83 resultados para Creación gold standard


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of the present study was to compare the sensitivity and specificity of V3 enzyme immunoassay (solid phase EIA and EIA inhibition) and restriction fragment length polymorphism (RFLP) with the DNA sequencing "gold standard" to identify the Brazilian HIV-1 variants of subtype B and B"-GWGR. Peripheral blood mononuclear cells were collected from 61 HIV-1-infected individuals attending a clinic in São Paulo. Proviral DNA was amplified and sequentially cleaved with the Fok I restriction enzyme. Plasma samples were submitted to a V3-loop biotinylated synthetic peptide EIA. Direct partial DNA sequencing of the env gene was performed on all samples. Based on EIA results, the sensitivity for detecting B-GPGR was 70%, compared to 64% for the Brazilian variant B"-GWGR while, the specificity of B-GPGR detection was 85%, compared to 88% for GWGR. The assessment of RFLP revealed 68% sensitivity and 94% specificity for the B-GPGR strain compared to 84 and 90% for the B"-GWGR variant. Moreover, direct DNA sequencing was able to detect different base sequences corresponding to amino acid sequences at the tip of the V3 loop in 22 patients. These results show a similar performance of V3 serology and RLFP in identifying the Brazilian variant GWGR. However, V3 peptide serology may give indeterminate results. Therefore, we suggest that V3 serology be used instead of DNA sequencing where resources are limited. Samples giving indeterminate results by V3 peptide serology should be analyzed by direct DNA sequencing to distinguish between B-GPGR and the Brazilian variant B"-GWGR.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Several methods are used to estimate anaerobic threshold (AT) during exercise. The aim of the present study was to compare AT obtained by a graphic visual method for the estimate of ventilatory and metabolic variables (gold standard), to a bi-segmental linear regression mathematical model of Hinkley's algorithm applied to heart rate (HR) and carbon dioxide output (VCO2) data. Thirteen young (24 ± 2.63 years old) and 16 postmenopausal (57 ± 4.79 years old) healthy and sedentary women were submitted to a continuous ergospirometric incremental test on an electromagnetic braking cycloergometer with 10 to 20 W/min increases until physical exhaustion. The ventilatory variables were recorded breath-to-breath and HR was obtained beat-to-beat over real time. Data were analyzed by the nonparametric Friedman test and Spearman correlation test with the level of significance set at 5%. Power output (W), HR (bpm), oxygen uptake (VO2; mL kg-1 min-1), VO2 (mL/min), VCO2 (mL/min), and minute ventilation (VE; L/min) data observed at the AT level were similar for both methods and groups studied (P > 0.05). The VO2 (mL kg-1 min-1) data showed significant correlation (P < 0.05) between the gold standard method and the mathematical model when applied to HR (r s = 0.75) and VCO2 (r s = 0.78) data for the subjects as a whole (N = 29). The proposed mathematical method for the detection of changes in response patterns of VCO2 and HR was adequate and promising for AT detection in young and middle-aged women, representing a semi-automatic, non-invasive and objective AT measurement.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Early diagnosis plays a vital role in controlling tuberculosis. The conventional methodology is slow, with results taking several weeks, in addition to having low sensitivity, especially in clinical paucibacillary samples. The objective of this study was to evaluate the use of polymerase chain reaction (PCR) on solid medium culture for a rapid diagnosis of tuberculosis, mainly in cases of negative sputum smears. Forty sputum samples were collected from inpatients with tuberculosis treated for less than 2 days. Bacilloscopy, PCR for sputum, culture on Löwestein-Jensen (LJ) solid medium, and daily PCR from culture were performed on each sample. DNA extracted from the BCG vaccine, which contains attenuated bacillus Calmette-Guérin, was used as the positive control. Smear microscopy showed 68.6% sensitivity, 80% specificity, 96% positive predictive value, and 26.7% negative predictive value, with culture on LJ medium as the gold standard. Culture at day 28 showed 74.3% sensitivity and 100% specificity. PCR of DNA extracted from sputum amplified a 1027-bp fragment of the 16s RNA gene, showing 22.9% sensitivity and 60% specificity. PCR performed with DNA extracted from daily culture showed that, from the 17th to the 40th day, the sensitivity (85.7%) and specificity (60%) were constant. We conclude that a 17-day culture is a good choice for rapid diagnosis and to interfere with the transmission chain of tuberculosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Prompt and accurate detection of rejection prior to pathological changes after organ transplantation is vital for monitoring rejections. Although biopsy remains the current gold standard for rejection diagnosis, it is an invasive method and cannot be repeated daily. Thus, noninvasive monitoring methods are needed. In this study, by introducing an IL-2 neutralizing monoclonal antibody (IL-2 N-mAb) and immunosuppressants into the culture with the presence of specific stimulators and activated lymphocytes, an activated lymphocyte-specific assay (ALSA) system was established to detect the specific activated lymphocytes. This assay demonstrated that the suppression in the ALSA test was closely related to the existence of specific activated lymphocytes. The ALSA test was applied to 47 heart graft recipients and the proliferation of activated lymphocytes from all rejection recipients proven by endomyocardial biopsies was found to be inhibited by spleen cells from the corresponding donors, suggesting that this suppression could reflect the existence of activated lymphocytes against donor antigens, and thus the rejection of a heart graft. The sensitivity of the ALSA test in these 47 heart graft recipients was 100%; however, the specificity was only 37.5%. It was also demonstrated that IL-2 N-mAb was indispensible, and the proper culture time courses and concentrations of stimulators were essential for the ALSA test. This preliminary study with 47 grafts revealed that the ALSA test was a promising noninvasive tool, which could be used in vitro to assist with the diagnosis of rejection post-heart transplantation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hepatitis E virus (HEV) is classified within the family Hepeviridae, genus Hepevirus. HEV genotype 3 (Gt3) infections are endemic in pigs in Western Europe and in North and South America and cause zoonotic infections in humans. Several serological assays to detect HEV antibodies in pigs have been developed, at first mainly based on HEV genotype 1 (Gt1) antigens. To develop a sensitive HEV Gt3 ELISA, a recombinant baculovirus expression product of HEV Gt3 open reading frame-2 was produced and coated onto polystyrene ELISA plates. After incubation of porcine sera, bound HEV antibodies were detected with anti-porcine anti-IgG and anti-IgM conjugates. For primary estimation of sensitivity and specificity of the assay, sets of sera were used from pigs experimentally infected with HEV Gt3. For further validation of the assay and to set the cutoff value, a batch of 1100 pig sera was used. All pig sera were tested using the developed HEV Gt3 assay and two other serologic assays based on HEV Gt1 antigens. Since there is no gold standard available for HEV antibody testing, further validation and a definite setting of the cutoff of the developed HEV Gt3 assay were performed using a statistical approach based on Bayes' theorem. The developed and validated HEV antibody assay showed effective detection of HEV-specific antibodies. This assay can contribute to an improved detection of HEV antibodies and enable more reliable estimates of the prevalence of HEV Gt3 in swine in different regions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

