100 resultados para validation of pharmaceutical methods
Resumo:
OBJECTIVE To construct statements of nursing diagnoses related to nursing practice for individuals with diabetes in Specialized Care, on the basis of the Database of Nursing Practice Terms related to diabetes, in the International Classification for Nursing Practice (ICNP®) and in the Theory of Basic Human Needs and to validate them with specialist nurses in the area. METHOD Methodological research, structured into sequential stages of construction, cross-mapping, validation and categorization of nursing diagnoses. RESULTS A list was indicated of 115 statements of diagnostic, including positive, negative and improvement statements; 59 nursing diagnoses present in and 56 nursing diagnoses absent from the ICNP® Version 2011. 66 diagnoses with CVI ≥ 0.50 were validated, being categorized on the basis of human needs. CONCLUSION It was observed that the use of the ICNP® 2011 favored the specifications of the concepts of professional practice in care with individuals with diabetes.
Resumo:
Abstract OBJECTIVE To describe the stages of construction and validation of an instrument in order to analyze the adherence to best care practices during labour and birth. METHOD Methodological research, carried out in three steps: construction of dimensions and items, face and content validity and semantic analysis of the items. RESULTS The face and content validity was carried out by 10 judges working in healthcare, teaching and research. Items with Content Validity Index (CVI) ≥ 0.9 were kept in full or undergone revisions as suggested by the judges. Semantic analysis, performed twice, indicated that there was no difficulty in understanding the items. CONCLUSION The instrument with three dimensions (organization of healthcare network to pregnancy and childbirth, evidence-based practices and work processes) followed the steps recommended in the literature, concluded with 50 items and total CVI of 0.98.
Development and validation of an instrument for evaluating the ludicity of games in health education
Resumo:
Abstract OBJECTIVE Developing and validating an instrument to evaluate the playfulness of games in health education contexts. METHODOLOGY A methodological, exploratory and descriptive research, developed in two stages: 1. Application of an open questionnaire to 50 graduate students, with content analysis of the answers and calculation of Kappa coefficient for defining items; 2. Procedures for construction of scales, with content validation by judges and analysis of the consensus estimate byContent Validity Index(CVI). RESULTS 53 items regarding the restless character of the games in the dimensions of playfulness, the formative components of learning and the profiles of the players. CONCLUSION Ludicity can be assessed by validated items related to the degree of involvement, immersion and reinvention of the subjects in the game along with the dynamics and playability of the game.
Resumo:
A quantitative model of water movement within the immediate vicinity of an individual root is developed and results of an experiment to validate the model are presented. The model is based on the assumption that the amount of water transpired by a plant in a certain period is replaced by an equal volume entering its root system during the same time. The model is based on the Darcy-Buckingham equation to calculate the soil water matric potential at any distance from a plant root as a function of parameters related to crop, soil and atmospheric conditions. The model output is compared against measurements of soil water depletion by rice roots monitored using γ-beam attenuation in a greenhouse of the Escola Superior de Agricultura "Luiz de Queiroz"/Universidade de São Paulo(ESALQ/USP) in Piracicaba, State of São Paulo, Brazil, in 1993. The experimental results are in agreement with the output from the model. Model simulations show that a single plant root is able to withdraw water from more than 0.1 m away within a few days. We therefore can assume that root distribution is a less important factor for soil water extraction efficiency.
