217 resultados para Aortic Diseases
Resumo:
In this report we describe the twelveth case in the literature of absence of the aortic valve cusps, associated with hypoplastic left-sided heart syndrome in a neonate. Clinical and hemodynamic conditions in our patient resemble the classical features of this syndrome except for a greater development of the ascending aorta and the left ventricular cavity, due to aortic insufficiency. A patch was unsuccessfully inserted at the aortic annulus to exclude the left ventricle from the circulation. In addition the Norwood operation was performed.
Resumo:
A rare association of pulmonary atresia with an intact septum was diagnosed through echocardiography in a fetus 32 weeks of gestational age. The diagnosis was later confirmed by echocardiography of the newborn infant and further on autopsy. The aortic valve was bicuspid with a pressure gradient of 81mmHg, and the right ventricle was hypoplastic, as were the pulmonary trunk and arteries, and the blood flow was totally dependent on the ductus arteriosus.
Resumo:
OBJECTIVE: To evaluated the clinical diagnostic, efficiency for basic death causes in patients dying of circulatory disease and de relative frequency of those diseases. METHODS: Analysis of medical record data of 82 patients, ages from 16 to 84 years old (68 over 40 years old), whose died of circulatory disease and had undergone necropsy in the period from 1988 to 1993 years in the University Hospital of Medicine Faculty of Botucatu-UNESP, Br. RESULTS: The functional class of patients were III or IV, in 78%, and 81.7% needed urgent hospitalization. By the clinical judgment the death were by ischemic heart disease in 32 (21 acute myocardial infarction), Chagas'disease in 12, valvopathy in 11, cardiomyopathy in 7, heart failure with no specification of cardiopathy in 11 and other causes in 9. At the necropsy the death cause was ischemic heart disease in 34 patients, valvopathy in 10, Chagas'disease in 10, cardiomyopathy in 5, and heart failure with no specification of cardiopathy in 2.The concordance taxes were in thhe same order: 94,6%, 90,0%, 83.3%, 71.4% and 28.5%. CONCLUSION: There was a great efficiency of clinical diagnosis for death cause in a general university hospital. The ischemic heart disease were the main causes of death.
Resumo:
We report the case of a patient with a pseudoaneurysm of the ascending aortic clinically diagnosed 5 months after surgical replacement of the aortic valve. Diagnosis was confirmed with the aid of two-dimensional echocardiography and helicoidal angiotomography. The corrective surgery, which consisted of a reinforced suture of the communication with the ascending aorta after opening and aspiration of the cavity of the pseudoaneurysm, was successfully performed through a complete sternotomy using extracorporeal circulation, femorofemoral cannulation, and moderate hypothermia, with no aortic clamping.
Resumo:
OBJECTIVE: To analyze the trends in mortality due to circulatory diseases in men and women aged > or = 30 years in Brazil from 1979 to 1996. METHODS: We analyzed population count data obtained from the IBGE Foundation and mortality data obtained from the System of Information on Mortality of the DATASUS of the Ministry of Health. RESULTS: Circulatory diseases, ischemic heart disease, and cerebrovascular disease were the major causes of death in men and women in Brazil. The standardized age coefficient for circulatory disease in men aged > or = 30 years ranged from 620 to 506 deaths/100,000 inhabitants and in women from 483 to 383 deaths/100,000 inhabitants for the years 1979 and 1996, respectively. In men, the mean coefficient for the period was 586.25 deaths with a significant trend towards a decrease (P<0.001) and a decline of 8.25 deaths/year. In women, the mean coefficient for the period was 439.58 deaths, a significant trend towards a decrease (P<0.001) and a rate of decline of 7.53 deaths/year. The same significant trend towards a decrease in death (P<0.001) was observed for ischemic heart disease and cerebrovascular disease. Risk of death from these causes was always higher for men of any age group (P<0.001). Cerebrovascular disease was the primary cause of death in women. CONCLUSION: Although circulatory diseases have been the major cause of mortality in men and women in the Brazilian population, with a greater participation by cerebrovascular diseases, a trend towards a decrease in the risk of death from these causes is being observed.