High salt intake is related to an increase in blood pressure and development of hypertension. However, currently, there are no national representative data in Brazil using the gold standard method of 24-h urine collection to measure sodium consumption. This study aimed to determine salt intake based on 24-h urine collection in a sample of 272 adults of both genders and to correlate it with blood pressure levels. We used a rigorous protocol to assure an empty bladder prior to initiating urine collection. We excluded subjects with a urine volume <500 mL, collection period outside of an interval of 23-25 h, and subjects with creatinine excretion that was not within the range of 14.4-33.6 mg/kg (men) and 10.8-25.2 mg/kg (women). The mean salt intake was 10.4±4.1 g/day (d), and 94% of the participants (98% of men and 90% of women) ingested more than the recommended level of 5 g/d. We found a positive association between salt and body mass index (BMI) categories, as well as with salt and blood pressure, independent of age and BMI. The difference in systolic blood pressure reached 13 mmHg between subjects consuming less than 6 g/d of salt and those ingesting more than 18 g/d. Subjects with hypertension had a higher estimated salt intake than normotensive subjects (11.4±5.0 vs 9.8±3.6 g/d, P<0.01), regardless of whether they were under treatment. Our data indicate the need for interventions to reduce sodium intake, as well the need for ongoing, appropriate monitoring of salt consumption in the general population.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article critically resumes Ricardo's principle of comparative advantages pointing out internal coherence problems that have been neglected by the specialized literature. First, long-lasting disequilibria observed in the balance of trade seem incompatible with the idea that these disequilibria are caused by technical advances that change relative prices. Second, comparative advantages do not seem to work in an economy with a universally accepted commodity-money. Finally, the contradiction between the gold standard mechanisms, ruled by Smith's "Law of Reflux", and the quantitative theory of money, which is a necessary condition for the "second way" of the theory of comparative advantages.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

If emerging markets are to achieve their objective of joining the ranks of industrialized, developed countries, they must use their economic and political influence to support radical change in the international financial system. This working paper recommends John Maynard Keynes's "clearing union" as a blueprint for reform of the international financial architecture that could address emerging market grievances more effectively than current approaches. Keynes's proposal for the postwar international system sought to remedy some of the same problems currently facing emerging market economies. It was based on the idea that financial stability was predicated on a balance between imports and exports over time, with any divergence from balance providing automatic financing of the debit countries by the creditor countries via a global clearinghouse or settlement system for trade and payments on current account. This eliminated national currency payments for imports and exports; countries received credits or debits in a notional unit of account fixed to national currency. Since the unit of account could not be traded, bought, or sold, it would not be an international reserve currency. The credits with the clearinghouse could only be used to offset debits by buying imports, and if not used for this purpose they would eventually be extinguished; hence the burden of adjustment would be shared equally - credit generated by surpluses would have to be used to buy imports from the countries with debit balances. Emerging market economies could improve upon current schemes for regionally governed financial institutions by using this proposal as a template for the creation of regional clearing unions using a notional unit of account.