Resumo:
In agriculture, the soil strength is used to describe the susceptibility to deformation by pressure caused by agricultural machine. The purpose of this study was to compare different methods for estimating the inherent soil strength and to identify their suitability for the evaluation of load support capacity, compaction susceptibility and root growth. The physical, chemical, mineralogical and intrinsic strength properties of seven soil samples, collected from five sampling pits at different locations in Brazil, were measured. Four clay (CS) and three sandy clay loam (SCL) soils were used. The clay soils were collected on a farm in Santo Ângelo, RS (28 º 16 ' 16 '' S; 54 º 13 ' 11 '' W 290 m); A and B horizons at the Universidade Federal de Lavras, Lavras, MG (21 º 13 ' 47 '' S; 44 º 58 ' 6'' W; 918 m) and on the farm Sygenta, in Uberlandia, MG (18 º 58 ' 37 '' S; 48 º 12 ' 05 '' W 866 m). The sandy clay loam soils were collected in Aracruz, ES (19 º 47 ' 10 '' S; 40 º 16 ' 29 '' W 81 m), and on the farm Xavier, Lavras, MG (21 º 13 ' 24 '' S; 45 º 05 ' 00 '' W; 844 m). Soil strength was estimated based on measurements of: (a) a pneumatic consolidometer, (b) manual pocket (non-rotating) penetrometer; and (c) automatic (rotating) penetrometer. The results of soil strength properties were similar by the three methods. The soil structure had a significant influence on soil strength. Results of measurements with both the manual pocket and the electric penetrometer were similar, emphasizing the influence of soil texture. The data showed that, to enhance the reliability of predictions of preconsolidation pressure by penetrometers, it is better to separate the soils into the different classes, rather than analyze them jointly. It can be concluded that the consolidometer method, although expensive, is the best when evaluations of load support capacity and compaction susceptibility of soil samples are desired.
Resumo:
There are currently many devices and techniques to quantify trace elements (TEs) in various matrices, but their efficacy is dependent on the digestion methods (DMs) employed in the opening of such matrices which, although "organic", present inorganic components which are difficult to solubilize. This study was carried out to evaluate the recovery of Fe, Zn, Cr, Ni, Cd and Pb contents in samples of composts and cattle, horse, chicken, quail, and swine manures, as well as in sewage sludges and peat. The DMs employed were acid digestion in microwaves with HNO3 (EPA 3051A); nitric-perchloric digestion with HNO3 + HClO4 in a digestion block (NP); dry ashing in a muffle furnace and solubilization of residual ash in nitric acid (MDA); digestion by using aqua regia solution (HCl:HNO3) in the digestion block (AR); and acid digestion with HCl and HNO3 + H2O2 (EPA 3050). The dry ashing method led to the greatest recovery of Cd in organic residues, but the EPA 3050 protocol can be an alternative method for the same purpose. The dry ashing should not be employed to determine the concentration of Cr, Fe, Ni, Pb and Zn in the residues. Higher Cr and Fe contents are recovered when NP and EPA 3050 are employed in the opening of organic matrices. For most of the residues analyzed, AR is the most effective method for recovering Ni. Microwave-assisted digestion methods (EPA3051 and 3050) led to the highest recovery of Pb. The choice of the DM that provides maximum recovery of Zn depends on the organic residue and trace element analyzed.
Resumo:
The lack of a standard method to regulate heavy metal determination in Brazilian fertilizers and the subsequent use of several digestion methods have produced variations in the results, hampering interpretation. Thus, the aim of this study was to compare the effectiveness of three digestion methods for determination of metals such as Cd, Ni, Pb, and Cr in fertilizers. Samples of 45 fertilizers marketed in northeastern Brazil were used. A fertilizer sample with heavy metal contents certified by the US National Institute of Standards and Technology (NIST) was used as control. The following fertilizers were tested: rock phosphate; organo-mineral fertilizer with rock phosphate; single superphosphate; triple superphosphate; mixed N-P-K fertilizer; and fertilizer with micronutrients. The substances were digested according to the method recommended by the Ministry for Agriculture, Livestock and Supply of Brazil (MAPA) and by the two methods 3051A and 3052 of the United States Environmental Protection Agency (USEPA). By the USEPA method 3052, higher portions of the less soluble metals such as Ni and Pb were recovered, indicating that the conventional digestion methods for fertilizers underestimate the total amount of these elements. The results of the USEPA method 3051A were very similar to those of the method currently used in Brazil (Brasil, 2006). The latter is preferable, in view of the lower cost requirement for acids, a shorter digestion period and greater reproducibility.