Resumo:
OBJECTIVE: To report the role played by transesophageal echocardiography during implantation of self-expanding aortic endoprostheses (stent) at a hemodynamics laboratory. METHODS: Thirteen patients underwent stent implantation in the descending thoracic aorta with the aid of transesophageal echocardiography during the entire procedure. Indications for stenting were as follows: 8 aortic dissections, 2 true aneurysms, 2 penetrating atherosclerotic ulcers, and 1 traumatic pseudoaneurysm. RESULTS: No complications resulting from the use of transesophageal echocardiography were observed. In 12 patients, the initial result was considered appropriate, with total or partial resolution of the major lesion confirmed by a posterior examination. In 1 patient, the procedure was suspended after transesophageal echocardiography and angiography showed that the proximal aortic diameter was inappropriate. Transesophageal echocardiography contributed to clarifying relevant points, such as aortic diameter, anatomic detail of the intimal lesion, and location and size of the communicating orifice. In addition, it facilitated placing the stent in the target lesion, reduced the time of exposure to radiation and the use of contrast medium, and provided rapid identification of intercurrent events, possibly reducing the total duration of the procedure. CONCLUSION: The use of transesophageal echocardiography during placement of aortic stents seems appropriate. The actual advantages of the procedure will be defined in a comparative prospective study.
Resumo:
OBJECTIVE: To evaluate elastic properties of conduit arteries in asymptomatic patients who have severe chronic aortic regurgitation. METHODS: Twelve healthy volunteers aged 30±1 years (control group) and 14 asymptomatic patients with severe aortic regurgitation aged 29±2 years and left ventricular ejection fraction of 0.61±0.02 (radioisotope ventriculography) were studied. High-resolution ultrasonography was performed to measure the systolic and diastolic diameters of the common carotid artery. Simultaneous measurement of blood pressure enabled the calculation of arterial compliance and distensibility. RESULTS: No differences were observed between patients with aortic regurgitation and the control group concerning age, sex, body surface, and mean blood pressure. Pulse pressure was significantly higher in the aortic regurgitation group compared with that in the control group (78±3 versus 48±1mmHg, P<0.01). Arterial compliance and distensibility were significantly greater in the aortic regurgitation group compared with that in the control group (11.0±0.8 versus 8.1±0.7 10-10 N-1 m4, P=0.01 e and 39.3±2.6 versus 31.1±2.0 10-6 N-1 m², P=0.02, respectively). CONCLUSION: Patients with chronic aortic regurgitation have increased arterial distensibility. Greater vascular compliance, to lessen the impact of systolic volume ejected into conduit arteries, represents a compensatory mechanism in left ventricular and arterial system coupling.
Resumo:
OBJECTIVE: Our aim was to compare, in a non randomized study, the surgical outcome in elderly patients with mechanical (Group 1; n=83) and bioprosthetic valve implants (Group 2; n=136). METHODS: During a three year period, 219 patients >75 years underwent Aortic Valve Replacement. The groups matched according to age, sex, comorbidity, valve pathology and concomitant Coronary Artery Bypass Surgery. Follow-up was a total of 469 patient-years (mean follow-up 2.1 years, maximum 4,4 years). RESULTS: Operative mortality was zero and the overall early mortality was 2.3 % (within 30 days). Actuarial survival was 87.5 ± 4.0% and 66.1 ± 7.7% (NS) at 4 years in Group 1 and Group 2, respectively. Freedom from valve-related death was 88.9 ± 3.8% in Group 1 and 69.9±7.9% (NS) in Group 2 at 4 years. CONCLUSION: Aortic Valve Replacement in the elderly (>75 years) is a safe procedure even in cases where concomitant coronary artery revascularization is performed. Only a few anticoagulant-related complications were reported and this may indicate that selected groups of elderly patients with significant life expectancy may benefit from mechanical implants .
Resumo:
We report the case of a 27-year-old male patient with dyspnea on physical exertion. Clinical assessment and various tests led to the diagnosis of aortopulmonary window and double aortic arch. According to a literature search, this may be the first report on such association.