cut-off point of 160 mg/dL, with lower sensitivity (62%), had higher specificity (94%), labeling 8.6% as positive. Detection of GDM can be done with a 1-h 75-g OGTT: the value of 160 mg/dL has the same diagnostic performance as the conventional 2-h value (140 mg/dL). The simplification of the test may improve coverage and timing of the diagnosis of GDM.
Use of the caffeine-halothane contracture test for the diagnosis of malignant hyperthermia in Brazil
Resumo:
Malignant hyperthermia (MH) is a pharmacogenetic disease triggered by volatile anesthetics and succinylcholine. Deaths due to MH have been reported in Brazil. The first Malignant Hyperthermia Diagnostic and Research Center in Latin America was inaugurated in 1993 at the Federal University of Rio de Janeiro, Brazil. The center followed the diagnostic protocols of the North America MH Group, in which the contractures of biopsies from the vastus lateralis muscle are analyzed after exposure to caffeine and halothane (CHCT). CHCT was performed in individuals who survived, their relatives and those with signs/symptoms somewhat related to MH susceptibility (MHS). Here, we report data from 194 patients collected over 16 years. The Southeast (N = 110) and South (N = 71) represented the majority of patients. Median age was 25 (4-70) years, with similar numbers of males (104) and females (90). MHS was found in 90 patients and 104 patients were normal. Abnormal responses to both caffeine and halothane were observed in 59 patients and to caffeine or halothane in 20 and 11 patients, respectively. The contracture of biopsies from MHS exposed to caffeine and halothane was 1.027 ± 0.075 g (N = 285) and 4.021 ± 0.255 g (N = 226), respectively. MHS was found in patients with either low or high blood creatine kinase and also, with a low score on the clinical grading scale. Thus, these parameters cannot be used with certainty to predict MHS. We conclude that the CHCT protocol described by the North America MH Group contributed to identification of MHS in suspected individuals at an MH center in Brazil with 100% sensitivity and 65.7% specificity.
Resumo:
This study aimed to analyze the agreement between measurements of unloaded oxygen uptake and peak oxygen uptake based on equations proposed by Wasserman and on real measurements directly obtained with the ergospirometry system. We performed an incremental cardiopulmonary exercise test (CPET), which was applied to two groups of sedentary male subjects: one apparently healthy group (HG, n=12) and the other had stable coronary artery disease (n=16). The mean age in the HG was 47±4 years and that in the coronary artery disease group (CG) was 57±8 years. Both groups performed CPET on a cycle ergometer with a ramp-type protocol at an intensity that was calculated according to the Wasserman equation. In the HG, there was no significant difference between measurements predicted by the formula and real measurements obtained in CPET in the unloaded condition. However, at peak effort, a significant difference was observed between oxygen uptake (V˙O2)peak(predicted)and V˙O2peak(real)(nonparametric Wilcoxon test). In the CG, there was a significant difference of 116.26 mL/min between the predicted values by the formula and the real values obtained in the unloaded condition. A significant difference in peak effort was found, where V˙O2peak(real)was 40% lower than V˙O2peak(predicted)(nonparametric Wilcoxon test). There was no agreement between the real and predicted measurements as analyzed by Lin’s coefficient or the Bland and Altman model. The Wasserman formula does not appear to be appropriate for prediction of functional capacity of volunteers. Therefore, this formula cannot precisely predict the increase in power in incremental CPET on a cycle ergometer.