Resumo:
The objective of this work was to validate microsatellite markers associated with resistance to soybean cyst nematode (Heterodera glycines Ichinohe) races 3 and 14, in soybean (Glycine max L.) genotypes, for use in marker-assisted selection (MAS) programs. Microsatellites of soybean linkage groups A2, D2 and G were tested in two populations, and their selection efficiencies were determined. The populations were 65 F2:3 families from Msoy8001 (resistant) x Conquista (susceptible) cross, and 66 F2:3 families of S5995 (resistant) x Renascença (susceptible) cross, evaluated for resistance to races 3 and 14, respectively. Families with female index up to 30% were considered moderately resistant. Markers of A2 and G linkage groups were associated with resistance to race 3. Markers Satt309 and GMENOD2B explained the greatest proportion of phenotypic variance in the different groups. The combinations Satt309+GMENOD2B and Satt309+Satt187 presented 100% selection efficiency. Resistance to race 14 was associated with markers of G linkage group, and selection efficiency in the Satt309+Satt356 combination was 100%. The selection differential obtained by phenotypic and marker assisted selection showed that both can result in similar gains.
Resumo:
This work describes a validation of an analytical procedure for the analysis of petroleum hydrocarbons in marine sediment samples. The proposed protocol is able to measure n-alkanes and polycyclic aromatic hydrocarbons (PAH) in samples at concentrations as low as 30 ng/g, with a precision better than 15% for most of analytes. The extraction efficiency of fortified sediments varied from 65.1 to 105.6% and 59.7 to 97.8%, for n-alkanes and PAH in the ranges: C16 - C32 and fluoranthene - benzo(a)pyrene, respectively. The analytical protocol was applied to determine petroleum hydrocarbons in sediments collected from a marine coastal zone.
Resumo:
This work reports the validation of an analytical UV spectrophotometric method to assay dexamethasone in tablets (assay and dissolution studies). The method was linear in the range between 1 and 30 µg mL-1 presenting a good correlation coefficient (r = 0.9998, n = 7). Precision and accuracy analysis showed low relative standard deviation (< 2.00%) and good percentual recoveries (95-105%). The procedure was linear, accurate, precise, and robust. The method is simple, and it has low cost. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay dexamethasone in tablets.
Resumo:
A dissolution test for telithromycin tablets was validated and developed. In order to choose the most discriminatory one, the conditions to carry out are 900 mL of sodium phosphate buffer at pH 7.5, paddles at 50 rpm stirring speed, time test set to 60 min and using USP apparatus 2 with paddles. The UV spectrophotometric method for determination of telithromycin released was developed and validated. The method presents linearity (r = 1) in the concentration range of 20-60 µg/mL. Precision and recoveries were good, 100.62 and 97.06%, respectively. The method was successfully used for the dissolution test of telithromycin tablets.
Resumo:
A LC-ESI-MS/MS method was developed and validated according to the European Union decision 2002/657/EC, for the determination of tetracyclines (TCs) in chicken-muscle since Europe is one of the main markets for Brazilian products. Linearity of r > 0.9979, limits of quantification in the range of 7.0-35.0 ng/g, average recoveries of 89.38 - 106.27%, within-day and between-day precision were adequate for all TCs. The decision limit and the detection capability were 93.00-106.46 ng/g and 95.84-114.38 ng/g, respectively. This method is suitable for application in surveillance programmes of residues of TCs in chicken-muscle samples.
Resumo:
An HPLC method was developed and validated aiming to quantify the cyclosporine-A incorporated into intraocular implants, released from them; and in direct contact with the degradation products of PLGA. The separation was carried out in isocratic mode using acetonitrile/water (70:30) as mobile phase, a C18 column at 80 ºC and UV detection at 210 nm. The method provided selectivity based on resolution among peaks. It was linear over the range of 2.5-40.0 µg/mL. The quantitation and detection limits were 0.8 and 1.2 µg/mL, respectively. The recovery was 101.8% and intra-day and inter-day precision was close to 2%.
Resumo:
This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.
Resumo:
This study describes the validation of a spectrophotometric method to estimate oligonucleotides association with cationic nanoemulsions. Phosphodiester and phosphorothioate oligonucleotides targeting Plasmodium falciparum topoisomerase II were analyzed at 262 nm. Linear response (r > 0.998) was observed from 0.4 to 1.0 nmol/mL, the relative standard deviation values for the intra- and inter-days precision were lower than 2.6% and the recovery ranged from 98.8 to 103.6% for both oligonucleotides. The association efficiency was estimated based on an ultrafiltration/centrifugation method. Oligonucleotides recovery through 30 kDa-membranes was higher than 92%. The extent of oligonucleotides association (42 to 98%) varied with the composition of nanoemulsions