101 resultados para liquid and gas chromatography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quantitative chemical analysis of the Brazilian sugar cane spirit distilled from glass column packaged with copper, stainless steel, aluminum sponge, or porcelain balls is described. The main chemical compounds determined by gas chromatography coupled with flame ionization (FID) and flame photometric (FPD) detectors and liquid chromatography coupled with diode array detector are aldehydes, ketones, carboxylic acids, alcohols, esters and dimethylsulfite (DMS). The spirits produced either in columns filled with copper or aluminum pot still exhibits the lowest DMS contents but the higher sulfate and methanol contents, whereas spirits produced in stainless steel or porcelain showed higher DMS concentration and lower teors of sulfate ion and methanol. These observations are coherent with DMS oxidation to sulfate, with methanol as by product, in the presence of either copper or aluminum.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the analytical methods for determination of total chlorogenic acid (CGA) and their individual isomers. Spectrofotometric methods are adequate for total CGA analysis in green coffee but they can provide inflated results for coffee products. High pressure liquid chromatography (HPLC) with gel permeation column and ultraviolet (UV) monitoring is adequate for the simultaneous analysis of total CGA, alkaloids and sugars in coffee products. HPLC-UV-reversed phase is a simple, rapid and precise method for the determination of the individual isomers of CGA. Gas chromatography (GC) also is applied to the analysis of the individual isomers but phenolic acids need to be derivatized before analysis. Both HPLC- and GC-mass spectrometry provide an unequivocal identification of the individual isomers. The capillary electrophoresis method is simple, rapid and adequate to the simultaneous analysis of polyphenols and xanthines. Advantages and limitations of each method are discussed throughout the text.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The scope of this study encompasses an overview of the principles of unified chromatography as well as the principles of chromatographic techniques as applied to unified systems, which include gas chromatography, liquid chromatography, supercritical fluid chromatography, high temperature and high pressure liquid chromatography, micro-liquid chromatography, enhanced fluidity chromatography, and solvating gas chromatography. Theoretical considerations and individual instrumental parameters such as mobile phase, sample introduction system, columns, and detection system are also discussed. Future applications of this separation approach are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gravimetric and Bailey-Andrew methods are tedious and provide inflated results. Spectrofotometry is adequate for caffeine analysis but is lengthy. Gas chromatography also is applied to the caffeine analysis but derivatization is needed. High performance liquid chromatography with ultraviolet detection (HPLC-UV) and reversed phase is simple and rapid for xanthine multianalysis. In HPLC-UV-gel permeation, organic solvents are not used. HPLC-mass spectrometry provides an unequivocal structural identification of xanthines. Capillary electrophoresis is fast and the solvent consumption is smaller than in HPLC. Chemometric methods offer an effective means for chemical data handling in multivariate analysis. Infrared spectroscopy alone or associated with chemometries could predict the caffeine content in a very accurate form. Electroanalytical methods are considered of low cost and easy application in caffeine analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The liquid-liquid extraction with the low temperature partition technique was developed for the analysis of four pyrethroids in water by CG. Using a factorial design the extraction technique was optimised evaluating the effect of the variables ionic strength, contact time and proportion between sample and solvent volumes. The validation parameters sensitivity, precision, accuracy and detection and quantification limits were evaluated. The LOD and LOQ of the method varied from 1.1 to 3.2 µg L-1 and 2.7 to 9.5 µg L-1, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Based on a specially created mass spectral database utilizing 23 tetradecenyl and 22 hexadecenyl acetate standards along with Kóvats retention indices obtained on a very polar stationary phase [poly (biscyanopropyl siloxane)] (SP 2340), (Z)-9-hexadecenyl acetate, (Z)-11-hexadecenyl acetate and (E)-8-hexadecenyl acetate were identified in active pheromone extracts of Elasmopalpus lignosellus. This identification was more efficient than our previous study using gas chromatography/mass spectrometry with a dimethyl disulfide derivative where we could only identify the first two acetates. The acetate composition of the pheromone gland differed from region to region in Brazil and from that from the Tifton (GA, USA) population, suggesting polymorphism or a different sub-species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The essential oils from leaves (sample A) and flowers (sample B) of Aeolanthus suaveolens Mart. ex Spreng were obtained by hydrodistillation and analyzed by GC, GC-MS, and chiral phase gas chromatography (CPGC). Six compounds have been identified from the essential oils, representing ca 94.3 and 93% of the oils corresponding to samples A and B, respectively. The major constituents of samples A and B essential oils were respectively, linalool (34.2%/34.9%), (-)-massoialactone (25.9%/17.0%) and (E)-beta-farnesene (25.4%/29.1%). The enantiomeric distribution of the monoterpene linalool was established by analysis on heptakis- (6-O-methyl-2,3-di-O-pentyl)-beta-cyclodextrin capillary column. The antimicrobial activity of the essential oil from leaves and isolated compounds was also evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of this work is to develop an efficient procedure to determine glyphosate in soybean grains. The cleanup of the aqueous extracts was done in two steps, beginning with liquid-liquid partitioning and then solid-phase extraction with anion exchange resin. After derivatization with a mixture of trifluoroacetic anhydride (TFAA) and trifluoroethanol (TFE), quantification was done by gas chromatography coupled to mass spectrometry. The mean recovery and RSD of the spiked samples were, respectively, 80.5% and 3.1% at level 0.200 mg kg-1, 93.3% and 18.7% at level 0.500 mg kg-1 and 92% and 3.5% at level 1.000 mg kg-1. The method was linear in the working range (correlation coefficient = 0.9965).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work aimed to quantify some organic compounds in "cachaças" (sugar cane spirit). The ethyl alcohol was quantified by densimetry, after distillation. The acetic acid, methyl alcohol, n-propyl alcohol, n-butyl alcohol, isobutyl alcohol, isoamyl alcohol (mixture of 2-methyl-butyl and 3-methyl-butyl), ethyl acetate and acetaldehyde were determined by gas chromatography; and the furfural, 5-hydroxy-methylfurfural and acrolein by high efficiency liquid chromatography. From the 30 samples analyzed, 63.3% showed non-conformity with national legislation regarding at least one of the analyzed components.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work a new method (SPME-GC/FID) was developed to analyze the activity of binary liquid mixtures. The purpose is to demonstrate that SPME is capable to be used to determinate activity coefficients at infinite dilution knowing the fiber properties, with a lower cost than the conventional methods encountered in literature such as GLC. The activity coefficients at infinite dilution in furfural for n-hexane, n-heptane and cyclohexane at 298.15 K was determined using SPME and deviations of literature data was about 7%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work describes the determination of polychlorinated biphenyls in 123 umbilical cord serum samples by liquid-liquid extraction method with acid hydrolyze step and analysis by GC-mECD. The analytical method was evaluated with following figures of merit for all PCBs: linearity (>0.997); precision (<12.55%); recoveries (73-119%); limit of detection (0.1 ng mL-1); limit of quantification (0.25-0.5 ng mL-1). The results showed high contamination in the analyzed samples. PCB more frequent was 138 (66.7%), followed by 180 (55.3%) and 52 (51.3%).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Topiramate and the other frequently co-administered antiepileptic drugs carbamazepine, phenytoin and phenobarbital were determined in 100 µL plasma samples by gas chromatography with nitrogen phosphorus detection (GC-NPD), after a one-step liquid-liquid extraction with ethyl acetate, followed by flash methylation with trimethylphenylammonium hydroxide. Total chromatographic run time was 12.5 min. Intra-assay and inter-assay precision was 2.5-7.3% and 1.6-5.2%, respectively. Accuracy was 100.1-104.2%. The limit of quantitation was 1 µg mL-1 for all analytes, proving suitable for routine application in therapeutic drug monitoring of antiepileptic drugs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to verify the presence of meat and bone meal (MBM) in ruminant feed, by identifying the cholesterol using gas chromatography with a flame ionization detector. The proposed method demonstrated precision, trueness, and capability to detect MBM in the ruminant feed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the current study, an alternative method has been proposed for simultaneous analysis of palmitic, stearic, oleic, linoleic, and linolenic acids by capillary zone electrophoresis (CZE) using indirect detection. The background electrolyte (BGE) used for the analysis of these fatty acids (FAs) consisted of 15.0 mmol L−1 NaH2PO4/Na2HPO4 at pH 6.86, 4.0 mmol L−1 SDBS, 8.3 mmol L−1 Brij 35, 45% v/v acetonitrile (can), and 2.1% n-octanol. The FAs quantification of FAs was performed using a response factor approach, which provided a high analytical throughput for the real sample. The CZE method, which was applied successfully for the analysis of pequi pulp, has advantages such as short analysis time, absence of lipid fraction extraction and derivatization steps, and no significant difference in the 95% confidence intervals for FA quantification results, compared to the gas chromatography official method (AOCS Ce 1h-05).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to optimize and validate a solid-liquid extraction method with low-temperature partitioning (SLE/LTP) for the analysis of pesticides. This method was coupled with gas chromatography (GC/ECD) and used to evaluate the degradation of bifenthrin and pirimiphos-methyl in maize grains on exposure to ozone. The optimized SLE/LTP-GC/ECD method is simple, effective and consumes low quantities of the solvent. It can be routinely used for the determination of bifenthrin and pirimiphos-methyl in maize samples. The use of this method of analysis determined that the levels of the insecticides in maize grains were reduced on exposure of the grains to the ozone gas. The observed reduction in the levels of insecticide was directly proportional to the increase in the concentration of the ozone gas.